A new qualitative pattern classification of shear wave elastograghy for solid breast mass evaluation.

Abstract:

OBJECTIVES:To examine the efficacy of qualitative shear wave elastography (SWE) in the classification and evaluation of solid breast masses, and to compare this method with conventional ultrasonograghy (US), quantitative SWE parameters and qualitative SWE classification proposed before. METHODS:From April 2015 to March 2016, 314 consecutive females with 325 breast masses who decided to undergo core needle biopsy and/or surgical biopsy were enrolled. Conventional US and SWE were previously performed in all enrolled subjects. Each mass was classified by two different qualitative classifications. One was established in our study, herein named the Qual1. Qual1 could classify the SWE images into five color patterns by the visual evaluations: Color pattern 1 (homogeneous pattern); Color pattern 2 (comparative homogeneous pattern); Color pattern 3 (irregularly heterogeneous pattern); Color pattern 4 (intralesional echo pattern); and Color pattern 5 (the stiff rim sign pattern). The second qualitative classification was named Qual2 here, and included a four-color overlay pattern classification (Tozaki and Fukuma, Acta Radiologica, 2011). The Breast Imaging Reporting and Data System (BI-RADS) assessment and quantitative SWE parameters were recorded. Diagnostic performances of conventional US, SWE parameters, and combinations of US and SWE parameters were compared. RESULTS:With pathological results as the gold standard, of the 325 examined breast masses, 139 (42.77%) samples were malignant and 186 (57.23%) were benign. The Qual1 showed a higher Az value than the Qual2 and quantitative SWE parameters (all P<0.05). When applying Qual1=Color pattern 1 for downgrading and Qual1=Color pattern 5 for upgrading the BI-RADS categories, we obtained the highest Az value (0.951), and achieved a significantly higher specificity (86.56%, P=0.002) than that of the US (81.18%) with the same sensitivity (94.96%). CONCLUSIONS:The qualitative classification proposed in this study may be representative of SWE parameters and has potential to be relevant assistance in breast mass diagnoses.

journal_name

Eur J Radiol

authors

Cong R,Li J,Guo S

doi

10.1016/j.ejrad.2016.12.021

subject

Has Abstract

pub_date

2017-02-01 00:00:00

pages

111-119

eissn

0720-048X

issn

1872-7727

pii

S0720-048X(16)30415-6

journal_volume

87

pub_type

杂志文章
  • Cardiac findings on non-gated chest computed tomography: A clinical and pictorial review.

    abstract::The use of chest computed tomography (CT) as an imaging test for the evaluation of thoracic pathology has significantly increased during the last four decades. Although cardiopulmonary diseases often overlap in their clinical manifestation, radiologists tend to overlook the heart while interpreting routine chest CT. R...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2015.11.042

    authors: Kanza RE,Allard C,Berube M

    更新日期:2016-02-01 00:00:00

  • Influence of radiation dose and iterative reconstruction algorithms for measurement accuracy and reproducibility of pulmonary nodule volumetry: A phantom study.

    abstract:PURPOSE:To evaluate the influence of radiation dose settings and reconstruction algorithms on the measurement accuracy and reproducibility of semi-automated pulmonary nodule volumetry. MATERIALS AND METHODS:CT scans were performed on a chest phantom containing various nodules (10 and 12mm; +100, -630 and -800HU) at 12...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2014.01.025

    authors: Kim H,Park CM,Song YS,Lee SM,Goo JM

    更新日期:2014-05-01 00:00:00

  • Intra- and interobserver variability in the diagnosis of GERD by real-time MRI.

    abstract::The purpose of this study was to assess the reproducibility of functional and anatomical parameters of swallowing events as determined by real-time MRI at 40 ms temporal resolution (25 frames per second). Twenty-three consecutive patients with gastroesophageal reflux disease (GERD) underwent real-time MRI of the gastr...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2018.04.029

    authors: Seif Amir Hosseini A,Beham A,Uhlig J,Streit U,Uhlig A,Ellenrieder V,Joseph AA,Voit D,Frahm J,Uecker M,Lotz J,Biggemann L

    更新日期:2018-07-01 00:00:00

  • Epidural and subdural contrast in myelography and CT myelography.

    abstract::A retrospective study of 624 lumbar myelographic and CT myelographic procedures was undertaken to evaluate the frequency, radiographic and clinical relevance of contrast medium outside the dural sac. Our findings indicate that epidural contrast is frequently identified on CT scans with highly sensitive window settings...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/0720-048x(93)90013-d

    authors: Milants WP,Parizel PM,de Moor J,Tobback IG,De Schepper AM

    更新日期:1993-02-01 00:00:00

  • 3D cone-beam CT of the ankle using a novel twin robotic X-ray system: Assessment of image quality and radiation dose.

