Delayed intraocular lens dislocation after neodymium:YAG capsulotomy.

Abstract:

:A poly(methyl methacrylate)(PMMA) intraocular lens (IOL) dislocated into the vitreous cavity in 2 patients after a neodymium:YAG (Nd:YAG) laser posterior capsulotomy. In Case 1, the capsulotomy was performed 19 months after extracapsular cataract extraction (ECCE) and sulcus fixation of an IOL. Six months later the IOL dislocated posteriorly. In Case 2, ECCE with intracapsular IOL implantation was followed 4 years later by an Nd:YAG capsulotomy; 6 months later the IOL dislocated into the vitreous cavity within the intact capsular bag. Different mechanisms were responsible for the dislocation: in case 1, radial tearing of the large capsular defect with IOL loosening and dislocation into the vitreous cavity; in Case 2, zonulysis and IOL dislocation within the intact capsular bag. A neodymium:YAG capsulotomy may cause delayed IOL dislocation into the vitreous cavity.

authors

Framme C,Hoerauf H,Roider J,Laqua H

doi

10.1016/s0886-3350(98)80182-x

subject

Has Abstract

pub_date

1998-11-01 00:00:00

pages

1541-3

issue

11

eissn

0886-3350

issn

1873-4502

pii

S0886-3350(98)80182-X

journal_volume

24

pub_type

杂志文章
  • Effect of laser in situ keratomileusis on optic nerve head topography and retinal nerve fiber layer thickness.

    abstract:PURPOSE:To determine whether laser in situ keratomileusis (LASIK) produces significant changes in optic nerve head (ONH) topography and retinal nerve fiber layer (RNFL) thickness as measured by the Heidelberg Retina Tomograph (HRT) and to evaluate the potential neuroprotective effect of topical betaxolol on these chang...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1016/s0886-3350(03)00466-8

    authors: Whitson JT,McCulley JP,Cavanagh HD,Song J,Bowman RW,Hertzog L

    更新日期:2003-12-01 00:00:00

  • Effect of mitomycin-C on the variance in refractive outcomes after photorefractive keratectomy.

    abstract:PURPOSE:To compare the variance in manifest refraction spherical equivalent (MRSE) after photorefractive keratectomy (PRK) with mitomycin-C (MMC), PRK without MMC, and laser in situ keratomileusis (LASIK) for the treatment of myopic astigmatism. SETTING:Jules Stein Eye Institute, University of California, Los Angeles,...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2014.02.048

    authors: Sy ME,Zhang L,Yeroushalmi A,Huang D,Hamilton DR

    更新日期:2014-12-01 00:00:00

  • Transscleral fixation of foldable intraocular lenses.

    abstract:PURPOSE:To report the results of transscleral implantation of foldable intraocular lenses (IOLs). SETTING:Department of Ophthalmology Dokuz Eylül University School of Medicine, Izmir, Turkey. METHODS:Twenty eyes of 20 patients had transscleral fixation of a foldable IOL combined with conventional 3-port pars plana vi...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2003.09.050

    authors: Kaynak S,Ozbek Z,Pasa E,Oner FH,Cingil G

    更新日期:2004-04-01 00:00:00

  • Synthetic cataract teaching system for phacoemulsification.

    abstract::This paper describes a surgical training system for teaching and practicing the necessary skills to perform phacoemulsification, endocapsular phacoemulsification, and small incision intraocular lens insertion techniques. The surgical system includes head, bilateral globes, removable corneas, and replaceable synthetic ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(88)80100-7

    authors: Maloney WF,Hall D,Parkinson DB

    更新日期:1988-03-01 00:00:00

  • Tissue damage at anterior capsule edges after continuous curvilinear capsulorhexis, high-frequency capsulotomy, and erbium:YAG laser capsulotomy.

    abstract:PURPOSE:To compare the effect of erbium:YAG laser photocapsulotomy (ELC), continuous curvilinear capsulorhexis (CCC), and high-frequency capsulotomy (HFC) on anterior capsule edges using light microscopy (LM) and transmission electron microscopy (TEM). SETTING:Department of Ophthalmology, Department of Histology and E...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/S0886-3350(03)00652-7

    authors: Radner G,Amon M,Stifter E,Nepp J,Diendorfer G,Mallinger R,Radner W

    更新日期:2004-01-01 00:00:00

  • Effect of a single-piece aspheric hydrophobic acrylic intraocular lens design on centration and rotation.

