Abstract:
OBJECTIVES:To evaluate the automated two-point Dixon screening sequence for the detection and estimated quantification of hepatic iron and fat compared with standard sequences as a reference. METHODS:One hundred and two patients with suspected diffuse liver disease were included in this prospective study. The following MRI protocol was used: 3D-T1-weighted opposed- and in-phase gradient echo with two-point Dixon reconstruction and dual-ratio signal discrimination algorithm ("screening" sequence); fat-saturated, multi-gradient-echo sequence with 12 echoes; gradient-echo T1 FLASH opposed- and in-phase. Bland-Altman plots were generated and correlation coefficients were calculated to compare the sequences. RESULTS:The screening sequence diagnosed fat in 33, iron in 35 and a combination of both in 4 patients. Correlation between R2* values of the screening sequence and the standard relaxometry was excellent (r = 0.988). A slightly lower correlation (r = 0.978) was found between the fat fraction of the screening sequence and the standard sequence. Bland-Altman revealed systematically lower R2* values obtained from the screening sequence and higher fat fraction values obtained with the standard sequence with a rather high variability in agreement. CONCLUSIONS:The screening sequence is a promising method with fast diagnosis of the predominant liver disease. It is capable of estimating the amount of hepatic fat and iron comparable to standard methods. KEY POINTS:• MRI plays a major role in the clarification of diffuse liver disease. • The screening sequence was introduced for the assessment of diffuse liver disease. • It is a fast and automated algorithm for the evaluation of hepatic iron and fat. • It is capable of estimating the amount of hepatic fat and iron.
journal_name
Eur Radioljournal_title
European radiologyauthors
Henninger B,Zoller H,Rauch S,Schocke M,Kannengiesser S,Zhong X,Reiter G,Jaschke W,Kremser Cdoi
10.1007/s00330-014-3528-8subject
Has Abstractpub_date
2015-05-01 00:00:00pages
1356-65issue
5eissn
0938-7994issn
1432-1084journal_volume
25pub_type
杂志文章abstract:OBJECTIVES:We aimed at establishing the impact upon gadolinium administration on the conspicuity of active enhancing multiple sclerosis (MS) lesions using double inversion recovery (DIR) at 3T. METHODS:15 consecutive patients with MS (n=8) or a clinically isolated syndrome (n=7) underwent pre and post-contrast DIR in ...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-016-4416-1
更新日期:2017-02-01 00:00:00
abstract:OBJECTIVES:To assess whether extracellular volume (ECV) fraction with equilibrium contrast-enhanced multidetector computed tomography (MDCT) predicts outcomes for unresectable pancreatic adenocarcinoma patients treated with chemotherapy METHODS: Sixty-seven patients (42 men, 25 women; mean age, 67.5 years; range, 45-83...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-018-5570-4
更新日期:2019-01-01 00:00:00
abstract:OBJECTIVES:Vascular complications are one of the most common causes of early kidney transplant dysfunction. Contrast enhanced ultrasound increases sensitivity to vascular changes. The aim of this study was to assess the prevalence and size of vascular abnormalities in early renal transplants using 3D CEUS and the signi...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-017-4871-3
更新日期:2017-11-01 00:00:00
abstract::The original version of this article, published on 27 May 2019, unfortunately contained a mistake. The following correction has therefore been made in the original. ...
journal_title:European radiology
pub_type: 已发布勘误
doi:10.1007/s00330-019-06333-2
更新日期:2019-12-01 00:00:00
abstract::Bronchioloalveolar carcinoma (BAC) is a polymorphic lung cancer the incidence of which is rising. The presence of intratumoral radiolucencies is an important feature of bronchioloalveolar carcinoma. The aim of this study was to present pictorially the spectrum of intratumoral radiolucencies visible in BAC. In 57 BACs ...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s003300050627
更新日期:1999-01-01 00:00:00
abstract:OBJECTIVES:To evaluate factors associated with increased fluoroscopy time or the need for complex techniques at IVC filter retrieval. METHODS:This is a single-institution retrospective cohort study of 187 consecutive patients who underwent IVC filter retrieval. An analysis was performed on associations of patient fact...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-018-5766-7
更新日期:2019-04-01 00:00:00
abstract:OBJECTIVES:X-ray iodinated contrast media have been shown to generate contrast in MR images when used with the chemical exchange saturation transfer (CEST) approach. The aim of this study is to compare contrast enhancement (CE) capabilities and perfusion estimates between radiographic molecules and a Gd-based contrast ...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-016-4552-7
更新日期:2017-05-01 00:00:00
abstract:OBJECTIVE:To estimate thyroid doses and cancer risk for paediatric patients undergoing neck computed tomography (CT). METHODS:We used average CTDI(vol) (mGy) values from 75 paediatric neck CT examinations to estimate thyroid dose in a mathematical anthropomorphic phantom (ImPACT Patient CT Dosimetry Calculator). Patie...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-015-3590-x
更新日期:2015-07-01 00:00:00
abstract:OBJECTIVES:To evaluate the outcomes of re-exposure to low-osmolar iodinated contrast medium (LOCM) in patients with a history of moderate-to-severe hypersensitivity reaction (HSR). METHODS:We retrospectively evaluated a cohort comprising all subjects satisfying the following conditions at 11 centres: (1) experienced a...
