Echocardiographic strain and strain-rate imaging: a new tool to study regional myocardial function.

Abstract:

:Ultrasonic imaging is the noninvasive clinical imaging modality of choice for diagnosing heart disease. At present, two-dimensional ultrasonic grayscale images provide a relatively cheap, fast, bedside method to study the morphology of the heart. Several methods have been proposed to assess myocardial function. These have been based on either grayscale or motion (velocity) information measured in real-time. However, the quantitative assessment of regional myocardial function remains an important goal in clinical cardiology. To do this, ultrasonic strain and strain-rate imaging have been introduced. In the clinical setting, these techniques currently only allow one component of the true three-dimensional deformation to be measured. Clinical, multidimensional strain (rate) information can currently thus only be obtained by combining data acquired using different transducer positions. Nevertheless, given the appropriate postprocessing, the clinical value of these techniques has already been shown. Moreover, multidimensional strain and strain-rate estimation of the heart in vivo by means of a single ultrasound acquisition has been shown to be feasible. In this paper, the new techniques of ultrasonic strain rate and strain imaging of the heart are reviewed in terms of definitions, data acquisition, strain-rate estimation, postprocessing, and parameter extraction. Their clinical validation and relevance will be discussed using clinical examples on relevant cardiac pathology. Based on these examples, suggestions are made for future developments of these techniques.

journal_name

IEEE Trans Med Imaging

authors

D'hooge J,Bijnens B,Thoen J,Van de Werf F,Sutherland GR,Suetens P

doi

10.1109/TMI.2002.804440

subject

Has Abstract

pub_date

2002-09-01 00:00:00

pages

1022-30

issue

9

eissn

0278-0062

issn

1558-254X

journal_volume

21

pub_type

杂志文章
  • Virtual tagging: numerical considerations and phantom validation.

    abstract::This paper presents a virtual tagging framework for measuring, as well as visualising, myocardial deformation using magnetic resonance (MR) velocity imaging. Tagging grids are allocated artificially according to the deformation gradient with varying shapes and densities. The control points are then deformed such that ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2002.804429

    authors: Masood S,Gao J,Yang GZ

    更新日期:2002-09-01 00:00:00

  • Novel scatter compensation of list-mode PET data using spatial and energy dependent corrections.

    abstract::With the widespread use of positron emission tomography (PET) crystals with greatly improved energy resolution (e.g., 11.5% with LYSO as compared to 20% with BGO) and of list-mode acquisitions, the use of the energy of individual events in scatter correction schemes becomes feasible. We propose a novel scatter approac...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2010.2095025

    authors: Guérin B,El Fakhri G

    更新日期:2011-03-01 00:00:00

  • Reducing the effects of scattered photons in X-ray projection imaging.

    abstract::An iterative algorithm is introduced which can compute and subtract the scatter bias. It is assumed that the scatter-free image is spatially bounded and anything outside the boundary is the result of recorded scattered photons. This information and the fact that the scatter distribution does not have appreciable high-...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.20362

    authors: Fahimi H,Macovski A

    更新日期:1989-01-01 00:00:00

  • Self-stabilizing colonic capsule endoscopy: pilot study of acute canine models.

    abstract::Video capsule endoscopy (VCE) is a noninvasive method for examining the gastrointestinal tract which has been successful in small intestine studies. Recently, VCE has been attempted in the colon. However, the capsule often tumbles in the wider colonic lumen, resulting in missed regions. Self-stabilizing VCE is a novel...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2163165

    authors: Filip D,Yadid-Pecht O,Andrews CN,Mintchev MP

    更新日期:2011-12-01 00:00:00

  • Precise robot-assisted guide positioning for distal locking of intramedullary nails.

    abstract::This paper presents a novel image-guided robot-based system to assist orthopedic surgeons in performing distal locking of long bone intramedullary nails. The system consists of a bone-mounted miniature robot fitted with a drill guide that provides rigid mechanical guidance for hand-held drilling of the distal screws' ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2005.844922

    authors: Yaniv Z,Joskowicz L

    更新日期:2005-05-01 00:00:00

  • Probabilistic sparse matching for robust 3D/3D fusion in minimally invasive surgery.

