Breakpoint: left main stent fracture--review of the literature.

Abstract:

:The incidence and morbidity associated with stent fracture are unknown. Recommendations and evidence-based treatment are lacking. We report a case of symptomatic fracture of a sirolimus-eluting stent advancing from the left main into the circumflex coronary artery, forming an acute angle with calcifications at the hinge point; the literature is reviewed and treatment options are discussed.

journal_name

J Interv Cardiol

authors

Tizón-Marcos H,De Larochellière R,Larose E

doi

10.1111/j.1540-8183.2009.00484.x

subject

Has Abstract

pub_date

2009-08-01 00:00:00

pages

362-7

issue

4

eissn

0896-4327

issn

1540-8183

pii

JOIC484

journal_volume

22

pub_type

杂志文章,评审
  • Cutting balloon for in-stent restenosis: acute and long-term results.

    abstract:INTRODUCTION:Conventional percutaneous coronary intervention for the treatment of in-stent restenosis (ISR) has shown a high rate of ISR (30-55%). Considering the need for both extrusion of hyperplastic intima and additional stent expansion, a cutting balloon might be more effective for the treatment of ISR. METHODS:W...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2004.00378.x

    authors: Rahel BM,Suttorp MJ,ten Berg JM,Bal ET,Ernst SM,Rensing BJ,Kelder JC,Plokker HW

    更新日期:2004-08-01 00:00:00

  • Simple technique to ensure coaxial guidewire positioning for placement of iliac limb of modular aortic endograft.

    abstract::Endovascular abdominal aortic aneurysm repair using a modular bifurcated stent-graft requires the initial placement of the main component in the infrarenal aorta, followed by insertion of additional iliac stent-graft(s) to exclude aneurysm and to securely affix the device. Placement of the contralateral iliac componen...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章,评审

    doi:10.1034/j.1600-0854.2003.8046.x

    authors: Dawson DL,Terramani TT,Loberman Z,Lumsden AB,Lin PH

    更新日期:2003-06-01 00:00:00

  • Crushed clopidogrel administered via nasogastric tube has faster and greater absorption than oral whole tablets.

    abstract:OBJECTIVES:To compare the absorption of 300 mg clopidogrel administered crushed via nasogastric (NG) tube versus whole tablets taken orally in healthy volunteers. BACKGROUND:Earlier antiplatelet therapy has proven benefits in treatment of myocardial infarction and in patients undergoing PCI. Aspirin can be delivered e...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2009.00475.x

    authors: Zafar MU,Farkouh ME,Fuster V,Chesebro JH

    更新日期:2009-08-01 00:00:00

  • Initial experience with paclitaxel-coated stents.

    abstract::Local delivery of immunosuppressive or antiproliferative agents using a drug-eluting stent is a new technology that is supposed to inhibit in-stent restenosis, thus providing a biological and mechanical solution. This technique is a very promising. To date, several agents have been used, including paclitaxel, QP-2, ra...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章,评审

    doi:10.1111/j.1540-8183.2002.tb01091.x

    authors: Grube E,Büllesfeld L

    更新日期:2002-12-01 00:00:00

  • Comparison between the safety profile and clinical results of the Cook detachable and Gianturco coils for transcatheter closure of patent ductus arteriosus in 272 patients.

    abstract:OBJECTIVES:We evaluated the occlusion rate and safety of Cook detachable coils versus Gianturco coils in transcatheter closure of patent ductus arteriosus (PDA). BACKGROUND:The Cook detachable coil recently was introduced in an attempt to improve the safety of transcatheter closure of PDA. METHODS:Between January 199...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2001.tb00730.x

    authors: Galal MO,Bulbul Z,Kakadekar A,Fatani AE,de Moor M,el-Oufi S,Solymar L,al-Fadley F,Fawzy ME

    更新日期:2001-04-01 00:00:00

  • Mechanisms for enlarging lesion size during irrigated tip radiofrequency ablation: is there a virtual electrode effect?

    abstract:INTRODUCTION:Irrigated tip radiofrequency ablation of cardiac arrhythmias was developed to increase the size of the radiofrequency-induced lesion, since cooling of the electrode tip allows use of higher power settings. The purpose of this study was to determine if the increased lesion size during irrigated tip ablation...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2004.09879.x

    authors: Petersen HH,Roman-Gonzalez J,Johnson SB,Hastrup Svendsen J,HaunsØ S,Packer DL

    更新日期:2004-06-01 00:00:00

  • Interventional occlusion of congenital vascular malformations with the detachable Cook coil system.

