Late aneurysm formation in a femoro-popliteal polytetrafluoroethylene graft.

Abstract:

:Since improvement in the material, true aneurysms and pseudoaneurysm formations have become relatively rare complications after femoro-popliteal reconstruction with polytetrafluoroethylene (PTFE) grafts. We report a case of late graft rupture and pseudoaneurysm formation within the straight femoral part of a femoro-popliteal bypass with reinforced (PTFE-wrapped) Gore-Tex graft. The rupture occurred 7 years after implantation without history of direct traumatization. Intraoperatively the whole bypass showed macro- and microscopically visible deterioration of the wall with almost complete disruption at the site of the aneurysm. The graft had to be replaced completely. In conclusion, we recommend continuous long-term follow-up of these patients preferably with duplex ultrasonography.

journal_name

Eur Radiol

journal_title

European radiology

authors

Biederer J,Müller-Hülsbeck S,Loose JR,Heller M

doi

10.1007/s003300050909

subject

Has Abstract

pub_date

1999-01-01 00:00:00

pages

1678-81

issue

8

eissn

0938-7994

issn

1432-1084

pii

90091678.330

journal_volume

9

pub_type

杂志文章
  • In vivo effects of bupivacaine and gadobutrol on the intervertebral disc following discoblock and discography: a histological analysis.

    abstract:OBJECTIVES:The aim of the present study was to histologically compare chondrotoxicity in surgically harvested intervertebral discs (IVDs) of patients following discoblock, discography, or no preoperative intervention. METHODS:Thirty patients (IVD degeneration Modic ≥ 2°, Pfirrmann 3° or 4°) at L4/5 or L5/S1 who were p...

    journal_title:European radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s00330-016-4358-7

    authors: Strube P,Pfitzner BM,Streitparth F,Hartwig T,Putzier M

    更新日期:2017-01-01 00:00:00

  • Prediction of infarction development after endovascular stroke therapy with dual-energy computed tomography.

    abstract:OBJECTIVES:After intraarterial recanalisation (IAR), the haemorrhage and the blood-brain barrier (BBB) disruption can be distinguished using dual-energy computed tomography (DECT). The aim of the present study was to investigate whether future infarction development can be predicted from DECT. METHODS:DECT scans of 20...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4412-5

    authors: Djurdjevic T,Rehwald R,Knoflach M,Matosevic B,Kiechl S,Gizewski ER,Glodny B,Grams AE

    更新日期:2017-03-01 00:00:00

  • Cell tracking using (19)F magnetic resonance imaging: technical aspects and challenges towards clinical applications.

    abstract::(19)F MRI is emerging as a new imaging technique for cell tracking. It is particularly attractive because of its potential for direct and precise cell quantification. The most important challenge towards in vivo applications is the sensitivity of the technique, i.e. the detection limit in a reasonable imaging time. Op...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3474-5

    authors: Amiri H,Srinivas M,Veltien A,van Uden MJ,de Vries IJ,Heerschap A

    更新日期:2015-03-01 00:00:00

  • The correlation of mammographic-and histologic patterns of breast cancers in BRCA1 gene mutation carriers, compared to age-matched sporadic controls.

    abstract::Breast cancers in BRCA1 gene mutation carriers often have specific histologic features: grade III tumors with pushing margins. Our purpose was to compare the mammographic and histologic features of breast cancers in carriers with those in age-matched sporadic controls. The features of breast cancers in 27 BRCA1 carrie...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-006-0385-0

    authors: Kaas R,Kroger R,Peterse JL,Hart AA,Muller SH

    更新日期:2006-12-01 00:00:00

  • Calcium scoring using virtual non-contrast images from a dual-layer spectral detector CT: comparison to true non-contrast data and evaluation of proportionality factor in a large patient collective.

