Intacs insertion with the femtosecond laser for the management of keratoconus: one-year results.

Abstract:

PURPOSE:To assess the outcomes of intrastromal ring segment (Intacs, Addition Technology) implantation for keratoconus using the femtosecond laser. SETTING:Kudret Eye Hospital, Ankara, Turkey. METHODS:In a retrospective noncomparative case series, 118 eyes of 69 patients with keratoconus who had Intacs segments implanted with the femtosecond laser were evaluated. Preoperative and postoperative evaluations included slitlamp examination, uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), and mean keratometry values measured with the Pentacam Scheimpflug camera (Oculus Opticgerate GmbH). All parameters were assessed preoperatively and 1 year after Intacs implantation. RESULTS:Intacs were successfully implanted in all eyes. At the end of the first postoperative year, 81.3% of eyes had improved UCVA and 73.7% had improved BCVA. The mean keratometry decreased from 51.56 diopters (D) to 47.66 D, and the mean refractive spherical equivalent decreased from -7.57 D to -3.72 D. CONCLUSIONS:Intacs implantation with the femtosecond laser was safe and effective for the treatment of keratoconus. All parameters had improved by the 1-year follow-up.

authors

Ertan A,Kamburoğlu G,Bahadir M

doi

10.1016/j.jcrs.2006.08.032

subject

Has Abstract

pub_date

2006-12-01 00:00:00

pages

2039-42

issue

12

eissn

0886-3350

issn

1873-4502

pii

S0886-3350(06)01131-X

journal_volume

32

pub_type

杂志文章
  • Effect of residual ocular spherical aberration on objective and subjective quality of vision in pseudophakic eyes.

    abstract:PURPOSE:To determine the level of residual spherical aberration that gives the best objective and subjective quality of image after cataract surgery with intraocular lens (IOL) implantation. SETTING:Department of Ophthalmology, CHU Bretonneau, Tours, France. DESIGN:Cohort study. METHODS:Six months after microincisio...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2010.12.056

    authors: Nochez Y,Majzoub S,Pisella PJ

    更新日期:2011-06-01 00:00:00

  • Transition to nonpenetrating trabecular surgery: sclerotrabeculectomy.

    abstract::A transition from trabeculectomy to nonpenetrating trabecular surgery (NPTS) is proposed under the name of sclerotrabeculectomy. The technique, which is aimed at facilitating the transition to NPTS, is a modification of both penetrating and nonpenetrating techniques. Sclerotrabeculectomy uses a more superficial sclero...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(02)01363-9

    authors: Sourdille P,Santiago PY,Bresson-Dumont H

    更新日期:2002-12-01 00:00:00

  • Pupillary capture after combined management of cataract and vitreoretinal pathology.

    abstract:PURPOSE:To report the incidence, pathogenesis, and management of pupillary capture after combined phacoemulsification with intraocular lens (IOL) implantation and vitreoretinal surgery. SETTING:Oxford Eye Hospital, The Radcliffe Infirmary, Oxford, United Kingdom. METHODS:This retrospective case review comprised 12 pa...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(02)01212-9

    authors: Rahman R,Rosen PH

    更新日期:2002-09-01 00:00:00

  • United Kingdom national cataract training survey.

    abstract:UNLABELLED:A nationwide postal survey of all consultant ophthalmologists in the United Kingdom was conducted to determine attitudes and techniques of cataract surgery trainers, identify trainer-related factors that determine surgical opportunity, and ascertain whether trainers had received adequate training in how to t...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2011.12.024

    authors: Alexander P,Matheson D,Baxter J,Tint NL

    更新日期:2012-03-01 00:00:00

  • Effect of a capsular tension ring on the shape of the capsular bag and opening and the intraocular lens.

    abstract:PURPOSE:To evaluate the effect of a capsular tension ring (CTR) on the shape of the capsular bag, the extent of the capsular opening, and the shape of intraocular lenses (IOLs). SETTING:Department of Ophthalmology, College of Medicine, The Catholic University of Korea, Seoul, Korea. METHODS:The corneal button was rem...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(00)00610-6

    authors: Lee DH,Lee HY,Lee KH,Chung KH,Joo CK

    更新日期:2001-03-01 00:00:00

  • Clinical outcomes after bilateral implantation of an apodized +3.0 D toric diffractive multifocal intraocular lens.

