Abstract:
OBJECTIVE:In the present study, we investigated the effectiveness and reliability of a new method that reveals whether guidewire advanced distal to the lesion is in the lumen in patients with acute (ATO) or chronic coronary total occlusion (CTO). METHODS:Forty-one patients with symptomatic ATO and 22 patients with CTO who were admitted into our catheterization laboratory between January 2016 and March 2017 were included. In patients in whom antegrade filling could not be demonstrated after passing 0.014″ guidewire beyond the total lesion, a 1.25 × 15 mm balloon was punctured with a needle outside the operative field to visualize the total lesion. This perforated balloon was then used to deliver an opaque substance through this hole to visualize the distal part. RESULTS:The mean age of our 63 patients was 66 ± 12 years. They had diabetes (57%), hypertension (100%), and a history of PCI (85%). The mean procedural time was 27 ± 6.8 min, and the mean volume of contrast material used was 93.9 ± 24 mL. This technique was 100% successful in accurately demonstrating the distal lumen and preventing complications. CONCLUSION:This new method we developed is much simpler and more useful than other methods for visualization of the true lumen because we can re-orient the balloon at the time of opaque injection and use 190 cm guidewire without additional costs. Additionally, one balloon is sufficient for the operation.
journal_name
J Interv Cardioljournal_title
Journal of interventional cardiologyauthors
Balaban Y,Bektaş O,Bayramoğlu A,Gümrükçüoğlu HA,Kayışoğlu AHdoi
10.1111/joic.12444subject
Has Abstractpub_date
2017-12-01 00:00:00pages
544-549issue
6eissn
0896-4327issn
1540-8183journal_volume
30pub_type
杂志文章abstract:OBJECTIVES:We investigated and compared the clinical outcomes between biodegradable polymer biolimus-eluting stents (BES) and durable polymer everolimus-eluting stents (EES) in a single-center prospective registry. BACKGROUND:There is limited data regarding the safety and efficacy of the biodegradable BES compared to ...
journal_title:Journal of interventional cardiology
pub_type: 杂志文章
doi:10.1111/joic.12140
更新日期:2014-08-01 00:00:00
abstract:BACKGROUND:The transradial approach for coronary procedures is associated with a low complication rate, but specific training is considered mandatory. METHODS:Procedural characteristics (contrast dye: CD; fluoroscopy time: FT, patient radiation dose: RD) and local complication rates were prospectively assessed in 784 ...
journal_title:Journal of interventional cardiology
pub_type: 杂志文章
doi:10.1111/j.1540-8183.2010.00603.x
更新日期:2011-02-01 00:00:00
abstract:BACKGROUND:There were insufficient data on the prognosis of stenting for patients with trifurcated unprotected left main lesions (UPLMS). METHODS:From the SPEED (stents for percutaneous treatment of coronary artery disease) registry of all percutaneous coronary interventions (PCI) for all types of UPLMS, data of 44 pa...
journal_title:Journal of interventional cardiology
pub_type: 杂志文章
doi:10.1111/j.1540-8183.2010.00569.x
更新日期:2010-08-01 00:00:00
abstract:OBJECTIVES:To evaluate the effectiveness of the proximal optimization technique (POT) to prevent longitudinal stent elongation. BACKGROUND:The mechanism of stent elongation, which occurs after post-balloon dilation, is still unclear. METHODS:A total of 103 lesions treated with optical coherence tomography guided coro...
journal_title:Journal of interventional cardiology
pub_type: 杂志文章
doi:10.1111/joic.12543
更新日期:2018-10-01 00:00:00
abstract:AIMS:In severe myocardial dysfunction, extracorporeal life support (ECLS) can preserve organ perfusion. Occasionally, the high resulting afterload can lead to refractory pulmonary edema. We report our experience with percutaneous balloon atrioseptostomy used in this circumstance to discharge the left heart and prevent ...
