Central auditory processing disorders and reduced motivation: three case studies.

Abstract:

:The central auditory test results for three normal-hearing children who were initially diagnosed as having a central auditory processing disorder and learning disability are presented. They were referred to the authors for second-opinion consultations. Central auditory processing retesting was performed by the authors under the condition of no reinforcement and then the condition of reinforcement with the child's favorite food, hobby, or toy. For all three cases, the central auditory test scores improved markedly bilaterally under the condition of reinforcement as compared with the condition of no reinforcement. We hypothesize that the improvement was related to increased motivation associated with the reinforcement and that these children represented false-positive results on the central auditory test battery. Large-sample studies are needed to investigate the effect of reinforcement on test performance in children with reduced central auditory test scores.

journal_name

J Am Acad Audiol

authors

Silman S,Silverman CA,Emmer MB

keywords:

subject

Has Abstract

pub_date

2000-02-01 00:00:00

pages

57-63

issue

2

eissn

1050-0545

issn

2157-3107

journal_volume

11

pub_type

杂志文章
  • Optimizing the benefit of sound processors coupled to personal FM systems.

    abstract:BACKGROUND:Use of personal frequency modulated (FM) systems significantly improves speech recognition in noise for users of cochlear implants (CI). There are, however, a number of adjustable parameters of the cochlear implant and FM receiver that may affect performance and benefit, and there is limited evidence to guid...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 临床试验,杂志文章

    doi:10.3766/jaaa.19.8.2

    authors: Wolfe J,Schafer EC

    更新日期:2008-09-01 00:00:00

  • Measuring Binaural Temporal-Fine-Structure Sensitivity in Hearing-Impaired Listeners, Using the TFS-AF Test.

    abstract:BACKGROUND:Various methods have been used to measure temporal-fine-structure (TFS) sensitivity in hearing-impaired (HI) listeners. A new method called TFS-adaptive frequency (TFS-AF) test, tracks the highest frequency up to which a person can detect a given interaural phase difference (IPD) in bursts of pure tones. So ...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.18068

    authors: Mathew DS,Sreenivasan A,Alexander A,Palani S

    更新日期:2020-02-01 00:00:00

  • Brief tone discrimination by children with histories of early otitis media.

    abstract::Twelve children, ranging in age from 8.9 to 12.4 years, with histories of severe otitis media with effusion (OME) before age 3, were compared to age-matched cohorts in their ability to discriminate the frequency of tone pulses of 20-, 50-, and 200-msec duration. An adaptive procedure was used in combination with a two...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Cranford JL,Thompson N,Hoyer E,Faires W

    更新日期:1997-04-01 00:00:00

  • Parents' perceptions of an emerging community-based newborn hearing screening program: A case study.

    abstract::Thirty-six parents of 106 children (34% response rate) born between March 2000 and February 2003 retrospectively completed the "Probe of Parents' Perceptions: An Early Hearing Detection and Intervention (EHDI) Outcome Measure" (PPP) assessing their participation in an emerging community-based newborn hearing screening...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,多中心研究

    doi:10.3766/jaaa.17.3.6

    authors: Danhauer JL,Johnson CE

    更新日期:2006-03-01 00:00:00

  • Evaluation of a "direct-comparison" approach to automatic switching in omnidirectional/directional hearing aids.

    abstract:BACKGROUND:Hearing aids today often provide both directional (DIR) and omnidirectional (OMNI) processing options with the currently active mode selected automatically by the device. The most common approach to automatic switching involves "acoustic scene analysis" where estimates of various acoustic properties of the l...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.19.9.6

    authors: Summers V,Grant KW,Walden BE,Cord MT,Surr RK,Elhilali M

    更新日期:2008-10-01 00:00:00

  • Development of a clinical test of musical perception: appreciation of music in cochlear implantees (AMICI).

    abstract::The purpose of this study was to develop a test to assess the ability of persons with cochlear implants (CIs) to interpret musical signals. Up to this time, the main direction in outcomes studies of cochlear implantation has been in relation to speech recognition abilities. With improvement in CI hardware and processi...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 临床试验,杂志文章

    doi:10.3766/jaaa.19.1.6

    authors: Spitzer JB,Mancuso D,Cheng MY

    更新日期:2008-01-01 00:00:00

  • Observations on the relations among occlusion effect, compliance, and vent size.

