Multiple, thin-walled cysts are one of the HRCT features of airspace enlargement with fibrosis.

Abstract:

PURPOSE:Airspace enlargement with fibrosis (AEF) has been identified pathologically as a smoking related change. We sought to identify the HRCT findings of AEF and search for distinguishing features from honeycombing. MATERIALS AND METHODS:50 patients (47 males; mean age 69) were evaluated. All had undergone lobectomy for lung cancer and had confirmed AEF and/or usual interstitial pneumonia (UIP) by pathological evaluation. HRCT findings were first evaluated preresection for resected lobes, and then correlated with the subsequent pathological findings in the resection specimens. Three groups were devised: one with AEF alone to determine the HRCT findings of AEF, a second with AEF and UIP and third with UIP alone. HRCT features of AEF and honeycombing were compared. RESULTS:There were 11 patients (10 male; mean age 69) with AEF alone, 24 patients (22 male; mean age 69) with AEF and UIP, and 15 patients (15 male; mean age 68) with UIP alone. The HRCT on the AEF alone showed subpleural (but not abutting the pleura) multiple thin-walled cysts (MTWCs) in 7 and reticular opacities in 3. The HRCT in AEF and UIP showed MTWCs in 10, reticular opacities in 17; and honeycombing in 5. Among these 35 patients with the pathological finding of AEF (with or without UIP), 17 showed MTWCs. The maximum cyst wall thickness of MTWCs (mean 0.81 mm) was significantly thinner than that of honeycombing (mean 1.56 mm). MTWCs did not locate in lung base and was distant from the pleura. HRCT findings correlated with gross findings on both cysts and honeycombing. No MTWCs were seen in the 15 patients with UIP, 8 of 15 had honeycombing on CT. CONCLUSIONS:We confirmed that HRCT features of AEF were MTWCs and/or reticular opacities. MTWCs might be distinguished from those of honeycomb change. While we prefer the term MTWCs, these sorts of changes have probably been confused with/interpreted as honeycombing and/or empysema in the past.

journal_name

Eur J Radiol

authors

Watanabe Y,Kawabata Y,Kanauchi T,Hoshi E,Kurashima K,Koyama S,Colby TV

doi

10.1016/j.ejrad.2015.01.015

subject

Has Abstract

pub_date

2015-05-01 00:00:00

pages

986-92

issue

5

eissn

0720-048X

issn

1872-7727

pii

S0720-048X(15)00037-6

journal_volume

84

pub_type

杂志文章
  • X-ray contrast-enhancing agents.

    abstract::The author argues that, whatever important and rapid developments may be taking place in imaging technologies, there will be a continuing need for X-ray enhancing agents for a considerable time to come. Areas in which there are current developments, such as non-ionic dimers and compact dimers, are surveyed and a look ...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/s0720-048x(96)01086-8

    authors: Dawson P

    更新日期:1996-11-01 00:00:00

  • Outcomes of premedication for non-ionic radio-contrast media hypersensitivity reactions in Korea.

    abstract:BACKGROUND:Radio-contrast media (CM)-related adverse reactions are important clinical problems that may cause fatal anaphylaxis. Accordingly, it has been common practice to premedicate patients who have had previous reactions to CM with corticosteroids, antihistamines, and H2 blockers to prevent hypersensitive reaction...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2010.06.014

    authors: Kim SH,Lee SH,Lee SM,Kang HR,Park HW,Kim SS,Cho SH,Min KU,Kim YY,Chang YS

    更新日期:2011-11-01 00:00:00

  • Influence of rib structure on detection of subtle lung nodules.

    abstract:PURPOSE:To access the influence of anatomic noise on the detectability of subtle lung nodules depicted on chest radiographs. MATERIAL AND METHODS:From normal chest radiography images, 132 square regions were extracted, of which the centers were on the upper margin of a rib, the inside of a rib, the lower margin of a r...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2006.01.011

    authors: Ikeda M,Ishigaki T,Itoh S

    更新日期:2006-07-01 00:00:00

  • Normal small bowel wall characteristics on MR enterography.

