Imaging behind occluded areas with an iatrogenic perforated balloon: A safe, practical, and simple new method of visualizing the distal lumen in total occlusion.

Abstract:

OBJECTIVE:In the present study, we investigated the effectiveness and reliability of a new method that reveals whether guidewire advanced distal to the lesion is in the lumen in patients with acute (ATO) or chronic coronary total occlusion (CTO). METHODS:Forty-one patients with symptomatic ATO and 22 patients with CTO who were admitted into our catheterization laboratory between January 2016 and March 2017 were included. In patients in whom antegrade filling could not be demonstrated after passing 0.014″ guidewire beyond the total lesion, a 1.25 × 15 mm balloon was punctured with a needle outside the operative field to visualize the total lesion. This perforated balloon was then used to deliver an opaque substance through this hole to visualize the distal part. RESULTS:The mean age of our 63 patients was 66 ± 12 years. They had diabetes (57%), hypertension (100%), and a history of PCI (85%). The mean procedural time was 27 ± 6.8 min, and the mean volume of contrast material used was 93.9 ± 24 mL. This technique was 100% successful in accurately demonstrating the distal lumen and preventing complications. CONCLUSION:This new method we developed is much simpler and more useful than other methods for visualization of the true lumen because we can re-orient the balloon at the time of opaque injection and use 190 cm guidewire without additional costs. Additionally, one balloon is sufficient for the operation.

journal_name

J Interv Cardiol

authors

Balaban Y,Bektaş O,Bayramoğlu A,Gümrükçüoğlu HA,Kayışoğlu AH

doi

10.1111/joic.12444

subject

Has Abstract

pub_date

2017-12-01 00:00:00

pages

544-549

issue

6

eissn

0896-4327

issn

1540-8183

journal_volume

30

pub_type

杂志文章
  • Comparison of the safety and efficacy of biodegradable polymer biolimus-eluting stents and durable polymer everolimus-eluting stents: propensity score-matched analysis.

    abstract:OBJECTIVES:We investigated and compared the clinical outcomes between biodegradable polymer biolimus-eluting stents (BES) and durable polymer everolimus-eluting stents (EES) in a single-center prospective registry. BACKGROUND:There is limited data regarding the safety and efficacy of the biodegradable BES compared to ...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/joic.12140

    authors: Lee JH,Lee JW,Youn YJ,Ahn MS,Ahn SG,Kim JY,Yoo BS,Lee SH,Choi E,Yoon J

    更新日期:2014-08-01 00:00:00

  • Implementation of the transradial approach for coronary procedures is not associated with an elevated complication rate and elevated radiation patient exposure.

    abstract:BACKGROUND:The transradial approach for coronary procedures is associated with a low complication rate, but specific training is considered mandatory. METHODS:Procedural characteristics (contrast dye: CD; fluoroscopy time: FT, patient radiation dose: RD) and local complication rates were prospectively assessed in 784 ...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2010.00603.x

    authors: Lehmann R,Ehrlich JR,Weber V,de Rosa S,Gotarda MN,Schächinger V,Zeiher AM,Fichtlscherer S

    更新日期:2011-02-01 00:00:00

  • Prediction of clinical outcomes in patients with unprotected left main trifurcation lesions treated by drug-eluting stents: importance of 2-stent technique and SYNTAX score.

    abstract:BACKGROUND:There were insufficient data on the prognosis of stenting for patients with trifurcated unprotected left main lesions (UPLMS). METHODS:From the SPEED (stents for percutaneous treatment of coronary artery disease) registry of all percutaneous coronary interventions (PCI) for all types of UPLMS, data of 44 pa...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2010.00569.x

    authors: Chen SL,Ye F,Zhang JJ,Hu ZY,Tian NL,Zhang JX,Kwan TW

    更新日期:2010-08-01 00:00:00

  • Effectiveness of the proximal optimization technique for longitudinal stent elongation caused by post-balloon dilatation.