journal_title:European radiology
pub_type: 杂志文章,多中心研究
doi:10.1007/s00330-016-4682-y
更新日期:2017-07-01 00:00:00
abstract::Although spatial resolution of current MR angiography is excellent, temporal resolution has remained unsatisfactory. We evaluated clinical applicability of 2D thick-slice, contrast-enhanced subtraction MR angiography (2D-MR digital subtraction angiography) with sub-second temporal resolution in cerebrovascular occlusi...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s003300000584
更新日期:2000-01-01 00:00:00
abstract::We report a case of neurilemoma arising from the renal capsule. Renal neurilemoma is an especially rare tumor, with only 15 cases previously reported. We attempted to correlate MR findings with microscopic components of the tumor. On T2-weighted images the solid part of the tumor was heterogeneous hyperintense. The MR...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s003300000767
更新日期:2001-01-01 00:00:00
abstract:OBJECTIVES:Comparison of bolus tracking with a fixed threshold versus a manual fast start for coronary CT angiography. METHODS:We retrospectively analysed 320-row coronary CT angiography of 50 patients with suspected or known coronary artery disease. Twenty-five examinations were initiated by a bolus tracking method (...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-014-3148-3
更新日期:2014-06-01 00:00:00
abstract:OBJECTIVES:To evaluate the effect of hybrid iterative reconstruction on qualitative and quantitative parameters at 256-slice cardiac CT. METHODS:Prospective cardiac CT images from 20 patients were analysed. Paired image sets were created using 3 reconstructions, i.e. filtered back projection (FBP) and moderate- and hi...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-011-2361-6
更新日期:2012-06-01 00:00:00
abstract:OBJECTIVES:To compare [(18)F]FDG PET/MRI with PET/CT for the assessment of bone lesions in oncologic patients. METHODS:This prospective study included 67 patients with solid tumours scheduled for PET/CT with [(18)F]FDG who also underwent a whole-body PET/MRI scan. The datasets (PET/CT, PET/MRI) were rated by two reade...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-014-3229-3
更新日期:2014-08-01 00:00:00
abstract::The lower the heart rate the better image quality in multislice computed tomography (MSCT) coronary angiography. We prospectively assessed the influence of heart rate on per-patient diagnostic accuracy and image quality of MSCT coronary angiography and compared adaptive multisegment and standard halfscan reconstructio...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-007-0685-z
更新日期:2007-11-01 00:00:00
abstract:OBJECTIVE:To investigate dual-energy CT of hypervascular liver lesions in patients with HCC. METHODS:Forty patients with hepatocellular carcinomas were investigated with abdominal dual-energy CT. In each patient unenhanced and contrast-enhanced imaging with arterial und portovenous delay were performed. Hypervascular ...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-010-1964-7
更新日期:2011-04-01 00:00:00
abstract:OBJECTIVE:To investigate potential relationships between diffusion kurtosis imaging (DKI)-derived parameters using whole-tumour volume histogram analysis and clinicopathological prognostic factors in patients with rectal adenocarcinoma. MATERIAL AND METHODS:79 consecutive patients who underwent MRI examination with re...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-017-5094-3
更新日期:2018-04-01 00:00:00
abstract:OBJECTIVES:Liver-specific MRI is a fast-growing field, with technological and protocol advancements providing more robust imaging and allowing a greater depth of information per examination. This article reports the evidence for, and expert thinking on, current challenges in liver-specific MRI, as discussed at the 7th ...
