Light transmittance of 1-piece hydrophobic acrylic intraocular lenses with surface light scattering removed from cadaver eyes.

Abstract:

PURPOSE:To assess the potential effect of surface light scattering on light transmittance of 1-piece hydrophobic acrylic intraocular lenses (IOLs) with or without a blue-light filter. SETTING:John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. DESIGN:Experimental study. METHODS:Intraocular lenses were obtained from human cadavers (49 IOLs total; 36 with blue-light filter) and from finished-goods inventory (controls). The IOLs were removed from cadaver eyes and the power and model matched to unused controls. After surface proteins were removed, the IOLs were hydrated for 24 hours at room temperature. Surface light scattering was measured with a Scheimpflug camera (EAS-1000 Anterior Segment Analysis System). Light transmittance was measured with a Lambda 35 UV/Vis spectrophotometer (single-beam configuration; RSA-PE-20 integrating sphere). RESULTS:Hydrated scatter values ranged from 4.8 to 202.5 computer-compatible tape (CCT) units for explanted IOLs with blue-light filter and 1.5 to 11.8 CCT units for controls; values ranged from 6.0 to 137.5 CCT units for explanted IOLs without a blue-light filter and 3.5 to 9.6 CCT units for controls. In both groups, there was a tendency toward increasing scatter values with increasing postoperative time. No differences in light transmittance were observed between explanted IOLs and controls in both groups (IOLs with blue-light filter: P=.407; IOL with no blue-light filter: P=.487; both paired t test). CONCLUSIONS:Although surface light scattering of explanted IOLs was significantly higher than that of controls and appeared to increase with time, no effect was observed on light transmittance of 1-piece hydrophobic acrylic IOLs with or without a blue-light filter.

authors

Werner L,Morris C,Liu E,Stallings S,Floyd A,Ollerton A,Leishman L,Bodnar Z

doi

10.1016/j.jcrs.2013.05.050

subject

Has Abstract

pub_date

2014-01-01 00:00:00

pages

114-20

issue

1

eissn

0886-3350

issn

1873-4502

pii

S0886-3350(13)01308-4

journal_volume

40

pub_type

杂志文章
  • Phacoemulsification in eyes with a small pupil.

    abstract:PURPOSE:To evaluate the intraoperative difficulties and long-term outcome of phacoemulsification through a small pupil using minimal iris manipulation. SETTINGS:Iladevi Cataract & IOL Research Centre, Ahmedabad, India. METHODS:This prospective study included 30 consecutive eyes with a maximally dilated pupil size of ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(00)00361-8

    authors: Vasavada A,Singh R

    更新日期:2000-08-01 00:00:00

  • Incidence of acute postoperative cystoid macular edema in clinical practice.

    abstract:PURPOSE:To measure the incidence of acute postoperative cystoid macular edema (CME) in clinical practice. SETTING:Private clinical practice, Eugene, Oregon, USA. DESIGN:Retrospective chart review. METHODS:The electronic medical records database was searched for the charts of all patients having cataract surgery duri...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2012.07.029

    authors: Packer M,Lowe J,Fine H

    更新日期:2012-12-01 00:00:00

  • Ophthalmic Simulated Surgical Competency Assessment Rubric for manual small-incision cataract surgery.

    abstract:PURPOSE:To develop and test the validity of a surgical competency assessment tool for simulated small-incision cataract surgery (SICS). SETTING:Participating ophthalmologists contributed from 8 countries. DESIGN:Qualitative and quantitative development and evaluation of face and content validity of an assessment rubr...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章,多中心研究

    doi:10.1016/j.jcrs.2019.04.010

    authors: Dean WH,Murray NL,Buchan JC,Golnik K,Kim MJ,Burton MJ

    更新日期:2019-09-01 00:00:00

  • Bilateral Artisan lens for aphakia and megalocornea: Long-term follow-up.

    abstract::We received approval from the U.S. implant Food and Drug Administration and the University's Institutional Review Board to the Artisan lens (Ophtec BV) in both eyes of a patient who was aphakic and had megalocornea. No other intraocular lens would easily solve this patient's need because of the large anterior segment....