    abstract:PURPOSE:To assess the rotation and centration stability of the new design features of a 1-piece aspheric hydrophobic acrylic intraocular lens (IOL). SETTING:National Eye Hospital, Cairo, Egypt. DESIGN:Randomized clinical trial. METHODS:Patients in this study had implantation of a 1-piece Tecnis 1 ZCB00 IOL or a 3-pi...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.jcrs.2012.09.020

    authors: Roshdy MM,Riad RF,Morkos FF,Hassouna AK,Wahba SS

    更新日期:2013-03-01 00:00:00

  • Bacterial-sized particle inflow through sutured clear corneal incisions in a laboratory human model.

    abstract:PURPOSE:To determine the effectiveness of a single radial suture placement in 2 clear corneal incision (CCI) configurations in preventing inflow of bacterial-sized particles. SETTING:Wilmer Eye Institute, Baltimore, Maryland, USA. DESIGN:Experimental study. METHODS:Ten human globes were used. Two 25-gauge needles co...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2010.11.042

    authors: May WN,Castro-Combs J,Kashiwabuchi RT,Hertzog H,Tattiyakul W,Kahn YA,Hirai F,Gower EW,Behrens A

    更新日期:2011-06-01 00:00:00

  • Biomechanical parameters of the cornea after collagen crosslinking measured by waveform analysis.

    abstract:PURPOSE:To compare 2 corneal biomechanical parameters--corneal hysteresis (CH) and corneal resistance factor (CRF)--before and after collagen crosslinking (CXL) for keratoconus. SETTING:Eye Research Center of Mashhad University of Medical Sciences, Khatam-al-Anbia Eye Hospital, Mashhad, and Department of Ophthalmology...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2010.06.056

    authors: Sedaghat M,Naderi M,Zarei-Ghanavati M

    更新日期:2010-10-01 00:00:00

  • Glistenings in foldable intraocular lenses.

    abstract:PURPOSE:To evaluate the formation of glistenings in foldable intraocular lenses (IOLs) of various materials after cataract surgery. SETTING:University Eye Clinic of Trieste, Trieste, Italy. METHODS:In this prospective study, 273 patients were randomized to have implantation of 1 of 7 types of foldable IOLs in the cap...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1016/s0886-3350(02)01353-6

    authors: Tognetto D,Toto L,Sanguinetti G,Ravalico G

    更新日期:2002-07-01 00:00:00

  • Long-term effect of phacoemulsification on intraocular pressure using phakic fellow eye as control.

    abstract:PURPOSE:To investigate the long-term effect of phacoemulsification on intraocular pressure (IOP) in patients with ocular hypertension and open-angle glaucoma. SETTING:Three multispecialty ophthalmology practices and one glaucoma specialty group. DESIGN:Retrospective comparative case series. METHODS:Review of medical...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章,多中心研究

    doi:10.1016/j.jcrs.2012.01.016

    authors: Chang TC,Budenz DL,Liu A,Kim WI,Dang T,Li C,Iwach AG,Radhakrishnan S,Singh K

    更新日期:2012-05-01 00:00:00

  • Predictability of the vault after posterior chamber phakic intraocular lens implantation using anterior segment optical coherence tomography.

    abstract:PURPOSE:To determine whether vault measurements after placement of a hole implantable collamer lens (hole ICL) (KS-AquaPORT) can be predicted by angle-to-angle (ATA) and white-to-white (WTW) measurements obtained with anterior segment optical coherence tomography (AS-OCT). SETTING:Sanno Hospital, Tokyo, Japan. DESIGN...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2019.02.020

    authors: Igarashi A,Shimizu K,Kato S,Kamiya K

    更新日期:2019-08-01 00:00:00

  • Anterior segment optical coherence tomography findings of reverse pupillary block after scleral-fixated sutured posterior chamber intraocular lens implantation.

    abstract:PURPOSE:To evaluate findings of reverse pupillary block after scleral-fixated sutured posterior chamber intraocular lens (PC IOL) implantation using anterior segment optical coherence tomography (AS-OCT) and report a possible association with postoperative complications. SETTING:Department of Ophthalmology, Kanazawa U...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2009.04.030

    authors: Higashide T,Shimizu F,Nishimura A,Sugiyama K

    更新日期:2009-09-01 00:00:00

  • In vitro optical quality assessment of a monofocal IOL sutured to an artificial iris.

    abstract:PURPOSE:To assess whether the combined implantation of a monofocal IOL and an artificial iris had an effect on the IOL's optical performance. SETTING:David J. Apple International Laboratory for Ocular Pathology, Heidelberg, Germany. DESIGN:In vitro laboratory study. METHODS:IOL optical quality was assessed using an ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1097/j.jcrs.0000000000000287

    authors: Mayer C,Son HS,Łabuz G,Yildirim TM,Auffarth GU,Khoramnia R

    更新日期:2020-08-01 00:00:00

  • Visual outcomes after femtosecond laser in situ keratomileusis flap complications.