    abstract:PURPOSE:To assess visual outcomes after bilateral implantation of an apodized +3.0 diopter (D) addition power toric diffractive multifocal intraocular lens (IOL). SETTING:Five study sites in Europe and South America. DESIGN:Cohort study. METHODS:Patients had bilateral implantation of the AcrySof(®) IQ ReSTOR(®)+3.0 ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1016/j.jcrs.2013.06.026

    authors: Alfonso JF,Knorz M,Fernandez-Vega L,Rincón JL,Suarez E,Titke C,Kohnen T

    更新日期:2014-01-01 00:00:00

  • Biomechanical aspects of the anterior capsulotomy.

    abstract::We used the finite element method to evaluate different capsulotomy techniques. Nucleus expression was simulated in a computer model to visualize stress distribution in the anterior capsule. The finite element model demonstrated that the capsulorhexis edge is strong because of low and uniform stress distribution in th...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(13)80176-9

    authors: Krag S,Thim K,Corydon L,Kyster B

    更新日期:1994-07-01 00:00:00

  • Updated cataract surgery complexity stratification score for trainee ophthalmic surgeons.

    abstract:PURPOSE:To devise a comprehensive cataract surgery complexity score system for the selection of appropriate cases for trainees using evidence-based, validated risk factors for posterior capsule rupture, patient-specific factors, and complexity stratification recommendations to minimize complications, optimize outcomes,...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2018.04.036

    authors: Nderitu P,Ursell P

    更新日期:2018-06-01 00:00:00

  • Phakonit: phacoemulsification through a 0.9 mm corneal incision.

    abstract::Advances in technique and equipment have led to a significant increase in the popularity of phacoemulsification and have increased its safety and efficiency. We describe a technique, phakonit, in which the lens is emulsified through a 0.9 mm clear corneal temporal incision. A cortical wash with bimanual irrigation/asp...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(01)00922-1

    authors: Agarwal A,Agarwal A,Agarwal S,Narang P,Narang S

    更新日期:2001-10-01 00:00:00

  • Capsulorhexis rescue after peripheral radial tear-out: quick-pull technique.

    abstract:UNLABELLED:We describe a technique to rescue the continuous curvilinear capsulorhexis (CCC) in cases in which complete radial tears make it impossible to use normal traction forceps. A circumferential path and rapid movement are applied in the plane of the anterior capsule in the direction of the center pupil. This tec...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2012.02.019

    authors: Coelho RP,Paula JS,Rosatelli Neto JM,Messias AM

    更新日期:2012-05-01 00:00:00

  • Comparison of mechanical and femtosecond laser tunnel creation for intrastromal corneal ring segment implantation in keratoconus: prospective randomized clinical trial.

    abstract:PURPOSE:To compare the outcomes of mechanical and femtosecond laser-assisted tunnel creation for intrastromal corneal ring segment (ICRS) implantation in eyes with keratoconus. SETTING:Kartal Training and Research Hospital, Istanbul, Turkey. METHODS:In this prospective study, consecutive eyes with keratoconus were ra...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.jcrs.2010.04.028

    authors: Kubaloglu A,Sari ES,Cinar Y,Cingu K,Koytak A,Coşkun E,Ozertürk Y

    更新日期:2010-09-01 00:00:00

  • Exchange of a posterior chamber phakic intraocular lens in a highly myopic eye.

    abstract::A 38-year-old woman had posterior chamber phakic intraocular lens (IOL) implantation as a secondary refractive procedure to correct residual refraction (20/50 with -16.50 -1.50 x 80) in May 1998, 3 years after intrastromal corneal ring segment surgery for high myopia (-30.00 diopters). Ultrasound biomicroscopy reveale...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(00)00410-7

    authors: Trindade F,Pereira F

    更新日期:2000-05-01 00:00:00

  • Draping technique to isolate lashes and achieve maximum exposure.

    abstract::A surgical draping technique is presented that decreases surgical time, maximizes surgical site exposure, and decreases the risk of infection. It was also designed to enhance patent comfort. ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(98)80094-1

    authors: Slade SG,Brint SF

    更新日期:1998-08-01 00:00:00

  • Light transmittance of 1-piece hydrophobic acrylic intraocular lenses with surface light scattering removed from cadaver eyes.

    abstract:PURPOSE:To assess the potential effect of surface light scattering on light transmittance of 1-piece hydrophobic acrylic intraocular lenses (IOLs) with or without a blue-light filter. SETTING:John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. DESIGN:Experimental study. METHODS:Intraocular lense...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2013.05.050

    authors: Werner L,Morris C,Liu E,Stallings S,Floyd A,Ollerton A,Leishman L,Bodnar Z

    更新日期:2014-01-01 00:00:00

  • High-vacuum clothesline technique for elevation and repositioning of posteriorly dislocated intraocular lens.

