An isolated fourth ventricle in neurosarcoidosis: MRI findings.

Abstract:

:We report on an isolated enlargement of the fourth ventricle in a patient with neurosarcoidosis which developed 3 years after the insertion of a ventriculo-atrial shunt. Repeated MRI images were obtained in a patient with known neurosarcoidosis between 1995 and 2000. Imaging findings were correlated to the medical course of the patient, who developed a hydrocephalus and a trapped fourth ventricle consecutively. The isolation was presumably due to granulomatous inflammation of the ependyma surrounding the fourth ventricular outlets. The isolated fourth ventricle was responsible for a deterioration of neurological status. Neurosarcoidosis is a severe complication in sarcoidosis patients. An isolated enlargement of the fourth ventricle is a rare complication in clinically deteriorated patients with neurosarcoidosis and ventricular drainage, which may require neurosurgical treatment.

journal_name

Eur Radiol

journal_title

European radiology

authors

Hesselmann V,Wedekind C,Terstegge K,Schulte O,Voges J,Krug B,Lackner K

doi

10.1007/s00330-002-1369-3

subject

Has Abstract

pub_date

2002-12-01 00:00:00

pages

S1-3

eissn

0938-7994

issn

1432-1084

journal_volume

12 Suppl 3

pub_type

杂志文章
  • The added diagnostic value of 64-row multidetector CT combined with contrast-enhanced US in the evaluation of hepatocellular nodule vascularity: implications in the diagnosis of malignancy in patients with liver cirrhosis.

    abstract::The aim of this study was to assess the added diagnostic value of contrast-enhanced US (CEUS) combined with 64-row multidetector CT (CT) in the assessment of hepatocellular nodule vascularity in patients with liver cirrhosis. One hundred and six cirrhotic patients (68 male, 38 female; mean age +/- SD, 70 +/- 7 years) ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-008-1179-3

    authors: Quaia E,Alaimo V,Baratella E,Medeot A,Midiri M,Cova MA

    更新日期:2009-03-01 00:00:00

  • Non-invasive quantification of pancreatic exocrine function using secretin-stimulated MRCP.

    abstract::Our objective was to quantify water volume using magnetic resonance cholangiopancreatography (MRCP) sequences and apply this to secretin-stimulated studies with the aim of quantifying pancreatic exocrine function. A commercially available single-shot MRCP sequence was used in conjunction with a body phased-array coil ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1605-x

    authors: Punwani S,Gillams AR,Lees WR

    更新日期:2003-02-01 00:00:00

  • Breath-hold MR imaging of focal liver lesions: comparison of fast and ultrasound techniques.

    abstract::The performance of breath-hold MR imaging using two T2-weighted hybrid sequences (TSE, TGSE), two T2-weighted single-shot sequences (HASTE, EPI-SE), and one T1-weighted gradient-echo sequence (FLASH) was compared with a standard conventional T2-weighted SE sequence in 20 patients with focal liver lesions. Liver signal...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/BF00240685

    authors: Gaa J,Fischer H,Laub G,Georgi M

    更新日期:1996-01-01 00:00:00

  • Recurrent peripheral vestibulopathy: Is MRI useful for the diagnosis of endolymphatic hydrops in clinical practice?

    abstract:OBJECTIVES:Recurrent peripheral vestibulopathy (RPV) is a public health problem, yet the aetiology remains unclear. Recent developments in MRI of endolymphatic hydrops (EH) allow for a better understanding of inner ear disorders. We intended to study the prevalence of EH in patients with RPV, in comparison to those wit...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-3712-5

    authors: Attyé A,Dumas G,Troprès I,Roustit M,Karkas A,Banciu E,Pietras J,Lamalle L,Schmerber S,Krainik A

    更新日期:2015-10-01 00:00:00

  • Assessment and treatment planning of lateral intracranial dural arteriovenous fistulas in 3 T MRI and DSA: A detailed analysis under consideration of time-resolved imaging of contrast kinetics (TRICKS) and ce-MRA sequences.