    abstract::In a clinical experiment, it was found that there is a high correlation between the compliance measured by tympanometry and the minimum size of the earmold vent, which just solves the client's occlusion problem related to his/her own voice when using a hearing aid. For ears with sensorineural hearing losses, complianc...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Carle R,Laugesen S,Nielsen C

    更新日期:2002-01-01 00:00:00

  • A Revision Surgery for Cochlear Implantation in a Case of Incomplete Partition Type I.

    abstract:BACKGROUND:Patients with cochlear malformations were long considered poor candidates for cochlear implantation (CI), and surgical approaches different than the standard facial recess approach were used to access the inner ear. There is no previous long-term follow-up of a patient with significantly malformed inner ear ...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.15107

    authors: Rizk HG,Hagood F,Holcomb MA,Meyer TA

    更新日期:2016-11-01 00:00:00

  • The recordability of two sonomotor responses in young normal subjects.

    abstract:BACKGROUND:It has been reported that up to 40% of patients over age 60 fail to generate a vestibular evoked myogenic potential (VEMP; Su et al, 2004). When this occurs it is difficult to determine whether the absent VEMP represents evidence of bilateral impairment of the vestibulocollic reflex pathway or a normal age-r...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.19.7.3

    authors: McCaslin DL,Jacobson GP,Harry T

    更新日期:2008-07-01 00:00:00

  • Cognition and speech-in-noise recognition: the role of proactive interference.

    abstract:BACKGROUND:Complex working memory (WM) span tasks have been shown to predict speech-in-noise (SIN) recognition. Studies of complex WM span tasks suggest that, rather than indexing a single cognitive process, performance on such tasks may be governed by separate cognitive subprocesses embedded within WM. Previous resear...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.25.10.6

    authors: Ellis RJ,Rönnberg J

    更新日期:2014-11-01 00:00:00

  • Estimating audiometric thresholds using auditory steady-state responses.

    abstract::Human auditory steady-state responses (ASSRs) were recorded using stimulus rates of 78-95 Hz in normal young subjects, in elderly subjects with relatively normal hearing, and in elderly subjects with sensorineural hearing impairment. Amplitude-intensity functions calculated relative to actual sensory thresholds (sensa...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.16.3.3

    authors: Picton TW,Dimitrijevic A,Perez-Abalo MC,Van Roon P

    更新日期:2005-03-01 00:00:00

  • Pitch and Duration Pattern Sequence Tests in 7- to 11-Year-Old Children: Results Depend on Response Mode.

    abstract:BACKGROUND:Pitch pattern sequence (PPS) and duration pattern sequence (DPS) tests are frequently used in the assessment of auditory processing disorder. Current recommendations suggest alternate, interchangeable modes for responding to stimuli. PURPOSE:The objective of the study is to evaluate the influence of respons...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.16132

    authors: Balen SA,Moore DR,Sameshima K

    更新日期:2019-01-01 00:00:00

  • Development of the Three-Clinic Hearing Aid Selection Profile (HASP).

    abstract::The Three-Clinic Hearing Aid Selection Profile (HASP) was developed to assess a patient's beliefs about a number of basic considerations felt to be critical to the hearing aid selection (HAS) process. These characteristics are felt to be key to the acceptance of amplification and include motivation, expectations, cost...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Jacobson GP,Newman CW,Fabry DA,Sandridge SA

    更新日期:2001-03-01 00:00:00

  • Recovery of speech perception performance after prolonged auditory deprivation: case study.

    abstract::The case reported here, a 26-year-old woman, has a bilaterally symmetric, severe-to-profound, sensorineural hearing loss, acquired early in life. Phoneme recognition scores were essentially symmetric at the onset of the investigation. She was basically monaurally aided from age 4 to age 24, at which time a loss of fun...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Boothroyd A

