Abstract:
RATIONALE AND OBJECTIVES:The aim of this study was to present and evaluate a fully automated system for emphysema quantification on low-dose computed tomographic images. The platform standardizes emphysema measurements against changes in the reconstruction algorithm and slice thickness. MATERIALS AND METHODS:Emphysema was quantified in 149 patients using a fully automatic, in-house developed software (the Robust Automatic On-Line Pulmonary Helper). The accuracy of the system was evaluated against commercial software, and its reproducibility was assessed using pairs of volume-corrected images taken 1 year apart. Furthermore, to standardize quantifications, the effect of changing the reconstruction parameters was modeled using a nonlinear fit, and the inverse of the model function was then applied to the data. The association between quantifications and pulmonary function testing was also evaluated. The accuracy of the in-house software compared to that of commercial software was measured using Spearman's rank correlation coefficient, the mean difference, and the intrasubject variability. Agreement between the methods was studied using Bland-Altman plots. To assess the reproducibility of the method, intraclass correlation coefficients and Bland-Altman plots were used. The statistical significance of the differences between the standardized data and the reference data (soft-tissue reconstruction algorithm B40f; slice thickness, 1 mm) was assessed using a paired two-sample t test. RESULTS:The accuracy of the method, measured as intrasubject variability, was 3.86 mL for pulmonary volume, 0.01% for emphysema index, and 0.39 Hounsfield units for mean lung density. Reproducibility, assessed using the intraclass correlation coefficient, was >0.95 for all measurements. The standardization method applied to compensate for variations in the reconstruction algorithm and slice thickness increased the intraclass correlation coefficients from 0.87 to 0.97 and from 0.99 to 1.00, respectively. The correlation of the standardized measurements with pulmonary function testing parameters was similar to that of the reference (for the emphysema index and the obstructive subgroup: forced expiratory volume in 1 second, -0.647% vs -0.615%; forced expiratory volume in 1 second/forced vital capacity, -0.672% vs -0.654%; and diffusing capacity for carbon monoxide adjusted for hemoglobin concentration, -0.438% vs -0.523%). CONCLUSIONS:The new emphysema quantification method presented in this report is accurate and reproducible and, thanks to its standardization method, robust to changes in the reconstruction parameters.
journal_name
Acad Radioljournal_title
Academic radiologyauthors
Ceresa M,Bastarrika G,de Torres JP,Montuenga LM,Zulueta JJ,Ortiz-de-Solorzano C,Muñoz-Barrutia Adoi
10.1016/j.acra.2011.06.015subject
Has Abstractpub_date
2011-11-01 00:00:00pages
1382-90issue
11eissn
1076-6332issn
1878-4046pii
S1076-6332(11)00343-6journal_volume
18pub_type
杂志文章abstract::The outbreak of 2019 novel coronavirus (2019-nCoV) pneumonia was reported in Wuhan, Hubei Province, China in December 2019 and has spread internationally. This article discusses how radiology departments can most effectively respond to this public health emergency. ...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2020.02.003
更新日期:2020-04-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The purpose of this study was to assess resident scores on the American College of Radiology (ACR) In-Training Examination and on the written American Board of Radiology (ABR) Examination relative to attendance at and timing of the Armed Forces Institute of Pathology (AFIP) Radiologic Pathology...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/s1076-6332(00)80525-5
更新日期:2000-09-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To evaluate the effect of automatic tube current modulation on radiation dose and image quality for low tube voltage computed tomography (CT) angiography. MATERIALS AND METHODS:An anthropomorphic phantom was scanned with a 64-section CT scanner using following tube voltages: 140 kVp (Protocol ...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2009.02.021
更新日期:2009-08-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To compare the performance of two shortened breast magnetic resonance imaging (MRI) protocols to a standard MRI protocol for breast cancer screening. MATERIALS AND METHODS:In this Health Insurance Portability and Accountability Act compliant, institutional review board-approved pilot study, th...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2015.06.004
更新日期:2015-09-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:We investigated the influence of muscular activity and regional body temperature changes on the accumulation of intravenously (i.v.) administered, dextran-coated superparamagnetic iron oxide (SPIO) particles in the lymph nodes of rats. METHODS:Four groups of rats (N = 21) were used. Five rats ...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/s1076-6332(96)80193-0
更新日期:1996-08-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The lack of understanding of the real costs (not charge) of delivering healthcare services poses tremendous challenges in the containment of healthcare costs. In this study, we applied an established cost accounting method, the time-driven activity-based costing (TDABC), to assess the costs of ...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2016.11.001