    abstract:PURPOSE:To assess the normal small bowel parameters, namely bowel diameter, bowel wall thickness, number of folds (valvulae connivientes) per 2.5 cm (in.), fold thickness and interfold distance per small bowel segment (duodenum, jejunum, proximal ileum, distal ileum and terminal ileum) on MR enterography. MATERIALS AN...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2009.04.066

    authors: Cronin CG,Delappe E,Lohan DG,Roche C,Murphy JM

    更新日期:2010-08-01 00:00:00

  • Application of CT perfusion imaging to the histological differentiation of adrenal gland tumors.

    abstract:BACKGROUND:CT perfusion imaging has been used in diagnosis and classification of tumors widely and in assess tumor angiogenesis in some organs. However, there are few reports describing CT perfusion imaging of adrenal gland tumors. OBJECTIVE:This study aimed to evaluate the application of CT perfusion imaging in analy...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2010.12.072

    authors: Qin HY,Sun HR,Li YJ,Shen BZ

    更新日期:2012-03-01 00:00:00

  • Clinical value of ⁶⁸Ga-DOTATATE-PET/CT compared to stand-alone contrast enhanced CT for the detection of extra-hepatic metastases in patients with neuroendocrine tumours (NET).

    abstract:PURPOSE:To compare and outline the beneficial skills of combined (68)Ga-DOTATATE positron emission tomography (PET) with concurrent contrast enhanced X-ray computed tomography (ceCT) against stand-alone ceCT in 54 patients with neuroendocrine tumours (NET). METHODS:Patients with histologically confirmed NET and availa...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2015.06.024

    authors: Albanus DR,Apitzsch J,Erdem Z,Erdem O,Verburg FA,Behrendt FF,Mottaghy FM,Heinzel A

    更新日期:2015-10-01 00:00:00

  • Differentiation between pancreatic metastases from renal cell carcinoma and hypervascular neuroendocrine tumour: Use of relative percentage washout value and its clinical implication.

    abstract:PURPOSE:To compare computed tomography (CT) findings in patients with pancreatic metastasis from renal cell carcinoma (pRCC) and patients with hypervascular pancreatic neuroendocrine tumour (pNET) with a focus on the relative percentage washout (RPW). METHODS:We evaluated 16 patients with 37 pRCCs and 28 patients with...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2015.08.007

    authors: Kang TW,Kim SH,Lee J,Kim AY,Jang KM,Choi D,Kim MJ

    更新日期:2015-11-01 00:00:00

  • MRI of orofacial tumors and paragangliomas with 2D GE sequences: indications and optimal sequence parameters.

    abstract::The aim of this paper is to determine to what extent and in which cases 2D gradient echo (2D GE) sequences can be applied alternatively or additionally to spin echo (SE) sequences for improved diagnostic evaluation. Imaging with SE sequences is the most frequently used MR technique in the assessment of ear, nose and t...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/0720-048x(94)90364-6

    authors: Held P

    更新日期:1994-02-01 00:00:00

  • IHE profiles applied to regional PACS.

    abstract::PACS has been widely adopted as an image storage solution that perfectly fits the radiology department workflow and that can be easily extended to other hospital departments. Integrations with other hospital systems, like the Radiology Information System, the Hospital Information System and the Electronic Patient Reco...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2010.05.026

    authors: Fernandez-Bayó J

    更新日期:2011-05-01 00:00:00

  • Digital fluoroscopic radiology: evaluation of the clinical impact.

    abstract::The use of digital image intensifier radiography (DIIR) for examinations in projection radiography is becoming more common. Fluoroscopic controlled contrast studies (barium- or iodine-based), particularly of the gastrointestinal tract, can be performed quickly and easily with a considerable decrease in radiation expos...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/0720-048x(93)90021-e

    authors: Lehmann KJ,Busch HP,Georgi M

    更新日期:1993-06-01 00:00:00

  • Image guided percutaneous splenic interventions.

