Abstract:
BACKGROUND:Our aim was to evaluate the intermittent use of a handheld ECG system for detecting silent arrhythmias and cardiac autonomic dysfunction in children with univentricular hearts. METHODS:Twenty-seven patients performed intermittent ECG recordings with handheld devices during a 14-day period. A manual arrhythmia analysis was performed. We analyzed heart rate variability (HRV) using scatter plots of all interbeat intervals (Poincaré plots) from the total observation period. Reference values of HRV indices were determined from Holter-ECGs in 41 healthy children. RESULTS:One asymptomatic patient had frequent ventricular extra systoles. Another patient had episodes with supraventricular tachycardia (with concomitant palpitations). Seven patients showed reduced HRV. CONCLUSIONS:Asymptomatic arrhythmia was detected in one patient. The proposed method for pooling of intermittent recordings from handheld or similar devices may be used for detection of arrhythmias as well as for cardiac autonomic dysfunction.
journal_name
J Electrocardioljournal_title
Journal of electrocardiologyauthors
Dahlqvist JA,Karlsson M,Wiklund U,Hörnsten R,Rydberg Adoi
10.1016/j.jelectrocard.2014.02.006subject
Has Abstractpub_date
2014-05-01 00:00:00pages
374-82issue
3eissn
0022-0736issn
1532-8430pii
S0022-0736(14)00055-7journal_volume
47pub_type
杂志文章abstract:BACKGROUND:The ventricular repolarization (VR) response to short-lasting coronary occlusion has been characterized by 3-dimensional vectorcardiography during angioplasty in humans; the T-vector loop becomes distorted (increased T(avplan)) and more circular (decreased T(eigenvalue)), but these changes have not been rela...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/j.jelectrocard.2008.11.001
更新日期:2009-05-01 00:00:00
abstract:BACKGROUND:We studied whether social media applications can serve as effective educational tools for teaching electrocardiogram (ECG) interpretation to medical residents. METHODS:39 emergency, family, and internal medicine residents participated in the 33-week "ECG of the Week" curriculum via Facebook and Twitter. ECG...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/j.jelectrocard.2017.04.010
更新日期:2017-01-01 00:00:00
abstract:OBJECTIVES:To define clinical correlates of low voltage isolated to precordial leads on the surface electrocardiogram (ECG). INTRODUCTION:Low voltage (V) on the ECG is defined as QRS V<5mm in all limb leads and <10mm in all precordial leads. The diagnostic use of ECGs with low voltage isolated to the precordial leads ...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/j.jelectrocard.2017.04.016
更新日期:2017-01-01 00:00:00
abstract:BACKGROUND:Several studies have documented the prognostic significance of the signal-averaged electrocardiogram (SAECG) both after myocardial infarction and nonischemic cardiomyopathy. However, whether the SAECG can identify patients with implantable cardioverter-defibrillator (ICD) who receive appropriate therapy has ...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/j.jelectrocard.2005.08.009
更新日期:2006-04-01 00:00:00
abstract:BACKGROUND AND PURPOSE:Descriptions of the significance of ST segment or QRS abnormalities in myocarditis are limited because documentation of the diagnosis has previously required myocardial biopsy. Late gadolinium enhancement (LGE) and T2 weighted imaging in the midventricular wall on cardiac magnetic resonance imagi...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/j.jelectrocard.2014.07.018
更新日期:2014-11-01 00:00:00
abstract::Morphology of ventricular ectopic complexes was examined in 1,746 ECGs of 149 patients with permanent ventricular pacemakers. In 20 of 80 patients (25%) the morphology of ventricular ectopic complexes was similar to that of the paced complex. This resulted in a ventricular couplet where the spontaneous premature compl...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/s0022-0736(80)80039-2
更新日期:1980-04-01 00:00:00
abstract::We found significant variation within each computer and cardiologist method for measurement of the ECG waveform intervals. Comparison between methods revealed that the HP system had a smaller variability than the MAC or the cardiologist, and that the MAC had a smaller variability than the cardiologist. No variability ...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/s0022-0736(07)80110-5
更新日期:1989-01-01 00:00:00
abstract::Postoperative atrial fibrillation is common after cardiac surgery. Prediction of which patients will develop postoperative atrial fibrillation would be clinically useful. Increased P-wave duration, suggesting atrial conduction delay and measured from preoperative electrocardiograms, predicts postoperative atrial fibri...