更新日期:2017-02-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Tumor grading of nonfunctional pancreatic neuroendocrine tumors (NF-pNETs) determines the choice of clinical treatment and management. The pathological grade of pancreatic neuroendocrine tumors is usually assessed on postoperative specimens. The goal of our study is to establish a tumor grade (...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2020.01.002
更新日期:2020-12-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To investigate residents' knowledge of adverse effects of ionizing radiation, frequency of their education on radiation safety, and their use of radioprotective equipment. MATERIALS AND METHODS:Residents from 15/16 residency programs at Emory University were asked to complete a resident radiat...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2014.01.016
更新日期:2014-07-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The aim of the study is to evaluate the effectiveness of an Emergency Radiology (ER) Core Curriculum training module and a Digital Imaging and Communications in Medicine (DICOM)-based interactive examination system to prepare first-year (postgraduate year 2 [PGY-2]) radiology residents and asse...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2006.02.057
更新日期:2006-06-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The purpose of this prospective randomized study was to compare the long-term instructional effectiveness of a computer-based radiology multimedia textbook (MMTB) with that of a traditional lecture. METHODS:Volunteer faculty/fellows and residents were randomly assigned to either a computer-bas...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/s1076-6332(05)80731-7
更新日期:1994-11-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To quantify the use of Diagnostic Certainty Phrases (DCP) in radiology reports, including DCPs with good agreement (including "diagnostic of," "unlikely" and "represents") in connoting degree of certainty between providers based on previous studies; and to assess whether modality, presence of a...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2018.10.017
更新日期:2019-09-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:We sought to quantify patient preferences for mild, moderate, and severe low back pain via time-tradeoff analysis and utility measurement. MATERIALS AND METHODS:Forty-one patients being treated for low back pain in a tertiary care teaching hospital participated in the study. Patients were aske...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2004.11.031
更新日期:2005-04-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To determine if combination of washout and noncontrast data from delayed adrenal computed tomography (CT) improves diagnostic performance, and demonstration of an optimizing analytical framework. MATERIALS AND METHODS:This retrospective study consisted of 97 adrenal lesions, in 96 patients, wi...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2017.12.005
更新日期:2018-07-01 00:00:00
abstract::We discuss the benefits of maintaining an active, rigorous, and highly structured grand rounds (GR) program in an academic radiology department. These benefits include education for faculty (continuing medical education), fellows, and residents and a venue for building collaboration and camaraderie within the departme...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2012.08.003
更新日期:2012-11-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Total kidney volume is an important biomarker for the evaluation of autosomal dominant polycystic kidney disease progression. In this study, we present a novel approach for automated segmentation of polycystic kidneys from non-contrast-enhanced computed tomography (CT) images. MATERIALS AND ME...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2017.11.015
更新日期:2018-07-01 00:00:00
abstract:RATIONALE AND OBJECTIVE:The aim of the study was to survey misfiled cases in a picture archiving and communication system environment at two hospitals and to demonstrate the potential usefulness of an automated patient recognition method for posteroanterior chest radiographs based on a template-matching technique desig...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2004.11.008
更新日期:2005-01-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:A national needs assessment of radiology program directors was performed to characterize grand rounds (GR) programs, assess the perceived educational value of GR programs, and determine the impact of the recent economic downturn on GR. MATERIALS AND METHODS:A 28-question survey was developed q...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2011.08.015
更新日期:2011-12-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:This study aimed to determine the value of dual-energy thoracic radiography in the diagnosis of pneumothorax considering the reader's experience. MATERIALS AND METHODS:Forty patients with a suspected pneumothorax, imaged with dual-energy chest radiographs, were divided into two groups: those w...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2017.06.015
