Abstract:
:We reported a case of Wolff-Parkinson-White syndrome with atrial double potential in coronary sinus (CS) electrograms during paroxysmal supraventricular tachycardia and ventricular pacing. The first component was low in frequency, and its timing was the same as atrial potential recorded by ablation catheter above the mitral annulus by transseptal approach; the second portion was high in frequency. The accessory pathway conduction was completely eliminated after ablation on the atrial site. We speculated that the discrete musculature connection between left atrium and CS was responsible for the pattern of double potential activation in the CS electrograms during paroxysmal supraventricular tachycardia and ventricular pacing.
journal_name
J Electrocardioljournal_title
Journal of electrocardiologyauthors
Zheng LR,Chen Y,Lian MJ,Wang LH,Zhu JH,Chen JZ,Tiao QMdoi
10.1016/j.jelectrocard.2007.02.002subject
Has Abstractpub_date
2007-09-01 00:00:00pages
434-6issue
5eissn
0022-0736issn
1532-8430pii
S0022-0736(07)00048-9journal_volume
40pub_type
杂志文章abstract::The Electrocardiogram has extensively been used for evaluation and triage of patients with acute chest pain. The clinician admitting a patient with ST elevation acute myocardial infarction should be able to estimate the size and location of the ischemic area at risk, how much of the ischemic myocardium has already und...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/j.jelectrocard.2005.01.003
更新日期:2005-04-01 00:00:00
abstract::We have analyzed the Wilson ventricular gradient in terms of body surface potential maps and of the reduction of such surface patterns to equivalent dipoles or vectors. While the ventricular gradient traditionally was treated as first a scalar, then a vector concept, we found that the three entities (QRS area, T area,...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/s0022-0736(81)81013-8
更新日期:1981-10-01 00:00:00
abstract::We recently reported that signal averaged electrocardiograms (SAECG) measurements possess a circadian rhythm and are closely related to heart rate or heart rate variability in healthy volunteers. This study determines the influence of autonomic tone on the filtered QRS (f-QRS) duration from SAECG by using pharmacologi...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/s0022-0736(00)80096-5
更新日期:2000-01-01 00:00:00
abstract::The widespread clinical application of implantable electrical defibrillation devices has engendered considerable interest into the mechanism of action of such devices. In addition, better means of rapid detection of postshock efficacy have been sought. The authors performed this study to test the following hypotheses:...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/0022-0736(90)90073-b
更新日期:1990-01-01 00:00:00
abstract::Atrial arrhythmias are diagnosed on the basis of the analysis of P wave morphology, timing and rate, the surface electrocardiogram, and intracardiac recordings. Recent intracardiac studies have demonstrated dissimilar atrial rhythms with direct intra-atrial recordings, the former otherwise not evident on the surface E...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/0022-0736(91)90010-j
更新日期:1991-04-01 00:00:00
abstract::The modified Sgarbossa criteria have been established to aid in the diagnosis of ST-elevation myocardial infarction in patients with left bundle branch block. Thus far, the sensitivities and specificities of the Sgarbossa signs have only been evaluated retrospectively in cohorts of patients with and without occlusive ...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/j.jelectrocard.2020.09.011
更新日期:2020-01-01 00:00:00
abstract::The American College of Cardiology recommends that patients with high risk acute myocardial infarction (AMI) be triaged to hospitals with percutaneous transluminal coronary angioplasty capability. However, there are no prehospital triage criteria to select candidates for bypassing community hospitals and being taken d...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1054/jelc.2000.20299
更新日期:2000-01-01 00:00:00
abstract::Effects of pirmenol hydrochloride and lidocaine hydrochloride on intraventricular conduction were examined in the infarcted heart of anesthetized dogs. The effects of the drugs on the excitation induced by ventricular stimulations were determined with coupling intervals between 150 and 1,000 ms. Effects of the drugs o...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/0022-0736(91)90020-m