    abstract:OBJECTIVE:Determination of coronary artery calcium scoring (CACS) in non-contrast computed tomography (CT) images has been shown to be an important prognostic factor in coronary artery disease (CAD). The objective of this study was to evaluate the accuracy of CACS from virtual non-contrast (VNC) imaging generated from ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07677-w

    authors: Gassert FG,Schacky CE,Müller-Leisse C,Gassert FT,Pahn G,Laugwitz KL,Makowski MR,Nadjiri J

    更新日期:2021-01-20 00:00:00

  • Sonographic findings in stress fractures of the lower limb: preliminary findings.

    abstract::Stress fractures are common injuries frequently overlooked on first radiographs, especially in the early course. The gold standard for accurate diagnosis is MRI and scintigraphy. We report six cases of stress fractures of the lower limb diagnosed with sonography and describe typical sonographic features. ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-004-2525-8

    authors: Bodner G,Stöckl B,Fierlinger A,Schocke M,Bernathova M

    更新日期:2005-02-01 00:00:00

  • Cardiac MRI in pulmonary artery hypertension: correlations between morphological and functional parameters and invasive measurements.

    abstract:OBJECTIVE:To compare cardiac MRI with right heart catheterisation in patients with pulmonary hypertension (PH) and to evaluate its ability to assess PH severity. MATERIALS AND METHODS:Forty patients were included. MRI included cine and phase-contrast sequences, study of ventricular function, cardiac cavity areas and r...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1664-3

    authors: Alunni JP,Degano B,Arnaud C,Tétu L,Blot-Soulétie N,Didier A,Otal P,Rousseau H,Chabbert V

    更新日期:2010-05-01 00:00:00

  • Early post-operative magnetic resonance imaging in glioblastoma: correlation among radiological findings and overall survival in 60 patients.

    abstract:OBJECTIVES:To evaluate early post-operative magnetic resonance (EPMR) as a prognostic tool after resection of glioblastoma. METHODS:Sixty EPMR examinations were evaluated for perioperative infarct, tumour growth between diagnosis and EPMR, contrast enhancement pattern, and extent of resection (EOR). The EOR was approa...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-3914-x

    authors: Majós C,Cos M,Castañer S,Gil M,Plans G,Lucas A,Bruna J,Aguilera C

    更新日期:2016-04-01 00:00:00

  • A New Model for MR Evaluation of Liver Function with Gadoxetic Acid, Including Both Uptake and Excretion.

    abstract:OBJECTIVES:Most existing models that are in use to model hepatic function through assessment of hepatic gadoxetic acid enhancement kinetics do not consider quantitative measures of gadoxetic excretion. We developed a model that allows a simultaneous quantitation of uptake and excretion of liver specific contrast agents...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5500-5

    authors: Truhn D,Kuhl CK,Ciritsis A,Barabasch A,Kraemer NA

    更新日期:2019-01-01 00:00:00

  • Coronary CT angiography: automatic cardiac-phase selection for image reconstruction.

    abstract::We evaluated an algorithm for automatic selection of the cardiac phase with the least motion for image reconstruction at coronary computed tomography (CT) angiography (CCTA). We analyzed data of 100 patients (49 female, mean age 59 years) who had undergone retrospectively ECG-gated CCTA. Two experienced observers visu...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1368-8

    authors: Ruzsics B,Gebregziabher M,Lee H,Brothers RL,Allmendinger T,Vogt S,Costello P,Schoepf UJ

    更新日期:2009-08-01 00:00:00

  • Comparison between automated breast volume scanner (ABVS) versus hand-held ultrasound as a second look procedure after magnetic resonance imaging.

    abstract:OBJECTIVES:To evaluate the agreement between automated breast volume scanner (ABVS) and conventional ultrasound (US) as a second-look (SL) tool for assessing additional findings found on MRI. METHODS:Over a 7-month period, we prospectively assigned to SL-US and SL-ABVS all patients undergoing 1.5 T breast MRI in whom ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-4749-4

    authors: Girometti R,Zanotel M,Londero V,Bazzocchi M,Zuiani C

    更新日期:2017-09-01 00:00:00

  • Magnetic resonance imaging of knee injuries in children.

