Sensorineural hearing loss in ECMO survivors. Extracorporeal membraneous oxygenation.

Abstract:

:Survivors of extracorporeal membraneous oxygenation (ECMO) treatment are at risk for serious neurodevelopmental disorders or neurologic sequelae, but little has been reported about the prevalence of sensorineural hearing loss in these patients. Of 123 ECMO survivors born between 1987 and 1996, at least 30 survivors have confirmed sensorineural hearing loss. Progressive hearing loss has been confirmed in 10 subjects.

journal_name

J Am Acad Audiol

authors

Mann T,Adams K

subject

Has Abstract

pub_date

1998-10-01 00:00:00

pages

367-70

issue

5

eissn

1050-0545

issn

2157-3107

journal_volume

9

pub_type

杂志文章
  • Prediction and statistical evaluation of speech recognition test scores.

    abstract::A speech test evaluation and presentation system is described. The test presentation subsystem has the flexibility and speed of live-voice testing while using recorded test materials. The speech test evaluation subsystem compares an individual subject's test performance on a monosyllabic word test with that of an aver...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Studebaker GA,Gray GA,Branch WE

    更新日期:1999-07-01 00:00:00

  • The Effect of Contralateral Pure Tones on the Compound Action Potential in Humans: Efferent Tuning Curves.

    abstract:BACKGROUND:The compound action potential (CAP) has been suggested in the literature as an alternative to otoacoustic emissions for evaluating the efferent auditory system. However, very few studies have examined efferent influence on auditory nerve potentials in humans. PURPOSE:This study examines the effects of prese...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.15002

    authors: Najem F,Ferraro J,Chertoff M

    更新日期:2016-02-01 00:00:00

  • A FIT solution.

    abstract::The Fusion at Inferred Threshold (FIT) test is a clinically useful procedure for assessing air-conduction pure-tone thresholds in any ear that may not be tested by conventional procedures with masking. It has not been widely reported in the literature. This article describes the FIT test procedure and provides four ca...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Pope ML

    更新日期:1998-06-01 00:00:00

  • Personal amplification for school-age children with auditory processing disorders.

    abstract:BACKGROUND:Children with auditory processing disorders (APD) are described to have a signal-to-noise ratio (SNR) difficulty. Frequency-modulated (FM) systems have been reported to improve this situation. Yet the use of personal amplification that may be more portable has not been attempted. PURPOSE:To determine whethe...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.19.6.3

    authors: Kuk F,Jackson A,Keenan D,Lau CC

    更新日期:2008-06-01 00:00:00

  • Behavioral and electrophysiologic binaural processing in persons with symmetric hearing loss.

    abstract:BACKGROUND:Binaural hearing improves our ability to understand speech and to localize sounds. Hearing loss can interfere with binaural cues, and despite the success of amplification, ∼25% of people with bilateral hearing loss fit with two hearing aids choose to wear only one (e.g., Brooks and Bulmer, 1981). One explana...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.22.3.6

    authors: Leigh-Paffenroth ED,Roup CM,Noe CM

    更新日期:2011-03-01 00:00:00

  • Parents' perceptions of an emerging community-based newborn hearing screening program: A case study.

    abstract::Thirty-six parents of 106 children (34% response rate) born between March 2000 and February 2003 retrospectively completed the "Probe of Parents' Perceptions: An Early Hearing Detection and Intervention (EHDI) Outcome Measure" (PPP) assessing their participation in an emerging community-based newborn hearing screening...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,多中心研究

    doi:10.3766/jaaa.17.3.6

    authors: Danhauer JL,Johnson CE

    更新日期:2006-03-01 00:00:00

  • Evaluation and treatment of severe hyperacusis.

    abstract::A 52-year-old male was evaluated by the authors after initially reporting fullness in his left ear while traveling on an airplane. A unique feature of the patient's complaint was the development of severe bilateral hyperacusis (loudness discomfort levels of between 20-34 dB HL) in spite of the fact that the hearing lo...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Valente M,Goebel J,Duddy D,Sinks B,Peterein J

