Is it safe to close ASD with the guidance of transthoraxic echocardiography in pediatric population "ten years' experience of a single center".

Abstract:

OBJECTIVE:Main purpose of this study is to emphasize the usage and safety of transthoracic echocardiography (TTE) in percutaneous atrial septal defect (ASD) closure in appropriate pediatric cases. BACKGROUND:Nowadays, percutaneous closure is preferred as treatment modality for ASD in pediatric age group. METHODS:Between the dates December 2003-August 2013; 340 patients whose ASD were closed included in this study. Physical examination, electrocardiogram, TTE were done before the procedure, at the 24th hour, 1st and 6th month after the procedure. After the 6th month, routine control was done annually. Transesophageal echocardiography (TEE) was performed in 184 cases with large, multifenestrated ASD and when TTE views were poor in quality. We selected the 201 patients whose ASD diameter between 10-20 mm and formed 2 homogeneous groups according to the type of echocardiography used (TEE or TTE) in order to compare the role of echocardiography. RESULTS:The demographic features of patients of 2 groups were similar. There was not any statistically difference between ASD, balloon sizing diameters between the groups. No statistically significant difference in the success, complication, and residual shunt rates was found between the groups. Procedure, fluoroscopy time, and amount were significantly higher in TEE group. When hemodynamic variables except pulmonary blood flow to systemic blood flow (Qp/Qs; right-left atrium mean pressure, pulmonary vascular resistance, and peak-mean pulmonary arterial pressure) were compared, there was not statistically difference. CONCLUSION:TEE is an invasive procedure and requires general anesthesia, therefore, it should not be done routinely in ASD but only in selected cases. If the size and the anatomy of ASD is appropriate, TTE should be preferred primarily in percutaneous ASD closure.

journal_name

J Interv Cardiol

authors

Baykan A,Pamukcu O,Ozyurt A,Argun M,Onan SH,Sezer S,Uzum K,Narin N

doi

10.1111/joic.12197

subject

Has Abstract

pub_date

2015-04-01 00:00:00

pages

172-9

issue

2

eissn

0896-4327

issn

1540-8183

journal_volume

28

pub_type

杂志文章
  • Catheter closure of the persistent foramen ovale: mid-term results in 162 patients.

    abstract::Four different types of occluder systems were used to close a persistent foramen ovale (PFO) in 162 patients with paradoxical embolic events. Ninety-eight patients had ischemic stroke, 60 transient ischemic attacks (TIA) or prolonged reversible ischemic neurological deficit (PRIND), and 4 had peripheral arterial embol...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2001.tb00740.x

    authors: Beitzke A,Schuchlenz H,Gamillscheg A,Stein JI,Wendelin G

    更新日期:2001-04-01 00:00:00

  • Long-term safety and effectiveness of drug-eluting stents compared to bare metal stents in ST elevation myocardial infarction: findings from the Guthrie Health Off-label Stent (GHOST) Registry.

    abstract:BACKGROUND:Multiple randomized trials and observational studies have shown drug-eluting stents (DES) to be safe and effective at 3-year follow-up in stent thrombosis (ST)-segment elevation myocardial infarction (STEMI) treated with primary percutaneous coronary intervention (PCI). However, outcomes data beyond 3-4 year...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2011.00703.x

    authors: Sattur S,Orshaw P,Boura J,Harjai KJ

    更新日期:2012-04-01 00:00:00

  • Changes in Index of Microcirculatory Resistance during PCI in the Left Anterior Descending Coronary Artery in Relation to Total Length of Implanted Stents.

    abstract:Aim:To investigate the relationship between stent length and changes in microvascular resistance during PCI in stable coronary artery disease (CAD). Methods and Results:We measured fractional flow reserve (FFR), index of microcirculatory resistance (IMR), and coronary flow reserve (CFR) before and after stenting in 42...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1155/2019/1397895

    authors: Ekenbäck C,Jokhaji F,Östlund-Papadogeorgos N,Mir-Akbari H,Linder R,Witt N,Törnerud M,Samad B,Persson J