    abstract::The appearances of knee injuries on MR imaging are less well documented in children than adults. Some patterns of injury are shared by both groups of patients, e. g. meniscal damage. The frequency of specific injuries may differ, e. g. anterior cruciate ligament (ACL) tear. Congenital abnormality, coexistent pathology...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s003300050284

    authors: King SJ

    更新日期:1997-01-01 00:00:00

  • Significant differences when using MDRD for GFR estimation compared to radionuclide measured clearance.

    abstract:OBJECTIVES:To evaluate Estimated Glomerular Filtration Rate (eGFR), using the Modification of Diet in Renal Disease equation, and compare with radionuclide GFR (rGFR) in a Radiology setting to assess renal function prior to contrast administration. METHODS:Five hundred and sixteen retrospective rGFR studies from a mix...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-011-2157-8

    authors: Craig AJ,Britten A,Heenan SD,Irwin AG

    更新日期:2011-10-01 00:00:00

  • Polyp measurement based on CT colonography and colonoscopy: variability and systematic differences.

    abstract:OBJECTIVE:To assess the variability and systematic differences in polyp measurements on optical colonoscopy and CT colonography. MATERIALS:Gastroenterologists measured 51 polyps by visual estimation, forceps comparison and linear probe. CT colonography observers randomly assessed polyp size two-dimensionally (abdomina...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1683-0

    authors: de Vries AH,Bipat S,Dekker E,Liedenbaum MH,Florie J,Fockens P,van der Kraan R,Mathus-Vliegen EM,Reitsma JB,Truyen R,Vos FM,Zwinderman AH,Stoker J

    更新日期:2010-06-01 00:00:00

  • Comparison of high-resolution computed tomography findings between Pseudomonas aeruginosa pneumonia and Cytomegalovirus pneumonia.

    abstract:OBJECTIVE:To compare pulmonary high-resolution CT (HRCT) findings in patients with Pseudomonas aeruginosa pneumonia to HRCT findings in patients with Cytomegalovirus (CMV) pneumonia. METHODS:We studied 124 patients (77 men, 47 women; age range, 20-89 years; mean age, 65.4 years) with P. aeruginosa pneumonia and 44 pat...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3326-3

    authors: Omeri AK,Okada F,Takata S,Ono A,Nakayama T,Ando Y,Sato H,Hiramatsu K,Mori H

    更新日期:2014-12-01 00:00:00

  • Automated two-point dixon screening for the evaluation of hepatic steatosis and siderosis: comparison with R2-relaxometry and chemical shift-based sequences.

    abstract:OBJECTIVES:To evaluate the automated two-point Dixon screening sequence for the detection and estimated quantification of hepatic iron and fat compared with standard sequences as a reference. METHODS:One hundred and two patients with suspected diffuse liver disease were included in this prospective study. The followin...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3528-8

    authors: Henninger B,Zoller H,Rauch S,Schocke M,Kannengiesser S,Zhong X,Reiter G,Jaschke W,Kremser C

    更新日期:2015-05-01 00:00:00

  • Using an electrode as a lever to increase the distance between renal cell carcinoma and bowel during CT-guided radiofrequency ablation.

    abstract::The technique of using an electrode as a lever to increase the distance between renal cell carcinoma (RCC) and bowel during CT-guided radiofrequency ablation (RFA) is described. CT-guided percutaneous RFA was performed in two patients with two RCCs, which were in close proximity to the adjacent bowel. A sterile drape ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-007-0816-6

    authors: Park BK,Kim CK

    更新日期:2008-04-01 00:00:00

  • A simple classification system (the Tree flowchart) for breast MRI can reduce the number of unnecessary biopsies in MRI-only lesions.