    abstract::Classical surgery is being overtaken by minimally invasive and transcatheter procedures. As there is no direct view or access to the affected anatomy, advanced imaging techniques such as 3D C-arm computed tomography (CT) and C-arm fluoroscopy are routinely used in clinical practice for intraoperative guidance. However...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2343936

    authors: Neumann D,Grbic S,John M,Navab N,Hornegger J,Ionasec R

    更新日期:2015-01-01 00:00:00

  • Exact frequency-domain reconstruction for thermoacoustic tomography--II: Cylindrical geometry.

    abstract::Microwave-induced thermoacoustic tomography (TAT) in a cylindrical configuration is developed to image biological tissue. Thermoacoustic signals are acquired by scanning a flat ultrasonic transducer. Using a new expansion of a spherical wave in cylindrical coordinates, we apply the Fourier and Hankel transforms to TAT...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2002.801171

    authors: Xu Y,Xu M,Wang LV

    更新日期:2002-07-01 00:00:00

  • Improving Registration Robustness for Image-Guided Liver Surgery in a Novel Human-to-Phantom Data Framework.

    abstract::In open image-guided liver surgery (IGLS), a sparse representation of the intraoperative organ surface can be acquired to drive image-to-physical registration. We hypothesize that uncharacterized error induced by variation in the collection patterns of organ surface data limits the accuracy and robustness of an IGLS r...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2668842

    authors: Collins JA,Weis JA,Heiselman JS,Clements LW,Simpson AL,Jarnagin WR,Miga MI

    更新日期:2017-07-01 00:00:00

  • Increased spatial resolution in transillumination using collimated light.

    abstract::In traditional transillumination of the breast (diaphanography), the abundance of diffuse light resulting from the use of extended noncollimated sources reduces the visibility of deep seated lesions. A prototype scanning imaging system has been developed to investigate the effectiveness of thin collimated light beams ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.251126

    authors: Wist AO,Fatouros PP,Herr SL

    更新日期:1993-01-01 00:00:00

  • The problem of scatter correction in positron volume imaging.

    abstract::Thin, dense interslice septa have long been used to reduce the scattered radiation collected in positron emission tomography (PET). These septa prevent the acquisition of coincident gamma rays that are oblique to the scanning planes. Several volume imaging systems that acquire oblique rays have been built. The reasons...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.222675

    authors: Thompson CJ

    更新日期:1993-01-01 00:00:00

  • Measurement of mean and variance of velocity fields within each voxel by NMR imaging.

    abstract::If a flow field exists within an object that is being imaged, there could be a velocity spectrum in each voxel due to the finite voxel size. Consequently, the mean value and the variance of velocity in each voxel can be defined and used to describe the velocity spectrum. An NMR (nuclear magnetic resonance) imaging tec...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.14520

    authors: Xiang QS,Nalcioglu O

    更新日期:1988-01-01 00:00:00

  • Algebraic reconstruction for magnetic resonance imaging under B0 inhomogeneity.

    abstract::In magnetic resonance imaging, spatial localization is usually achieved using Fourier encoding which is realized by applying a magnetic field gradient along the dimension of interest to create a linear correspondence between the resonance frequency and spatial location following the Larmor equation. In the presence of...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.712126

    authors: Kadah YM,Hu X

    更新日期:1998-06-01 00:00:00

  • Multifrequency electrical impedance tomography using spectral constraints.

    abstract::Multifrequency electrical impedance tomography (MFEIT) exploits the dependence of tissue impedance on frequency to recover an image of conductivity. MFEIT could provide emergency diagnosis of pathologies such as acute stroke, brain injury and breast cancer. We present a method for performing MFEIT using spectral const...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2284966

    authors: Malone E,Sato Dos Santos G,Holder D,Arridge S

    更新日期:2014-02-01 00:00:00

  • The effect of image distortion on 3-D reconstruction of coronary bypass grafts from angiographic views.

    abstract::Three-dimensional (3-D) reconstructions of coronary bypass grafts performed from X-ray angiographic images may become increasingly important for the investigation of damaging mechanical stresses imposed to these vessels by the cyclic movement of the heart. Contrary to what we had experienced with coronary arteries, ap...