journal_title:Journal of interventional cardiology
pub_type: 杂志文章
doi:10.1111/j.1540-8183.2011.00681.x
更新日期:2012-02-01 00:00:00
abstract:INTRODUCTION:Nonsurgical closure of pathologic vascular communications can be achieved by coil embolization. Different systems used in patients with congenital heart disease (e.g., patent ductus arteriosus) allow controlled release of the devices. However, they are too stiff for coil occlusion of small or tortuous vess...
journal_title:Journal of interventional cardiology
pub_type: 杂志文章
doi:10.1111/j.1540-8183.2001.tb00338.x
更新日期:2001-06-01 00:00:00
abstract:BACKGROUND:Ideally, percutaneous, mechanical closure of defects of the atrial septum should completely resolve shunt. To achieve this goal, more information is needed about the factors associated with device failure. METHODS:Consecutive patients with cryptogenic neurological events who had severe baseline Valsalva shu...
journal_title:Journal of interventional cardiology
pub_type: 杂志文章
doi:10.1111/j.1540-8183.2011.00644.x
更新日期:2011-08-01 00:00:00
abstract:OBJECTIVES:To compare the absorption of 300 mg clopidogrel administered crushed via nasogastric (NG) tube versus whole tablets taken orally in healthy volunteers. BACKGROUND:Earlier antiplatelet therapy has proven benefits in treatment of myocardial infarction and in patients undergoing PCI. Aspirin can be delivered e...
journal_title:Journal of interventional cardiology
pub_type: 杂志文章
doi:10.1111/j.1540-8183.2009.00475.x
更新日期:2009-08-01 00:00:00
abstract::Drug-eluting stents have altered the practice of interventional cardiology by dramatically reducing the risk of angiographic and clinical restenosis following percutaneous coronary intervention. Based on extensive preclinical study and clinical trial data, the polymer-based, slow rate-release paclitaxel-eluting TAXUS ...
journal_title:Journal of interventional cardiology
pub_type: 杂志文章,评审
doi:10.1111/j.1540-8183.2004.04040.x
更新日期:2004-10-01 00:00:00
abstract:BACKGROUND:Rotational atherectomy is used to penetrate resistant coronary lesions from standard balloon dilatation. These lesions may contain heavy calcification or metallic components from previously implanted stents. When the rotablator device is utilized to ablate an undilatable lesion containing metallic stent comp...
journal_title:Journal of interventional cardiology
pub_type: 杂志文章
doi:10.1111/j.1540-8183.2010.00543.x
更新日期:2010-06-01 00:00:00
abstract:OBJECTIVES:This study aimed to examine the outcomes of endovascular recanalization for native superficial femoral artery (SFA) chronic total occlusion (CTO) in patients with critical limb ischemia (CLI) after femoropopliteal bypass failure with limited surgical revascularization options. BACKGROUND:Endovascular recana...
journal_title:Journal of interventional cardiology
pub_type: 杂志文章
doi:10.1111/joic.12470
更新日期:2018-04-01 00:00:00
abstract:Objectives:Our aim was to evaluate the safety and efficacy of biodegradable polymer everolimus-eluting stents (BP-EES) compared with durable polymer everolimus-eluting stents (DP-EES) in midterm. Background:There are few data about midterm clinical outcomes of BP-EES compared with DP-EES. Methods and Results:Between ...
journal_title:Journal of interventional cardiology
pub_type: 杂志文章
doi:10.1155/2020/2869303
更新日期:2020-04-20 00:00:00
abstract::Catheter-based vascular interventions have been in development worldwide for several decades, leading to remarkable progress in device technology. Mechanical interventional devices, such as angioplasty balloons, atherectomy devices, and stents, were invented and have contributed greatly to the treatment of atheroscler...
journal_title:Journal of interventional cardiology
pub_type: 杂志文章,评审
doi:10.1111/j.1540-8183.2002.tb01070.x
更新日期:2002-10-01 00:00:00
abstract::Eighty-three consecutive patients with 85 coronary total occlusions undergoing coronary angioplasty were retrospectively studied. Patients were divided into two groups according to the occlusion age that was < 30 days (subacute total occlusion [STO]: 25 patients; range 1-30 days) or > 30 days (chronic total occlusion ...