更新日期:1991-10-01 00:00:00
abstract:OBJECTIVE:We have previously used a 12-lead, signal-processed ECG to calculate blood potassium levels. We now assess the feasibility of doing so with a smartphone-enabled single lead, to permit remote monitoring. PATIENTS AND METHODS:Twenty-one hemodialysis patients held a smartphone equipped with inexpensive FDA-appr...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/j.jelectrocard.2017.06.008
更新日期:2017-01-01 00:00:00
abstract::Many electrocardiographic criteria have been proposed for the differentiation of ventricular extrasystole and supraventricular conduction with aberrancy in atrial fibrillation but the validity of these have not been confirmed by intracardiac studies. We recorded His bundle electrograms in nineteen patients (eleven men...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/s0022-0736(85)80033-9
更新日期:1985-01-01 00:00:00
abstract:BACKGROUND:Several studies have documented the prognostic significance of the signal-averaged electrocardiogram (SAECG) both after myocardial infarction and nonischemic cardiomyopathy. However, whether the SAECG can identify patients with implantable cardioverter-defibrillator (ICD) who receive appropriate therapy has ...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/j.jelectrocard.2005.08.009
更新日期:2006-04-01 00:00:00
abstract::Isomagnetic maps were recorded in normal subjects and in patients with systolic overloading of the right ventricle. The isomagnetic maps examined in this study indicated the instantaneous current source of the heart by applying the "corkscrew rule." The magnetic field recorded by a second derivative gradiometer detect...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/s0022-0736(88)80013-x
更新日期:1988-04-01 00:00:00
abstract:BACKGROUND:Patients hospitalized for suspected acute coronary syndrome (ACS) are at risk for transient myocardial ischemia. During the "rule-out" phase, continuous ECG ST-segment monitoring can identify transient myocardial ischemia, even when asymptomatic. However, current ST-segment monitoring software is vastly unde...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/j.jelectrocard.2017.10.005
更新日期:2018-01-01 00:00:00
abstract::Ventricular fibrillation (VF), uninterrupted, is fatal within minutes. Implantable cardioverter defibrillators (ICDs) sense ventricular electrograms (EGMs) during VF and detect the VF rhythm (a sequence of VF sensed events) to deliver a shock to terminate VF and save lives. VF sensing and detection in Medtronic ICDs h...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/j.jelectrocard.2018.08.034
更新日期:2018-01-01 00:00:00
abstract::Body surface potential mapping was performed in 60 clinical cases and an ideal 0 potential was calculated in each case at 2msec intervals, which corresponds to the potential at infinity. Maximal deviation of the Wilson terminal voltage the ideal potential was 0.14mv on the average. Time course of potential variations ...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/s0022-0736(05)80054-8
更新日期:1995-10-01 00:00:00
abstract::The paper electrocardiogram (ECG) has been widely used for cardiac assessment for well over a century. ECGs can be obtained quickly and cheaply. For this reason, an ever-growing amount of paper ECG records continue to accumulate, some of which are stored into a paper-only format. Converting paper ECGs into digital for...
journal_title:Journal of electrocardiology
pub_type: 杂志文章,评审
doi:10.1016/j.jelectrocard.2016.09.007
更新日期:2017-01-01 00:00:00
abstract:BACKGROUND:Our aim was to evaluate the intermittent use of a handheld ECG system for detecting silent arrhythmias and cardiac autonomic dysfunction in children with univentricular hearts. METHODS:Twenty-seven patients performed intermittent ECG recordings with handheld devices during a 14-day period. A manual arrhythm...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/j.jelectrocard.2014.02.006
更新日期:2014-05-01 00:00:00
abstract::We describe a 75-year-old male patient with two-vessel coronary artery disease, who developed transient left posterior hemiblock (LPH) while undergoing an exercise treadmill test (ETT). The intraventricular conduction abnormality initially had the features of alternating LPH, which evolved to stable LPH prior to dissi...