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2005.12.060

    authors: Oetting TA,Newsom TH

    更新日期:2006-03-01 00:00:00

  • Personal results with the 3M diffractive multifocal intraocular lens.

    abstract::The results of implanting 269 3M multifocal intraocular lenses are analyzed and compared with those of monofocal lenses. Visual acuity results were excellent. In the best case group, 98% of eyes obtained a distance visual acuity of 20/40 or better and 96% of best cases obtained a functional reading capacity without su...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(13)81044-9

    authors: Goes F

    更新日期:1991-09-01 00:00:00

  • Comparison of a trifocal intraocular lens with a +3.0 D bifocal IOL: results of a prospective randomized clinical trial.

    abstract:PURPOSE:To compare visual outcomes in patients with cataract surgery and bilateral implantation of a trifocal or bifocal intraocular lens (IOL). SETTING:University Eye Clinic Maastricht, the Netherlands. DESIGN:Prospective randomized clinical trial. METHODS:Eyes with cataract and less than 1.0 diopter (D) of corneal...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.jcrs.2015.08.011

    authors: Jonker SM,Bauer NJ,Makhotkina NY,Berendschot TT,van den Biggelaar FJ,Nuijts RM

    更新日期:2015-08-01 00:00:00

  • Comparison of the Storz bifocal zonal and the 3M diffractive multifocal intraocular lenses.

    abstract::Visual acuity and contrast sensitivity after cataract surgery were evaluated in best-case eyes that received a Storz bifocal zonal intraocular lens (IOL) or a 3M diffractive multifocal IOL. A group of eyes with a monofocal IOL was used as a control. Postoperatively, all eyes had a best corrected visual acuity of 20/40...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(13)80536-6

    authors: Boesten IE,Beekhuis WH,Hassmann E,Pameyer JH,Baarsma GS

    更新日期:1995-07-01 00:00:00

  • Efficacy and safety of a new selective laser device to create anterior capsulotomies in cataract patients.

    abstract:PURPOSE:To compare the efficacy and safety of anterior capsulotomy creation with a new selective laser device (CAPSULaser) with those of manual capsulotomies. SETTING:GEMINI Eye Clinic, Zlin, Czech Republic. DESIGN:Prospective case series. METHODS:Patients were placed in cohorts based on age and cataract grade and r...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2018.12.012

    authors: Stodulka P,Packard R,Mordaunt D

    更新日期:2019-05-01 00:00:00

  • In vitro antimicrobial analysis of aqueous humor after topical application of moxifloxacin hydrochloride 0.5%.

    abstract:PURPOSE:To evaluate the in vitro antimicrobial activity of aqueous humor in patients who had preoperative topical application of moxifloxacin hydrochloride 0.5%. SETTING:Department of Ophthalmology, Santa Casa de Misericórdia de São Paulo, Brazil. DESIGN:Comparative case series. METHODS:Twenty-nine eyes from 29 cata...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2014.11.010

    authors: de Miranda AP,Silva CB,Mimica LM,Moscovici BK,Malavazzi GR,Hida RY

    更新日期:2015-01-01 00:00:00

  • Blue-light filtering intraocular lens in patients with diabetes: contrast sensitivity and chromatic discrimination.

    abstract:PURPOSE:To evaluate potential changes in contrast sensitivity and color discrimination in diabetic patients who had cataract surgery and implantation of the blue-light filtering AcrySof Natural (SN60AT) intraocular lens (IOL) compared with an ultraviolet-only filtering (AcrySof SA60AT) IOL. SETTING:Refractive Surgery ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2005.04.029

    authors: Rodríguez-Galietero A,Montés-Micó R,Muñoz G,Albarrán-Diego C

    更新日期:2005-11-01 00:00:00

  • Vitrectomy-assisted phacoemulsification for lenticular coloboma.

    abstract::We describe a technique to prevent continuous vitreous hydration during phacoemulsification in eyes with lenticular coloboma. The hydration results from communication between the anterior and posterior chambers from the edges of the colobomatous defect. To avoid this, a valved trocar is placed at the pars plana site a...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2016.10.028

    authors: Agarwal A,Narang P,Agarwal A

    更新日期:2017-02-01 00:00:00

  • After-cataract formation in newborn rabbits implanted with intraocular lenses.

    abstract:PURPOSE:Comparison of the after-cataract formation in newborn rabbits implanted with a heparin-surface-modified (HSM) intraocular lens (IOL), a silicone IOL, or no IOL. METHODS:Two groups of 3-week-old rabbits were used. In Group 1 (n = 11), lensectomy was performed in both eyes. One eye was selected at random and an ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(96)80275-6

    authors: Zetterström C,Kugelberg U,Lundgren B,Syrén-Nordqvist S

    更新日期:1996-01-01 00:00:00

  • Change in pupil size after implantation of an iris-fixated toric phakic intraocular lens.

    abstract:PURPOSE:To evaluate the changes in pupil size after implantation of an iris-supported toric phakic intraocular lens (TPIOL) for correction of myopia and hyperopia with astigmatism. SETTING:Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. METHODS:Twenty-two myopic eyes and 9 hyperopic eyes w...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2004.04.040

    authors: Dick HB,Aliyeva S,Tehrani M

    更新日期:2005-02-01 00:00:00

  • Effect of large positioning holes on capsule fixation of plate-haptic intraocular lenses.