    abstract:PURPOSE:To evaluate image quality (IQ) and radiation dose in cone-beam computed tomography (CBCT) of the ankle using a novel twin robotic X-ray system. METHOD:We examined 16 cadaveric ankles with standard-dose (FD) and low-dose (LD) protocols using the new system's CBCT mode. For comparison, we performed multi-slice C...

    journal_title:European journal of radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.ejrad.2019.108659

    authors: Grunz JP,Kunz AS,Gietzen CH,Weng AM,Veyhl-Wichmann M,Ergün S,Schmitt R,Bley TA,Gassenmaier T

    更新日期:2019-10-01 00:00:00

  • Feasibility of a fixed scan delay technique using a previous bolus tracking technique data for dynamic hepatic CT.

    abstract:OBJECTIVE:To compare the quality of contrast enhancement and hepatic CT images acquired using bolus tracking technique at two different time points and those acquired with fixed scan delay technique using a previous bolus tracking data. MATERIALS AND METHODS:Fifty patients who underwent 3 different hepatic CT exams (2...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2012.02.022

    authors: Takumi K,Fukukura Y,Shindo T,Kumagae Y,Tateyama A,Kamiyama T,Nakajo M

    更新日期:2012-11-01 00:00:00

  • Musculoskeletal ultrasound in childhood.

    abstract::Ultrasonography is one of the first line imaging modalities for the evaluation of musculoskeletal disorders in children. This article provides an overview of the most important pathologic entities in which ultrasonography significantly contributes to the diagnostic workup. ...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2014.04.003

    authors: Maurer K

    更新日期:2014-09-01 00:00:00

  • CT diagnosis of hepatic adenoma.

    abstract::Only few publication have so far been known on case histories in the context of CT-findings of hepatic adenoma (HA). An analysis was, therefore, made of the findings of ten patients with HA. Precontrast and postcontrast scans (dynamic CT), densitometric evaluations (gamma-fit) and "profile" determination were taken in...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:

    authors: Lüning M,Simon C,Dewey C,Decker T,Sperling P

    更新日期:1987-02-01 00:00:00

  • Evaluation of contrast-enhanced digital mammography.

    abstract:PURPOSE:The goal of this prospective study was to evaluate the possible diagnostic benefits of contrast-enhanced digital mammography (CEDM) over conventional mammography. MATERIALS AND METHODS:Our analysis included data from 70 patients with a total of 80 lesions (30 malignant and 50 benign). A series of contrast-enha...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2009.10.002

    authors: Diekmann F,Freyer M,Diekmann S,Fallenberg EM,Fischer T,Bick U,Pöllinger A

    更新日期:2011-04-01 00:00:00

  • Reduced radiation exposure in orthopaedic surgery. Experience with video disc recording in nailing of fractured hips.

    abstract::Radiation exposure from conventional fluoroscopy and from video disc recording was estimated during routine nailing of hip fractures. Mean fluoroscopic time with conventional fluoroscopy was 385 +/- 168 s. and with video disc recording 24 +/- 9 s. The time required for the X-ray system to form one television image, as...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:

    authors: Pietilä K,Pukkila O,Slätis P

    更新日期:1981-05-01 00:00:00

  • Computed tomography role in massive thoracic extramedullary haematopoiesis.

    abstract::A mediastinal mass consisting of haematopoietic tissue and situated in the paravertebral area has been demonstrated in an osteomyelosclerotic patient with diffuse extramedullary haematopoiesis. The internal structure of the mediastinal mass was shown by CT, so a correct diagnosis was made without any invasive procedur...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:

    authors: Dal Pozzo G,Moroni F,Pellegrini GL,Villari N

    更新日期:1982-08-01 00:00:00

  • Brain metabolite changes in alcoholism: localized proton magnetic resonance spectroscopy study of the occipital lobe.

    abstract::Chronic alcoholism is associated with altered brain metabolism, morphology and cognitive abilities. Besides deficits in higher order cognitive functions, alcoholics also show a deficit in the processing of basic sensory information viz. visual stimulation. To assess the metabolic changes associated with this deficit, ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2009.11.003

    authors: Modi S,Bhattacharya M,Kumar P,Deshpande SN,Tripathi RP,Khushu S

    更新日期:2011-07-01 00:00:00

  • Gadolinium dose optimisation in patients with multiple sclerosis: intra- and inter-individual comparisons.

    abstract:OBJECTIVE:To assess the efficacy of single, double and triple doses of 1M gadolinium in the magnetic resonance (MR) evaluation of multiple sclerosis (MS) lesions in order to establish the best trade-off in terms of dose and number of injections. MATERIALS AND METHODS:Twenty-three patients with relapsing remitting or s...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2005.06.004

    authors: Stecco A,Migazzo E,Saponaro A,Scarabino T,Tesser F,Monaco F,Carriero A

    更新日期:2006-01-01 00:00:00

  • CT evaluation of the low severity cervical spine trauma: when is the scout view enough?

