Abstract:
PURPOSE:To evaluate the feasibility and sensitivity of the 3D-reading of fecal-tagging CT colonography (CTC) with a novel structure-analysis electronic cleansing (SAEC) in detecting colorectal flat lesions in comparison with a cleansed 3D reading with Viatronix V3D Colon system (V3D) and primary uncleansed 2D reading (2D). MATERIALS AND METHODS:Forty CTC cases with flat lesions were retrospectively observed. The Subjects from a multicenter clinical trial underwent cathartic bowel preparation with orally administrated barium-based fecal-tagging. Sixty-nine flat lesions were confirmed using colonoscopy and histopathology as a reference standard. The results from SAEC reading were compared with those of prospective V3D and 2D readings. RESULTS:Overall detection sensitivity with SAEC was 52% (36/69), which was statistically higher than that of 32% (22/69) and 29% (20/69) with V3D and 2D readings, respectively (p<0.05). The sensitivities in detecting not-on-fold flat lesions were 63% (24/38), 45% (17/38), and 42% (16/38) with SAEC, V3D, and 2D readings, respectively; whereas those of on-fold flat lesions were 39% (12/31), 16% (5/31), and 13% (4/31), respectively. None of the eight flat lesions (2-9mm) at cecum was detected by any of the three reading methods. Excluding the flat lesions at cecum, the sensitivity with SAEC for detecting flat lesion ≥4mm increased to 84% (31/37). CONCLUSIONS:The fecal-tagging CTC with structure-analysis electronic cleansing could yield a high sensitivity for detecting flat lesions ≥4mm. The not-on-fold flat lesions were detected with higher sensitivity than on-fold flat lesions.
journal_name
Eur J Radioljournal_title
European journal of radiologyauthors
Xu Y,Cai W,Nappi J,Yoshida Hdoi
10.1016/j.ejrad.2011.04.051subject
Has Abstractpub_date
2012-08-01 00:00:00pages
1712-6issue
8eissn
0720-048Xissn
1872-7727pii
S0720-048X(11)00458-Xjournal_volume
81pub_type
杂志文章,多中心研究abstract:PURPOSE:To evaluate the imaging pattern of pancreaticobiliary lesions in patients with treated type 1AIP, to determine the incidence of disease relapse and malignancy, and to identify the risk factors. METHOD:The institutional review board approval was acquired. All patients gave written informed consent. From a prosp...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2019.108673
更新日期:2019-11-01 00:00:00
abstract:AIM:We investigated the evaluability of left atrial appendix by dual source coronary CT angiography and analyzed morphologic features. MATERIALS AND METHODS:We included 106 consecutive patients who underwent coronary CT angiography for various indications. Technical parameters were slice thickness 0.6 mm, reconstructi...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2010.11.008
更新日期:2011-12-01 00:00:00
abstract:BACKGROUND AND PURPOSE:Incidentally discovered adrenal masses are commonly seen with high resolution diagnostic imaging performed for indications other than adrenal disease. Although the majority of these masses are benign and non-secretory, their unexpected discovery prompts further biochemical and often repeated imag...
journal_title:European journal of radiology
pub_type: 杂志文章,评审
doi:10.1016/j.ejrad.2010.12.060
更新日期:2012-03-01 00:00:00
abstract:OBJECTIVES:To compare the assessment of global and regional left ventricular (LV) function using 64-slice multislice computed tomography (MSCT), 2D echocardiography (2DE) and cardiac magnetic resonance (CMR). METHODS:Thirty-two consecutive patients (mean age, 56.5+/-9.7 years) referred for evaluation of coronary arter...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2007.03.008
更新日期:2008-01-01 00:00:00
abstract::Contrast-enhanced sonography is a widely available imaging modality for the diagnosis of pancreatic diseases. With this procedure, pancreatic tumours can be differentiated better. Furthermore, contrast-enhanced sonography produces good results in the staging of acute pancreatitis severity, especially in the detection ...