    更新日期:2019-12-01 00:00:00

  • Coronary angiography with 5 French diagnostic catheters may miss an ostial left main stenosis.

    abstract::Critical ostial left main disease may lead rapidly to sudden death and is, therefore, of paramount importance to diagnose. While the number of cardiac catheterizations is increasing, government and third party reimbursement sources are imposing pressure to perform more studies in an outpatient setting, as the economi...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.1993.tb00845.x

    authors: Feld H,Fisher M,Shani J

    更新日期:1993-06-01 00:00:00

  • Simple technique to ensure coaxial guidewire positioning for placement of iliac limb of modular aortic endograft.

    abstract::Endovascular abdominal aortic aneurysm repair using a modular bifurcated stent-graft requires the initial placement of the main component in the infrarenal aorta, followed by insertion of additional iliac stent-graft(s) to exclude aneurysm and to securely affix the device. Placement of the contralateral iliac componen...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章,评审

    doi:10.1034/j.1600-0854.2003.8046.x

    authors: Dawson DL,Terramani TT,Loberman Z,Lumsden AB,Lin PH

    更新日期:2003-06-01 00:00:00

  • Drug-eluting stents during ST-segment elevation acute myocardial infarction: a critical analysis.

    abstract::Primary percutaneous coronary intervention is the preferred reperfusion therapy for ST-segment elevation acute myocardial infarction patients within 12 hours of symptom-onset. Routine stent implantation during the procedure significantly reduces the rate of target vessel revascularization, although restenosis still re...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章,评审

    doi:10.1111/j.1540-8183.2011.00650.x

    authors: Andrade PB,Tebet MA,Silva FS,Andrade MV,Labrunie A,Piva e Mattos LA

    更新日期:2011-10-01 00:00:00

  • Network meta-analysis comparing iFR versus FFR versus coronary angiography to drive coronary revascularization.

    abstract:AIMS:Instantaneous free-wave ratio (iFR) has been recently demonstrated non-inferior to fractional flow reserve (FFR) to drive coronary revascularization; however, no study has compared iFR versus coronary angiography (CA). We performed a network meta-analysis to evaluate efficacy and safety of iFR- versus CA-guided st...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章,meta分析

    doi:10.1111/joic.12551

    authors: Verardi R,Fioravanti F,Barbero U,Conrotto F,Omedè P,Montefusco A,Moretti C,D'Amico M,Rinaldi M,Escaned J,D'Ascenzo F

    更新日期:2018-12-01 00:00:00

  • Use of stent grafts and coils in vessel rupture and perforation.

    abstract::Vessel rupture and perforation are important complications of percutaneous treatment of coronary and peripheral arterial disease. These complications can result in abrupt vessel closure, distal organ injury, bleeding into the surrounding tissue, and death. Prompt management of such complications is therefore criticall...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章,评审

    doi:10.1111/j.1540-8183.2007.00302.x

    authors: Yeo KK,Rogers JH,Laird JR

    更新日期:2008-02-01 00:00:00

  • Polymer-based paclitaxel-eluting stents in percutaneous coronary intervention: a review of the TAXUS trials.

    abstract::Drug-eluting stents have altered the practice of interventional cardiology by dramatically reducing the risk of angiographic and clinical restenosis following percutaneous coronary intervention. Based on extensive preclinical study and clinical trial data, the polymer-based, slow rate-release paclitaxel-eluting TAXUS ...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章,评审

    doi:10.1111/j.1540-8183.2004.04040.x

    authors: Halkin A,Stone GW

    更新日期:2004-10-01 00:00:00

  • Relationship between microvascular resistance and perfusion in patients with reperfused acute myocardial infarction.

    abstract:UNLABELLED:Despite its prognostic importance, accurate assessment of microvascular perfusion in patients with ST elevation acute myocardial infarction (STEMI) is difficult. As a new tool, the index of microvascular resistance (IMR) measurement provides us a new opportunity for interrogating microvascular condition afte...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2007.00274.x

    authors: Sezer M,Umman B,Okcular I,Nisanci Y,Umman S

    更新日期:2007-10-01 00:00:00

  • The evolving role of glycoprotein IIb/IIIa inhibitor therapy in contemporary care of acute coronary syndrome patients.