    更新日期:1993-09-01 00:00:00

  • Evaluation of a cognitive test battery in young and elderly normal-hearing and hearing-impaired persons.

    abstract::A cognitive test battery sensitive to processes important for speech understanding was developed and investigated. Test stimuli are presented as text or in an auditory or audiovisual modality. The tests investigate phonologic processing and verbal information processing. Four subject groups, young/elderly with normal-...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Hällgren M,Larsby B,Lyxell B,Arlinger S

    更新日期:2001-07-01 00:00:00

  • Hearing and balance screening and referrals for Medicare patients: a national survey of primary care physicians.

    abstract::Hearing and balance problems are prevalent among the elderly. Primary care physicians (PCPs) are important pivotal points of entry for ensuring that patients receive needed audiology services. New Medicare beneficiaries are entitled to one-time preventative examinations including hearing/balance screenings. A 35-item ...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.19.2.7

    authors: Johnson CE,Danhauer JL,Koch LL,Celani KE,Lopez IP,Williams VA

    更新日期:2008-02-01 00:00:00

  • Effect of age on directional microphone hearing aid benefit and preference.

    abstract:BACKGROUND:Despite the recognition that the directional microphone hearing aid (DMHA) is an important intervention aimed at helping older hearing-impaired adults understand speech in noisy environments, there is little evidence that older listeners can actually benefit from directional processing. PURPOSE:The objectiv...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.21.2.3

    authors: Wu YH

    更新日期:2010-02-01 00:00:00

  • Use of a digital hearing aid with directional microphones in school-aged children.

    abstract::The efficacy of a digital hearing aid with a directional microphone was examined in a school-aged population. Twenty children (9 with a mild-to-moderately-severe hearing loss and 11 with a moderate-to-severe hearing loss) between 7 1/2 and 13 2/3 years of age wore the study hearing aids binaurally for 30 days prior to...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Kuk FK,Kollofski C,Brown S,Melum A,Rosenthal A

    更新日期:1999-11-01 00:00:00

  • A Comparison of Word-Recognition Performances on the Auditec and VA Recorded Versions of Northwestern University Auditory Test No. 6 by Young Listeners with Normal Hearing and by Older Listeners with Sensorineural Hearing Loss Using a Randomized Presentat

    abstract:BACKGROUND:The Auditec of St. Louis and the Department of Veterans Affairs (VA) recorded versions of the Northwestern University Auditory Test No. 6 (NU-6) are in common usage. Data on young adults with normal hearing for pure tones (YNH) demonstrate equal recognition performances on the two versions when the VA versio...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,随机对照试验

    doi:10.3766/jaaa.17135

    authors: Wilson RH

    更新日期:2019-05-01 00:00:00

  • A comparison of gain for adults from generic hearing aid prescriptive methods: impacts on predicted loudness, frequency bandwidth, and speech intelligibility.

    abstract:BACKGROUND:Prescriptive methods have been at the core of modern hearing aid fittings for the past several decades. Every decade or so, there have been revisions to existing methods and/or the emergence of new methods that become widely used. In 2001 Byrne et al provided a comparison of insertion gain for generic prescr...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.22.7.5

    authors: Johnson EE,Dillon H

    更新日期:2011-07-01 00:00:00

  • Effects of stimulus rate and gender on the auditory middle latency response.

    abstract::The effects of stimulus rate and gender on the auditory middle latency response (AMLR) waveforms were examined in 20 young adult male and female subjects. Four different repetition rates were presented to subjects (1.1/sec, 4.1/sec, 7.7/ sec, and 11.3/sec). Stimulus repetition rate had a significant effect on Pa laten...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Tucker DA,Dietrich S,Harris S,Pelletier S

    更新日期:2002-03-01 00:00:00

  • Audiologic monitoring for potential ototoxicity in a phase I clinical trial of a new glycopeptide antibiotic.

    abstract::This study describes audiologic methodology and results for evaluating potential ototoxicity in a phase I clinical trial of a new glycopeptide. This study was conducted under good clinical practices, which are regulated by the US Food and Drug Administration (FDA) (21 Code of Federal Regulations), and input from the F...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:

    authors: Campbell KC,Kelly E,Targovnik N,Hughes L,Van Saders C,Gottlieb AB,Dorr MB,Leighton A