    abstract:OBJECTIVES:To assess whether using the Tree flowchart obviates unnecessary magnetic resonance imaging (MRI)-guided biopsies in breast lesions only visible on MRI. METHODS:This retrospective IRB-approved study evaluated consecutive suspicious (BI-RADS 4) breast lesions only visible on MRI that were referred to our inst...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-4755-6

    authors: Woitek R,Spick C,Schernthaner M,Rudas M,Kapetas P,Bernathova M,Furtner J,Pinker K,Helbich TH,Baltzer PAT

    更新日期:2017-09-01 00:00:00

  • In vivo dentate nucleus MRI relaxometry correlates with previous administration of Gadolinium-based contrast agents.

    abstract:OBJECTIVES:To evaluate changes in T1 and T2* relaxometry of dentate nuclei (DN) with respect to the number of previous administrations of Gadolinium-based contrast agents (GBCA). METHODS:In 74 relapsing-remitting multiple sclerosis (RR-MS) patients with variable disease duration (9.8±6.8 years) and severity (Expanded ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4245-2

    authors: Tedeschi E,Palma G,Canna A,Cocozza S,Russo C,Borrelli P,Lanzillo R,Angelini V,Postiglione E,Morra VB,Salvatore M,Brunetti A,Quarantelli M

    更新日期:2016-12-01 00:00:00

  • Abbreviated MRI for HCC surveillance: is it ready for clinical use?

    abstract:KEY POINTS:• Abbreviated MRI (AMRI) protocols consist of acquiring only a minimal number of MRI sequences for HCC surveillance with acceptable diagnostic performance compared to complete MRI.• AMRI protocol options include non-contrast AMRI, dynamic AMRI or hepatobiliary phase AMRI post gadoxetate injection.• The best ...

    journal_title:European radiology

    pub_type: 社论

    doi:10.1007/s00330-020-06904-8

    authors: Vietti Violi N,Taouli B

    更新日期:2020-08-01 00:00:00

  • Discrimination of benign from malignant hepatic lesions based on their T2-relaxation times calculated from moderately T2-weighted turbo SE sequence.

    abstract::The differentiation of hemangioma from other hepatic neoplasms using MRI usually relies on the evaluation of heavily T2-weighted images. The aim of this study was to assess the value of T2-relaxation times calculated from moderately T2-weighted turbo spin-echo (TSE) sequence in characterization of focal hepatic lesion...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1366-6

    authors: Cieszanowski A,Szeszkowski W,Golebiowski M,Bielecki DK,Grodzicki M,Pruszynski B

    更新日期:2002-09-01 00:00:00

  • Scan and contrast administration principles of MDCT.

    abstract::Because of its fast scan speed, multi-detector row CT (MDCT) imposes a challenge to optimization of contrast enhancement and scan timing. However, when this challenge is overcome with the use of precisely designed protocols, MDCT provides us with an opportunity to use contrast medium more efficiently and flexibly than...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s10406-005-0165-y

    authors: Bae KT,Heiken JP

    更新日期:2005-12-01 00:00:00

  • Local staging of endometrial carcinoma: role of multidetector CT.

    abstract::The purpose was to evaluate the accuracy of multidetector CT (MDCT) on a 16-row CT scanner in local staging of endometrial carcinoma and more specifically in the assessment of the depth of myometrial invasion and presence of cervical infiltration. This prospective study includes 21 women with newly diagnosed endometri...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-007-0839-z

    authors: Tsili AC,Tsampoulas C,Dalkalitsis N,Stefanou D,Paraskevaidis E,Efremidis SC

    更新日期:2008-05-01 00:00:00

  • CT colonography polyp matching: differences between experienced readers.

    abstract::The purpose of this study was to investigate if experienced readers differ when matching polyps shown by both CT colonography (CTC) and optical colonoscopy (OC) and to explore the reasons for discrepancy. Twenty-eight CTC cases with corresponding OC were presented to eight experienced CTC readers. Cases represented a ...

    journal_title:European radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s00330-009-1328-3

    authors: Liedenbaum MH,de Vries AH,Halligan S,Bossuyt PM,Dachman AH,Dekker E,Florie J,Gryspeerdt SS,Jensch S,Johnson CD,Laghi A,Taylor SA,Stoker J