    abstract::Results from clinical trials of glycoprotein IIb/IIIa(GPIIb/IIIa) inhibitors during the past decade have established their current role in the treatment of non-ST-segment elevation acute coronary syndrome and in percutaneous coronary interventions. However, there are still unanswered questions on optimal use of GPIIb/...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章,评审

    doi:10.1111/j.1540-8183.2006.00182.x

    authors: Tricoci P,Peterson ED

    更新日期:2006-10-01 00:00:00

  • Observance of antiplatelet therapy after stent implantation in patients under chronic oral anticoagulant treatment.

    abstract:PURPOSE:Patients undergoing coronary stenting must take dual antiplatelet therapy during a variable period. The combination of chronic oral anticoagulants (COA) with antiplatelet therapy has been related to an increased risk of hemorrhage. The aim of this study was to evaluate the level of the antiplatelet therapy obse...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2008.00354.x

    authors: Valencia J,Mainar V,Bordes P,Pineda J,Gómez S,Sogorb F

    更新日期:2008-06-01 00:00:00

  • Left atrial anatomy and patient-related factors associated with adverse outcomes with the watchman device-a real world experience.

    abstract:OBJECTIVE:This study sought to identify patient and left atrial morphology specific factors associated with early complications for left atrial appendage occlusion with the Watchman™ (Boston Scientific, Natick, MA) device. BACKGROUND:Oral anticoagulation (OAC) is recommended for patients with atrial fibrillation, howe...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/joic.12374

    authors: Murarka S,Lazkani M,Moualla S,Verma DR,Pershad A

    更新日期:2017-04-01 00:00:00

  • Experience with a novel retrograde wiring technique for coronary chronic total occlusion.

    abstract:OBJECTIVES:We report our evaluation of a novel retrograde wiring technique known as the Rendezvous method. BACKGROUND:Different strategies of retrograde approaches can be used to improve the success rate of recanalization of coronary chronic total occlusion (CTO). We previously introduced the Rendezvous technique as a...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章,多中心研究

    doi:10.1111/joic.12031

    authors: Kim MH,Yu LH,Tanaka H,Mitsudo K

    更新日期:2013-06-01 00:00:00

  • Recanalization of native superficial femoral artery chronic total occlusion after failed femoropopliteal bypass in patients with critical limb ischemia.

    abstract:OBJECTIVES:This study aimed to examine the outcomes of endovascular recanalization for native superficial femoral artery (SFA) chronic total occlusion (CTO) in patients with critical limb ischemia (CLI) after femoropopliteal bypass failure with limited surgical revascularization options. BACKGROUND:Endovascular recana...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/joic.12470

    authors: Li Z,Feng R,Qin F,Zhao Z,Yuan L,Li Y,Liu J,Feng J,Zhou J,Bao J,Jing Z

    更新日期:2018-04-01 00:00:00

  • Successful thrombus removal using 6Fr hydrolyser thrombectomy catheter in acute myocardial infarction via radial artery.

    abstract::The 6Fr Hydrolyser thrombectomy catheter for acute myocardial infarction (AMI) successfully removed a massive thrombus in the coronary artery in three patients. The 6Fr Hydrolyser catheter could be advanced into the right coronary artery with bare-wire methods via a 6Fr sheath at the radial artery. This approach sugge...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2001.tb00356.x

    authors: Yingfeng L,Nakamura S,Tanigawa J,Nakagawa A,Kitano K,Kitagawa M,Takahashi H,Matoba Y,Katoh O

    更新日期:2001-08-01 00:00:00

  • Imaging behind occluded areas with an iatrogenic perforated balloon: A safe, practical, and simple new method of visualizing the distal lumen in total occlusion.