journal_title:Journal of interventional cardiology
pub_type: 杂志文章
doi:10.1111/j.1540-8183.2002.tb01052.x
更新日期:2002-06-01 00:00:00
abstract:OBJECTIVE:The purpose of this study was to identify potential predictors, including clinical, procedural, angiographic, and intravascular ultrasound (IVUS) parameters, for recurrent in-stent restenosis (ISR) following beta-radiation 90Strontium/Yttrium (90Sr/Y) in a large multicenter trial. BACKGROUND:Although adjunct...
journal_title:Journal of interventional cardiology
pub_type: 杂志文章,多中心研究
doi:10.1111/j.1540-8183.2006.00188.x
更新日期:2006-10-01 00:00:00
abstract::Endovascular abdominal aortic aneurysm repair using a modular bifurcated stent-graft requires the initial placement of the main component in the infrarenal aorta, followed by insertion of additional iliac stent-graft(s) to exclude aneurysm and to securely affix the device. Placement of the contralateral iliac componen...
journal_title:Journal of interventional cardiology
pub_type: 杂志文章,评审
doi:10.1034/j.1600-0854.2003.8046.x
更新日期:2003-06-01 00:00:00
abstract:INTRODUCTION:Current guidelines recommend coronary artery bypass grafting (CABG) for patients with multivessel coronary disease and left ventricular (LV) dysfunction. However, some patients undergo percutaneous coronary intervention (PCI) or solely medical therapy (MT) in actual practice. The comparison of long-term ou...
journal_title:Journal of interventional cardiology
pub_type: 杂志文章
doi:10.1111/joic.12497
更新日期:2018-06-01 00:00:00
abstract:BACKGROUND:Drug-eluting stents showed a better angiographic and clinical outcome in comparison with bare metal stent in chronic total occlusions (CTOs) percutaneous revascularization, however, great concerns still remain regarding the rate of restenosis and reocclusion in comparison with nonocclusive lesions. AIM:To e...
journal_title:Journal of interventional cardiology
pub_type: 杂志文章
doi:10.1111/j.1540-8183.2011.00648.x
更新日期:2011-10-01 00:00:00
abstract::Paravalvular leaks are a recognized complication of valve replacement surgery. We report a 47-year-old man with left atrial isomerism, interrupted left sided inferior caval vein with unilateral left sided superior caval vein, a common atrium, and anomalous pulmonary venous connection to the coronary sinus, who had rec...
journal_title:Journal of interventional cardiology
pub_type: 杂志文章
doi:10.1111/j.1540-8183.2007.00290.x
更新日期:2007-12-01 00:00:00
abstract:PURPOSE:In patients on oral anticoagulation (OAC) undergoing coronary stenting (PCI-S), procedural management and in-hospital outcome have never been specifically and prospectively investigated. Also, the contribution of early bleeding to the relevant hemorrhagic rate reported at follow-up with triple therapy of OAC, a...
journal_title:Journal of interventional cardiology
pub_type: 临床试验,杂志文章,多中心研究
doi:10.1111/j.1540-8183.2009.00468.x
更新日期:2009-08-01 00:00:00
abstract:BACKGROUND:Differences in stent platform, polymer coatings, and antirestenotic drugs among the current in use second-generation drug-eluting stents (G2-DESs) may induce significant variations in neointimal response and vascular healing, which may impact the prevalence of neoatherosclerosis (NA) and morphological appear...
journal_title:Journal of interventional cardiology
pub_type: 杂志文章
doi:10.1111/joic.12375
更新日期:2017-06-01 00:00:00
abstract::The use of radiofrequency energy for the treatment of supraventricular tachycardia in pediatric patients has gained widespread acceptance, especially for tachyarrhythmias associated with palpitations, dizziness, presyncope or syncope, cardiomyopathy, and cardiac arrest. Ablation of the substrate supporting atrioventri...
