Topical capsaicin for pain management: therapeutic potential and mechanisms of action of the new high-concentration capsaicin 8% patch.

Abstract:

:Topical capsaicin formulations are used for pain management. Safety and modest efficacy of low-concentration capsaicin formulations, which require repeated daily self-administration, are supported by meta-analyses of numerous studies. A high-concentration capsaicin 8% patch (Qutenza™) was recently approved in the EU and USA. A single 60-min application in patients with neuropathic pain produced effective pain relief for up to 12 weeks. Advantages of the high-concentration capsaicin patch include longer duration of effect, patient compliance, and low risk for systemic effects or drug-drug interactions. The mechanism of action of topical capsaicin has been ascribed to depletion of substance P. However, experimental and clinical studies show that depletion of substance P from nociceptors is only a correlate of capsaicin treatment and has little, if any, causative role in pain relief. Rather, topical capsaicin acts in the skin to attenuate cutaneous hypersensitivity and reduce pain by a process best described as 'defunctionalization' of nociceptor fibres. Defunctionalization is due to a number of effects that include temporary loss of membrane potential, inability to transport neurotrophic factors leading to altered phenotype, and reversible retraction of epidermal and dermal nerve fibre terminals. Peripheral neuropathic hypersensitivity is mediated by diverse mechanisms, including altered expression of the capsaicin receptor TRPV1 or other key ion channels in affected or intact adjacent peripheral nociceptive nerve fibres, aberrant re-innervation, and collateral sprouting, all of which are defunctionalized by topical capsaicin. Evidence suggests that the utility of topical capsaicin may extend beyond painful peripheral neuropathies.

journal_name

Br J Anaesth

authors

Anand P,Bley K

doi

10.1093/bja/aer260

subject

Has Abstract

pub_date

2011-10-01 00:00:00

pages

490-502

issue

4

eissn

0007-0912

issn

1471-6771

pii

S0007-0912(17)33029-5

journal_volume

107

pub_type

杂志文章,评审
  • The use of propanidid and lignocaine to reduce suxamethonium fasciculations.

    abstract::A technique of induction of anaesthesia using propanidid, lignocaine and suxamethonium is described, and the muscle fasciculations that follow it are shown to be significantly less than those accompanying induction with methohexitone and suxamethonium. ...

    journal_title:British journal of anaesthesia

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1093/bja/47.6.723

    authors: Fry EN

    更新日期:1975-06-01 00:00:00

  • Performing perioperative optimization of the high-risk surgical patient.

    abstract::Perioperative risk of death after general surgery is quoted as overall less than 1%. However, each individual's risk varies widely according to many identified factors with some having a significantly increased risk of a worse outcome. The observation that manipulating and targeting certain physiological parameters in...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章,评审

    doi:10.1093/bja/ael102

    authors: Tote SP,Grounds RM

    更新日期:2006-07-01 00:00:00

  • Pharmacokinetic and clinical study of ropivacaine and bupivacaine in women receiving extradural analgesia in labour.

    abstract::We have compared, in a randomized, double-blind study, the pharmacokinetics of ropivacaine and bupivacaine during labour. Total and free plasma concentrations of ropivacaine and bupivacaine were measured after the first of two extradural doses. The main dose was 20 mg (test dose) and 30 mg, with a top-up dose of 25 mg...

    journal_title:British journal of anaesthesia

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1093/bja/79.5.558

    authors: McCrae AF,Westerling P,McClure JH

    更新日期:1997-11-01 00:00:00

  • Prediction of outliers in pain, analgesia requirement, and recovery of function after childbirth: a prospective observational cohort study.

    abstract:BACKGROUND:Prediction models to identify parturients who experience protracted pain, prolonged opioid use, and delayed self-assessed functional recovery are currently inadequate. METHODS:For this study, 213 nulliparous women who planned vaginal delivery were enrolled and assessed daily until they completed three outco...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章

    doi:10.1016/j.bja.2018.04.033

    authors: Komatsu R,Carvalho B,Flood P

    更新日期:2018-08-01 00:00:00

  • Pulmonary embolism during surgery for a Wilms' tumour (nephroblastoma). Case report.

    abstract::During resection of a Wilms' tumour in a 10-year-old girl, sudden bradycardia, hypotension and cyanosis developed, leading to cardiac arrest. It was thought that part of the tumour had caused a pulmonary embolus. After prompt resuscitation, cardiopulmonary bypass surgery was started within 20 min. At operation the lef...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章

    doi:10.1093/bja/53.8.903

    authors: Akyön MG,Arslan G

    更新日期:1981-08-01 00:00:00

  • Regional anaesthesia for carotid endarterectomy: an audit over 10 years.