    abstract:OBJECTIVES:To evaluate the effectiveness of the proximal optimization technique (POT) to prevent longitudinal stent elongation. BACKGROUND:The mechanism of stent elongation, which occurs after post-balloon dilation, is still unclear. METHODS:A total of 103 lesions treated with optical coherence tomography guided coro...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/joic.12543

    authors: Matsuda Y,Ashikaga T,Sasaoka T,Hatano Y,Umemoto T,Yamamoto T,Maejima Y,Hirao K

    更新日期:2018-10-01 00:00:00

  • Percutaneous balloon atrioseptostomy for left heart discharge in extracorporeal life support patients with persistent pulmonary edema.

    abstract:AIMS:In severe myocardial dysfunction, extracorporeal life support (ECLS) can preserve organ perfusion. Occasionally, the high resulting afterload can lead to refractory pulmonary edema. We report our experience with percutaneous balloon atrioseptostomy used in this circumstance to discharge the left heart and prevent ...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2011.00681.x

    authors: Bignon M,Roule V,Dahdouh Z,Sabatier R,Lognoné T,Malcor G,Idali M,Ivascau C,Massetti M,Grollier G

    更新日期:2012-02-01 00:00:00

  • Interventional occlusion of congenital vascular malformations with the detachable Cook coil system.

    abstract:INTRODUCTION:Nonsurgical closure of pathologic vascular communications can be achieved by coil embolization. Different systems used in patients with congenital heart disease (e.g., patent ductus arteriosus) allow controlled release of the devices. However, they are too stiff for coil occlusion of small or tortuous vess...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2001.tb00338.x

    authors: Sieverding L,Breuer J

    更新日期:2001-06-01 00:00:00

  • Transcranial doppler quantification of residual shunt after percutaneous patent foramen ovale closure: efficacy of the GORE(®) HELEX septal occluder.

    abstract:BACKGROUND:Ideally, percutaneous, mechanical closure of defects of the atrial septum should completely resolve shunt. To achieve this goal, more information is needed about the factors associated with device failure. METHODS:Consecutive patients with cryptogenic neurological events who had severe baseline Valsalva shu...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2011.00644.x

    authors: Sorensen SG,Smout R,Spruance SL

    更新日期:2011-08-01 00:00:00

  • Crushed clopidogrel administered via nasogastric tube has faster and greater absorption than oral whole tablets.

    abstract:OBJECTIVES:To compare the absorption of 300 mg clopidogrel administered crushed via nasogastric (NG) tube versus whole tablets taken orally in healthy volunteers. BACKGROUND:Earlier antiplatelet therapy has proven benefits in treatment of myocardial infarction and in patients undergoing PCI. Aspirin can be delivered e...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2009.00475.x

    authors: Zafar MU,Farkouh ME,Fuster V,Chesebro JH

    更新日期:2009-08-01 00:00:00

  • Polymer-based paclitaxel-eluting stents in percutaneous coronary intervention: a review of the TAXUS trials.

    abstract::Drug-eluting stents have altered the practice of interventional cardiology by dramatically reducing the risk of angiographic and clinical restenosis following percutaneous coronary intervention. Based on extensive preclinical study and clinical trial data, the polymer-based, slow rate-release paclitaxel-eluting TAXUS ...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章,评审

    doi:10.1111/j.1540-8183.2004.04040.x

    authors: Halkin A,Stone GW

    更新日期:2004-10-01 00:00:00

  • Burr erosion in rotational ablation of metallic coronary stent: an electron microscopic study.

    abstract:BACKGROUND:Rotational atherectomy is used to penetrate resistant coronary lesions from standard balloon dilatation. These lesions may contain heavy calcification or metallic components from previously implanted stents. When the rotablator device is utilized to ablate an undilatable lesion containing metallic stent comp...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2010.00543.x

    authors: Ho PC,Weatherby TM,Dunlap M

    更新日期:2010-06-01 00:00:00

  • Recanalization of native superficial femoral artery chronic total occlusion after failed femoropopliteal bypass in patients with critical limb ischemia.