    abstract:INTRODUCTION:Nonsurgical closure of pathologic vascular communications can be achieved by coil embolization. Different systems used in patients with congenital heart disease (e.g., patent ductus arteriosus) allow controlled release of the devices. However, they are too stiff for coil occlusion of small or tortuous vess...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2001.tb00338.x

    authors: Sieverding L,Breuer J

    更新日期:2001-06-01 00:00:00

  • Long-term outcome of patients with severe biventricular heart failure and severe mitral regurgitation after percutaneous edge-to-edge mitral valve repair.

    abstract:OBJECTIVE:To assess long-term outcome and parameters associated with poor and favorable outcome in patients with a left ventricular ejection fraction (LV-EF) ≤25% and severe mitral regurgitation (MR) after percutaneous edge-to-edge mitral valve repair (pMVR). BACKGROUND:There is no data on long-term outcome in this co...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/joic.12193

    authors: Orban M,Braun D,Orban M,Grebmer C,Sibbing D,Thaler R,Tittus J,Wimbauer F,Lesevic H,Sonne C,Mehilli J,Ott I,Näbauer M,Massberg S,Boekstegers P,Hausleiter J

    更新日期:2015-04-01 00:00:00

  • Simultaneous dual vascular access site for the treatment of coronary artery bifurcation lesions by complex 2-stent technique.

    abstract:OBJECTIVES:To propose an original approach based on simultaneous dual vascular access site (DAS) using 2 small-size guiding catheters to easily perform complex 2-stent techniques for bifurcation coronary lesions (BL). BACKGROUND:Simultaneous kissing stenting and classic crush technique require large 7 or 8Fr guiding c...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2012.00745.x

    authors: Isaaz K,Mayaud N,Lamaud M,Raynaud A,Cerisier A,Sabry MH,Richard L,Khamis H,Abd-Alaziz A,DA Costa A

    更新日期:2012-10-01 00:00:00

  • Drug-Coated Balloons: A Safe and Effective Alternative to Drug-Eluting Stents in Small Vessel Coronary Artery Disease.

    abstract:BACKGROUND:Drug-coated balloons (DCB) have been used to treat de novo small vessel coronary disease (SVD), with promising results and shorter dual antiplatelet therapy (DAPT) duration compared to drug-eluting stents (DES). We compared safety and effectiveness of the two treatments at 1 year. METHODS:We reviewed 3,613 ...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/joic.12333

    authors: Sinaga DA,Ho HH,Watson TJ,Sim A,Nyein TT,Jafary FH,Loh JK,Ooi YW,Tan JK,Ong PJ

    更新日期:2016-10-01 00:00:00

  • Twenty-four-month update on double-kissing crush stenting of bifurcation lesions.

    abstract::A group of 312 patients who underwent percutaneous coronary intervention for bifurcation lesions at 12 centers in China, Singapore, Thailand, Israel, India, and Japan were enrolled in a prospective, randomized DKCRUSH-1 trial. The goal of the study was to compare the double kissing (DK) crush technique with the classi...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1111/j.1540-8183.2009.00440.x

    authors: Chen SL,Kwan TW

    更新日期:2009-04-01 00:00:00

  • Usefulness of embolic protection devices during saphenous vein graft intervention in a nonselected population.

    abstract::Distal embolic protection devices have been shown to reduce the risk of peri-procedural complications associated with saphenous vein graft intervention. However, there are several important anatomic limitations that may preclude routine device use. We analyzed the angiograms of 624 consecutive saphenous vein graft int...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2005.04063.x

    authors: Webb LA,Dixon SR,Safian RD,O'Neill WW

    更新日期:2005-04-01 00:00:00

  • Antithrombin and thrombolytic effects of a new antithrombin agent: angioscopic and angiographic comparison with heparin or batroxobin.

    abstract::The antithrombotic effect of three different types of antithrombotic agents (antithrombin:argatroban, heparin, defibrinogenating agent:batroxobin) were evaluated in canine coronary and iliac arteries. An occlusive thrombus was produced by balloon injury. One of the three agents was infused intravenously at 1 hour afte...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.1994.tb00478.x

    authors: Tomaru T,Nakamura F,Miwa AY,Fujimori Y,Omata M,Okada R,Uchida Y

    更新日期:1994-10-01 00:00:00

  • Stent implantation for coarctation in adults.

    abstract::Transcatheter dilatation is considered the elective treatment of residual coarctation. In the presence of native coarctation, dilatation is often effective but in the first months of life, and the risk of aneurysm formation is not low. The use of stents in adolescents and adults provides excellent results and seems to...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1046/j.1540-8183.2003.01004.x

    authors: Piéchaud JF

    更新日期:2003-10-01 00:00:00

  • Left atrial anatomy and patient-related factors associated with adverse outcomes with the watchman device-a real world experience.