    abstract:BACKGROUND:The aim of this retrospective study was to compare the failure rates and the frequency of anaesthesia-related complications of two different methods of regional anaesthesia used for carotid endarterectomy--cervical epidural (CE) anaesthesia and cervical plexus block (CPB). METHODS:The study included 1828 ca...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章,多中心研究

    doi:10.1093/bja/aem171

    authors: Hakl M,Michalek P,Sevcík P,Pavlíková J,Stern M

    更新日期:2007-09-01 00:00:00

  • Rationalization of the selection of tracheal tubes.

    abstract::The problems of selection of tracheal tubes, and the need for a rationale, are outlined. Tracheal tubes of 7.5 mm and 8.5 mm i.d. are recommended for female and male patients, respectively. Tracheal size was determined using high pressure-low volume cuffs as measuring devices. The average diameter of the cuff at seal ...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章

    doi:10.1093/bja/58.1.111

    authors: Chandler M,Crawley BE

    更新日期:1986-01-01 00:00:00

  • Comparison between pressures measured from the proximal external jugular vein and a central vein.

    abstract::Mean venous pressures were measured in 20 patients in whom a catheter, inserted via the external jugular vein, failed to pass centrally. The catheter used had a rounded end and two side holes. Pressures were measured with the patient's head in three different positions. The pressures were compared with the central ven...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章

    doi:10.1093/bja/58.12.1384

    authors: Shah MV,Swai EA,Latto IP

    更新日期:1986-12-01 00:00:00

  • Superficial or deep cervical plexus block for carotid endarterectomy: a systematic review of complications.

    abstract::Carotid endarterectomy is commonly conducted under regional (deep, superficial, intermediate, or combined) cervical plexus block, but it is not known if complication rates differ. We conducted a systematic review of published papers to assess the complication rate associated with superficial (or intermediate) and deep...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章,meta分析,评审

    doi:10.1093/bja/aem160

    authors: Pandit JJ,Satya-Krishna R,Gration P

    更新日期:2007-08-01 00:00:00

  • A comparison of the respiratory effects of meptazinol, pentazocine and morphine.

    abstract::The respiratory effects of a new strong analgesic, meptazinol, were compared with a placebo and with equianalgesic doses of morphine and pentazocine in a double-blind crossover trial in seven healthy volunteers. No significant change in the ventilatory response to rebreathing carbon dioxide was observed after meptazin...

    journal_title:British journal of anaesthesia

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1093/bja/51.6.497

    authors: Jordan C,Lehane JR,Robson PJ,Jones JG

    更新日期:1979-06-01 00:00:00

  • A consensus checklist to help clinicians interpret clinical trial results analysed by Bayesian methods.

    abstract:INTRODUCTION:In the context of an increasing number of publications of trial data analysed by Bayesian methods, clinicians need support to better understand Bayesian statistical methods. The existing checklists are intended for people who already know these methods. We aimed to establish and validate a checklist that c...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章

    doi:10.1016/j.bja.2020.04.093

    authors: Ferreira D,Barthoulot M,Pottecher J,Torp KD,Diemunsch P,Meyer N

    更新日期:2020-08-01 00:00:00

  • Fentanyl and bupivacaine mixtures for extradural blockade.

    abstract::In a prospective double-blind study, single dose lumbar extradural blockade was instituted in 80 healthy male patients undergoing lower abdominal surgery. Patients were assigned randomly to one of four groups. Each group received treatment with 0.5% bupivacaine 20 ml containing adrenaline 1:200 000. To this solution w...

    journal_title:British journal of anaesthesia

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1093/bja/57.3.275

    authors: Rucci FS,Cardamone M,Migliori P

    更新日期:1985-03-01 00:00:00

  • Analgesic effect in humans of subanaesthetic isoflurane concentrations evaluated by experimentally induced pain.

    abstract::The analgesic effect of subanaesthetic concentrations of ether, trichloroethylene, methoxyflurane and halothane has been investigated previously using either clinical assessment or pain threshold measurements, but with conflicting results. The purpose of the present study was to evaluate the analgesic effect of isoflu...

    journal_title:British journal of anaesthesia

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1093/bja/75.1.55

    authors: Petersen-Felix S,Arendt-Nielsen L,Bak P,Roth D,Fischer M,Bjerring P,Zbinden AM

    更新日期:1995-07-01 00:00:00

  • Increase in tracheal pressure during jet ventilation.

    abstract::Gas injection systems used in several techniques of ventilation cause increases in airway pressure and physiological changes which are frequently overlooked. The momentum flux theory describes such phenomena most appropriately. We have defined and measured the characteristics of such increases in airway pressure, usin...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章

    doi:10.1093/bja/63.7.71

    authors: Isabey D,Boussignac G,Harf A

    更新日期:1989-01-01 00:00:00

  • Ro 15-1788 antagonizes the effects of diazepam in man without affecting its bioavailability.