journal_title:European journal of radiology
pub_type: 杂志文章,评审
doi:10.1016/j.ejrad.2007.06.035
更新日期:2007-11-01 00:00:00
abstract:OBJECTIVE:To investigate the value of dual-energy MDCT in spectral imaging in the differential diagnosis of chronic mass-forming chronic pancreatitis (CMFP) and pancreatic ductal adenocarcinoma (PDAC) during the arterial phase (AP) and the pancreatic parenchymal phase (PP). MATERIALS AND METHODS:Thirty five consecutiv...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2015.09.023
更新日期:2015-12-01 00:00:00
abstract::Teleradiology is probably the most successful eHealth service available today. Its business model is based on the remote transmission of radiological images (e.g. X-ray and CT-images) over electronic networks, and on the interpretation of the transmitted images for diagnostic purpose. Two basic service models are comm...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2009.10.018
更新日期:2010-01-01 00:00:00
abstract:OBJECTIVES:To compare the image quality between virtual monochromatic spectral (VMS) images obtained using 320-row detector CT and polychromatic 120-kVp images reconstructed with or without iterative reconstruction using various phantom sizes. MATERIALS AND METHODS:Torso phantoms simulating three patient sizes and con...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2017.08.016
更新日期:2017-10-01 00:00:00
abstract:PURPOSE:To evaluate the influence of radiation dose settings and reconstruction algorithms on the measurement accuracy and reproducibility of semi-automated pulmonary nodule volumetry. MATERIALS AND METHODS:CT scans were performed on a chest phantom containing various nodules (10 and 12mm; +100, -630 and -800HU) at 12...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2014.01.025
更新日期:2014-05-01 00:00:00
abstract::Bone marrow oedema is associated with a wide variety of pathological processes including both benign and malignant bone tumours. This imaging finding in relation to intraosseous tumours can aid in providing a more focused differential diagnosis. In this review, we will discuss the MR imaging of bone marrow oedema surr...
journal_title:European journal of radiology
pub_type: 杂志文章,评审
doi:10.1016/j.ejrad.2008.01.052
更新日期:2008-07-01 00:00:00
abstract:OBJECTIVE:To introduce a new 3D magnetic resonance neurography (MRN) method involving a paramagnetic contrast-based T2 effect coupled with an advanced 3D heavily T2W SPACE-STIR high resolution imaging sequence that would enhance the contrast between nervous tissue and surrounding tissues. METHODS:Thirty subjects (aver...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2015.12.001
更新日期:2016-03-01 00:00:00
abstract:PURPOSE:To investigate radiation exposure in computed tomography (CT)-guided interventions, to establish reference levels for exposure, and to discuss strategies for dose reduction. MATERIALS AND METHODS:We analyzed 1576 consecutive CT-guided procedures in 1284 patients performed over 4.5 years, including drainage pla...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2013.08.035
更新日期:2013-12-01 00:00:00
abstract:OBJECTIVE:To compare fast T1-weighted fluid-attenuated inversion recovery (FLAIR) and T1-weighted turbo spin-echo (TSE) imaging of the degenerative disc disease of the lumbar spine. MATERIALS AND METHODS:Thirty-five consecutive patients (19 females, 16 males; mean age 41 years, range 31-67 years) with suspected degene...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2004.09.009
更新日期:2005-08-01 00:00:00
abstract:OBJECTIVE:The objective of this study was to establish the cut-off value of the signal intensity drop on chemical shift magnetic resonance imaging (MRI) with appropriate sensitivity and specificity to differentiate osteoporotic from neoplastic wedging of the spine. PATIENTS AND METHODS:All patients with wedging of ver...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2008.06.019
更新日期:2009-10-01 00:00:00
abstract::Several diffusion tensor imaging tractography (DTT) have been adopted to construct the living human brain corticospinal tract. In this Note, we applied method "A" as recently described and used by "Lin CC, Tsai MY, Lo YC, et al. Reproducibility of corticospinal diffusion tensor tractography innormal subjects and hemip...