    abstract::The aim of the current study was to compare the diagnostic information obtained from a helical CT examination in low severity cervical spine trauma with that from a lateral CT scout view. We included alert and clinically stable patients, who had suffered acute blunt trauma of low or moderate severity. Their scout imag...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2009.03.024

    authors: Theocharopoulos N,Chatzakis G,Karantanas A,Chlapoutakis K,Damilakis J

    更新日期:2010-07-01 00:00:00

  • Effects of reconstruction technique on the quality of abdominal CT angiography: A comparison between forward projected model-based iterative reconstruction solution (FIRST) and conventional reconstruction methods.

    abstract:PURPOSE:This study aimed to compare the quality of abdominal CT angiography (CTA) images obtained using conventional reconstruction algorithms with those obtained using a novel iterative algorithm (forward projected model-based iterative reconstruction solution, FIRST) for evaluating arteries in the abdomen. MATERIALS...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2018.07.015

    authors: Wu R,Hori M,Onishi H,Nakamoto A,Fukui H,Ota T,Nishida T,Enchi Y,Satoh K,Tomiyama N

    更新日期:2018-09-01 00:00:00

  • Low residual diet and hydration improving double contrast examination of the colon.

    abstract::Light food diet and low residual diet with hydration, both combined with Proctosal and Bisacodyl cleansing, were compared in 268 patients in the preparation of the colon for double contrast examination. Low residual diet with hydration resulted in significantly less residual fecal material, no flocculation of the bari...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:

    authors: Virkki R,Mäkelä P

    更新日期:1983-08-01 00:00:00

  • Colon interposition. Long-term radiographic results.

    abstract::Colon interposition was carried out in 12 patients with oesophageal carcinoma and on 38 patients with benign oesophageal disease an average of 71 months before the radiographic examination. Various ischaemic changes including "jejunization", loss of haustration and stricture formation were observed in 15 cases. In 12 ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:

    authors: Isolauri J,Paakkala T,Arajärvi P,Markkula H

    更新日期:1987-11-01 00:00:00

  • Pulmonary infections following bone marrow transplantation: high-resolution CT findings in 35 paediatric patients.

    abstract:PURPOSE:The purpose of this study was to assess the high-resolution CT findings of paediatric patients who had pulmonary infections following bone marrow transplantation (BMT), and to evaluate the differential diagnosis through high-resolution CT of the various pathogens responsible for pulmonary infections after BMT. ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2007.05.021

    authors: Gasparetto TD,Escuissato DL,Marchiori E

    更新日期:2008-04-01 00:00:00

  • The cervical spinal cord in neuromyelitis optica patients: a comparative study with multiple sclerosis using diffusion tensor imaging.

    abstract:INTRODUCTION:This study aims to evaluate "in vivo" the integrity of the normal-appearing spinal cord in patients with neuromyelitis optica (NMO), using diffusion tensor MR imaging, comparing to controls and patients with multiple sclerosis (MS). MATERIALS AND METHODS:We studied 8 patients with NMO and 17 without any n...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2011.11.026

    authors: Pessôa FM,Lopes FC,Costa JV,Leon SV,Domingues RC,Gasparetto EL

    更新日期:2012-10-01 00:00:00

  • How fast can we scan patients with modern (digital) PET/CT systems?

    abstract:PURPOSE:To seek for the minimal duration per bed position with a digital PET system without compromising image quality and lesion detection in patients requiring fast 18F-FDG PET imaging. MATERIALS AND METHODS:19 cancer patients experiencing pain or dyspnea and 9 pediatric patients were scanned on a Vereos system. Lis...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2020.109144

    authors: Lasnon C,Coudrais N,Houdu B,Nganoa C,Salomon T,Enilorac B,Aide N

    更新日期:2020-08-01 00:00:00

  • MR-myelography: a comparison with conventional myelography.

    abstract::After creating a MR pulse sequence, called MR-myelography, the purpose of the study was to evaluate the value of this sequence in comparison to conventional myelography. Twenty consecutive patients were examined with conventional and MR-myelography concerning the clinical questions of chronic lumbago, spinal canal ste...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/0720-048X(95)00730-E

    authors: Hergan K,Amann T,Vonbank H,Hefel C

    更新日期:1996-02-01 00:00:00

  • Advances in paediatric CNS ultrasound.

    abstract::Advanced paediatric ultrasound of the central nervous system (CNS) requires 7 MHz sector and linear transducers, equipment which is highly sensitive to flow velocity (Power Doppler) and additional transcranial axial, coronal and sagittal imaging. New diagnostic possibilities include recognition of subarachnoid hemorrh...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/s0720-048x(97)00087-9

    authors: Winkler P

    更新日期:1998-01-01 00:00:00

  • Iodine quantification to distinguish hepatic neuroendocrine tumor metastasis from hepatocellular carcinoma at dual-source dual-energy liver CT.

    abstract:PURPOSE:To investigate the value of third-generation dual-source dual-energy computed tomography (DECT) iodine quantification to distinguish hepatic neuroendocrine tumor (NET) metastasis from hepatocellular carcinoma (HCC) in non-cirrhotic liver parenchyma. MATERIAL AND METHODS:Forty-six patients (mean age, 64.9 ± 10....