    更新日期:2003-04-01 00:00:00

  • Big Stimulus, Little Ears: Safety in Administering Vestibular-Evoked Myogenic Potentials in Children.

    abstract:BACKGROUND:Cervical and ocular vestibular-evoked myogenic potentials (VEMPs) have become common clinical vestibular assessments. However, VEMP testing requires high intensity stimuli, raising concerns regarding safety with children, where sound pressure levels may be higher due to their smaller ear canal volumes. PURP...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.15097

    authors: Thomas MLA,Fitzpatrick D,McCreery R,Janky KL

    更新日期:2017-05-01 00:00:00

  • Audiometric correlates of the unaided APHAB.

    abstract::The Abbreviated Profile of Hearing Aid Benefit (APHAB) is a self-report questionnaire that is used to quantify the impact of a hearing problem on an individual's daily life. In this investigation, the relationships were explored between typical clinical audiometric data and the four subscale scores of the APHAB admini...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Cox RM,Alexander GC,Gray GA

    更新日期:2003-09-01 00:00:00

  • Improving Hearing Performance for Cochlear Implant Recipients with Use of a Digital, Wireless, Remote-Microphone, Audio-Streaming Accessory.

    abstract:BACKGROUND:Cochlear implant (CI) recipients experience difficulty understanding speech in noise. Remote-microphone technology that improves the signal-to-noise ratio is recognized as an effective means to improve speech recognition in noise; however, there are no published studies evaluating the potential benefits of a...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.15005

    authors: Wolfe J,Morais M,Schafer E

    更新日期:2015-06-01 00:00:00

  • Common Sound Scenarios: A Context-Driven Categorization of Everyday Sound Environments for Application in Hearing-Device Research.

    abstract:BACKGROUND:Evaluation of hearing-device signal-processing features is performed for research and development purposes, but also in clinical settings. Most people agree that the benefit experienced in a hearing-device user's daily life is most important, but laboratory tests are popular since they can be performed unifo...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.15105

    authors: Wolters F,Smeds K,Schmidt E,Christensen EK,Norup C

    更新日期:2016-07-01 00:00:00

  • Masking redux. II: A recommended masking protocol.

    abstract::This is the second in a series of two papers on masking. The objective of these papers is to develop a masking protocol that provides valid measures of threshold and is, in general, faster than the plateau method. In the first paper, a masking method was presented that can replace the traditional plateau method in mos...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.15.1.5

    authors: Turner RG

    更新日期:2004-01-01 00:00:00

  • Efficacy of directional microphone hearing aids: a meta-analytic perspective.

    abstract::The literature suggests that directional microphone hearing aids (DMHAs) are a viable means for improving the signal-to-noise ratio (SNR) for hearing-impaired listeners. The amount of directional advantage they provide, however, remains relatively unclear because of variability observed among individual studies. The p...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,meta分析

    doi:

    authors: Amlani AM

    更新日期:2001-04-01 00:00:00

  • Technical report: distortion product otoacoustic emissions that are not outer hair cell emissions.

    abstract:PURPOSE:To present a case study in order to alert clinicians to the possibility of occurrence of intermodulation distortion during otoacoustic emissions testing that arises from the cavity formed by the external auditory meatus and tympanic membrane rather than from the inner ear, compromising the reliability and valid...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.20.5.3

    authors: Silman S,Emmer MB,Silverman CA

    更新日期:2009-05-01 00:00:00

  • Role of hearing AIDS in tinnitus intervention: a scoping review.

    abstract:BACKGROUND:Tinnitus can have a devastating impact on the quality of life of the sufferer. Although the mechanisms underpinning tinnitus remain uncertain, hearing loss is often associated with its onset, and hearing aids are among the most commonly used tools for its management. PURPOSE:To conduct a scoping review to e...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.24.8.11

    authors: Shekhawat GS,Searchfield GD,Stinear CM

    更新日期:2013-09-01 00:00:00