    abstract:OBJECTIVES:This study aimed to examine the outcomes of endovascular recanalization for native superficial femoral artery (SFA) chronic total occlusion (CTO) in patients with critical limb ischemia (CLI) after femoropopliteal bypass failure with limited surgical revascularization options. BACKGROUND:Endovascular recana...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/joic.12470

    authors: Li Z,Feng R,Qin F,Zhao Z,Yuan L,Li Y,Liu J,Feng J,Zhou J,Bao J,Jing Z

    更新日期:2018-04-01 00:00:00

  • Midterm Clinical Impacts of Biodegradable Polymer Everolimus-Eluting Stents Compared with Durable Polymer Everolimus-Eluting Stents: A 3-Year Propensity-Matched Study.

    abstract:Objectives:Our aim was to evaluate the safety and efficacy of biodegradable polymer everolimus-eluting stents (BP-EES) compared with durable polymer everolimus-eluting stents (DP-EES) in midterm. Background:There are few data about midterm clinical outcomes of BP-EES compared with DP-EES. Methods and Results:Between ...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1155/2020/2869303

    authors: Matsuda H,Kagase A,Tokuda T,Ochiumi Y,Murata A,Suzuki Y,Ito T

    更新日期:2020-04-20 00:00:00

  • New catheter-based technology for the treatment of restenosis.

    abstract::Catheter-based vascular interventions have been in development worldwide for several decades, leading to remarkable progress in device technology. Mechanical interventional devices, such as angioplasty balloons, atherectomy devices, and stents, were invented and have contributed greatly to the treatment of atheroscler...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章,评审

    doi:10.1111/j.1540-8183.2002.tb01070.x

    authors: Kataoka T,Honda Y,Bonneau HN,Yock PG,Fitzgerald PJ

    更新日期:2002-10-01 00:00:00

  • Immediate and long-term outcome of recanalization of chronic total coronary occlusions.

    abstract::Eighty-three consecutive patients with 85 coronary total occlusions undergoing coronary angioplasty were retrospectively studied. Patients were divided into two groups according to the occlusion age that was < 30 days (subacute total occlusion [STO]: 25 patients; range 1-30 days) or > 30 days (chronic total occlusion ...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2002.tb01052.x

    authors: Piscione F,Galasso G,Maione AG,Pisani A,Golino P,Leosco D,Indolfi C,Chiariello M

    更新日期:2002-06-01 00:00:00

  • Predictors of recurrent in-stent restenosis after beta-radiation: An analysis from the START 40/20 trial.

    abstract:OBJECTIVE:The purpose of this study was to identify potential predictors, including clinical, procedural, angiographic, and intravascular ultrasound (IVUS) parameters, for recurrent in-stent restenosis (ISR) following beta-radiation 90Strontium/Yttrium (90Sr/Y) in a large multicenter trial. BACKGROUND:Although adjunct...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章,多中心研究

    doi:10.1111/j.1540-8183.2006.00188.x

    authors: Kaneda H,Honda Y,Morino Y,Lansky AJ,Yock PG,Bonan R,Fitzgerald PJ

    更新日期:2006-10-01 00:00:00

  • Simple technique to ensure coaxial guidewire positioning for placement of iliac limb of modular aortic endograft.

    abstract::Endovascular abdominal aortic aneurysm repair using a modular bifurcated stent-graft requires the initial placement of the main component in the infrarenal aorta, followed by insertion of additional iliac stent-graft(s) to exclude aneurysm and to securely affix the device. Placement of the contralateral iliac componen...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章,评审

    doi:10.1034/j.1600-0854.2003.8046.x

    authors: Dawson DL,Terramani TT,Loberman Z,Lumsden AB,Lin PH

    更新日期:2003-06-01 00:00:00

  • Comparison of three treatment strategies for patients with triple-vessel coronary disease and left ventricular dysfunction.

