Liver fat quantification: Comparison of dual-echo and triple-echo chemical shift MRI to MR spectroscopy.

Abstract:

PURPOSE:To assess the diagnostic value of MRI using dual-echo (2PD) and triple-echo (3PD) chemical shift imaging for liver fat quantification against multi-echo T2 corrected MR spectroscopy (MRS) used as the reference standard, and examine the effect of T2(*) imaging on accuracy of MRI for fat quantification. MATERIALS AND METHODS:Patients who underwent 1.5T liver MRI that incorporated 2PD, 3PD, multi-echo T2(*) and MRS were included in this IRB approved prospective study. Regions of interest were placed in the liver to measure fat fraction (FF) with 2PD and 3PD and compared with MRS-FF. A random subset of 25 patients with a wide range of MRS-FF was analyzed with an advanced FF calculation method, to prove concordance with the 3PD. The statistical analysis included correlation stratified according to T2(*), Bland-Altman analysis, and calculation of diagnostic accuracy for detection of MRS-FF>6.25%. RESULTS:220 MRI studies were identified in 217 patients (mean BMI 28.0±5.6). 57/217 (26.2%) patients demonstrated liver steatosis (MRS-FF>6.25%). Bland-Altman analysis revealed strong agreement between 3PD and MRS (mean±1.96 SD: -0.5%±4.6%) and weaker agreement between 2PD and MRS (4.7%±16.0%). Sensitivity of 3PD for diagnosing FF> 6.25% was higher than that of 2PD. 3PD-FF showed minor discrepancies (coefficient of variation <10%) from FF measured with the advanced method. CONCLUSION:Our large series study validates the use of 3PD chemical shift sequence for detection of liver fat in the clinical environment, even in the presence of T2(*) shortening.

journal_name

Eur J Radiol

authors

Satkunasingham J,Besa C,Bane O,Shah A,de Oliveira A,Gilson WD,Kannengiesser S,Taouli B

doi

10.1016/j.ejrad.2015.05.001

subject

Has Abstract

pub_date

2015-08-01 00:00:00

pages

1452-1458

issue

8

eissn

0720-048X

issn

1872-7727

pii

S0720-048X(15)00229-6

journal_volume

84

pub_type

杂志文章
  • Improving the diagnosis of peripheral arterial disease in below-the-knee arteries by adding time-resolved CT scan series to conventional run-off CT angiography. First experience with a 256-slice CT scanner.

    abstract:PURPOSE:Run-off Computed Tomography Angiography (run-off CTA) of the lower extremities has become the method of choice for the diagnostic imaging of patients suffering from peripheral arterial disease (PAD). However, it remains a challenging radiological examination with a considerable risk of non-diagnostic image qual...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2018.11.030

    authors: Buls N,de Brucker Y,Aerden D,Devos H,Van Gompel G,Boonen PT,Nieboer K,Leiner T,de Mey J

    更新日期:2019-01-01 00:00:00

  • Diagnosis of right-sided varicocele: a retrospective comparative study between clinical examination, Doppler findings, US imaging and vascular anatomy at phlebography.

    abstract::Historically varicocele is diagnosed almost exclusively on the left side. The introduction of new imaging techniques has allowed the identification and characterization of right varicocele. This study aims to compare the diagnostic accuracy of various imaging techniques to data obtained using phlebography in the diagn...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2011.05.015

    authors: Cariati M,Pieri S,Agresti P,Cariati M,Candito DF,Damiani G,Marzano D

    更新日期:2012-09-01 00:00:00

  • How does nose blowing effect the computed tomography of paranasal sinuses in chronic sinusitis?

    abstract:OBJECTIVE:Our aim was to determine whether inward or outward movement of the secretions in the paranasal sinuses due to nose blowing after nasal decongestion has any effect on the paranasal sinus computed tomography (CT) images in patients with sinusitis and to asses whether nose blowing may result in misdiagnosis or o...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2004.04.003

    authors: Savranlar A,Uzun L,Ugur MB,Mahmutyazicioglu K,Ozer T,Gundogdu S

    更新日期:2005-02-01 00:00:00

  • CT features of retroperitoneal neurilemmoma.