    abstract::In a double-blind, placebo-controlled three-way cross over study, the efficacy of Ro 15-1788 200 mg, a new benzodiazepine antagonist, in blocking the amnesic, cognitive, psychomotor and subjective effects of diazepam 20 mg, was investigated in a group of six healthy male volunteers. The amnesic effects of diazepam wer...

    journal_title:British journal of anaesthesia

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1093/bja/55.4.349

    authors: O'Boyle C,Lambe R,Darragh A,Taffe W,Brick I,Kenny M

    更新日期:1983-04-01 00:00:00

  • Conservative management of extradural abscess complicating spinal-extradural anaesthesia for caesarean section.

    abstract::We report a case of lumbar extradural abscess that presented 9 days after an elective Caesarean section performed under combined spinal-extradural anaesthesia. This was successfully treated conservatively with full recovery. The clinical course included development, and then resolution, of mild paraparesis. Conservati...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章

    doi:10.1093/bja/78.5.591

    authors: Dysart RH,Balakrishnan V

    更新日期:1997-05-01 00:00:00

  • Efficacy and respiratory effects of low-dose spinal morphine for postoperative analgesia following knee arthroplasty.

    abstract::A randomized, double-blind study of 38 patients undergoing total knee replacement was undertaken to compare the efficacy and respiratory effects of low-dose spinal morphine and patient-controlled i.v. morphine against patient-controlled i.v. morphine alone. Patients received either morphine 0.3 mg or saline 0.3 ml wit...

    journal_title:British journal of anaesthesia

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1093/bja/85.2.233

    authors: Cole PJ,Craske DA,Wheatley RG

    更新日期:2000-08-01 00:00:00

  • Haemodynamic effects of diaspirin crosslinked haemoglobin (DCLHb) given before abdominal aortic aneurysm surgery.

    abstract::We studied 34 patients undergoing elective repair of an abdominal aortic aneurysm under combined general anaesthesia and epidural block to evaluate the acute effects of diaspirin crosslinked haemoglobin (DCLHb) 50, 100 and 200 mg kg-1 i.v. Haemodynamic variables were measured continuously using pulmonary and radial ar...

    journal_title:British journal of anaesthesia

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1093/bja/83.5.702

    authors: Garrioch MA,McClure JH,Wildsmith JA

    更新日期:1999-11-01 00:00:00

  • Effects of phenylephrine on the sublingual microcirculation during cardiopulmonary bypass.

    abstract:BACKGROUND:The objective of the present study was to investigate sublingual microvascular blood flow and microcirculatory haemoglobin oxygen saturation (Smc(O(2))) during cardiopulmonary bypass (CPB) using constant systemic blood flow but different perfusion pressures achieved by phenylephrine administration. METHODS:...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章

    doi:10.1093/bja/aep018

    authors: Maier S,Hasibeder WR,Hengl C,Pajk W,Schwarz B,Margreiter J,Ulmer H,Engl J,Knotzer H

    更新日期:2009-04-01 00:00:00

  • Rapidity and accuracy of tracheal intubation in a mannequin: comparison of the fibreoptic with the Bullard laryngoscope.

    abstract::Successful tracheal intubation with the flexible fibreoptic bronchoscope requires a certain amount of skill which is acquired by practice. It has been suggested that the new Bullard laryngoscope may be mastered more easily. To determine if learning was superior with a flexible fibreoptic or the Bullard device, the eas...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章

    doi:10.1093/bja/65.2.268

    authors: Dyson A,Harris J,Bhatia K

    更新日期:1990-08-01 00:00:00

  • Improved performance on cardiopulmonary exercise testing following DDDR pacemaker adjustment: a case report.

    abstract::We report a case of improved cardiopulmonary exercise (CPX) test outcomes measured 48 h after initial CPX testing and immediately after alterations were made to the settings of a dual chamber, dual sensing pacemaker with exercise detection. The changes allowed successful abdominal surgery to be completed. ...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章

    doi:10.1093/bja/aet587

    authors: Bolsin S,Colson M,Ridley D,Ward C

    更新日期:2014-06-01 00:00:00

  • Effect of adrenaline on venous plasma concentrations of bupivacaine after interpleural administration.

    abstract::Bupivacaine 2.5 mg kg-1 (0.5 ml kg-1 of 0.5% solution), with or without adrenaline 5 micrograms ml-1, was administered by interpleural injection to 12 patients after elective cholecystectomy. Noncompartmental analysis indicated that the addition of adrenaline had no effect on total body clearance, apparent volume of d...

    journal_title:British journal of anaesthesia

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1093/bja/64.6.662

    authors: Gin T,Chan K,Kan AF,Gregory MA,Wong YC,Oh TE

    更新日期:1990-06-01 00:00:00

  • A study of intracuff pressure measurements, trends and behaviour in patients during prolonged periods of tracheal intubation.