    abstract:AIM:The objective of this study is to evaluate the efficacy and safety of image-guided percutaneous splenic interventions as diagnostic or therapeutic procedures. MATERIALS AND METHODS:We performed a retrospective review of our interventional records from July 2001 to June 2006. Ninety-five image-guided percutaneous s...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2007.02.011

    authors: Kang M,Kalra N,Gulati M,Lal A,Kochhar R,Rajwanshi A

    更新日期:2007-10-01 00:00:00

  • Subsecond multi-slice computed tomography: basics and applications.

    abstract::The recent advent of multislice-scanning is the first real quantum leap in computed tomography since the introduction of spiral CT in the early 90s. We discuss basic theoretical considerations important for the design of multislice scanners. Then, specific issues, like the design of the detector and spiral interpolati...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/s0720-048x(99)00086-8

    authors: Klingenbeck-Regn K,Schaller S,Flohr T,Ohnesorge B,Kopp AF,Baum U

    更新日期:1999-08-01 00:00:00

  • Triphasic contrast injection improves evaluation of dual energy lung perfusion in pulmonary CT angiography.

    abstract:PURPOSE:Lung perfusion analysis at dual energy CT (DECT) is sensitive to beam hardening artifacts from dense contrast material (CM). We compared two scan and four CM injection protocols in terms of severity of artifacts and attenuation levels in the thoracic vessels. METHODS AND MATERIALS:Data of 120 patients who had ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2010.09.030

    authors: Kerl JM,Bauer RW,Renker M,Weber E,Weisser P,Korkusuz H,Schell B,Larson MC,Kromen W,Jacobi V,Vogl TJ

    更新日期:2011-12-01 00:00:00

  • Differentiating benign from malignant solid breast lesions: combined utility of conventional ultrasound and contrast-enhanced ultrasound in comparison with magnetic resonance imaging.

    abstract:OBJECTIVE:To prospectively evaluate the diagnostic efficacy of conventional ultrasound (US), contrast-enhanced US (CEUS), the combined use of two modalities, and magnetic resonance imaging (MRI) in the differentiation of focal solid breast lesions. MATERIALS AND METHODS:61 patients with BI-RADS category 3-5 breast les...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2012.09.004

    authors: Du J,Wang L,Wan CF,Hua J,Fang H,Chen J,Li FH

    更新日期:2012-12-01 00:00:00

  • Predictive factors for complete excision and underestimation of one-pass en bloc excision of non-palpable breast lesions with the Intact(®) breast lesion excision system.

    abstract:OBJECTIVE:Image-guided percutaneous biopsy is the recommended initial diagnostic procedure for suspicious mammographic lesions. This study was conducted to determine the accuracy of the Intact(®) breast lesion excision system (BLES) and to identify predictive factors for complete excision and underestimation. MATERIAL...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2011.01.049

    authors: Seror JY,Lesieur B,Scheuer-Niro B,Zerat L,Rouzier R,Uzan S

    更新日期:2012-04-01 00:00:00

  • PET imaging for evaluation of metastatic colorectal cancer of the liver.

    abstract::Colorectal cancer is a major cause of cancer death in Western Europe and United States; the liver is the most common site for colorectal metastases. PET has an important role in the management of patients with colorectal liver metastases. It is an effective tool to detect hepatic metastases and to monitor the response...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2005.11.042

    authors: Erturk SM,Ichikawa T,Fujii H,Yasuda S,Ros PR

    更新日期:2006-05-01 00:00:00

  • Shadowing and reverberation artifacts in abdominal ultrasonography.

    abstract::The different features of 821 acoustic shadows recorded during abdominal US examinations were analysed to find out whether any of the features may be used in routine work to help to identify the often invisible structure casting the shadow. A constant shadow with closely spaced high level reverberation echoes is stron...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:

    authors: Suramo I,Päivänsalo M,Vuoria P

    更新日期:1985-05-01 00:00:00

  • Can the IVIM model be used for renal perfusion imaging?