    journal_title:IEEE transactions on medical imaging

    pub_type: 信件

    doi:10.1109/42.875203

    authors: Dorsaz PA,Dorsaz L,Doriot PA

    更新日期:2000-07-01 00:00:00

  • Restoration of retinal images obtained through cataracts.

    abstract::An optical model for imaging the retina through cataracts has been developed. The images are treated as sample functions of stochastic processes. On the basis of the model a homomorphic Weiner filter can be designed that will optimally restore the cataractous image (in the mean-square-error sense). The design of the f...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.41493

    authors: Peli E,Peli T

    更新日期:1989-01-01 00:00:00

  • A hardware architecture using finite-field arithmetic for computing maximum-likelihood estimates in emission tomography.

    abstract::A special-purpose hardware architecture is proposed to implement the expectation-maximization algorithm to compute, in clinically useful times, the maximum-likelihood estimate of a radionuclide distribution for a positron-emission tomogram from time-of-flight measurements. Two-dimensional convolutions required for for...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.14510

    authors: Klotz HR,Snyder DL

    更新日期:1988-01-01 00:00:00

  • Efficient Compressed Sensing SENSE pMRI Reconstruction With Joint Sparsity Promotion.

    abstract::The theory and techniques of compressed sensing (CS) have shown their potential as a breakthrough in accelerating k-space data acquisition for parallel magnetic resonance imaging (pMRI). However, the performance of CS reconstruction models in pMRI has not been fully maximized, and CS recovery guarantees for pMRI are l...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2474383

    authors: Chun IY,Adcock B,Talavage TM

    更新日期:2016-01-01 00:00:00

  • Direct Parametric Reconstruction Using Anatomical Regularization for Simultaneous PET/MRI Data.

    abstract::Pharmacokinetic analysis of dynamic positron emission tomography (PET) imaging data maps the measured time activity curves to a set of model-specific pharmacokinetic parameters. Voxel-based parameter estimation via curve fitting is conventionally performed indirectly on a sequence of independently reconstructed PET im...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2427777

    authors: Loeb R,Navab N,Ziegler SI

    更新日期:2015-11-01 00:00:00

  • Spherical Deformable U-Net: Application to Cortical Surface Parcellation and Development Prediction.

    abstract::Convolutional Neural Networks (CNNs) have achieved overwhelming success in learning-related problems for 2D/3D images in the Euclidean space. However, unlike in the Euclidean space, the shapes of many structures in medical imaging have an inherent spherical topology in a manifold space, e.g., the convoluted brain cort...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2021.3050072

    authors: Zhao F,Wu Z,Wang L,Lin W,Gilmore JH,Xia S,Shen D,Li G

    更新日期:2021-01-08 00:00:00

  • A Tensor B-Spline Approach for Solving the Diffusion PDE With Application to Optical Diffusion Tomography.

    abstract::Optical Diffusion Tomography (ODT) is a modern non-invasive medical imaging modality which requires mathematical modelling of near-infrared light propagation in tissue. Solving the ODT forward problem equation accurately and efficiently is crucial. Typically, the forward problem is represented by a Diffusion PDE and i...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2641500

    authors: Shulga D,Morozov O,Hunziker P

    更新日期:2017-04-01 00:00:00

  • Model-based MR parameter mapping with sparsity constraints: parameter estimation and performance bounds.

    abstract::Magnetic resonance parameter mapping (e.g., T1 mapping, T2 mapping, T*2 mapping) is a valuable tool for tissue characterization. However, its practical utility has been limited due to long data acquisition time. This paper addresses this problem with a new model-based parameter mapping method. The proposed method util...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2322815

    authors: Zhao B,Lam F,Liang ZP

    更新日期:2014-09-01 00:00:00

  • Simultaneous MR-compatible emission and transmission imaging for PET using time-of-flight information.

    abstract::Quantitative positron emission tomography (PET) imaging relies on accurate attenuation correction. Predicting attenuation values from magnetic resonance (MR) images is difficult because MR signals are related to proton density and relaxation properties of tissues. Here, we propose a method to derive the attenuation ma...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2198831

    authors: Mollet P,Keereman V,Clementel E,Vandenberghe S

    更新日期:2012-09-01 00:00:00

  • Multistage hybrid active appearance model matching: segmentation of left and right ventricles in cardiac MR images.