    abstract:PURPOSE:To compare the centration and fixation of silicone plate-haptic intraocular lenses (IOLs) with different-sized positioning holes. SETTING:Eye Clinic of the Johannes Gutenberg-University Mainz, Mainz, Germany. METHODS:In a prospective randomized study, 51 Chiroflex C10 and 56 Chiroflex C11 IOLs were implanted ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1016/s0886-3350(00)00496-x

    authors: Schwenn O,Kottler U,Krummenauer F,Dick HB,Pfeiffer N

    更新日期:2000-12-01 00:00:00

  • Repeatability and validity of lens densitometry measured with Scheimpflug imaging.

    abstract:PURPOSE:To assess the repeatability and validity of lens densitometry derived from the Pentacam Scheimpflug imaging system. SETTING:Eye Clinic, Queensland University of Technology, Brisbane, Australia. METHODS:This prospective cross-sectional study evaluated 1 eye of subjects with or without cataract. Scheimpflug mea...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2009.03.017

    authors: Kirkwood BJ,Hendicott PL,Read SA,Pesudovs K

    更新日期:2009-07-01 00:00:00

  • Traumatic subluxation causing variable position of the crystalline lens.

    abstract::We present a case of traumatic lens subluxation that was evident only when the patient was in the supine position. This case illustrates that a crystalline lens with traumatic zonular rupture can change its position depending on the posture of the patient. If such a lens is suspended by the remaining zonules at the su...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(01)01167-1

    authors: Loo AV,Lai JS,Tham CC,Lam DS

    更新日期:2002-06-01 00:00:00

  • T-cut in the bottom of the scleral pocket in combined cataract and glaucoma surgery.

    abstract:PURPOSE:To determine whether radial transsection of the inner lamina of the phaco tunnel (T-cut) allows intraocular pressure (IOP) control in cases of co-existing cataract and glaucoma and to evaluate the results of this glaucoma triple procedure. SETTING:Department of Ophthalmology, Hanusch Hospital, Vienna, Austria....

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(99)00454-x

    authors: Rossmann M,Harrer S,Rigal K

    更新日期:2000-05-01 00:00:00

  • Repositioning and follow-up of intralenticular dexamethasone implant.

    abstract::We report the case of a 54-year-old man who attended our emergency department complaining of severe floaters and decreased vision in his right eye. Seven days earlier, a dexamethasone intravitreal implant (Oxurdex) had been placed for a noninfectious posterior uveitis. Slitlamp examination showed the implant had penet...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2013.06.003

    authors: Munteanu M,Rosca C

    更新日期:2013-08-01 00:00:00

  • Photorefractive keratectomy to treat myopia and astigmatism after radial keratotomy and penetrating keratoplasty.

    abstract::Fifteen eyes with an initial myopia between -5.00 diopters (D) and -12.00 D were treated with radial keratotomy (RK) followed by photorefractive keratectomy (PRK) at least 6 months later and observed for 6 months to 24 months. Five eyes that had penetrating keratoplasty (PKP) were treated for residual ametropia by PRK...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(13)80130-7

    authors: Nordan LT,Binder PS,Kassar BS,Heitzmann J

    更新日期:1995-05-01 00:00:00

  • Rupture of a radial keratotomy incision after 11 years during clear corneal phacoemulsification.

    abstract::We report a case of rupture of a radial keratotomy (RK) incision that occurred during clear corneal phacoemulsification 11 years after the initial surgery. The RK was done in both eyes for correction of high myopia (>8.0 diopters). This was followed by 2 enhancement procedures at 6 month intervals. The patient present...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(01)00763-5

    authors: Behl S,Kothari K

    更新日期:2001-07-01 00:00:00

  • Formula choice: Hoffer Q, Holladay 1, or SRK/T and refractive outcomes in 8108 eyes after cataract surgery with biometry by partial coherence interferometry.

    abstract:PURPOSE:To assess how intraocular lens (IOL) formula choice affects refractive outcomes after cataract surgery using IOLMaster biometry. SETTING:Department of Ophthalmology, Gloucestershire Hospitals NHS Foundation Trust, Cheltenham, United Kingdom. DESIGN:Database study. METHODS:Hypothetical prediction errors were ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2010.07.032

    authors: Aristodemou P,Knox Cartwright NE,Sparrow JM,Johnston RL

    更新日期:2011-01-01 00:00:00

  • Effect of anterior and posterior corneal surface irregularity on vision after Descemet-stripping endothelial keratoplasty.