    abstract:OBJECTIVE:Renal perfusion imaging may provide information about the hemodynamic significance of a renal artery stenosis and could improve noninvasive characterization when combined with angiography. It was proposed previously that diffusion sequences could provide useful perfusion indices based on the intravoxel incohe...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/s0720-048x(97)01161-3

    authors: Müller MF,Prasad PV,Edelman RR

    更新日期:1998-02-01 00:00:00

  • Mandibulofacial dysostosis: CT findings of the temporal bones.

    abstract::Six patients of two families with clinically suspected and genetically proven Treacher Collins syndrome and hearing loss were studied by CT of the temporal bone. The objective of this study was to detect the abnormalities and to show the variation of expression of abnormalities. We found a high incidence of asymmetry ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/0720-048x(95)00663-b

    authors: van Vierzen PB,Joosten FB,Marres HA,Cremers CW,Ruijs JH

    更新日期:1995-11-01 00:00:00

  • Feasibility of a fixed scan delay technique using a previous bolus tracking technique data for dynamic hepatic CT.

    abstract:OBJECTIVE:To compare the quality of contrast enhancement and hepatic CT images acquired using bolus tracking technique at two different time points and those acquired with fixed scan delay technique using a previous bolus tracking data. MATERIALS AND METHODS:Fifty patients who underwent 3 different hepatic CT exams (2...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2012.02.022

    authors: Takumi K,Fukukura Y,Shindo T,Kumagae Y,Tateyama A,Kamiyama T,Nakajo M

    更新日期:2012-11-01 00:00:00

  • Diffraction-enhanced imaging microradiography applied in breast samples.

    abstract::The diffraction-enhanced imaging (DEI) is a powerful tool to observe tumors and other diseases in breast tissue and provide more precise diagnostics. In this work DEI was used to analyze breast tissues details that have poor attenuation contrast. An X-ray imaging system with DEI techniques was developed using synchrot...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2008.04.032

    authors: Rocha HS,Pereira GR,Faria P,Kellermann G,Mazzaro I,Tirao G,Giles C,Lopes RT

    更新日期:2008-12-01 00:00:00

  • Iodine quantification to distinguish hepatic neuroendocrine tumor metastasis from hepatocellular carcinoma at dual-source dual-energy liver CT.

    abstract:PURPOSE:To investigate the value of third-generation dual-source dual-energy computed tomography (DECT) iodine quantification to distinguish hepatic neuroendocrine tumor (NET) metastasis from hepatocellular carcinoma (HCC) in non-cirrhotic liver parenchyma. MATERIAL AND METHODS:Forty-six patients (mean age, 64.9 ± 10....

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2018.05.019

    authors: Kaltenbach B,Wichmann JL,Pfeifer S,Albrecht MH,Booz C,Lenga L,Hammerstingl R,D'Angelo T,Vogl TJ,Martin SS

    更新日期:2018-08-01 00:00:00

  • What determines the periportal free air, and ligamentum teres and falciform ligament signs on CT: can these specific air distributions be valuable predictors of gastroduodenal perforation?

    abstract:PURPOSE:The purpose of this retrospective study was to determine what gives rise to the periportal free air, and ligamentum teres and falciform ligament signs on CT in patients with gastrointestinal (GI) tract perforation, and whether these specific air distributions can play a clinically meaningful role in the diagnos...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2009.07.033

    authors: Choi AL,Jang KM,Kim MJ,Koh SH,Lee Y,Min K,Choi D

    更新日期:2011-02-01 00:00:00

  • Degenerative disc disease of the lumbar spine: a prospective comparison of fast T1-weighted fluid-attenuated inversion recovery and T1-weighted turbo spin echo MR imaging.