    abstract::We describe a technique to simplify the retrieval process of an intraocular lens (IOL) that has fallen into the posterior segment of the eye. A high-vacuum level setting is used to achieve fixation of the IOL to the vitrectomy tip, permitting the IOL to be elevated into the anterior segment. The clothesline technique ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2017.12.018

    authors: Mackool RJ Sr,Mackool RJ Jr,Solinsky BM

    更新日期:2018-03-01 00:00:00

  • Effect of incision length, location, and shape on local corneoscleral deformation during cataract surgery.

    abstract::The effect of incision length, location, and shape on the structural integrity of the globe was examined using finite element analysis by comparing the radial deformation of the corneoscleral tissue adjacent to the incision. The results show that incision length had the greatest adverse effect, 12 mm incisions causing...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(13)80879-6

    authors: Armeniades CD,Boriek A,Knolle GE Jr

    更新日期:1990-01-01 00:00:00

  • Reversibility and exchangeability of intrastromal corneal ring segments.

    abstract:PURPOSE:To evaluate the effect of removal and/or exchange of intrastromal corneal ring segments (ICRS, Intacs); specifically the risk factors, degree of reversibility, and visual outcomes. SETTING:Gimbel Eye Centres, Calgary, Edmonton, and Vancouver, Canada. METHODS:Prospective cohort data were collected on 71 eyes t...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(01)01172-5

    authors: Chan SM,Khan HN

    更新日期:2002-04-01 00:00:00

  • Delayed intraocular lens dislocation after neodymium:YAG capsulotomy.

    abstract::A poly(methyl methacrylate)(PMMA) intraocular lens (IOL) dislocated into the vitreous cavity in 2 patients after a neodymium:YAG (Nd:YAG) laser posterior capsulotomy. In Case 1, the capsulotomy was performed 19 months after extracapsular cataract extraction (ECCE) and sulcus fixation of an IOL. Six months later the IO...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(98)80182-x

    authors: Framme C,Hoerauf H,Roider J,Laqua H

    更新日期:1998-11-01 00:00:00

  • Assessment of a new averaging algorithm to increase the sensitivity of axial eye length measurement with optical biometry in eyes with dense cataract.

    abstract:PURPOSE:To assess the capability of new software to decrease the proportion of eyes that have insufficient signal-to-noise ratio (SNR) in optical biometry. SETTING:Moorfields Eye Hospital NHS Foundation Trust, London, United Kingdom. DESIGN:Evaluation of diagnostic test or technology. METHODS:In a prospective study,...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2010.07.023

    authors: Hirnschall N,Murphy S,Pimenides D,Maurino V,Findl O

    更新日期:2011-01-01 00:00:00

  • Surgical options for retreatment after small-incision lenticule extraction: Advantages and disadvantages.

    abstract::Since the inception of small-incision lenticule extraction (SMILE), many surgeons have speculated the lack of an adequate and standard retreatment procedure will impede its popularity. However, more than 1 million patients worldwide have had this surgery, with visual outcomes nearly equivalent to current laser in situ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章,评审

    doi:10.1016/j.jcrs.2018.07.047

    authors: Moshirfar M,Shah TJ,Masud M,Linn SH,Ronquillo Y,Hoopes PC Sr

    更新日期:2018-11-01 00:00:00

  • Differential optical density of fluid in capsular bag distension syndrome.

    abstract::Capsular bag distension syndrome (CBDS) is a rare complication of cataract surgery due to collection of fluid behind the intraocular lens (IOL). Nd:Yag laser capsulotomy is commonly performed to release the fluid collection; however, the potential risk of infection and inflammation has led to adaptation of numerous su...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1097/j.jcrs.0000000000000362

    authors: Oli A,Malik R,Waikar S

    更新日期:2020-12-01 00:00:00

  • Prospective visual evaluation of apodized diffractive intraocular lenses.

    abstract:PURPOSE:To evaluate distance, intermediate, and near visual performance in patients who had multifocal apodized diffractive intraocular lens (IOL) implantation. SETTING:Fernández-Vega Ophthalmological Institute, Oviedo, Spain. METHODS:The best corrected distance visual acuity, best distance-corrected near visual acui...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2007.03.034

    authors: Alfonso JF,Fernández-Vega L,Baamonde MB,Montés-Micó R

    更新日期:2007-07-01 00:00:00

  • Lens capsule-related complications of femtosecond laser-assisted capsulotomy versus manual capsulorhexis for white cataracts.