    abstract:OBJECTIVE:This study sought to identify patient and left atrial morphology specific factors associated with early complications for left atrial appendage occlusion with the Watchman™ (Boston Scientific, Natick, MA) device. BACKGROUND:Oral anticoagulation (OAC) is recommended for patients with atrial fibrillation, howe...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/joic.12374

    authors: Murarka S,Lazkani M,Moualla S,Verma DR,Pershad A

    更新日期:2017-04-01 00:00:00

  • Clinical Implications of Bifurcation Angles in Left Main Bifurcation Intervention Using a Two-Stent Technique.

    abstract:Objectives:The aim of this study was to assess the clinical impact of 3 bifurcation angles in left main (LM) bifurcation treated with the 2-stent technique. Background:Data are limited regarding the impact of bifurcation angles after LM percutaneous coronary intervention (PCI). Methods:Using patient-level 4 multicent...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1155/2020/2475930

    authors: Ki YJ,Jung JH,Han JK,Hong S,Cho JH,Gwon HC,Lee SY,Rhew JY,Chae JK,Chae IH,Yang HM,Park KW,Kang HJ,Koo BK,Kim HS

    更新日期:2020-07-11 00:00:00

  • Indications of implantable defibrillator.

    abstract::Implantable cardioverter defibrillators are devices capable of detecting and terminating ventricular tachycardias or fibrillations. They are utilized in the treatment of severe ventricular tachyarrhythmias, and their efficacy in the prevention of sudden death is demonstrated. As a matter of fact, despite the new antia...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.1995.tb00931.x

    authors: Coumel P

    更新日期:1995-12-01 00:00:00

  • MRI evaluation of local myocardial treatments: epicardial versus endocardial (Cell-Fix catheter) injections.

    abstract:AIMS:We compared two procedures for local myocardial treatment: transepicardial versus transendocardial catheter injection. Transepicardial injections were performed under direct surgical visualization whereas transendocardial injections were performed using electrophysiological guidance. METHODS:A left ventricle (LV)...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2007.00255.x

    authors: Chachques JC,Azarine A,Mousseaux E,El Serafi M,Cortes-Morichetti M,Carpentier AF

    更新日期:2007-06-01 00:00:00

  • Is it safe to close ASD with the guidance of transthoraxic echocardiography in pediatric population "ten years' experience of a single center".

    abstract:OBJECTIVE:Main purpose of this study is to emphasize the usage and safety of transthoracic echocardiography (TTE) in percutaneous atrial septal defect (ASD) closure in appropriate pediatric cases. BACKGROUND:Nowadays, percutaneous closure is preferred as treatment modality for ASD in pediatric age group. METHODS:Betw...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/joic.12197

    authors: Baykan A,Pamukcu O,Ozyurt A,Argun M,Onan SH,Sezer S,Uzum K,Narin N

    更新日期:2015-04-01 00:00:00

  • Midterm Clinical Impacts of Biodegradable Polymer Everolimus-Eluting Stents Compared with Durable Polymer Everolimus-Eluting Stents: A 3-Year Propensity-Matched Study.

    abstract:Objectives:Our aim was to evaluate the safety and efficacy of biodegradable polymer everolimus-eluting stents (BP-EES) compared with durable polymer everolimus-eluting stents (DP-EES) in midterm. Background:There are few data about midterm clinical outcomes of BP-EES compared with DP-EES. Methods and Results:Between ...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1155/2020/2869303

    authors: Matsuda H,Kagase A,Tokuda T,Ochiumi Y,Murata A,Suzuki Y,Ito T

    更新日期:2020-04-20 00:00:00

  • Transcatheter Atrial Septal Defect Closure in Children with and without Fluoroscopy: A Comparison.

    abstract:Objective:The aim of this study was to compare feasibility, effectiveness, safety, and outcome of atrial septal defect (ASD) device closure in children with and without fluoroscopy guidance. Methods and Results:Children undergoing transcatheter ASD closure between 2002 and 2016 were included into this single center, r...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1155/2019/6598637

    authors: Ackermann S,Quandt D,Hagenbuch N,Niesse O,Christmann M,Knirsch W,Kretschmar O

    更新日期:2019-04-07 00:00:00

  • Previous cytomegalovirus infection and restenosis after aggressive angioplasty with provisional stenting.

    abstract:UNLABELLED:The aim of this study was to determine the impact of previous with cytomegalovirus (CMV) on restenosis after aggressive angioplasty with provisional stenting. DESIGN:We prospectively studied 78 consecutive patients scheduled for 6-month follow-up coronary angiography as part of the SIPS study. Anti-CMV IgG ...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1034/j.1600-6143.2003.08060.x

    authors: Mueller C,Hodgson JM,Bestehorn HP,Brutsche M,Perruchoud AP,Marsch S,Roskamm H,Buettner HJ