    abstract::A fully automated approach to segmentation of the left and right cardiac ventricles from magnetic resonance (MR) images is reported. A novel multistage hybrid appearance model methodology is presented in which a hybrid active shape model/active appearance model (AAM) stage helps avoid local minima of the matching func...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.925294

    authors: Mitchell SC,Lelieveldt BP,van der Geest RJ,Bosch HG,Reiber JH,Sonka M

    更新日期:2001-05-01 00:00:00

  • Unwarping of unidirectionally distorted EPI images.

    abstract::Echo-planar imaging (EPI) is a fast nuclear magnetic resonance imaging (MRI) method. Unfortunately, local magnetic field inhomogeneities induced mainly by the subject's presence cause significant geometrical distortion, predominantly along the phase-encoding direction, which must be undone to allow for meaningful furt...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.836368

    authors: Kybic J,Thévenaz P,Nirkko A,Unser M

    更新日期:2000-02-01 00:00:00

  • Automatic segmentation of scaling in 2-D psoriasis skin images.

    abstract::Psoriasis is a chronic inflammatory skin disease that affects over 3% of the population. Various methods are currently used to evaluate psoriasis severity and to monitor therapeutic response. The PASI system of scoring is widely used for evaluating psoriasis severity. It employs a visual analogue scale to score the th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2236349

    authors: Lu J,Kazmierczak E,Manton JH,Sinclair R

    更新日期:2013-04-01 00:00:00

  • Seamless Lesion Insertion for Data Augmentation in CAD Training.

    abstract::The performance of a classifier is largely dependent on the size and representativeness of data used for its training. In circumstances where accumulation and/or labeling of training samples is difficult or expensive, such as medical applications, data augmentation can potentially be used to alleviate the limitations ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2640180

    authors: Pezeshk A,Petrick N,Weijie Chen,Sahiner B

    更新日期:2017-04-01 00:00:00

  • Local phase tensor features for 3-D ultrasound to statistical shape+pose spine model registration.

    abstract::Most conventional spine interventions are performed under X-ray fluoroscopy guidance. In recent years, there has been a growing interest to develop nonionizing imaging alternatives to guide these procedures. Ultrasound guidance has emerged as a leading alternative. However, a challenging problem is automatic identific...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2332571

    authors: Hacihaliloglu I,Rasoulian A,Rohling RN,Abolmaesumi P

    更新日期:2014-11-01 00:00:00

  • Robust Unmixing of Dynamic Sequences Using Regions of Interest.

    abstract::In dynamic planar imaging, extraction of signals specific to structures is complicated by structures superposition. Due to overlapping, signals extraction with classic regions of interest (ROIs) methods suffers from inaccuracy, as extracted signals are a mixture of targeted signals. Partial volume effect raises the sa...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2759661

    authors: Filippi M,Desvignes M,Moisan E

    更新日期:2018-01-01 00:00:00

  • Computer-assisted scan protocol and reconstruction (CASPAR)-reduction of image noise and patient dose.

    abstract::X-ray computed tomography is a powerful medical imaging device. It allows high-resolution 3-D visualization of the human body. However, one drawback is the health risk associated with ionizing radiation. Simply downscaling the radiation intensities over the entire scan results in increased quantum noise. This paper pr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2034515

    authors: Sperl J,Beque D,Claus B,De Man B,Senzig B,Brokate M

    更新日期:2010-03-01 00:00:00

  • Ultrafast Ultrasound Imaging Using Combined Transmissions With Cross-Coherence-Based Reconstruction.

    abstract::Plane-wave-based ultrafast imaging has become the prevalent technique for non-conventional ultrasound imaging. The image quality, especially in terms of the suppression of artifacts, is generally compromised by reducing the number of transmissions for a higher frame rate. We hereby propose a new ultrafast imaging fram...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2736423

    authors: Zhang Y,Guo Y,Lee WN

    更新日期:2018-02-01 00:00:00