    abstract:OBJECTIVES:The current gold standard in the assessment of lateral intracranial dural arteriovenous fistulas (LDAVF) is digital subtraction angiography (DSA). However, magnetic resonance imaging (MRI) is a non-invasive emerging tool for the evaluation of such lesions. The aim of our study was to compare the DSA to our 3...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4335-1

    authors: Ertl L,Brückmann H,Kunz M,Patzig M,Brem C,Forbrig R,Fesl G

    更新日期:2016-12-01 00:00:00

  • Clinically significant skeletal variations of the shoulder and the wrist: role of MR imaging.

    abstract::Several skeletal variations of the upper extremity may cause painful conditions or precipitate early degenerative changes, either spontaneously or in response to overuse and trauma. Magnetic resonance imaging has proved particularly useful for accurate interpretation of many of these clinically significant skeletal va...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1660-3

    authors: Mellado JM,Calmet J,Domènech S,Saurí A

    更新日期:2003-07-01 00:00:00

  • Mangan-enhanced MR imaging for the detection and localisation of small pancreatic insulinoma.

    abstract::Insulinoma is the most common pancreatic endocrine tumor. Localization of small tumors remains a diagnostic challenge. Recently, Mangafodipir-enhanced MR imaging using a whole-body coil has been shown to be effective in the detection and staging of pancreatic cancer [3]. Localization of even small tumors is improved a...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-003-2017-2

    authors: Hamoud AK,Khan MF,Aboalmaali N,Usadel KH,Wullstein C,Vogl TJ

    更新日期:2004-05-01 00:00:00

  • Impact of sublingual nitroglycerin dosage on FFRCT assessment and coronary luminal volume-to-myocardial mass ratio.

    abstract:OBJECTIVES:Fractional flow reserve computed tomography (FFRCT) depends upon nitroglycerin (NTG) inducing maximal hyperemia. However, the impact of NTG dosages on FFRCT analysis including coronary volume-to-mass ratio (V/M) is unknown. METHODS:Eighty patients with repeat coronary CT angiograms (CCTAs) with different su...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06293-7

    authors: Holmes KR,Fonte TA,Weir-McCall J,Anastasius M,Blanke P,Payne GW,Ellis J,Murphy DT,Taylor C,Leipsic JA,Sellers SL

    更新日期:2019-12-01 00:00:00

  • Gadoxetic acid-enhanced MR imaging for hepatocellular carcinoma: molecular and genetic background.

    abstract::Gadoxetic acid-enhanced magnetic resonance imaging (MRI) plays important roles in diagnosis of hepatic lesions because of its superiority in the detectability of small lesions, its differentiation ability, and its utility for the early diagnosis of hepatocellular carcinoma (HCC). In HCC, expression of organic anion tr...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-020-06687-y

    authors: Kitao A,Matsui O,Yoneda N,Kozaka K,Kobayashi S,Koda W,Inoue D,Ogi T,Yoshida K,Gabata T

    更新日期:2020-06-01 00:00:00

  • MR liver imaging with Gd-EOB-DTPA: a delay time of 10 minutes is sufficient for lesion characterisation.

    abstract:OBJECTIVES:To assess whether, in patients with normal liver function, a hepatobiliary delay time of 10 min after Gd-EOB-DTPA injection is sufficient for lesion characterisation. METHODS:In 42 consecutive patients with suspected focal liver lesions, dynamic MRI was performed after intravenous Gd-EOB-DTPA, followed by h...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2486-2

    authors: van Kessel CS,Veldhuis WB,van den Bosch MA,van Leeuwen MS

    更新日期:2012-10-01 00:00:00

  • Radiological features of the visceral and skeletal involvement of hemochromatosis.