    abstract::Intracuff pressure (c.p.) was measured continuously in 12 patients during prolonged periods of tracheal intubation. High residual volume--low pressure (floppy) and low residual volume--high pressure (conventional) cuffs were studied. The mean baseline c.p. at minimal occluding pressure was significantly smaller in flo...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章

    doi:10.1093/bja/53.1.97

    authors: Jacobson L,Greenbaum R

    更新日期:1981-01-01 00:00:00

  • A preliminary investigation of the renal and hepatic excretion of gallamine triethiodide in man.

    abstract::The fate of gallamine triethiodide has been investigated in patients undergoing cholecystectomy with choledochostomy (group I), pelvic operations (group II) and orthopaedic operations (group III). Following a single i.v. injection of gallamine 2.5 mg kg(-1) the disappearance of the drug from the serum occurred in thre...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章

    doi:10.1093/bja/50.4.345

    authors: Agoston S,Vermeer GA,Kersten UW,Scaf AH

    更新日期:1978-04-01 00:00:00

  • Extradural analgesia with clonidine and fentanyl compared with 0.25% bupivacaine in the first stage of labour.

    abstract::Conventional extradural analgesia during labour with 0.25-0.375% bupivacaine may induce motor weakness and subjective sensory deficit, reducing maternal satisfaction. Even in a regimen for ambulatory extradural analgesia (0.1% bupivacaine-fentanyl 2 micrograms ml-1), a potential for proprioreception impairment exists,...

    journal_title:British journal of anaesthesia

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1093/bja/76.2.319

    authors: Buggy DJ,MacDowell C

    更新日期:1996-02-01 00:00:00

  • Does the addition of clonidine affect duration of analgesia of bupivacaine wound infiltration in inguinal hernia surgery?

    abstract::We conducted a prospective, randomized, double-blind study to compare analgesia obtained by wound infiltration using 29 ml of 0.25% bupivacaine alone, or with the addition of clonidine hydrochloride 150 micrograms. A third group received bupivacaine wound infiltration with clonidine 150 micrograms i.m. to control for ...

    journal_title:British journal of anaesthesia

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1093/bja/79.4.446

    authors: Elliott S,Eckersall S,Fligelstone L,Jothilingam S

    更新日期:1997-10-01 00:00:00

  • Ultrasound-guided anterior approach to the axillary and intercostobrachial nerves in the axillary fossa: an anatomical investigation.

    abstract:BACKGROUND:The posterolateral and medial aspect of the arm is supplied by the axillary (AXN) and intercostobrachial nerves (ICBN), which are not anaesthetised by an axillary brachial plexus block (ABPB). Blockade of the AXN and the ICBN has been reported in the quadrangular space (QS) posteriorly or by serratus plane b...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章

    doi:10.1016/j.bja.2018.06.006

    authors: Feigl G,Aichner E,Mattersberger C,Zahn PK,Avila Gonzalez C,Litz R

    更新日期:2018-10-01 00:00:00

  • Lumbar extradural injection pressures in pregnant women. An investigation of relationships between rate of infection, injection pressures and extent of analgesia.

    abstract::Before the induction of labour in 34 pregnant women 1.5% lignocaine 10 ml was injected into the lumbar extradural space at constant rates between 0.143 and 0.333 ml s-1. Injection pressures and residual pressures were recorded and the extent of analgesia to pinprick was assessed. No significant correlation was found b...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章

    doi:10.1093/bja/52.1.55

    authors: Husemeyer RP,White DC

    更新日期:1980-01-01 00:00:00

  • Diazepam: routes of administration and rate of absorption. A study of women with pre-eclampsia.

    abstract::Plasma diazepam concentrations were determined following oral, i.m. and i.v. administration to a group of pregnant women with pre-eclampsia and a group of normal pregnant women. Diazepam concentrations were greater following oral as compared with i.m. administration in the control group, who received a single 5-mg dos...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章

    doi:10.1093/bja/48.11.1091

    authors: Sturdee DW

    更新日期:1976-11-01 00:00:00

  • Bupivacaine concentrations in the lumbar cerebrospinal fluid of patients during spinal anaesthesia.

    abstract:BACKGROUND:Data on bupivacaine concentrations in the cerebral spinal fluid (CSF) during spinal anaesthesia are scarce. The purpose of this study was to determine the concentration of bupivacaine in the lumbar CSF of patients with an adequate level of spinal anaesthesia after injection of plain bupivacaine 0.5%. METHOD...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章

    doi:10.1093/bja/aep049

    authors: Ruppen W,Steiner LA,Drewe J,Hauenstein L,Brugger S,Seeberger MD

    更新日期:2009-06-01 00:00:00