    abstract:PURPOSE:To compare visual outcomes in normal and complicated laser in situ keratomileusis (LASIK) flaps constructed with a femtosecond laser. SETTING:Wilford Hall Ambulatory Surgical Center, San Antonio, Texas. DESIGN:Retrospective chart review. METHODS:The main outcome measures were uncorrected distance visual acui...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2015.05.024

    authors: Jadav DS,Desai N,Taylor KR,Caldwell MC,Panday VA,Reilly CD

    更新日期:2015-11-01 00:00:00

  • Determinants of visual outcome after pars plana vitrectomy for posteriorly dislocated lens fragments in phacoemulsification.

    abstract:PURPOSE:To evaluate the visual outcome of patients with posteriorly dislocated lens fragments after phacoemulsification managed with pars plana vitrectomy (PPV) and identify risk factors for poor visual outcome. SETTING:Vitreo-Retinal Service, St. Paul Eye Unit, Liverpool, United Kingdom. METHODS:The medical records ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(01)00750-7

    authors: Al-Khaier A,Wong D,Lois N,Cota N,Yang YC,Groenewald C

    更新日期:2001-08-01 00:00:00

  • Clinical outcomes after bilateral implantation of an apodized +3.0 D toric diffractive multifocal intraocular lens.

    abstract:PURPOSE:To assess visual outcomes after bilateral implantation of an apodized +3.0 diopter (D) addition power toric diffractive multifocal intraocular lens (IOL). SETTING:Five study sites in Europe and South America. DESIGN:Cohort study. METHODS:Patients had bilateral implantation of the AcrySof(®) IQ ReSTOR(®)+3.0 ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1016/j.jcrs.2013.06.026

    authors: Alfonso JF,Knorz M,Fernandez-Vega L,Rincón JL,Suarez E,Titke C,Kohnen T

    更新日期:2014-01-01 00:00:00

  • Model of anesthesia care that combines anesthesiologists and registered nurses during cataract surgery.

    abstract:PURPOSE:To determine the safety and practicality of a combined anesthesiologist and registered nurse model of anesthesia care in cataract surgery. SETTING:Mayo Clinic, Rochester, Minnesota, USA. DESIGN:Case series. METHODS:This retrospective review comprised consecutive patients having phacoemulsification cataract s...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2010.09.021

    authors: Erie AJ,McHugh R,Warner M,Erie JC

    更新日期:2011-03-01 00:00:00

  • Neutralization method for detecting the incidence of color perception changes after cataract surgery.

    abstract:PURPOSE:To evaluate and compare the incidence of cyanopsia using the neutralization method in eyes in which clear or yellow intraocular lenses (IOLs) were implanted. SETTING:Miyata Eye Clinic, Hiroshima, Japan. DESIGN:Retrospective comparative study. METHODS:Patients who had cataract surgery with the implantation of...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2014.07.040

    authors: Miyata A

    更新日期:2015-04-01 00:00:00

  • Late bacterial keratitis after implantation of intrastromal corneal ring segments.

    abstract::We report a case of bacterial keratitis that occurred after implantation of intrastromal corneal ring segments (Intacs). The patient presented with decreased vision, inflammation, and stromal infiltrates localized at the extremity of an Intacs channel 3 months after surgery. Culture were positive for Clostridium perfr...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(02)01484-0

    authors: Bourcier T,Borderie V,Laroche L

    更新日期:2003-02-01 00:00:00

  • Effect of high vacuum and aspiration on phacoemulsification efficiency and chatter using a transversal ultrasound machine.

    abstract:PURPOSE:To examine the role of high vacuum and aspiration settings on efficiency using a transversal ultrasound (US) machine. SETTING:John A. Moran Eye Center Laboratory, University of Utah, Salt Lake City, Utah, USA. DESIGN:Experimental study. METHODS:Porcine lens nuclei were incubated in formalin for 2 hours and t...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2018.05.031

    authors: Kabbara S,Heczko JB,Bernhisel AA,Barlow WR,Zaugg B,Pettey JH,Olson RJ

    更新日期:2018-11-01 00:00:00

  • Effect of residual ocular spherical aberration on objective and subjective quality of vision in pseudophakic eyes.

    abstract:PURPOSE:To determine the level of residual spherical aberration that gives the best objective and subjective quality of image after cataract surgery with intraocular lens (IOL) implantation. SETTING:Department of Ophthalmology, CHU Bretonneau, Tours, France. DESIGN:Cohort study. METHODS:Six months after microincisio...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2010.12.056

    authors: Nochez Y,Majzoub S,Pisella PJ

    更新日期:2011-06-01 00:00:00

  • Long-term therapeutic efficacy of phacoemulsification with intraocular lens implantation in patients with phacomorphic glaucoma.