    abstract:OBJECTIVE:In the present study, we investigated the effectiveness and reliability of a new method that reveals whether guidewire advanced distal to the lesion is in the lumen in patients with acute (ATO) or chronic coronary total occlusion (CTO). METHODS:Forty-one patients with symptomatic ATO and 22 patients with CTO...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/joic.12444

    authors: Balaban Y,Bektaş O,Bayramoğlu A,Gümrükçüoğlu HA,Kayışoğlu AH

    更新日期:2017-12-01 00:00:00

  • Effectiveness of the proximal optimization technique for longitudinal stent elongation caused by post-balloon dilatation.

    abstract:OBJECTIVES:To evaluate the effectiveness of the proximal optimization technique (POT) to prevent longitudinal stent elongation. BACKGROUND:The mechanism of stent elongation, which occurs after post-balloon dilation, is still unclear. METHODS:A total of 103 lesions treated with optical coherence tomography guided coro...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/joic.12543

    authors: Matsuda Y,Ashikaga T,Sasaoka T,Hatano Y,Umemoto T,Yamamoto T,Maejima Y,Hirao K

    更新日期:2018-10-01 00:00:00

  • Advantages and disadvantages of coils for transcatheter closure of patent ductus arteriosus.

    abstract::Different coils have been used to close the patient ductus arteriosus (PDA). In small- and moderate-sized PDA, coils are an adequate alternative to surgery and/or to other devices. The aim of the study is to review and discuss the advantages and disadvantages of using coils (excluding PFM coils PFM Medical, Germany) t...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1046/j.1540-8183.2003.08029.x

    authors: Galal MO

    更新日期:2003-04-01 00:00:00

  • Ultrasound-Guided Percutaneous Balloon Aortic Valvuloplasty for Aortic Stenosis.

    abstract::Percutaneous balloon aortic valvuloplasty (PBAV), which is used to treat symptomatic aortic stenosis, requires ionizing radiation and contrast agent for imaging guidance. The aim of the study is to evaluate the feasibility and effectiveness of ultrasound-guided PBAV in patients with aortic stenosis. This case series i...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1155/2020/8086796

    authors: Li Y,Pang K,Liu Y,Li M,Wang H

    更新日期:2020-03-16 00:00:00

  • Diabetic retinopathy and coronary implantation of sirolimus-eluting stents.

    abstract:INTRODUCTION:The prognostic value of identifying the retinal status of diabetic patients undergoing coronary implantation of drug-eluting stents is unknown. METHODS:We evaluated the outcomes of 318 consecutive patients undergoing implantation of sirolimus-eluting stents for coronary artery disease. Patients were divid...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2007.00252.x

    authors: Ohno T,Takamoto S,Ando J,Morita T,Fujita H,Hirata Y,Shigeeda T,Hirose A,Nagai R

    更新日期:2007-04-01 00:00:00

  • Drug-Coated Balloons: A Safe and Effective Alternative to Drug-Eluting Stents in Small Vessel Coronary Artery Disease.

    abstract:BACKGROUND:Drug-coated balloons (DCB) have been used to treat de novo small vessel coronary disease (SVD), with promising results and shorter dual antiplatelet therapy (DAPT) duration compared to drug-eluting stents (DES). We compared safety and effectiveness of the two treatments at 1 year. METHODS:We reviewed 3,613 ...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/joic.12333

    authors: Sinaga DA,Ho HH,Watson TJ,Sim A,Nyein TT,Jafary FH,Loh JK,Ooi YW,Tan JK,Ong PJ

    更新日期:2016-10-01 00:00:00

  • Transatrial access to the normal pericardial space for local cardiac therapy: preclinical safety testing with aspirin and pulmonary artery hypertension.

    abstract::The reliability, rapidity, and safety of nonsurgical, transatrial pericardial access for local cardiac therapy have been demonstrated in healthy animals. Since many patients take aspirin or have increased right-sided pressures, we evaluated the procedure's safety under these conditions. Transatrial pericardial access ...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2001.tb00364.x

    authors: Pulerwitz TC,Waxman S,Rowe KA,Quist WC,Lipinska I,Verrier RL

    更新日期:2001-10-01 00:00:00

  • Do complaints of amaurosis fugax and blurred vision after transcatheter device closure of atrial septal defect indicate microemboli to retinal vessels?