journal_title:European radiology
pub_type: 共识发展会议,杂志文章
doi:10.1007/s00330-015-3873-2
更新日期:2016-03-01 00:00:00
abstract:OBJECTIVES:The purpose of this study was to investigate the association of relaxation-compensated chemical exchange saturation transfer (CEST) MRI with overall survival (OS) and progression-free survival (PFS) in newly diagnosed high-grade glioma (HGG) patients. METHODS:Twenty-six patients with newly diagnosed high-gr...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-019-06066-2
更新日期:2019-09-01 00:00:00
abstract::The purpose was to evaluate the accuracy of multidetector CT (MDCT) on a 16-row CT scanner in local staging of endometrial carcinoma and more specifically in the assessment of the depth of myometrial invasion and presence of cervical infiltration. This prospective study includes 21 women with newly diagnosed endometri...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-007-0839-z
更新日期:2008-05-01 00:00:00
abstract::Preoperative MRI of the breasts has been proven to be the most sensitive imaging modality in the detection of multifocal or multicentric tumor manifestations as well as simultaneous contralateral breast cancer. The aim of the presented retrospective study was to evaluate the benefit of preoperative MRI for patients wi...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-004-2351-z
更新日期:2004-10-01 00:00:00
abstract::Modern imaging technologies visualize different aspects of disease in a non-invasive way. Considerable progress has been made in the fusion of images from different imaging modalities using software approaches. One goal of fusion software is to align anatomical and functional images and allow improved spatial localiza...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/s003300101007
更新日期:2001-01-01 00:00:00
abstract::Magnetic resonance angiography (MRA) has become an imaging modality which comprises various techniques based on two concepts: methods relying on the natural flow effects, the time-of-flight and phase-contrast technique, either in two- or three-dimensional acquisition mode, and the more recently developed contrast-enha...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/s003300050834
更新日期:1999-01-01 00:00:00
abstract:OBJECTIVES:To evaluate thread sign of biliary intraductal papillary mucinous neoplasm (B-IPMN) on magnetic resonance imaging (MRI). METHODS:Thread sign was defined as intraductal linear or curvilinear hypointense striations. Two radiologists independently evaluated the presence and location of thread sign on MR cholan...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-015-4158-5
更新日期:2016-09-01 00:00:00
abstract:OBJECTIVES:To investigate the dynamic changes in airways in response to methacholine and salbutamol inhalation and to correlate the xenon ventilation index on xenon-enhanced chest CTs in asthmatics. METHODS:Thirty-one non-smokers (6 normal, 25 asthmatics) underwent xenon-enhanced chest CT and pulmonary function tests....
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-012-2516-0
更新日期:2012-11-01 00:00:00
abstract::The aim of this study was to describe type and rate of complications in a series of patients with liver tumors treated by the radiofrequency (RF) expandable system. A total of 166 patients, 114 with hepatocellular carcinoma (HCC; 92 small HCC, 22 large) and 52 with liver metastasis, were treated by the percutaneous RF...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-003-1990-9
更新日期:2004-01-01 00:00:00
abstract:OBJECTIVES:To characterize interhemispheric functional and anatomical connectivity and their relationships with impulsive behaviour in codeine-containing cough syrup (CCS)-dependent male adolescents and young adults. METHODS:We compared volumes of corpus callosum (CC) and its five subregion and voxel-mirrored homotopi...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-016-4465-5
更新日期:2017-03-01 00:00:00
abstract::The purpose of this paper was to investigate the effect of radiologist experience and increasing exposure to CT colonography on reader performance. Three radiologists of differing general experience (consultant, research fellow, trainee) independently analysed 100 CT colonographic datasets. Readers had no prior experi...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-004-2262-z
更新日期:2004-06-01 00:00:00
abstract:OBJECTIVE:To assess the variability and systematic differences in polyp measurements on optical colonoscopy and CT colonography. MATERIALS:Gastroenterologists measured 51 polyps by visual estimation, forceps comparison and linear probe. CT colonography observers randomly assessed polyp size two-dimensionally (abdomina...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-009-1683-0
更新日期:2010-06-01 00:00:00
abstract::We report a case of a large renal tumour containing small amounts of fat and some calcification that proved to be a renal cell carcinoma. The CT appearance of the tumour was suggestive of an angiomyolipoma. Although the overwhelming majority of renal masses containing fat are angiomyolipomas, in the presence of calcif...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s003300050367
更新日期:1998-01-01 00:00:00