    更新日期:2000-06-01 00:00:00

  • Valsalva shift among smokers and nonsmokers.

    abstract::Although it has been reported that smoking has deleterious effects on the middle ears of smokers, including their eustachian tubes, investigators have failed to find differences in the tympanometric characteristics of smokers and nonsmokers. In the present study, however, we found that the Valsalva-induced tympanometr...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Steiger JR,Champon TA

    更新日期:1997-08-01 00:00:00

  • Pitch Matching between Electrical Stimulation of a Cochlear Implant and Acoustic Stimuli Presented to a Contralateral Ear with Residual Hearing.

    abstract:BACKGROUND:Cochlear implants (CIs) successfully restore hearing in postlingually deaf adults, but in doing so impose a frequency-position function in the cochlea that may differ from the physiological one. PURPOSE:The CI-imposed frequency-position function is determined by the frequency allocation table programmed int...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.15063

    authors: Tan CT,Martin B,Svirsky MA

    更新日期:2017-03-01 00:00:00

  • Acoustic hemifields in the spatial release from masking of speech by noise.

    abstract::The Hearing-in-Noise Test (HINT) is able to measure the benefit to speech intelligibility in noise conferred when the noise masker is displaced 90 degrees in eccentricity from a speech source located at zero degrees azimuth. Both psychoacoustic and neurophysiological data suggest that the perceptual benefit of the 90-...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.14.9.7

    authors: Phillips DP,Vigneault-MacLean BK,Boehnke SE,Hall SE

    更新日期:2003-11-01 00:00:00

  • Balance function test correlates of the Dizziness Handicap Inventory.

    abstract::Balance Function test data alone cannot capture the reaction that a patient has to balance system disease. The present investigation examined the relations among components of the balance function examination (electronystagmography, rotational testing, and platform posturography) and self-perceived dizziness handicap,...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Jacobson GP,Newman CW,Hunter L,Balzer GK

    更新日期:1991-10-01 00:00:00

  • Hearing and balance screening and referrals for Medicare patients: a national survey of primary care physicians.

    abstract::Hearing and balance problems are prevalent among the elderly. Primary care physicians (PCPs) are important pivotal points of entry for ensuring that patients receive needed audiology services. New Medicare beneficiaries are entitled to one-time preventative examinations including hearing/balance screenings. A 35-item ...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.19.2.7

    authors: Johnson CE,Danhauer JL,Koch LL,Celani KE,Lopez IP,Williams VA

    更新日期:2008-02-01 00:00:00

  • Listener Performance with a Novel Hearing Aid Frequency Lowering Technique.

    abstract:BACKGROUND:Sloping hearing loss imposes limits on audibility for high-frequency sounds in many hearing aid users. Signal processing algorithms that shift high-frequency sounds to lower frequencies have been introduced in hearing aids to address this challenge by improving audibility of high-frequency sounds. PURPOSE:T...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 临床试验,杂志文章

    doi:10.3766/jaaa.16157

    authors: Kirby BJ,Kopun JG,Spratford M,Mollak CM,Brennan MA,McCreery RW

    更新日期:2017-10-01 00:00:00

  • High resolution recording of late cortical surface potentials N1 and gamma band response (GBR).

    abstract::The present investigation was conducted to help determine whether source activity of the direct recorded N1 response differed from that of the gamma band response (GBR). Auditory evoked cortical potential data from two patients with intractable epilepsy undergoing prolonged video EEG monitoring after implantation of s...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Jacobson GP,Henderson J,Smith BJ,Elisevich KV

    更新日期:1998-04-01 00:00:00

  • Speech perception for adult cochlear implant recipients in a realistic background noise: effectiveness of preprocessing strategies and external options for improving speech recognition in noise.