    abstract::Hemochromatosis is a multisystem disorder produced by the excessive accumulation of iron in visceral organs and the musculoskeletal system. Clinically the disease may be silent, but characteristic radiological features may point to the diagnosis. The increased iron stores in the organs involved, especially in the live...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050274

    authors: Jäger HJ,Mehring U,Götz GF,Neise M,Erlemann R,Kapp HJ,Mathias KD

    更新日期:1997-01-01 00:00:00

  • Detection and characterisation of liver metastases.

    abstract::Modern liver imaging of cancer patients requires an imaging modality that is not only highly sensitive in detecting lesions but also provides reliable characterisation of lesions and thus allows differentiation of metastases from frequently found benign lesions. Conventional ultrasound (US) has a relatively poor sensi...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s10406-004-0088-z

    authors: Albrecht T,Hohmann J,Oldenburg A,Skrok J,Wolf KJ

    更新日期:2004-10-01 00:00:00

  • MR-guided vacuum-assisted breast biopsy of MRI-only lesions: a single center experience.

    abstract:PURPOSE:The purpose of this study was to compare three different biopsy devices on false-negative and underestimation rates in MR-guided, vacuum-assisted breast biopsy (VABB) of MRI-only lesions. METHODS:This retrospective, single-center study was IRB-approved. Informed consent was waived. 467 consecutive patients und...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4267-9

    authors: Spick C,Schernthaner M,Pinker K,Kapetas P,Bernathova M,Polanec SH,Bickel H,Wengert GJ,Rudas M,Helbich TH,Baltzer PA

    更新日期:2016-11-01 00:00:00

  • Magnification survey and spot view mammography with a new microfocus X-ray unit: detail resolution and radiation exposure.

    abstract::The aim of our study was to evaluate a mammography unit capable of magnification of up to fourfold at an equivalent or lower dose than with current systems. A prototype mammography tube with an electron-beam-focusing technology resulting in a focal spot size of 40-120 micro m was combined with a highly intensifying sc...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050399

    authors: Funke M,Breiter N,Hermann K,Oestmann J,Grabbe E

    更新日期:1998-01-01 00:00:00

  • Diagnostic values of 68Ga-labelled DOTANOC PET/CT imaging in pediatric patients presenting with paraneoplastic opsoclonus myoclonus ataxia syndrome.

    abstract:OBJECTIVES:Opsoclonus myoclonus ataxia (OMA) syndrome, also known as "Kinsbourne syndrome" or "dancing eye syndrome," is a rare, paraneoplastic entity which may be associated with pediatric neuroblastic tumors and carry a grave prognosis. We aimed to evaluate the role of 68Ga DOTANOC PET/CT for detecting neuroblastic t...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07587-x

    authors: Kumar R,Vankadari K,Mittal BR,Bansal D,Trehan A,Sahu JK,Sankhyan N

    更新日期:2021-01-06 00:00:00

  • Prostate cancer detection among readers with different degree of experience using ultra-high b-value diffusion-weighted Imaging: Is a non-contrast protocol sufficient to detect significant cancer?

    abstract:AIM:To evaluate the accuracy of a T2-weighted (T2w) - and a parallel transmit zoomed b = 2000 s/mm2 (b2000) - diffusion-weighted imaging sequence among three readers with different degrees of experience for prostate cancer (Pca) detection. METHODS:Ninety-three patients with suspected Pca were enrolled. For b2000 a two...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-5004-8

    authors: Hausmann D,Aksöz N,von Hardenberg J,Martini T,Westhoff N,Buettner S,Schoenberg SO,Riffel P

    更新日期:2018-02-01 00:00:00

  • Magnetic resonance imaging with diffusion-weighted imaging in the evaluation of thyroid-associated orbitopathy: getting below the tip of the iceberg.

    abstract:OBJECTIVES:To compare extraocular muscles (EOMs) T2, post-contrast T1 (T1Gad) signal intensity ratios (SIRs) and normalized-apparent diffusion coefficient (n-ADC) values in patients with thyroid-associated orbitopathy (TAO) at different phases of activity and severity and correlate MRI modifications to clinical evoluti...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3103-3

    authors: Politi LS,Godi C,Cammarata G,Ambrosi A,Iadanza A,Lanzi R,Falini A,Bianchi Marzoli S