    abstract:PURPOSE:The aim of this study was to characterize the CT features of retroperitoneal neurilemmoma. METHODS:The CT findings were reviewed in seven patients with retroperitoneal neurilemmoma. RESULTS:All of the tumours were well-demarcated round or oval masses. In five cases, heterogeneous contrast enhancement was note...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/s0720-048x(97)00032-6

    authors: Kinoshita T,Naganuma H,Ishii K,Itoh H

    更新日期:1998-03-01 00:00:00

  • Overview of the radiology of juvenile idiopathic arthritis (JIA).

    abstract::Plain films remain the basic tool for diagnosis and follow-up evaluation of juvenile idiopathic arthritis (JIA). In this paper, we review the new classification of JIA: systemic arthritis. oligoarthritis (persistent), oligoarthritis (extended), polyarticular arthritis (rheumatoid factor negative), polyarticular arthri...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/s0720-048x(99)00152-7

    authors: Cohen PA,Job-Deslandre CH,Lalande G,Adamsbaum C

    更新日期:2000-02-01 00:00:00

  • Computational radiology in skeletal radiography.

    abstract::Recent years have brought rapid developments in computational image analysis in musculo-skeletal radiology. Meanwhile the algorithms have reached a maturity that makes initial clinical use feasible. Applications range from joint space measurement to erosion quantification, and from fracture detection to the assessment...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2009.05.053

    authors: Peloschek P,Nemec S,Widhalm P,Donner R,Birngruber E,Thodberg HH,Kainberger F,Langs G

    更新日期:2009-11-01 00:00:00

  • Evaluation of the efficacy of the guideline on reading CT images of malignant pleural mesothelioma with reference CT films for improving the proficiency of radiologists.

    abstract:PURPOSE:To assess the efficacy of the developed guideline on reading CT images of malignant pleural mesothelioma for improving radiologists' reading proficiency. MATERIALS AND METHODS:Three radiologists independently read the CT films of 22 cases including definite mesothelioma and non-mesothelioma cases at two times ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2012.05.022

    authors: Zhou H,Tamura T,Kusaka Y,Suganuma N,Subhannachart P,Vijitsanguan C,Noisiri W,Hering KG,Akira M,Itoh H,Arakawa H,Ishikawa Y,Kumagai S,Kurumatani N

    更新日期:2013-01-01 00:00:00

  • Image quality of virtual monochromatic images obtained using 320-detector row CT: A phantom study evaluating the effects of iterative reconstruction and body size.

    abstract:OBJECTIVES:To compare the image quality between virtual monochromatic spectral (VMS) images obtained using 320-row detector CT and polychromatic 120-kVp images reconstructed with or without iterative reconstruction using various phantom sizes. MATERIALS AND METHODS:Torso phantoms simulating three patient sizes and con...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2017.08.016

    authors: Okamura T,Yamada Y,Yamada M,Yamazaki A,Shiraga N,Jinzaki M

    更新日期:2017-10-01 00:00:00

  • ¹⁸F-fluorodeoxyglucose uptake on positron emission tomography in mucinous adenocarcinoma.

    abstract:BACKGROUND:The prognostic value of maximum standardized uptake value (maxSUV) on (18)F-fluorodeoxyglucose positron emission tomography (FDG-PET) is known for localized pulmonary adenocarcinoma, which is most commonly non-mucinous adenocarcinoma. We examined the validity of thin-section computed tomography (TS-CT) and F...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2013.07.028

    authors: Murakami S,Saito H,Karino F,Kondo T,Oshita F,Ito H,Nakayama H,Yokose T,Yamada K

    更新日期:2013-11-01 00:00:00

  • Ionizing radiation doses during lower limb torsion and anteversion measurements by EOS stereoradiography and computed tomography.