    abstract:BACKGROUND:Although cochlear implant patients are achieving increasingly higher levels of performance, speech perception in noise continues to be problematic. The newest generations of implant speech processors are equipped with preprocessing and/or external accessories that are purported to improve listening in noise....

    journal_title:Journal of the American Academy of Audiology

    pub_type: 临床试验,杂志文章

    doi:10.3766/jaaa.21.7.3

    authors: Gifford RH,Revit LJ

    更新日期:2010-07-01 00:00:00

  • Central auditory processing disorders and reduced motivation: three case studies.

    abstract::The central auditory test results for three normal-hearing children who were initially diagnosed as having a central auditory processing disorder and learning disability are presented. They were referred to the authors for second-opinion consultations. Central auditory processing retesting was performed by the authors...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Silman S,Silverman CA,Emmer MB

    更新日期:2000-02-01 00:00:00

  • Smartphone-Based System for Learning and Inferring Hearing Aid Settings.

    abstract:BACKGROUND:Previous research has shown that hearing aid wearers can successfully self-train their instruments' gain-frequency response and compression parameters in everyday situations. Combining hearing aids with a smartphone introduces additional computing power, memory, and a graphical user interface that may enable...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.15099

    authors: Aldaz G,Puria S,Leifer LJ

    更新日期:2016-10-01 00:00:00

  • Qualind: A method for assessing the accuracy of automated tests.

    abstract::As audiology strives for cost containment, standardization, accuracy of tests, and accountability, greater use of automated tests is likely. Highly skilled audiologists employ quality control factors that contribute to test accuracy, but they are not formally included in test protocols, resulting in a wide range of ac...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.18.1.7

    authors: Margolis RH,Saly GL,Le C,Laurence J

    更新日期:2007-01-01 00:00:00

  • Test-retest reliability of probe-microphone verification in children fitted with open and closed hearing aid tips.

    abstract:PURPOSE:To investigate the test-retest reliability of real-ear aided response (REAR) measures in open and closed hearing aid fittings in children using appropriate probe-microphone calibration techniques (stored equalization for open fittings and concurrent equalization for closed fittings). RESEARCH DESIGN:Probe-micr...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.24.7.11

    authors: Kim H,Ricketts TA

    更新日期:2013-07-01 00:00:00

  • An Evaluation of Motivational Interviewing for Increasing Hearing Aid Use: A Pilot Study.

    abstract:BACKGROUND:Motivational interviewing (MI) has been used in consultation settings to motivate hearing aid users to increase hearing aid usage. However, the effect of MI on those who use their hearing aids only rarely or not at all has not been explored. PURPOSE:The aims of this pilot study were to evaluate the effect o...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.16184

    authors: Solheim J,Gay C,Lerdal A,Hickson L,Kvaerner KJ

    更新日期:2018-09-01 00:00:00

  • Prevalence and Characteristics of Patients with Severe Hyperacusis among Patients Seen in a Tinnitus and Hyperacusis Clinic.

    abstract:PURPOSE:The purpose was to assess the proportion of patients seeking help for tinnitus and/or hyperacusis who have severe hyperacusis and to examine factors associated with severe hyperacusis. RESEARCH DESIGN:This was a retrospective cross-sectional study based on 362 consecutive patients who attended a National Healt...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.17015

    authors: Aazh H,Moore BCJ

    更新日期:2018-07-01 00:00:00

  • Observations on hearing aid users' strategies for controlling the level of their own voice.

    abstract:BACKGROUND:Evidence suggests that hearing-aid users have difficulties with own-voice level control, most likely because their auditory feedback is affected by hearing-aid amplification. PURPOSE:The purpose of this study was to investigate how changes to auditory feedback affect the voice level of hearing-aid users. R...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.20.8.5

    authors: Laugesen S,Nielsen C,Maas P,Jensen NS

    更新日期:2009-09-01 00:00:00

  • Recent changes in the etiology of hearing disorders: perinatal drug exposure.