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2018.05.019

    authors: Kaltenbach B,Wichmann JL,Pfeifer S,Albrecht MH,Booz C,Lenga L,Hammerstingl R,D'Angelo T,Vogl TJ,Martin SS

    更新日期:2018-08-01 00:00:00

  • Rare idiopathic intestinal pneumonias (IIPs) and histologic patterns in new ATS/ERS multidisciplinary classification of the IIPs.

    abstract::The new American Thoracic Society/European Respiratory Society (ATS/ERS) update to the multidisciplinary classification of idiopathic interstitial pneumonias (IIPs) defines both rare IIPs and rare histologic patterns of IIPs. Although these diseases are rare, each has some distinguishing imaging and pathologic charact...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2014.11.032

    authors: Johkoh T,Fukuoka J,Tanaka T

    更新日期:2015-03-01 00:00:00

  • Differentiation between benign and malignant colon tumors using fast dynamic gadolinium-enhanced MR colonography; a feasibility study.

    abstract:BACKGROUND:Colorectal cancer will present itself as a bowel obstruction in 16-23% of all cases. However, not all obstructing tumors are malignant and the differentiation between a benign and a malignant tumor can be difficult. The purpose of our study was to determine whether fast dynamic gadolinium-enhanced MR imaging...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2009.03.033

    authors: Achiam MP,Andersen LP,Klein M,Løgager V,Chabanova E,Thomsen HS,Rosenberg J

    更新日期:2010-06-01 00:00:00

  • Spinal cord injury caused by a lateral C1-2 puncture for cervical myelography.

    abstract::A case is reported of a metrizamide injection into the cervical spinal cord during myelography via a lateral C1-2 puncture. This resulted in a mild persistent neurological deficit. The literature is reviewed. ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:

    authors: Müller-Vahl H,Vogelsang H

    更新日期:1986-05-01 00:00:00

  • Liver fat quantification: Comparison of dual-echo and triple-echo chemical shift MRI to MR spectroscopy.

    abstract:PURPOSE:To assess the diagnostic value of MRI using dual-echo (2PD) and triple-echo (3PD) chemical shift imaging for liver fat quantification against multi-echo T2 corrected MR spectroscopy (MRS) used as the reference standard, and examine the effect of T2(*) imaging on accuracy of MRI for fat quantification. MATERIAL...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2015.05.001

    authors: Satkunasingham J,Besa C,Bane O,Shah A,de Oliveira A,Gilson WD,Kannengiesser S,Taouli B

    更新日期:2015-08-01 00:00:00

  • Diagnosis of drowning using post-mortem computed tomography based on the volume and density of fluid accumulation in the maxillary and sphenoid sinuses.

    abstract::Recent studies have reported that drowning victims frequently have fluid accumulation in the paranasal sinuses, most notably the maxillary and sphenoid sinuses. However, in our previous study, many non-drowning victims also had fluid accumulation in the sinuses. Therefore, we evaluated the qualitative difference in fl...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2013.06.015

    authors: Kawasumi Y,Kawabata T,Sugai Y,Usui A,Hosokai Y,Sato M,Saito H,Ishibashi T,Hayashizaki Y,Funayama M

    更新日期:2013-10-01 00:00:00

  • MRI features of epidural extramedullary hematopoiesis.

    abstract::A case of beta-thalassemia intermedia with spinal cord compression due to extramedullary hematopoiesis, which was successfully treated by blood transfusion, is presented. Emphasis was made on the MRI appearance of extramedullary hematopoiesis on different pulse sequences. The theories that aimed to explain the involve...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/s0720-048x(99)00122-9

    authors: Alorainy IA,Al-Asmi AR,del Carpio R

    更新日期:2000-07-01 00:00:00

  • Volume perfusion-CT of the liver: insights and applications.

    abstract::The purpose of this article is to provide an up-to-date view on the spectrum of applications of volume perfusion-CT in the liver. Volume perfusion-CT yields important information on liver architecture and function by enabling quantification of dual liver parenchymal blood supply. Additional characterization of diffuse...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2011.04.010

    authors: Spira D,Schulze M,Sauter A,Brodoefel H,Brechtel K,Claussen C,Horger M

    更新日期:2012-07-01 00:00:00