    abstract:OBJECTIVES:To calculate and compare the doses of ionizing radiation delivered to the organs by computed tomography (CT) and stereoradiography (SR) during measurements of lower limb torsion and anteversion. MATERIALS AND METHODS:A Rando anthropomorphic phantom (Alderson RANDO phantom, Alderson Research Laboratories Inc...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2013.10.026

    authors: Delin C,Silvera S,Bassinet C,Thelen P,Rehel JL,Legmann P,Folinais D

    更新日期:2014-02-01 00:00:00

  • Extramedullary paraspinal hematopoiesis in thalassemia: CT and MRI evaluation.

    abstract::We present a comparative CT and MRI study of the paraspinal extramedullary hematopoiesis in 32 thalassemic patients. The patients were classified into four groups according to the MRI and CT imaging findings. Active recent extramedullary paraspinal hematopoietic masses show soft tissue behavior in both CT and MRI. Old...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/s0720-048x(98)00101-6

    authors: Tsitouridis J,Stamos S,Hassapopoulou E,Tsitouridis K,Nikolopoulos P

    更新日期:1999-04-01 00:00:00

  • Magnetic resonance imaging in the evaluation of the gastric emptying and antral motion: feasibility and reproducibility of a fast not invasive technique.

    abstract:PURPOSE:The aim of this study was to evaluate reproducibility of a fast MRI protocol to measure gastric emptying and motility of the gastric antrum. METHODS AND MATERIALS:Gastric emptying and antral speed were measured in 12 type 1 diabetic patients (mean age 43 years) and 9 healthy volunteers (mean age 31 years). Sub...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2009.04.071

    authors: Carbone SF,Tanganelli I,Capodivento S,Ricci V,Volterrani L

    更新日期:2010-08-01 00:00:00

  • Neurological changes following radiation therapy for head and neck tumours.

    abstract::Radiation therapy is widely used in the treatment of head and neck tumours either as a primary form of treatment or a supplementary modality. Although the benefits of radiation therapy are well established, this treatment modality is not without untoward consequences and complications. The intent of this paper is to h...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/s0720-048x(02)00066-9

    authors: Chong VF,Khoo JB,Chan LL,Rumpel H

    更新日期:2002-11-01 00:00:00

  • Hypervascular mediastinal masses: action points for radiologists.

    abstract::Hypervascular mediastinal masses are a distinct group of rare diseases that include a subset of benign and malignant entities. Characteristic features and known association with syndromes and genetic mutations assist in achieving a diagnosis. Imaging allows an understanding of the vascularity of the lesion and should ...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2014.11.039

    authors: Cabral FC,Trotman-Dickenson B,Madan R

    更新日期:2015-03-01 00:00:00

  • Effect of a novel motion correction algorithm (SSF) on the image quality of coronary CTA with intermediate heart rates: segment-based and vessel-based analyses.

    abstract:PURPOSE:To evaluate the effect of SnapShot Freeze (SSF) reconstruction at an intermediate heart-rate (HR) range (65-75bpm) and compare this method with single-sector reconstruction and bi-sector reconstruction on segmental and vessel bases in retrospective coronary computed tomography angiography (CCTA). MATERIALS AND...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2014.08.002

    authors: Li Q,Li P,Su Z,Yao X,Wang Y,Wang C,Du X,Li K

    更新日期:2014-11-01 00:00:00

  • Using multi-detector-row CT to diagnose ampullary adenoma or adenocarcinoma in situ.

    abstract:OBJECTIVE:To assess the diagnostic accuracy of multi-detector-row computed tomography (MDCT) for the detection of ampullary adenomas or adenocarcinomas in situ. MATERIALS AND METHODS:We retrospectively reviewed 21 computed tomography (CT) images from 20 patients with ampullary tumors, and 22 CT images from 22 patients...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2010.10.022

    authors: Lee M,Kim MJ,Park MS,Choi JY,Chung YE

    更新日期:2011-12-01 00:00:00

  • Is CT-based cinematic rendering superior to volume rendering technique in the preoperative evaluation of multifragmentary intraarticular lower extremity fractures?