    abstract::In recent years, we have observed causes of congenital or early onset hearing disorders that had not been recognized or known to exist before. These include drugs passed to an as-yet unborn child. Principal among them is alcohol, but others, such as cocaine, are now also occupying our attention. This article reviews t...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,评审

    doi:

    authors: Gerber SE,Epstein L,Mencher LS

    更新日期:1995-09-01 00:00:00

  • Human frequency-following response correlates of the distortion product at 2F1-F2.

    abstract::We characterized the 2F1-F2 distortion product reflected in the human frequency-following response (FFR). In the first experiment, we evaluated the input-output growth functions of the distortion product at 2F1-F2 (FFR-DP) for three primary pairs. In the second experiment, we tested the effect of primary tone level va...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.15.3.2

    authors: Pandya PK,Krishnan A

    更新日期:2004-03-01 00:00:00

  • Historic perspective of the acoustic otoscope.

    abstract::The acoustic otoscope, originally called the acoustic reflectometer, was developed and produced by John and David Teele in the early 1980s. Since initial production, two different instrument versions have been developed by two separate companies. During the period of time in which the acoustic otoscope has been in pro...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 历史文章,杂志文章

    doi:

    authors: Walsh FP,Cox LC,MacDonald CB

    更新日期:1998-02-01 00:00:00

  • The Benefit of Remote Microphones Using Four Wireless Protocols.

    abstract:BACKGROUND:Many studies have reported the speech recognition benefits of a personal remote microphone system when used by adult listeners with hearing loss. The advance of wireless technology has allowed for many wireless audio transmission protocols. Some of these protocols interface with commercially available hearin...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,随机对照试验

    doi:10.3766/jaaa.15008

    authors: Rodemerk KS,Galster JA

    更新日期:2015-09-01 00:00:00

  • Hearing Aid Benefit in Patients with Mild Sensorineural Hearing Loss: A Systematic Review.

    abstract:BACKGROUND:Untreated sensorineural hearing loss (SNHL) is associated with chronic health-care conditions, isolation, loneliness, and reduced quality of life. Although hearing aids can minimize the negative effects of SNHL, only about one in five persons with SNHL seeks help for communication problems. Many persons wait...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,meta分析

    doi:10.3766/jaaa.14076

    authors: Johnson CE,Danhauer JL,Ellis BB,Jilla AM

    更新日期:2016-04-01 00:00:00

  • Comparison of In-Situ and Retrospective Self-Reports on Assessing Hearing Aid Outcomes.

    abstract:BACKGROUND: Ecological momentary assessment (EMA) is a methodology involving repeated surveys to collect in-situ self-reports that describe respondents' current or recent experiences. Audiology literature comparing in-situ and retrospective self-reports is scarce. PURPOSE: To compare the sensitivity of in-situ and ret...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.1055/s-0040-1719133

    authors: Wu YH,Stangl E,Chipara O,Gudjonsdottir A,Oleson J,Bentler R

    更新日期:2020-12-15 00:00:00

  • Insert earphones for speech recognition testing.

    abstract::Performance-intensity functions for PB word lists were run on 19 normal-hearing subjects and 15 subjects with sensorineural hearing losses. Comparisons were made between standard supra-aural earphones (TDH-49P) and insert phones (ER-3A). Results showed that, at least for the higher sensation levels where word recognit...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Martin FN,Severance GK,Thibodeau L

    更新日期:1991-01-01 00:00:00

  • Evaluation of a BICROS System with a Directional Microphone in the Receiver and Transmitter.

    abstract:BACKGROUND:The bilateral contralateral routing of signals (BICROS) system has provided limited benefit for speech recognition in noise for patients with asymmetric sensorineural hearing loss, even when an automatic adaptive multichannel directional microphone (DM) is in the receiver (Rx) and an omnidirectional micropho...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,随机对照试验

    doi:10.3766/jaaa.15031

    authors: Valente M,Oeding K

    更新日期:2015-11-01 00:00:00