    abstract:OBJECTIVE:To compare fast T1-weighted fluid-attenuated inversion recovery (FLAIR) and T1-weighted turbo spin-echo (TSE) imaging of the degenerative disc disease of the lumbar spine. MATERIALS AND METHODS:Thirty-five consecutive patients (19 females, 16 males; mean age 41 years, range 31-67 years) with suspected degene...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2004.09.009

    authors: Erdem LO,Erdem CZ,Acikgoz B,Gundogdu S

    更新日期:2005-08-01 00:00:00

  • The role of Thallium-201 scintigraphy and Tc-99m pentavalent dimercaptosuccinic acid in diagnosis and grading of chondrosarcoma.

    abstract:PURPOSE:Distinguishing between enchondromas and low-grade (grade 1) chondrosarcomas can be challenging. The aim of this study was to investigate the role of Thallium-201 scintigraphy and Technetium-99 m pentavalent dimercaptosuccinic acid (Tc-99 m DMSA (V)) in the diagnosis and grading of chondrosarcomas. METHODS:232 ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2020.108846

    authors: Jo O,Schlicht S,Slavin J,Di Bella C,Pang G,Powell G,Spelman T,Choong PF

    更新日期:2020-04-01 00:00:00

  • Improved detection of localized prostate cancer using co-registered MRI and 11C-acetate PET/CT.

    abstract:OBJECTIVES:We aimed to study the ability of contrast enhanced MRI at 1.5 T and 11C-acetate PET/CT, both individually and using fused data, to detect localized prostate cancer. METHODS:Thirty-six men with untreated prostate cancer and negative for metastatic disease on pelvic CT and bone scan were prospectively enrolle...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2011.12.043

    authors: Jambor I,Borra R,Kemppainen J,Lepomäki V,Parkkola R,Dean K,Alanen K,Arponen E,Nurmi M,Aronen HJ,Minn H

    更新日期:2012-11-01 00:00:00

  • Local thermal ablation of renal cell carcinoma.

    abstract:PURPOSE:With evolving local thermal ablation technology, the clinical application of thermal ablation has been actively investigated in the treatment for renal cell carcinoma. We review the evolution and current status of radiofrequency ablation and microwave ablation for renal cell carcinoma. MATERIALS AND METHODS:Al...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2010.12.056

    authors: Feng B,Liang P

    更新日期:2012-03-01 00:00:00

  • Virtual monoenergetic reconstructions of dynamic DECT acquisitions for calculation of perfusion maps of blood flow: Quantitative comparison to conventional, dynamic 80 kVp CT perfusion.

    abstract:PURPOSE:Investigation of potential improvements in dynamic CT perfusion measurements by exploitation of improved visualization of contrast agent in virtual monoenergetic reconstructions of images acquired with dual-energy computed tomography (DECT). METHOD:For 17 patients with pancreatic carcinoma, dynamic dual-source...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2020.109262

    authors: Skornitzke S,Kauczor HU,Stiller W

    更新日期:2020-10-01 00:00:00

  • Clinical and surgical correlation of hip MR arthrographic findings in adolescents.

    abstract:OBJECTIVE:The purpose of this study was to analyze the utility of MRA-H in adolescents by comparing the results of imaging with surgical findings and/or clinical outcome. MATERIAL AND METHODS:After obtaining appropriate IRB approval, the Radiologic Information System database was queried for all patients 13-18 years o...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2016.03.031

    authors: Jawahar A,Vade A,Lomasney L,Okur G,Evans D,Subbaiah P

    更新日期:2016-06-01 00:00:00

  • Complications of percutaneous stereotactic vacuum assisted breast biopsy system utilizing radio frequency.

    abstract:OBJECTIVE:The Breast Lesion Excision System (BLES) is a novel, automatic breast biopsy device that utilizes radiofrequency to excise suspicious non-palpable mammographic lesions. The purpose of the present prospective study is to report and evaluate the complications of this new technique. MATERIALS AND METHODS:In a t...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2011.12.023

    authors: Al-Harethee W,Theodoropoulos G,Filippakis GM,Papapanagiotou I,Matiatou M,Georgiou G,Kalles V,Koulocheri D,Nonni A,Konstadoulakis MM,Manouras A,Zografos GC

    更新日期:2013-04-01 00:00:00