    abstract:PURPOSE:Cinematic rendering (CR), a recently launched, FDA-approved rendering technique converts CT image datasets into nearly photorealistic 3D reconstructions by using a unique lighting model. The purpose of this study was to compare CR to volume rendering technique (VRT) images in the preoperative visualization of m...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2020.108911

    authors: Wollschlaeger LM,Boos J,Jungbluth P,Grassmann JP,Schleich C,Latz D,Kroepil P,Antoch G,Windolf J,Schaarschmidt BM

    更新日期:2020-05-01 00:00:00

  • Measurement of single-kidney glomerular filtration function from magnetic resonance perfusion renography.

    abstract::Glomerular filtration rate (GFR) describes the flow rate of filtered fluid through the kidney, and is considered to be the reference standard in the evaluation of renal function. There are many ways to test the GFR clinically, such as serum creatinine concentration, blood urea nitrogen and SPECT renography, however, t...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2015.05.009

    authors: Zeng M,Cheng Y,Zhao B

    更新日期:2015-08-01 00:00:00

  • Focal liver lesion detection and characterization: comparison of non-contrast enhanced and SPIO-enhanced diffusion-weighted single-shot spin echo echo planar and turbo spin echo T2-weighted imaging.

    abstract:PURPOSE:To compare lesion conspicuity and image quality between single-shot spin echo echo planar imaging (SS SE-EPI) before, immediately and 5min after intravenous (IV) injection of superparamagnetic iron oxide (SPIO) for detecting and characterizing focal liver lesions (FLLs). MATERIALS AND METHODS:Twenty-five patie...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2008.09.005

    authors: Coenegrachts K,Matos C,ter Beek L,Metens T,Haspeslagh M,Bipat S,Stoker J,Rigauts H

    更新日期:2009-12-01 00:00:00

  • Imaging of IgG4-related disease in the extracranial head and neck.

    abstract:PURPOSE:Immunoglobulin G4-related disease (IgG4-RD) is a newly defined fibro-inflammatory multisystemic condition defined by a triad of diagnostic criteria based on clinical presentation, biochemical and histopathological findings. Whereas some subsites of this disease have been well described in the literature so far ...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2021.109560

    authors: Dragan AD,Weller A,Lingam RK

    更新日期:2021-01-27 00:00:00

  • Preliminary European intravenous clinical experience with a new, low osmolar, nonionic contrast medium: ioversol (Optiray).

    abstract::The intravenous clinical trial program of ioversol (Optiray), a low osmolar, nonionic, monomeric contrast agent characterized by high hydrophilicity, is evaluated on the basis of results from the first clinical trials conducted in Europe as part of the development of the 300 and 350 mgI/ml formulations: 7 double-blind...

    journal_title:European journal of radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1016/0720-048x(91)90094-c

    authors: Le Mignon MM,Azau C,Arthaud A,Bonnemain B

    更新日期:1991-09-01 00:00:00

  • Radiation dose of CT coronary angiography in clinical practice: objective evaluation of strategies for dose optimization.

    abstract:BACKGROUND:CT coronary angiography (CTCA) is an evolving modality for the diagnosis of coronary artery disease. Radiation burden associated with CTCA has been a major concern in the wider application of this technique. It is important to reduce the radiation dose without compromising the image quality. OBJECTIVES:To e...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2011.02.040

    authors: Yerramasu A,Venuraju S,Atwal S,Goodman D,Lipkin D,Lahiri A

    更新日期:2012-07-01 00:00:00

  • Convolutional neural network-automated hepatobiliary phase adequacy evaluation may optimize examination time.

    abstract:PURPOSE:To develop and evaluate the performance of a fully-automated convolutional neural network (CNN)-based algorithm to evaluate hepatobiliary phase (HBP) adequacy of gadoxetate disodium (EOB)-enhanced MRI. Secondarily, we explored the potential of the proposed CNN algorithm to reduce examination length by applying ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2020.108837

    authors: Cunha GM,Hasenstab KA,Higaki A,Wang K,Delgado T,Brunsing RL,Schlein A,Schwartzman A,Hsiao A,Sirlin CB,Fowler KJ