更新日期:2018-01-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:We examined whether high-resolution computed tomography (HRCT) would detect and quantify induced airway changes in asthmatic volunteers. METHODS:We performed pulmonary function tests and HRCT on eight asthmatic adults and two nonasthmatic control adults under three conditions: baseline, after ...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/s1076-6332(05)80671-3
更新日期:1996-05-01 00:00:00
abstract::Cryoablation is one of several minimally invasive treatments that may be suitable for a targeted treatment of prostate cancer. Because efficacy is improved when a sufficiently cold end temperature is reached, the purpose of this work was to demonstrate an image-based thermometry method that could provide temperature m...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2005.06.006
更新日期:2005-09-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Mammographic density and parenchymal patterns have been shown to be related to the risk of developing breast cancer. Thus, computerized texture analysis of breast parenchymal patterns on mammograms may be useful in assessing breast cancer risk. MATERIALS AND METHODS:A comparative evaluation wa...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2005.03.069
更新日期:2005-07-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:In clinical guideline or criteria development processes, such as those used in developing American College of Radiology Appropriateness Criteria (ACR AC), experts subjectively evaluate benefits and risks associated with imaging tests and make complex decisions about imaging recommendations. The...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2017.01.001
更新日期:2017-05-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To determine the diagnostic accuracy of stereotactically and sonographically guided core biopsy (CB) for the diagnosis of nonpalpable breast lesions. MATERIALS AND METHODS:Twenty-two institutions enrolled 2,403 women who underwent imaging-guided fine needle aspiration followed by imaging-guide...
journal_title:Academic radiology
pub_type: 临床试验,杂志文章,多中心研究,随机对照试验
doi:10.1016/s1076-6332(03)00510-5
更新日期:2004-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:A method is presented to track guide wires during endovascular interventions under X-ray fluoroscopy. Accurate guide wire tracking can be used to improve guide wire visualization in the low quality fluoroscopic images, and to estimate the position of the guide wire in world coordinates for navi...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/s1076-6332(03)00539-7
更新日期:2003-12-01 00:00:00
abstract::A group of experts on very large databases, quantitative imaging, data format standards development, image management and communications, and related technologies for cancer imaging met at a recent workshop sponsored by the BIP and discussed the key issues confronting this field. The BIP received recommendations regar...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/s1076-6332(03)80126-5
更新日期:2003-07-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The segmentation of airways from CT images is a critical first step for numerous virtual bronchoscopic (VB) applications. Automatic or semiautomatic methods are necessary, since manual segmentation is prohibitively time consuming. The methods must be robust and operate within a reasonable time ...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/s1076-6332(03)80517-2
更新日期:2002-10-01 00:00:00
abstract:PURPOSE:Coronary computed tomographic angiography (CTA) is a valuable tool for assessing coronary artery disease (CAD). Although statin use is widely recommended for persons with diabetes older than age 40, little is known about the presence and severity of CAD in younger patients with diabetes mellitus (DM). We evalua...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2012.03.013
更新日期:2012-07-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:A statistical based iterative single-photon emission-computed tomography (SPECT) reconstruction algorithm (OSEM) modeling the depth-dependent collimator response in three dimensions has recently been introduced (OSEM3D). The aim of this study was to evaluate the axial shape fidelity of OSEM3D i...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2005.12.004
更新日期:2006-04-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Dual-energy computed tomography (DECT) and ultrasound are both used to assess gouty arthritis. The present study was designed to compare the diagnostic accuracy of DECT and ultrasound in detecting monosodium urate (MSU) crystal deposition in various joints. MATERIALS AND METHODS:This study enr...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2015.08.010
更新日期:2015-12-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Obscure gastrointestinal bleeding (OGIB) is the bleeding from the gastrointestinal tract without definite source that persists and recurs after a negative endoscopic evaluation. The study aimed to systematically evaluate the diagnostic accuracy of computed tomography enterography on OGIB detect...
journal_title:Academic radiology
pub_type: 杂志文章,meta分析,评审
doi:10.1016/j.acra.2017.09.001
更新日期:2018-02-01 00:00:00