    更新日期:2014-05-01 00:00:00

  • Tuberculous epididymitis associated with abdominal lymphadenopathy (2004:1b).

    abstract::Although the predominant form of tuberculosis is pulmonary disease, an increasing number of cases with extra-pulmonary involvement have been reported. The diagnosis of extra-pulmonary tuberculosis is often difficult because of its protean clinical manifestations and non-specific laboratory findings. Abdominal lymph no...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-003-1943-3

    authors: De Backer AI,Mortelé KJ,De Roeck J,Ros PR,De Keulenaer BL,Vanschoubroeck IJ,Bomans P

    更新日期:2004-04-01 00:00:00

  • Reproducibility of linear tumor measurements using PACS: comparison of caliper method with edge-tracing method.

    abstract::The aim of this study was to evaluate inter- and intra-observer reproducibility when making electronic caliper linear tumor measurements on picture archiving and communications systems (PACS) and compare them with linear measurements obtained from circumferential tracing of tumor perimeter. Three radiologists measured...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-003-2027-0

    authors: Monsky WL,Raptopoulos V,Keogan MT,Doty D,Kamel I,Yam CS,Ransil BJ

    更新日期:2004-03-01 00:00:00

  • Multislice spiral CT angiography in peripheral arterial occlusive disease: a valuable tool in detecting significant arterial lumen narrowing?

    abstract::The aim of this study was to evaluate the potential of multislice CT angiography (CTA) in detecting hemodynamically significant (> or =70%) lesions of lower extremity inflow and runoff arteries. Fifty patients (42 men, 8 women; mean age 68 years) with peripheral arterial occlusive disease underwent multislice spiral C...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-004-2289-1

    authors: Portugaller HR,Schoellnast H,Hausegger KA,Tiesenhausen K,Amann W,Berghold A

    更新日期:2004-09-01 00:00:00

  • Multiple pulmonary artery pseudoaneurysms: intrasaccular embolization.

    abstract::We report the case of a 32-year-old female presenting with two pulmonary artery false aneurysms of mycotic origin. Considering the natural history and potential complications, we treated the patient by intrasaccular embolization with steel coils. No complication occurred. ...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s003300050130

    authors: Ghaye B,Trotteur G,Dondelinger RF

    更新日期:1997-01-01 00:00:00

  • The effect of four-phasic versus three-phasic contrast media injection protocols on extravasation rate in coronary CT angiography: a randomized controlled trial.

    abstract:OBJECTIVES:Contrast media (CM) extravasation is a well-known complication of CT angiography (CTA). Our prospective randomized control study aimed to assess whether a four-phasic CM administration protocol reduces the risk of extravasation compared to the routinely used three-phasic protocol in coronary CTA. METHODS:Pa...

    journal_title:European radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s00330-017-4866-0

    authors: Karády J,Panajotu A,Kolossváry M,Szilveszter B,Jermendy ÁL,Bartykowszki A,Károlyi M,Celeng C,Merkely B,Maurovich-Horvat P

    更新日期:2017-11-01 00:00:00

  • Accuracy of helical CT for acute pulmonary embolism: ROC analysis of observer performance related to clinical experience.

    abstract::The aim of this study was to test the influence of observer experience on the accuracy for interpreting helical CT for acute pulmonary embolism (PE) and to identify sources of observer errors. Three observers of different expertise blindly assessed 147 helical CT scans for suspected PE (true status regarding absence o...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050526

    authors: van Rossum AB,van Erkel AR,van Persijn van Meerten EL,Ton ER,Rebergen SA,Pattynama PM

    更新日期:1998-01-01 00:00:00

  • Imaging of aortic dissection by helical computed tomography (CT).