    abstract::Atrial septal defect (ASD) is a common diagnosis in young adults with congenital heart disease. The aim of this study was to determine if ocular symptoms following percutaneous treatment are due to microemboli. The study group included 20 adult patients (9 men, 11 women, mean age 57.2 years) with ASD who had undergone...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2005.00392.x

    authors: Ehrlich R,Mutzmacher L,Averbuch L,Dotan G,Hirsh R

    更新日期:2005-02-01 00:00:00

  • Holmium YAG laser coronary angioplasty with multifiber catheters.

    abstract::Excimer lasers are being extensively used for coronary angioplasty along with multifiber over-the-wire catheters. To determine whether another wavelength could be an alternative, the laser-tissue interaction and the clinical usefulness of an infrared laser were studied. The laser consisted of a Holmium YAG pulsed la...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.1991.tb00790.x

    authors: Geschwind HJ,Tomaru T,Nakamura F,Kvasnicka J

    更新日期:1991-01-01 00:00:00

  • Transcatheter Aortic Valve Replacement: 2015 in Review.

    abstract::Transcatheter aortic valve replacement (TAVR) has emerged as an attractive option for patients with severe symptomatic aortic stenosis (AS) who are either at high risk or extreme risk for surgical aortic valve replacement (SAVR). This article summarizes the major advances in TAVR that were published or reported in 201...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章,评审

    doi:10.1111/joic.12274

    authors: Harjai KJ,Grines CL,Leon MB

    更新日期:2016-02-01 00:00:00

  • Valve-in-valve transcatheter aortic valve implantation with CoreValve/Evolut R© for degenerated small versus bigger bioprostheses.

    abstract:OBJECTIVES:We present our single center experience with Medtronic CoreValve and Evolut R regarding procedural outcome and 3 years follow-up in patients with degenerated bioprostheses. METHODS:From 1645 patients who underwent transfemoral TAVI at our institution between February 2009 and December 2016, 37 patients with...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/joic.12498

    authors: Scholtz S,Piper C,Horstkotte D,Gummert J,Ensminger SM,Börgermann J,Scholtz W

    更新日期:2018-06-01 00:00:00

  • Transcranial doppler quantification of residual shunt after percutaneous patent foramen ovale closure: efficacy of the GORE(®) HELEX septal occluder.

    abstract:BACKGROUND:Ideally, percutaneous, mechanical closure of defects of the atrial septum should completely resolve shunt. To achieve this goal, more information is needed about the factors associated with device failure. METHODS:Consecutive patients with cryptogenic neurological events who had severe baseline Valsalva shu...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2011.00644.x

    authors: Sorensen SG,Smout R,Spruance SL

    更新日期:2011-08-01 00:00:00

  • Burr erosion in rotational ablation of metallic coronary stent: an electron microscopic study.

    abstract:BACKGROUND:Rotational atherectomy is used to penetrate resistant coronary lesions from standard balloon dilatation. These lesions may contain heavy calcification or metallic components from previously implanted stents. When the rotablator device is utilized to ablate an undilatable lesion containing metallic stent comp...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2010.00543.x

    authors: Ho PC,Weatherby TM,Dunlap M

    更新日期:2010-06-01 00:00:00

  • Single-center experience with the HELEX septal occluder for closure of atrial septal defects in children.

    abstract::Catheter closure of atrial septal defects (ASDs) is an accepted procedure among pediatric cardiologists. We report our early experience with the newest of these devices in clinical trials in the United States. Between April and October 2001, 14 patients were enrolled in an FDA phase II multicenter trial comparing the ...

    journal_title:Journal of interventional cardiology

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1046/j.1540-8183.2003.08005.x

    authors: Vincent RN,Raviele AA,Diehl HJ

    更新日期:2003-02-01 00:00:00