journal_title:European journal of radiology
pub_type: 评论,信件
doi:10.1016/j.ejrad.2014.05.022
更新日期:2014-09-01 00:00:00
abstract:OBJECTIVES:To retrospectively evaluate the effects of a speckle reduction algorithm on radiologists' diagnosis of malignant and benign breast lesions on ultrasound (US) images. METHODS:Using a database of 603 breast (US) images of 211 cases (109 benign lesions and 102 malignant ones), the original and speckle-reduced ...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2009.10.001
更新日期:2010-07-01 00:00:00
abstract:OBJECTIVE:The purpose of this work is to prospectively evaluate high resolution ultrasonography with graded compression in the ability to detect Crohn's disease of the small bowel (CDSB) together with its complications and activity signs, compared with enteroclysis, CT and immunoscintigraphy in the mirror of the final ...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/s0720-048x(00)00240-0
更新日期:2000-09-01 00:00:00
abstract:PURPOSE:To evaluate the correlation between quantitative dual energy CT and perfusion CT measurements in rabbit VX2 liver tumors. MATERIALS AND METHODS:This study was approved by the institutional animal care and use committee at our institution. Nine rabbits with VX2 liver tumors underwent contrast-enhanced dual ener...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2011.06.057
更新日期:2012-08-01 00:00:00
abstract::A 73-year-old woman with a large esophagorespiratory fistula underwent bronchoscopy and computed tomographic (CT) virtual endoscopy before stenting. Noninvasive CT virtual endoscopy showed the large fistula, and the CT findings agreed with the bronchoscopic findings. ...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/s0720-048x(99)00100-x
更新日期:2000-04-01 00:00:00
abstract::Patients with extended vascular anomalies may suffer from significant aesthetic and functional impairment and represent a challenge to therapeutic planning, which is best met by an interdisciplinary concept. In agreement with the International Society for the Study of Vascular Anomalies (ISSVA), vascular lesions are c...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2010.04.009
更新日期:2010-07-01 00:00:00
abstract::A case of beta-thalassemia intermedia with spinal cord compression due to extramedullary hematopoiesis, which was successfully treated by blood transfusion, is presented. Emphasis was made on the MRI appearance of extramedullary hematopoiesis on different pulse sequences. The theories that aimed to explain the involve...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/s0720-048x(99)00122-9
更新日期:2000-07-01 00:00:00
abstract:PURPOSE:Within five years after presentation 50-60% of patients with chronic limb-threatening ischemia (CLI) have died or had an amputation. We assessed the predictive value of lower extremity arterial calcification on computed tomography (CT) characteristics on both 7-years amputation-free survival and 10-years all-ca...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2020.109305
更新日期:2020-11-01 00:00:00
abstract:OBJECTIVE:Using an anthropomorphic phantom, we have investigated the feasibility of digital tomosynthesis (DT) of flat-panel detector (FPD) radiography to reduce radiation dose for sinonasal examination compared to multi-detector computed tomography (MDCT). MATERIALS AND METHODS:A female Rando phantom was scanned cove...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2011.03.064
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:To determine the relationship between hemoglobin levels and attenuation measurements of the superior sagittal sinus (SSS) on unenhanced computed tomography (UECT). Secondly, to determine if SSS attenuation values are normally distributed such that measurements below and above certain thresholds are suggestive o...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2009.04.068
更新日期:2010-09-01 00:00:00
abstract:OBJECTIVE:A software program was developed simulating a compartmental model of blood circulation based on differential equations. The aim of this study was to compare software-simulated levels of hepatic enhancement with the true values in patients and to test how many patients reach the simulated hepatic enhancement l...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/S0720-048X(03)00217-1
更新日期:2004-07-01 00:00:00
abstract::Pediatric projection imaging differs from imaging of the adult patient. Children are smaller, more radiosensitive, and less compliant than their adult counterparts. Their characteristics affect the way projection imaging is practiced and how dose is optimized. Computed radiography (CR) and digital radiography (DR) hav...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2009.03.003
更新日期:2009-11-01 00:00:00
abstract:PURPOSE:To evaluate two different iodine concentrations of contrast material for detecting hypervascular hepatocellular carcinomas (HCCs) in cirrhotic liver by multi-detector row helical CT (MDCT) when a fixed contrast material volume and injection rate is used. MATERIALS AND METHODS:Institutional Review Board approva...
journal_title:European journal of radiology
pub_type: 杂志文章,随机对照试验
doi:10.1016/j.ejrad.2010.10.006
更新日期:2011-12-01 00:00:00
abstract:OBJECTIVE:To estimate a frequency of obstetric anal sphincters defects in women after vaginal delivery. METHODS:The study included 102 women, aged from 16 to 40 years (mean age 28.6 years). 28 women had perineal lacerations of 3rd and 4th degree. 22 women had instrumental delivery. Anal endosonography was performed on...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2009.10.008
更新日期:2011-04-01 00:00:00
abstract:OBJECTIVE:To assess the diagnostic accuracy of multi-detector-row computed tomography (MDCT) for the detection of ampullary adenomas or adenocarcinomas in situ. MATERIALS AND METHODS:We retrospectively reviewed 21 computed tomography (CT) images from 20 patients with ampullary tumors, and 22 CT images from 22 patients...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2010.10.022
更新日期:2011-12-01 00:00:00
abstract:PURPOSE:The purpose of this study was to evaluate inter- and intra-rater reproducibility in volume assessment using cardiac magnetic resonance imaging (CMRI). METHODS:Twenty-five healthy volunteers and 106 patients were included into this retrospective study and received CMRI. The patients were divided in three groups...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2007.09.035
更新日期:2008-12-01 00:00:00