    更新日期:2020-03-01 00:00:00

  • WITHDRAWN: Endorectal MRI accuracy in auguring tumour location, tumour extent, capsular perforation and seminal vesicle invasion of prostate cancer in north-African men.

    abstract::This article has been withdrawn at the request of the author(s) and/or editor. The Publisher apologizes for any inconvenience this may cause. The full Elsevier Policy on Article Withdrawal can be found at http://www.elsevier.com/locate/withdrawalpolicy. ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2010.12.015

    authors: Janane A,Hajji F,Ismail TO,Elondo JC,Ghadouane M,Ameur A,Abbar M

    更新日期:2011-01-26 00:00:00

  • Digital chest radiography--comparing two types of CRT monitors in a ROC experiment with a chest phantom.

    abstract::Two principally different 1000-line CRT (cathode ray tube) monitors connected to a digital image intensifier system for chest radiography were compared in terms of image quality and viewing comfort. Image quality was assessed by means of ROC analysis. Five observers tried to find simulated pathology positioned over th...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/0720-048x(96)00750-4

    authors: Kheddache S,Angelhed JE,Månsson LG,Denbratt L,Gottfridsson B,Olmarker A

    更新日期:1996-06-01 00:00:00

  • Remote expert consultation for MRI procedures by means of teleradiology.

    abstract::From April 1992 to January 1993, radiology expert opinion for MRI procedures was offered by means of teleradiology. The experiment was carried out in addition to an existing service of a mobile MRI unit. MRI images were sent by means of teleradiology via regular telephone lines from the mobile MRI unit to an academic ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/0720-048x(94)00573-u

    authors: Binkhuysen FH,Ottes FP,Valk J,de Vries C,Algra PR

    更新日期:1995-01-01 00:00:00

  • Improved accuracy of wire-guided breast surgery with supplementary ultrasound.

    abstract::Impalpable breast lesions have always been a challenge for breast surgeons. Stereotactic wire placement is frequently employed for lesion localisation. To improve the accuracy of preoperative localisation in these cases we introduced a supplementary ultrasound scan to identify the exact location of the wire tip. We st...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2006.08.016

    authors: Kolpattil S,Crotch-Harvey M

    更新日期:2006-12-01 00:00:00

  • Low residual diet and hydration improving double contrast examination of the colon.

    abstract::Light food diet and low residual diet with hydration, both combined with Proctosal and Bisacodyl cleansing, were compared in 268 patients in the preparation of the colon for double contrast examination. Low residual diet with hydration resulted in significantly less residual fecal material, no flocculation of the bari...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:

    authors: Virkki R,Mäkelä P

    更新日期:1983-08-01 00:00:00

  • Amide proton transfer (APT) imaging of parotid tumors: Differentiation of malignant and benign tumors.

    abstract:PURPOSE:To assess the usefulness of amide proton transfer (APT) imaging in differentiating parotid tumors. MATERIAL AND METHODS:We retrospectively analyzed 43 histopathologically proven parotid solid tumors with diameters ≥2 cm. Twenty-one tumors were benign and 12 tumors were malignant. Two-dimensional APT imaging wa...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2020.109047

    authors: Kamitani T,Sagiyama K,Togao O,Yamasaki Y,Hida T,Matsuura Y,Murayama Y,Yasumatsu R,Yamamoto H,Yabuuchi H

    更新日期:2020-08-01 00:00:00

  • The influence of knee malalignment on the ankle alignment in varus and valgus gonarthrosis based on radiographic measurement.

    abstract:PURPOSE:The lower limb misalignment as calculated by radiography has an evident effect on the development and progression of knee osteoarthritis (OA). However, whether the knee malalignment has an influence on ankle alignment is unknown. The purpose of this study was to discuss the correlation between knee and ankle al...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2015.11.021

    authors: Gao F,Ma J,Sun W,Guo W,Li Z,Wang W

    更新日期:2016-01-01 00:00:00