    abstract:INTRODUCTION:Current guidelines recommend coronary artery bypass grafting (CABG) for patients with multivessel coronary disease and left ventricular (LV) dysfunction. However, some patients undergo percutaneous coronary intervention (PCI) or solely medical therapy (MT) in actual practice. The comparison of long-term ou...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/joic.12497

    authors: Jiang L,Xu L,Song L,Gao Z,Tian J,Sun K,Yu H,Xu B,Song L,Yuan J

    更新日期:2018-06-01 00:00:00

  • Long-term clinical and angiographic results of Sirolimus-Eluting Stent in Complex Coronary Chronic Total Occlusion Revascularization: the SECTOR registry.

    abstract:BACKGROUND:Drug-eluting stents showed a better angiographic and clinical outcome in comparison with bare metal stent in chronic total occlusions (CTOs) percutaneous revascularization, however, great concerns still remain regarding the rate of restenosis and reocclusion in comparison with nonocclusive lesions. AIM:To e...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2011.00648.x

    authors: Galassi AR,Tomasello SD,Costanzo L,Campisano MB,Barrano G,Tamburino C

    更新日期:2011-10-01 00:00:00

  • A hybrid surgical transcatheter strategy for treating severe para-right atrioventricular valvular regurgitation in a patient with left atrial isomerism.

    abstract::Paravalvular leaks are a recognized complication of valve replacement surgery. We report a 47-year-old man with left atrial isomerism, interrupted left sided inferior caval vein with unilateral left sided superior caval vein, a common atrium, and anomalous pulmonary venous connection to the coronary sinus, who had rec...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2007.00290.x

    authors: Kalantre A,Vettukattil J,Haw M,Veldtman GR

    更新日期:2007-12-01 00:00:00

  • Periprocedural management and in-hospital outcome of patients with indication for oral anticoagulation undergoing coronary artery stenting.

    abstract:PURPOSE:In patients on oral anticoagulation (OAC) undergoing coronary stenting (PCI-S), procedural management and in-hospital outcome have never been specifically and prospectively investigated. Also, the contribution of early bleeding to the relevant hemorrhagic rate reported at follow-up with triple therapy of OAC, a...

    journal_title:Journal of interventional cardiology

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1111/j.1540-8183.2009.00468.x

    authors: Rubboli A,Colletta M,Valencia J,Capecchi A,Franco N,Zanolla L,La Vecchia L,Piovaccari G,Di Pasquale G,WARfarin and Coronary STENTing (WAR-STENT) Study Group.

    更新日期:2009-08-01 00:00:00

  • In-stent neoatherosclerosis and tissue characteristics of restenotic lesions following implantation of second generation drug-eluting stents in unrestricted coronary lesions: Optical frequency domain imaging study.

    abstract:BACKGROUND:Differences in stent platform, polymer coatings, and antirestenotic drugs among the current in use second-generation drug-eluting stents (G2-DESs) may induce significant variations in neointimal response and vascular healing, which may impact the prevalence of neoatherosclerosis (NA) and morphological appear...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/joic.12375

    authors: Sabbah M,Kadota K,El-Eraky A,Kamal HM,Abdellah AT,El Hawary A

    更新日期:2017-06-01 00:00:00

  • The use of radiofrequency energy in pediatric cardiology.

    abstract::The use of radiofrequency energy for the treatment of supraventricular tachycardia in pediatric patients has gained widespread acceptance, especially for tachyarrhythmias associated with palpitations, dizziness, presyncope or syncope, cardiomyopathy, and cardiac arrest. Ablation of the substrate supporting atrioventri...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章,评审

    doi:10.1111/j.1540-8183.1995.tb00583.x

    authors: Dorostkar PC,Dick M 2nd

    更新日期:1995-10-01 00:00:00

  • Is direct stent implantation without predilatation safe? Acute and long-term outcome.

    abstract::Direct stenting could potentially lead to a reduction in dissections, time, and restenosis at 6-month follow-up. Using the premounted Palmaz-Schatz Crown stent elective stenting was performed without predilatation in 61 consecutive patients who were compared with a control group of provisional stenting. All patients u...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2002.tb01101.x

    authors: Rahel BM,Suttorp MJ,Ten Berg JM,Bal ET,Ernst SM,Mast EG,Kelder JC,Plokker HW

    更新日期:2002-08-01 00:00:00

  • Long-term clinical and angiographic follow-up after placement of Palmaz-Schatz coronary stent: a single center experience.