    更新日期:2003-08-01 00:00:00

  • Prediction of clinical outcomes in patients with unprotected left main trifurcation lesions treated by drug-eluting stents: importance of 2-stent technique and SYNTAX score.

    abstract:BACKGROUND:There were insufficient data on the prognosis of stenting for patients with trifurcated unprotected left main lesions (UPLMS). METHODS:From the SPEED (stents for percutaneous treatment of coronary artery disease) registry of all percutaneous coronary interventions (PCI) for all types of UPLMS, data of 44 pa...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2010.00569.x

    authors: Chen SL,Ye F,Zhang JJ,Hu ZY,Tian NL,Zhang JX,Kwan TW

    更新日期:2010-08-01 00:00:00

  • The real world experience of the everolimus-eluting coronary stent system: audit of everolimus-eluting coronary stents.

    abstract:AIMS:To investigate the safety and efficacy of everolimus-eluting stents (EES) in a real world population, including those with high-risk characteristics and complex lesions. METHODS:In this report, we analyze 2-year outcomes in 500 consecutive unselected patients treated with EES between April 2007 and March 2008. Al...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2011.00633.x

    authors: Aldous S,Smyth D,Blake J,McClean D,Elliott J

    更新日期:2011-06-01 00:00:00

  • Primary angioplasty in a patient with dextrocardia.

    abstract::Dextrocardia is a rare anomaly affecting 0.01% of newborns. We report on a case of a 60-year-old female with mirror-image dextrocardia who presented with an acute myocardial infarction and underwent primary angioplasty of the left circumflex artery. A review of the literature and technical challenges of the case will ...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2005.00350.x

    authors: Jauhar R,Gianos E,Baqai K,Roethel M,Kaplan BM

    更新日期:2005-04-01 00:00:00

  • Safety and efficacy of percutaneous intramyocardial bone marrow cell injection for chronic myocardial ischemia: Long-term results.

    abstract:BACKGROUND:Intramyocardial injection of bone marrow cells (BMC) in refractory angina patients with chronic myocardial ischemia has shown to be safe and improve clinical status during short-term follow-up. However, scarce data are available on long-term (>12 months) safety and efficacy. Therefore, the occurrence of clin...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/joic.12408

    authors: Rodrigo SF,Mann I,van Ramshorst J,Beeres SL,Zwaginga JJ,Fibbe WE,Bax JJ,Schalij MJ,Atsma DE

    更新日期:2017-10-01 00:00:00

  • Emergency transthoracic transapical mitral valve-in-valve implantation.

    abstract:OBJECTIVES:The valve-in-valve (VIV) technique is an emerging therapeutic option for patients with failure of previously implanted xenografts. We describe a balloon-expandable transthoracic transapical mitral VIV implantation in an emergency setting in a 69-year-old woman with dysfunction of the mitral bioprosthesis. M...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2011.00637.x

    authors: van Garsse LA,Gelsomino S,van Ommen V,Lucà F,Maessen J

    更新日期:2011-10-01 00:00:00

  • New technique for fenestration of the interatrial septum.

    abstract::Achieving controlled flow between the systemic and pulmonary venous circulations is desirable in many complex congenital heart diseases. This includes the Fontan circulation, primary pulmonary hypertension, double inlet ventricles, or hypoplastic left heart with obstruction to the atrioventricular valve. As no specifi...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2006.00155.x

    authors: Sivaprakasam M,Kiesewetter C,Veldtman GR,Salmon AP,Vettukattil J

    更新日期:2006-08-01 00:00:00

  • Cutaneous cancers in an interventional cardiologist: a cautionary tale.

    abstract::This case report documents the presentation of a disabling ionizing radiation (IR)-related illness (multiple basal cell carcinoma [BCC] syndrome) in a 50-year-old interventional cardiologist. This case emphasizes the need for interventionalists to: (1) understand the occupational hazards of IR; (2) recognize the failu...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2010.00610.x

    authors: Eagan JT Jr,Jones CT

    更新日期:2011-02-01 00:00:00

  • Holmium YAG laser coronary angioplasty with multifiber catheters.

    abstract::Excimer lasers are being extensively used for coronary angioplasty along with multifiber over-the-wire catheters. To determine whether another wavelength could be an alternative, the laser-tissue interaction and the clinical usefulness of an infrared laser were studied. The laser consisted of a Holmium YAG pulsed la...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.1991.tb00790.x

    authors: Geschwind HJ,Tomaru T,Nakamura F,Kvasnicka J

    更新日期:1991-01-01 00:00:00