journal_title:Journal of interventional cardiology
pub_type: 杂志文章,评审
doi:10.1111/j.1540-8183.1995.tb00583.x
更新日期:1995-10-01 00:00:00
abstract::Direct stenting could potentially lead to a reduction in dissections, time, and restenosis at 6-month follow-up. Using the premounted Palmaz-Schatz Crown stent elective stenting was performed without predilatation in 61 consecutive patients who were compared with a control group of provisional stenting. All patients u...
journal_title:Journal of interventional cardiology
pub_type: 杂志文章
doi:10.1111/j.1540-8183.2002.tb01101.x
更新日期:2002-08-01 00:00:00
abstract::The purpose of this study is to evaluate long-term clinical and angiographic follow-up results after placement of the Palmaz-Schatz stent and angiographic follow-up results of repeat interventions for stent restenosis. From June 1990 to September 1993, the Palmaz-Schatz stent was placed in 411 patients, 427 lesions. ...
journal_title:Journal of interventional cardiology
pub_type: 杂志文章
doi:10.1111/j.1540-8183.1994.tb00896.x
更新日期:1994-04-01 00:00:00
abstract:AIMS:To evaluate the correlation between iFR and FFR in real-world clinical practice. METHODS AND RESULTS:Retrospective, single-centre study of 229 consecutive pressure-wire studies (np = 158). Real-time iFR and FFR measurements were performed for angiographically borderline stenoses. Functionally significant stenose...
journal_title:Journal of interventional cardiology
pub_type: 杂志文章
doi:10.1111/joic.12422
更新日期:2017-12-01 00:00:00
abstract:BACKGROUND:The economic impact of bleeding in the setting of nonemergent percutaneous coronary intervention (PCI) is poorly understood and complicated by the variety of bleeding definitions currently employed. This retrospective analysis examines and contrasts the in-hospital cost of bleeding associated with this proce...
journal_title:Journal of interventional cardiology
pub_type: 杂志文章
doi:10.1111/j.1540-8183.2009.00431.x
更新日期:2009-06-01 00:00:00
abstract:BACKGROUND:There has been growing interest in transcatheter closure of interatrial septal defects (IASDs) for a variety of indications, but reports are limited in patients with hypoxia from right-to-left shunting. METHODS:Between August 2000 and October 2004, 181 patients were referred to our institution for elective ...
journal_title:Journal of interventional cardiology
pub_type: 杂志文章
doi:10.1111/j.1540-8183.2005.00043.x
更新日期:2005-08-01 00:00:00
abstract::This case report documents the presentation of a disabling ionizing radiation (IR)-related illness (multiple basal cell carcinoma [BCC] syndrome) in a 50-year-old interventional cardiologist. This case emphasizes the need for interventionalists to: (1) understand the occupational hazards of IR; (2) recognize the failu...
journal_title:Journal of interventional cardiology
pub_type: 杂志文章
doi:10.1111/j.1540-8183.2010.00610.x
更新日期:2011-02-01 00:00:00
abstract:OBJECTIVE:To examine the long-term outcome of the stent fracture (SF) and the potential predictive factors contributing to in-stent restenosis (ISR) in the fractured stent. BACKGROUND:The SF is thought to be a higher risk of ISR in drug-eluting stent, although SF does not always develop ISR. METHODS:The consecutive 1...
journal_title:Journal of interventional cardiology
pub_type: 杂志文章
doi:10.1111/j.1540-8183.2010.00614.x
更新日期:2011-04-01 00:00:00
abstract:Objectives:We aimed to assess the quality of optical frequency domain imaging (OFDI) of the left main (LM) arterial wall and describe and analyse potential artefacts in this setting. Background:OFDI is increasingly used to assess ambiguous lesions and optimize LM percutaneous coronary intervention. However, its abilit...
journal_title:Journal of interventional cardiology
pub_type: 杂志文章
doi:10.1155/2020/4817239
更新日期:2020-06-12 00:00:00