    abstract::The purpose of this study is to evaluate long-term clinical and angiographic follow-up results after placement of the Palmaz-Schatz stent and angiographic follow-up results of repeat interventions for stent restenosis. From June 1990 to September 1993, the Palmaz-Schatz stent was placed in 411 patients, 427 lesions. ...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.1994.tb00896.x

    authors: Kimura T,Tamura T,Yokoi H,Nobuyoshi M

    更新日期:1994-04-01 00:00:00

  • Diagnostic accuracy of instantaneous wave free-ratio in clinical practice.

    abstract:AIMS:To evaluate the correlation between iFR and FFR in real-world clinical practice. METHODS AND RESULTS:Retrospective, single-centre study of 229 consecutive pressure-wire studies (np  = 158). Real-time iFR and FFR measurements were performed for angiographically borderline stenoses. Functionally significant stenose...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/joic.12422

    authors: Ding WY,Nair S,Appleby C

    更新日期:2017-12-01 00:00:00

  • Determining the in-hospital cost of bleeding in patients undergoing percutaneous coronary intervention.

    abstract:BACKGROUND:The economic impact of bleeding in the setting of nonemergent percutaneous coronary intervention (PCI) is poorly understood and complicated by the variety of bleeding definitions currently employed. This retrospective analysis examines and contrasts the in-hospital cost of bleeding associated with this proce...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2009.00431.x

    authors: Ewen EF,Zhao L,Kolm P,Jurkovitz C,Fidan D,White HD,Gallo R,Weintraub WS

    更新日期:2009-06-01 00:00:00

  • Transcatheter device closure of interatrial septal defects in patients with hypoxia.

    abstract:BACKGROUND:There has been growing interest in transcatheter closure of interatrial septal defects (IASDs) for a variety of indications, but reports are limited in patients with hypoxia from right-to-left shunting. METHODS:Between August 2000 and October 2004, 181 patients were referred to our institution for elective ...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2005.00043.x

    authors: Ilkhanoff L,Naidu SS,Rohatgi S,Ross MJ,Silvestry FE,Herrmann HC

    更新日期:2005-08-01 00:00:00

  • Cutaneous cancers in an interventional cardiologist: a cautionary tale.

    abstract::This case report documents the presentation of a disabling ionizing radiation (IR)-related illness (multiple basal cell carcinoma [BCC] syndrome) in a 50-year-old interventional cardiologist. This case emphasizes the need for interventionalists to: (1) understand the occupational hazards of IR; (2) recognize the failu...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2010.00610.x

    authors: Eagan JT Jr,Jones CT

    更新日期:2011-02-01 00:00:00

  • Late catch-up phenomenon associated with stent fracture after sirolimus-eluting stent implantation: incidence and outcome.

    abstract:OBJECTIVE:To examine the long-term outcome of the stent fracture (SF) and the potential predictive factors contributing to in-stent restenosis (ISR) in the fractured stent. BACKGROUND:The SF is thought to be a higher risk of ISR in drug-eluting stent, although SF does not always develop ISR. METHODS:The consecutive 1...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2010.00614.x

    authors: Serikawa T,Kawasaki T,Koga H,Orita Y,Ikeda S,Goto Y,Shintani Y,Kajiwara M,Tanaka H,Fukuyama T,Koga N

    更新日期:2011-04-01 00:00:00

  • Evaluation of Left Main Coronary Artery Using Optical Frequency Domain Imaging and Its Pitfalls.

    abstract:Objectives:We aimed to assess the quality of optical frequency domain imaging (OFDI) of the left main (LM) arterial wall and describe and analyse potential artefacts in this setting. Background:OFDI is increasingly used to assess ambiguous lesions and optimize LM percutaneous coronary intervention. However, its abilit...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1155/2020/4817239

    authors: Roule V,Rebouh I,Lemaitre A,Bignon M,Ardouin P,Sabatier R,Labombarda F,Blanchart K,Beygui F

    更新日期:2020-06-12 00:00:00