    abstract:PURPOSE:Comparison of lens capsule-related complications resulting from femtosecond laser-assisted capsulotomy and manual capsulorhexis in patients with white cataracts. SETTING:Eye Center, Second Affiliated Hospital, Zhejiang Medical School, Hangzhou, China. DESIGN:Prospective consecutive nonrandomized comparative c...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2018.10.037

    authors: Zhu Y,Chen X,Chen P,Xu W,Shentu X,Yu Y,Yao K

    更新日期:2019-03-01 00:00:00

  • Repeatability and reproducibility of manifest refraction.

    abstract:PURPOSE:To evaluate the intraexaminer repeatability and the interobserver reproducibility of manifest refraction. SETTING:Tertiary referral center. DESIGN:Retrospective study. METHODS:Patients attending at least 2 preoperative refractions before undergoing subsequent refractive surgery were included. All manifest re...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1097/j.jcrs.0000000000000343

    authors: Taneri S,Arba-Mosquera S,Rost A,Kießler S,Dick HB

    更新日期:2020-12-01 00:00:00

  • Transillumination defects following in-the-bag single-piece intraocular lens implantation and trabeculectomy with mini-shunt.

    abstract::An 80-year-old woman of mixed ethnicity developed significant iris transillumination defects following phacoemulsification with in-the-bag implantation of a single-piece hydrophobic acrylic intraocular lens (IOL) and trabeculectomy with insertion of an Express mini-shunt. With the exception of modest anterior chamber ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2012.10.014

    authors: Rosenthal KJ,Venkateswaran N

    更新日期:2013-01-01 00:00:00

  • Additional long-term follow-up on the IOLAB Azar 91Z anterior chamber intraocular lens.

    abstract::A retrospective study of 98 91Z anterior chamber intraocular lenses used with intracapsular cataract extraction was performed. Minimum follow-up was 12 months and average follow-up was two years seven months. These patients were part of a group of 113 91Z patients previously reported with minimum six-months follow-up ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(86)80104-3

    authors: Hagan JC 3rd

    更新日期:1986-07-01 00:00:00

  • Temporal versus superior approach phacoemulsification: short-term postoperative astigmatism.

    abstract:PURPOSE:To compare short-term clinical, postoperative astigmatism, and uncorrected visual acuity results 2 months after no-stitch phacoemulsification using a temporal clear corneal approach and poly(methyl methacrylate) (PMMA) intraocular lens (IOL) implantation through a 5.2 mm incision with those after no-stitch supe...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1016/s0886-3350(97)80352-5

    authors: Cillino S,Morreale D,Mauceri A,Ajovalasit C,Ponte F

    更新日期:1997-03-01 00:00:00

  • Femtosecond laser-assisted technique for performing bag-in-the-lens intraocular lens implantation.

    abstract::We describe a technique for femtosecond laser-assisted bag-in-the-lens (BIL) intraocular lens (IOL) implantation. Anterior capsulotomy and lens division into small pieces are performed by the laser. A fluid-filled interface makes it possible to re-dock the laser to the eye for posterior capsulotomy after the eye has b...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2013.07.014

    authors: Dick HB,Canto AP,Culbertson WW,Schultz T

    更新日期:2013-09-01 00:00:00

  • Endothelial cell density after photorefractive keratectomy for moderate myopia using a 213 nm solid-state laser system.

    abstract:PURPOSE:To evaluate whether photorefractive keratectomy (PRK) for moderate myopia using a solid-state laser with a wavelength of 213 nm alters the corneal endothelial cell density. SETTING:University refractive surgery center. METHODS:The corneal endothelium was analyzed preoperatively and 1, 6, and 12 months postope...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.jcrs.2007.06.042

    authors: Tsiklis NS,Kymionis GD,Pallikaris AI,Diakonis VF,Ginis HS,Kounis GA,Panagopoulou SI,Pallikaris IG

    更新日期:2007-11-01 00:00:00

  • Collagen copolymer toric posterior chamber phakic intraocular lens in eyes with keratoconus.

    abstract:PURPOSE:To assess the safety, efficacy, stability, and predictability of collagen copolymer toric phakic intraocular lens (pIOL) implantation to correct myopia and astigmatism in eyes with keratoconus. SETTING:Fernández-Vega Ophthalmological Institute, Oviedo, Spain. METHODS:This prospective study comprised keratocon...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2009.11.032

    authors: Alfonso JF,Fernández-Vega L,Lisa C,Fernandes P,González-Méijome JM,Montés-Micó R

    更新日期:2010-06-01 00:00:00