    abstract:PURPOSE:To evaluate the long-term therapeutic efficacy of phacoemulsification with intraocular lens (IOL) implantation in treating phacomorphic glaucoma. SETTING:Ophthalmology Department, Maryknoll Hospital, Busan, Korea. METHODS:This study evaluated eyes that had phacoemulsification with IOL implantation to treat ph...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2009.11.023

    authors: Lee SJ,Lee CK,Kim WS

    更新日期:2010-05-01 00:00:00

  • Fungal keratitis after laser in situ keratomileusis.

    abstract::A 22-year-old woman presented with pain, redness, watering, and decrease in vision in her left eye 15 days after laser in situ keratomileusis for myopia. Slitlamp examination showed a central full-thickness infiltrate with hyphate edges. Microscopic examination of corneal scrapings from the edge and underneath the fla...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(99)00459-9

    authors: Sridhar MS,Garg P,Bansal AK,Sharma S

    更新日期:2000-04-01 00:00:00

  • Bilateral Artisan lens for aphakia and megalocornea: Long-term follow-up.

    abstract::We received approval from the U.S. implant Food and Drug Administration and the University's Institutional Review Board to the Artisan lens (Ophtec BV) in both eyes of a patient who was aphakic and had megalocornea. No other intraocular lens would easily solve this patient's need because of the large anterior segment....

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2005.12.060

    authors: Oetting TA,Newsom TH

    更新日期:2006-03-01 00:00:00

  • Contrast sensitivity measured by 2 methods after photorefractive keratectomy.

    abstract:PURPOSE:To study contrast sensitivity in eyes that had flying-spot excimer laser photorefractive keratectomy (PRK) and to compare a subjective method (Vision Contrast Test System [VCTS] 6500) and an objective method (visual evoked potential [VEP]) of measuring contrast sensitivity. SETTING:Istituto Clinica Oculistica,...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(00)00405-3

    authors: Vetrugno M,Quaranta GM,Maino A,Mossa F,Cardia L

    更新日期:2000-06-01 00:00:00

  • Four-point fixation of posterior chamber intraocular lenses in children with unilateral aphakia.

    abstract:PURPOSE:To evaluate the results of 4-point scleral fixation of posterior chamber intraocular lenses (PC IOLs) in children. SETTING:Mansoura Ophthalmic Center, Mansoura University, Mansoura, Egypt. METHODS:This retrospective study comprised 20 aphakic eyes of 20 children. Preoperative investigations proved the absence...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(02)01531-6

    authors: Sewelam A

    更新日期:2003-02-01 00:00:00

  • Elimination of hydroxypropyl methylcellulose from the anterior chamber of the rabbit.

    abstract::The elimination of hydroxypropyl methylcellulose (HPMC) of molecular weight 86,000 daltons (2%, viscosity 4,000 centipoises; 2.5%, 15,000 centipoises) and 120,000 daltons (2%, 15,000 centipoises) from the anterior chamber of rabbit eyes was determined colorimetrically and was nearly complete by 24 hours. The eliminati...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(89)80009-4

    authors: Fernandez-Vigo J,Refojo MF,Jumblatt M

    更新日期:1989-03-01 00:00:00

  • Recurrent iritis after implantation of an iris-fixated phakic intraocular lens for the correction of myopia Case report and clinicopathologic correlation.

    abstract::The iris-claw intraocular lens (IOL) was recently approved by the U.S. Food and Drug Administration for the correction of refractive disorders. Previous reports are not uniform regarding its potential to induce inflammatory reaction. We report the case of a young healthy patient who experienced persistent and intolera...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2006.02.079

    authors: Kleinmann G,Apple DJ,Mackool RJ

    更新日期:2006-08-01 00:00:00

  • Nucleus-splitting phacoemulsification technique.

    abstract::A technique for phacoemulsification that can be used with or without capsulorhexis and that allows surgery to be performed at the 12 o'clock position is described. Following central sculpting, the nucleus is tipped superiorly to the level of the iris plane with a second instrument and the phacoemulsification tip. The ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(13)81054-1

    authors: Smith SG

    更新日期:1991-09-01 00:00:00

  • Fracture and dislocation of a glass intraocular lens optic as a complication of neodymium:YAG laser posterior capsulotomy: Case report and literature review.

    abstract:UNLABELLED:An 83-year-old man presented with a 1-year history of blurry vision in his left eye. Bilateral cataract surgery and ciliary sulcus posterior chamber intraocular lens (IOL) implantation had been performed 11 years earlier. The corrected distance visual acuity (CDVA) was 20/60 in the left eye. Slitlamp examina...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章,评审

    doi:10.1016/j.jcrs.2015.09.013

    authors: Singh H,Kwan SL,Tam D,Mamalis N,MacLean K,Ahmed II

    更新日期:2015-10-01 00:00:00