    abstract:PURPOSE:To evaluate irregularity of the anterior and posterior cornea before and after Descemet-stripping endothelial keratoplasty (DSEK) and its effect on visual acuity. SETTING:Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan. METHODS:Corneal data were acquired using a rotating Scheimpf...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2008.11.062

    authors: Yamaguchi T,Negishi K,Yamaguchi K,Murat D,Uchino Y,Shimmura S,Tsubota K

    更新日期:2009-04-01 00:00:00

  • Prophylactic intracameral cefuroxime. Evaluation of safety and kinetics in cataract surgery.

    abstract:PURPOSE:To evaluate the safety and kinetics of prophylactic intracameral cefuroxime in cataract surgery. SETTING:Department of Ophthalmology, St. Eriks Hospital, Stockholm, Sweden. METHODS:In a nonrandomized observer-masked best-case trial, the visual rehabilitation and the evolution of laser flare intensity and corn...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 临床试验,杂志文章

    doi:10.1016/s0886-3350(01)01270-6

    authors: Montan PG,Wejde G,Setterquist H,Rylander M,Zetterström C

    更新日期:2002-06-01 00:00:00

  • Corneal transillumination: technique to detect big bubble in deep anterior lamellar keratoplasty.

    abstract::Deep anterior lamellar keratoplasty is a widely adopted technique to treat pathologies of the cornea without endothelial cell involvement. This technique has several advantages including longer graft survival without endothelial rejection and lower doses of steroid administration. A transillumination technique was use...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1097/j.jcrs.0000000000000369

    authors: Estrin DA,Szuster NM,Szuster EA

    更新日期:2020-08-03 00:00:00

  • Comparison of ocular wavefront aberrations in subluxated lenses before and after lens extraction with intraocular lens implantation.

    abstract:PURPOSE:To compare the change in ocular higher-order wavefront aberrations (HOAs), visual acuity, and modulation transfer function (MTF) after lens extraction with intraocular lens (IOL) implantation in patients with subluxated lenses. SETTING:Iladevi Cataract & IOL Research Centre, Ahmedabad, India. DESIGN:Prospecti...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2017.12.017

    authors: Srivastava S,Vasavada V,Vasavada V,Vasavada S,Praveen MR,Reddy R,Vasavada AR

    更新日期:2018-03-01 00:00:00

  • Comparative analysis of the clinical outcomes with 2 multifocal intraocular lens models with rotational asymmetry.

    abstract:PURPOSE:To compare the clinical outcomes after cataract surgery with implantation of 2 models of a new rotationally asymmetric multifocal IOL to ascertain which provides better visual performance and patient satisfaction. SETTING:Vissum Instituto Oftalmologico de Alicante, Alicante, Spain. DESIGN:Comparative case ser...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2011.03.054

    authors: Alió JL,Plaza-Puche AB,Piñero DP,Javaloy J,Ayala MJ

    更新日期:2011-09-01 00:00:00

  • Cystotome-assisted prechop technique.

    abstract:UNLABELLED:We describe a manual prechop technique to divide the nucleus using a cystotome. In the cystotome-assisted prechop technique, after the capsulorhexis, the surgeon-bent cystotome is inserted into the lens while the Nagahara chopper is set around the lens equator. The cystotome and the chopper are then brought ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2014.11.015

    authors: Chen X,Liu B,Xiao Y,Qi Y,Hao X,Shi L,Wu L

    更新日期:2015-01-01 00:00:00

  • Photorefractive keratectomy for residual myopia after radial keratotomy.

    abstract:PURPOSE:To evaluate the results of photorefractive keratectomy (PRK) to treat undercorrected radial keratotomy (RK). SETTING:Instituto de Oftalmologia Tadeu Cvintal, São Paulo, Brazil. METHODS:A consecutive series of 28 eyes that had PRK to treat residual myopia after RK were studied. Refractive visual and safety dat...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(96)80189-1

    authors: John ME,Martines E,Cvintal T

    更新日期:1996-09-01 00:00:00

  • Medical control of intraocular pressure after cataract surgery.

    abstract:PURPOSE:To compare the effectiveness of 2 medications commonly used to prevent intraocular pressure (IOP) elevation in the early period after cataract surgery. SETTING:Palo Alto Veterans Affairs Health Care System, Palo Alto, California, USA. METHODS:This prospective study comprised 202 eyes of patients scheduled for...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1016/s0886-3350(98)80172-7

    authors: Byrd S,Singh K

    更新日期:1998-11-01 00:00:00

  • Actual and theoretical risks for visual loss following use of the implantable contact lens for moderate to high myopia.

    abstract:PURPOSE:To estimate the actual and theoretical risks for visual loss associated with use of the implantable contact lens (ICL). SETTING:Multicenter clinical trial data. METHODS:An established model for estimating the risk for visual loss associated with retinal detachment (RD) following clear lens extraction (CLE) wa...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章,评审

    doi:10.1016/s0886-3350(02)02040-0

    authors: Sanders DR

    更新日期:2003-07-01 00:00:00