    abstract::Aortic dissection is the most frequent cause of aortic emergency, and its outcome is still frequently fatal. The management of this pathology has changed with the development of endovascular means. Nowadays, imaging modalities are helpful in management decision-making by providing information such as identification of...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-004-2441-y

    authors: Willoteaux S,Lions C,Gaxotte V,Negaiwi Z,Beregi JP

    更新日期:2004-11-01 00:00:00

  • Meta-analysis: adjusted indirect comparison of drug-eluting bead transarterial chemoembolization versus 90Y-radioembolization for hepatocellular carcinoma.

    abstract:OBJECTIVE:To investigate comparative effectiveness of drug-eluting bead transarterial chemoembolization (DEB-TACE) versus Yttrium-90 (90Y)-radioembolization for hepatocellular carcinoma (HCC). METHODS:Studies comparing conventional (c)TACE versus 90Y-radioembolization or DEB-TACE for HCC treatment were identified usin...

    journal_title:European radiology

    pub_type: 杂志文章,meta分析

    doi:10.1007/s00330-016-4548-3

    authors: Ludwig JM,Zhang D,Xing M,Kim HS

    更新日期:2017-05-01 00:00:00

  • MRI and CT revealing carcinoid heart disease.

    abstract::Carcinoid heart disease is a frequent complication of the carcinoid syndrome, usually presenting as right-sided valvular heart disease. Although the diagnosis is most often made with cardiac ultrasound, MRI and CT are valuable techniques for diagnosing carcinoid heart disease. ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:

    authors: Mollet NR,Dymarkowski S,Bogaert J

    更新日期:2003-12-01 00:00:00

  • Invasive interval cancers in the Ostergötland Mammographic Screening Programme: radiological analysis.

    abstract::The aim of this study was to find out by radiological analysis whether it is possible to prevent interval cancers in screening programmes without a concomitant increase in false positives. Re-scrutiny of all mammograms of 544 interval cancers was implemented. Blinded re-scrutiny of screening mammograms of 390 interval...

    journal_title:European radiology

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1007/s003300050452

    authors: Vitak B

    更新日期:1998-01-01 00:00:00

  • Improvement of post-gadolinium contrast with magnetization transfer.

    abstract::Magnetization transfer (MT) provides post-gadolinium contrast improvement through decreasing the tissue signal. Our study had two aims: to analyse the effect of MT qualitatively and quantitatively in 13 patients, and to analyse in vitro the competition between two relaxation phenomena, dipole-dipole which is character...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/pl00006889

    authors: Huot P,Dousset V,Hatier F,Degreze P,Carlier P,Caillé JM

    更新日期:1997-01-01 00:00:00

  • Correction to: T1 and T2 MR fingerprinting measurements of prostate cancer and prostatitis correlate with deep learning-derived estimates of epithelium, lumen, and stromal composition on corresponding whole mount histopathology.

    abstract::The original version of this article, published on 02 September 2020, unfortunately contained a mistake. ...

    journal_title:European radiology

    pub_type: 已发布勘误

    doi:10.1007/s00330-020-07285-8

    authors: Shiradkar R,Panda A,Leo P,Janowczyk A,Farre X,Janaki N,Li L,Pahwa S,Mahran A,Buzzy C,Fu P,Elliott R,MacLennan G,Ponsky L,Gulani V,Madabhushi A

    更新日期:2020-09-18 00:00:00

  • Development of pumping emulsification device with glass membrane to form ideal lipiodol emulsion in transarterial chemoembolization.

    abstract:PURPOSE:To evaluate a pumping emulsification device that can improve the physiochemical properties and stability of lipiodol emulsion for conventional transarterial chemoembolization. MATERIALS AND METHODS:A pumping emulsification device constructed of a glass membrane with a hydrophobic surface with pore size of 50 μ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-5197-x

    authors: Tanaka T,Masada T,Nishiofuku H,Fukuoka Y,Sato T,Tatsumoto S,Marugami N,Higashi S,Kichikawa K

    更新日期:2018-05-01 00:00:00