journal_title:Journal of electrocardiology
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1016/j.jelectrocard.2004.01.003
更新日期:2004-04-01 00:00:00
abstract:BACKGROUND:For the assessment of patients with chest pain, the 12-lead electrocardiogram (ECG) is the initial investigation. Major management decisions are based on the ECG findings, both for attempted coronary artery revascularization and risk stratification. The aim of this study was to determine if the current 6 pre...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/j.jelectrocard.2011.03.010
更新日期:2011-07-01 00:00:00
abstract:BACKGROUND:Many variants of the spatial QRS-T angle (QRS-Ta) are in use. We aimed to identify the best QRS-Ta for all-cause mortality prediction among different variants. METHODS:6667 individuals from the Inter99 General Population Study were followed for a median of 12.7 years. Vectorcardiograms were calculated using...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/j.jelectrocard.2018.05.011
更新日期:2018-01-01 00:00:00
abstract::An academic 12-lead electrocardiogram (ECG) core laboratory aims to provide the highest possible quality ECG recording, measurement, and storage to aid clinicians in research into important cardiovascular outcomes and to maximize the credibility of scientific results based solely, or in part, on ECG data. This positio...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1054/jelc.2001.22028
更新日期:2001-01-01 00:00:00
abstract::Here we report the identification of two novel mutations in a previously asymptomatic young man who suffered an out-of-hospital sudden cardiac arrest. During following evaluation, diagnosis of early stage dilated cardiomyopathy was established, while electrocardiogram monitoring showed frequent complex ventricular arr...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/j.jelectrocard.2018.12.015
更新日期:2019-01-01 00:00:00
abstract:BACKGROUND:Simulation of the electrical activation of the heart and its comparison with real in vivo activation is a promising method in testing potential determinants of excitation. Simulation of the electrical activity of the human heart is now emerging as a step forward for understanding and predicting electrophysio...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/j.jelectrocard.2008.12.008
更新日期:2009-03-01 00:00:00
abstract::Cardiac hemangioma is a rare primary cardiac tumor. We reported the case of patient with left ventricular hemangioma who was referred to our hospital complaining of palpitation for one week. 24 h Holter revealed high episode of ventricular arrhythmia. Echocardiography showed a mass at left ventricle, which was also co...
journal_title:Journal of electrocardiology
pub_type: 杂志文章,评审
doi:10.1016/j.jelectrocard.2017.04.014
更新日期:2017-01-01 00:00:00
abstract::Catheter ablation procedures are performed by highly trained and experienced cardiology subspecialists. Yet the massive amount of data produced during these procedures creates a data overload problem that can impede the performance of even the best practitioners. This may be evidenced by (1) overlooking important sign...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/s0022-0736(96)80063-x
更新日期:1996-01-01 00:00:00
abstract::We present an example of sudden modification in QRS morphology during ventricular pacing inside a scar-related isthmus. This is explained by a "concealed" sudden block in both the orthodromic and antidromic wavefront directions, allowing then the activation to proceed through a now overt antidromic conduction. ...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/j.jelectrocard.2016.07.035
更新日期:2016-01-01 00:00:00
abstract::The Electrocardiogram has extensively been used for evaluation and triage of patients with acute chest pain. The clinician admitting a patient with ST elevation acute myocardial infarction should be able to estimate the size and location of the ischemic area at risk, how much of the ischemic myocardium has already und...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/j.jelectrocard.2005.01.003
更新日期:2005-04-01 00:00:00
abstract::Atrial arrhythmias are diagnosed on the basis of the analysis of P wave morphology, timing and rate, the surface electrocardiogram, and intracardiac recordings. Recent intracardiac studies have demonstrated dissimilar atrial rhythms with direct intra-atrial recordings, the former otherwise not evident on the surface E...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/0022-0736(91)90010-j
更新日期:1991-04-01 00:00:00
abstract::We reported a case of Wolff-Parkinson-White syndrome with atrial double potential in coronary sinus (CS) electrograms during paroxysmal supraventricular tachycardia and ventricular pacing. The first component was low in frequency, and its timing was the same as atrial potential recorded by ablation catheter above the ...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/j.jelectrocard.2007.02.002
更新日期:2007-09-01 00:00:00
abstract::The de Winter electrocardiogram (ECG) pattern may signify proximal left anterior descending artery (LAD) occlusion and was suggested to be managed as ST-segment elevation myocardial infarction (STEMI) equivalent for urgent angiography and reperfusion therapy. However, cardiac catheter laboratory is not readily or time...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/j.jelectrocard.2019.06.010
更新日期:2019-01-01 00:00:00
abstract::The Brugada syndrome is characterized by ST-segment elevation in the right precordial leads (V1 through V3) and an episode of ventricular fibrillation in the absence of structural heart disease. SCN5A, the gene encoding the alpha subunit of the sodium channel, is the only gene thus far linked to the Brugada syndrome b...