    更新日期:2009-07-01 00:00:00

  • MRI findings in patients with severe trismus following radiotherapy for nasopharyngeal carcinoma.

    abstract::The aim of the study was to document MRI findings in masticator structures in patients with trismus developing after radiotherapy for nasopharyngeal carcinoma (NPC). MRI neck examinations were reviewed in 35 patients with marked trismus, defined as an interincisal gap of 25 mm or less, post-radiotherapy for NPC. Patie...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1445-z

    authors: Bhatia KS,King AD,Paunipagar BK,Abrigo J,Vlantis AC,Leung SF,Ahuja AT

    更新日期:2009-11-01 00:00:00

  • Intravoxel water diffusion heterogeneity MR imaging of nasopharyngeal carcinoma using stretched exponential diffusion model.

    abstract:PURPOSE:To determine the utility of stretched exponential diffusion model in characterisation of the water diffusion heterogeneity in different tumour stages of nasopharyngeal carcinoma (NPC). MATERIALS AND METHODS:Fifty patients with newly diagnosed NPC were prospectively recruited. Diffusion-weighted MR imaging was ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3535-9

    authors: Lai V,Lee VH,Lam KO,Sze HC,Chan Q,Khong PL

    更新日期:2015-06-01 00:00:00

  • Visual stimulation, 1H MR spectroscopy and fMRI of the human visual pathways.

    abstract::The purpose was to assess changes in lactate content and other brain metabolites under visual stimulation in optical chiasm, optic radiations and occipital cortex using multiple voxel MR spectroscopy (MRS). 1H chemical shift imaging (CSI) examinations of transverse planes centered to include the above structures were ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-004-2494-y

    authors: Boucard CC,Mostert JP,Cornelissen FW,De Keyser J,Oudkerk M,Sijens PE

    更新日期:2005-01-01 00:00:00

  • Holmium-166 poly(L-lactic acid) microsphere radioembolisation of the liver: technical aspects studied in a large animal model.

    abstract:OBJECTIVE:To assess the accuracy of a scout dose of holmium-166 poly(L-lactic acid) microspheres ((166)Ho-PLLA-MS) in predicting the distribution of a treatment dose of (166)Ho-PLLA-MS, using single photon emission tomography (SPECT). METHODS:A scout dose (60 mg) was injected into the hepatic artery of five pigs and S...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1613-1

    authors: Vente MA,de Wit TC,van den Bosch MA,Bult W,Seevinck PR,Zonnenberg BA,de Jong HW,Krijger GC,Bakker CJ,van het Schip AD,Nijsen JF

    更新日期:2010-04-01 00:00:00

  • Jejunal diverticulitis with localized perforation diagnosed by ultrasound: a case report.

    abstract::A rare case of a proximal jejunal diverticulitis is presented. The diagnosis was initially suggested by US and confirmed by CT. Ultrasound detected a hypoechoic irregular lesion continuous with the jejunum suggestive of the presence of diverticula. The presence of peridiverticular hyperechoic fat, associated with US s...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1414-2

    authors: Kelekis AD,Poletti PA

    更新日期:2002-12-01 00:00:00

  • Systolic prospectively ECG-triggered dual-source CT angiography for evaluation of the coronary arteries in heart transplant recipients.

    abstract:OBJECTIVES:To assess feasibility, image quality, and radiation dose of prospectively ECG-triggered coronary CT angiography (CTA) in orthotopic heart transplant (OHT) recipients. METHODS:47 consecutive OHT recipients (40 men, mean age 62.1 ± 10.9 years, mean heart rate 86.3 ± 14.4 bpm) underwent dual-source CTA to rule...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-011-2126-2

    authors: Bastarrika G,Broncano J,Arraiza M,Azcárate PM,Simon-Yarza I,Levy Praschker BG,Pueyo JC,Zubieta JL,Rabago G

    更新日期:2011-09-01 00:00:00