journal_title:Journal of electrocardiology
pub_type: 杂志文章,评审
doi:10.1016/s0022-0736(99)90022-5
更新日期:1999-01-01 00:00:00
abstract::A common basis of orthogonal waveform functions was derived from 128 lead body surface potential maps of 405 subjects. Twelve such orthogonal functions or frames were adequate for reconstruction of original ECGs from the beginning of QRS to the end of T. A larger number of frames (18) was required when basis functions...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/s0022-0736(85)80016-9
更新日期:1985-10-01 00:00:00
abstract:AIM:P-wave dispersion (PD), and duration has been reported to be associated with inhomogeneous and discontinuous propagation of sinus impulses. The aim of this study was to investigate the PD in patients with coronary slow flow (CSF) phenomenon. METHODS:Study population included 48 patients with angiographically prove...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/j.jelectrocard.2006.06.004
更新日期:2008-01-01 00:00:00
abstract:BACKGROUND:We assessed the specificity of wide QRS complex tachycardia (WCT) differentiating algorithms in patients with preexistent left bundle branch block (LBBB) and heart failure. METHODS:Three hundred fourteen patients with resynchronization devices were retrospectively screened. electrocardiograms with supravent...
journal_title:Journal of electrocardiology
pub_type: 临床试验,杂志文章
doi:10.1016/j.jelectrocard.2011.08.012
更新日期:2012-05-01 00:00:00
abstract::A rigorous mathematical analysis of Electrocardiogram (ECG) data is presented in this paper, as a decision support system for ECG interpretation. The mathematical analysis: provides a new insight to the ECG data, provides flexibility for future understanding of the heart system or the ECG, and avoids the need of measu...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:
更新日期:1987-10-01 00:00:00
abstract:OBJECTIVE:To determine the effect of exercise and heart rate on the early repolarization (ER) pattern; focusing on the new criteria for identification of ER. METHODS:The ECG measurements on the terminal QRS notch or slur found in early repolarization were quantitated before, during and after exercise; specifically: (i...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/j.jelectrocard.2019.03.005
更新日期:2019-01-01 00:00:00
abstract::Congenital long QT syndrome (LQTS) is known to be a critical syndrome associated with a bizarre T wave, prolonged QT interval, and ventricular arrhythmias and is followed by syncope and/or sudden death. Body surface mapping, especially QRST isointegral departure mapping, was used after exercise to assess exercise-indu...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/j.jelectrocard.2005.02.005
更新日期:2005-07-01 00:00:00
abstract::A device has been developed which can be used in conjunction with a direct-writing electrocardiograph to record the high frequency electrocardiogram (ECG) including notches and slurs in the waveform. The device operates on the principle of temporarily storing the QRS complex and then reproducing it at a rate 10 times ...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/s0022-0736(75)80054-9
更新日期:1975-07-01 00:00:00
abstract::Using standard biopolar, temporary pacing catheters, thresholds were measured in four configurations: (1) bipolar (distal electrode negative, proximal electrode positive); (2) distal unipolar (distal electrode negative, right arm electrode positive); (3) proximal unipolar (proximal electrode negative, right arm electr...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/s0022-0736(76)80077-5
更新日期:1976-04-01 00:00:00
abstract:PURPOSE:Recent research has established that a tall R-wave in V1 indicates lateral wall involvement in non-anterior wall myocardial infarction (MI). The objective of this study was to assess the value of the admission electrocardiogram (ECG) to predict R-waves and consequently lateral wall damage in the late phase of n...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/j.jelectrocard.2015.02.005
更新日期:2015-07-01 00:00:00
abstract::We report a case of an outpatient cardiac arrest due to ventricular fibrillation and resuscitated with external automated defibrillator shocks in which acute amiodarone infusion unmasked a Brugada phenotype electrocardiographic pattern. Possible interferences by this drug and suitable therapeutic actions are discussed...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/j.jelectrocard.2012.02.005
更新日期:2012-07-01 00:00:00
abstract::This study employs a bifurcation analysis approach to elucidate the effect of the key ion channels on cardiac arrhythmias and thereby explain the efficacy of antiarrhythmic drugs in controlling arrhythmias. The model used for the analysis contains the key ion channels involved in the ventricular action potential--fast...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/s0022-0736(95)80055-7
更新日期:1995-01-01 00:00:00
abstract:BACKGROUND:It is not always feasible to use standard electrode placement for limb leads when recording the 12-lead electrocardiogram (ECG). Other electrode placements have been accepted during monitoring. Nonstandard electrode positions, however, fail to produce waveforms identical to those recorded from the distal lim...
journal_title:Journal of electrocardiology
pub_type: 杂志文章
doi:10.1016/j.jelectrocard.2010.11.012
更新日期:2011-03-01 00:00:00