journal_title:Journal of electrocardiology
pub_type: 杂志文章,评审
doi:10.1016/j.jelectrocard.2005.06.005
更新日期:2005-10-01 00:00:00
abstract::Eight sets of electrocardiographic (ECG) criteria for the localization of accessory conduction pathway (ACP) were evaluated on 182 patients with a single ACP. The Rosenbaum criteria identified 78.6% of the left-sided and 94.0% of the right-sided ACPs. Four of the other seven sets of criteria demonstrated a sensitivity...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/0022-0736(92)90005-k
更新日期:1992-07-01 00:00:00
abstract:INTRODUCTION:"Cardiac memory" (CM) refers to a change in repolarization induced by an altered pathway of activation, manifested after resumption of spontaneous ventricular activation (SVA). AIMS:To investigate for the first time in humans the effects of left ventricular (LV) pacing on CM development through vectorcard...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/j.jelectrocard.2015.05.007
更新日期:2015-07-01 00:00:00
abstract::The present study describes the successful radiofrequency ablation of an uncommon type of A-V nodal tachycardia. Electroanatomical mapping of the right atria was used to locate the region of the earliest atrial activation and allowed for positioning of the ablation catheter and a successful 25-watt radiofrequency burn...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1054/jelc.2002.29943
更新日期:2002-01-01 00:00:00
abstract:BACKGROUND:Coronary artery disease (CAD) is a leading cause of death and disability. Conventional non-invasive diagnostic modalities for the detection of stable CAD at rest are subject to significant limitations: low sensitivity, and personal expertise. We aimed to develop a reliable and time-cost efficient screening t...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/j.jelectrocard.2019.12.018
更新日期:2020-01-01 00:00:00
abstract::Computer analysis of electrocardiograms (ECGs) provides a large amount of ECG measurement data, which may be used for diagnostic classification and storage in ECG databases. Until now, neither error limits for ECG measurements have been specified nor has their influence on diagnostic statements been systematically inv...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/s0022-0736(96)80022-7
更新日期:1996-01-01 00:00:00
abstract:BACKGROUND:Cardiovascular complications are considered a significant problem in patients with chronic kidney disease (CKD). Body surface potential mapping (BSPM) is a noninvasive method that is useful in detecting early changes involving the heart. The aim of the study was to evaluate possible abnormalities within the ...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/j.jelectrocard.2008.09.007
更新日期:2009-03-01 00:00:00
abstract:BACKGROUND:Temporary-permanent pacemakers [TPPM] are externally placed permanent generators attached to active fixation transvenous leads. TPPM can be used as an alternative to standard temporary pacing leads when placement of a permanent pacemaker is contraindicated. We sought to determine the incidence and risk facto...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/j.jelectrocard.2016.05.004
更新日期:2016-07-01 00:00:00
abstract:OBJECTIVE:We have previously used a 12-lead, signal-processed ECG to calculate blood potassium levels. We now assess the feasibility of doing so with a smartphone-enabled single lead, to permit remote monitoring. PATIENTS AND METHODS:Twenty-one hemodialysis patients held a smartphone equipped with inexpensive FDA-appr...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/j.jelectrocard.2017.06.008
更新日期:2017-01-01 00:00:00
abstract::Previous studies indicate that the predictive value of atrial fibrillatory rate in patients undergoing cardioversion of atrial fibrillation (AF) of long duration is limited. The present study investigates signal entropy in this setting. Standard 12-lead electrocardiograms (ECGs) were recorded from 66 consecutive patie...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/j.jelectrocard.2010.10.033
更新日期:2011-03-01 00:00:00