Quantitative assessment of the superior sagittal sinus on unenhanced computed tomography.

Abstract:

PURPOSE:To determine the relationship between hemoglobin levels and attenuation measurements of the superior sagittal sinus (SSS) on unenhanced computed tomography (UECT). Secondly, to determine if SSS attenuation values are normally distributed such that measurements below and above certain thresholds are suggestive of pathology, such as anemia or acute venous thrombosis respectively. METHODS:Institutional review board approval was obtained for retrospective review of adult patients having both an UECT head examination and a complete blood count within 24 h of the scan. A cohort of 151 consecutive patients formed the study sample (76 males and 75 females, 17-91 years of age with a mean of 61). The dorsal aspect of the SSS was divided into upper, middle and lower segments. Using freehand and circle region of interest (ROI) techniques, a total of six attenuation measurements were obtained from each patient. Next, statistical analyses were preformed to assess the correlation between Hgb levels and attenuation values, and distribution curves were plotted to assess the normal range of SSS attenuation measurements. RESULTS:There is a moderate, yet statistically significant (p<0.001), correlation between Hgb levels and attenuation values in upper, middle and lower segments of the SSS (r=0.487, 0.497 and 0.533 respectively). Based on the calculated mean, median and mode, the attenuation values are normally distributed. When using the freehand ROI technique, the mean value is 50 Hounsfield Units (HU) with a standard deviation (SD) of 7.5. Attenuation values less than 2 SDs (35 HU) are highly suggestive of anemia (specificity and PPV=100%). CONCLUSION:There is a moderate, yet statistically significant, correlation between Hgb levels and attenuation of the SSS on UECT. Furthermore, attenuation measurements of the SSS are normally distributed with a mean of 50 HU and a SD of 7.5. Therefore, quantitative assessment of the SSS may prove useful in the clinical practice of a radiologist; namely, in the diagnosis of anemia and acute venous thrombosis.

journal_name

Eur J Radiol

authors

Fanous R,Leung A,Karlik S

doi

10.1016/j.ejrad.2009.04.068

subject

Has Abstract

pub_date

2010-09-01 00:00:00

pages

336-42

issue

3

eissn

0720-048X

issn

1872-7727

pii

S0720-048X(09)00274-5

journal_volume

75

pub_type

杂志文章
  • Acute pulmonary embolism: comparison of standard axial MDCT with paddlewheel technique.

    abstract:PURPOSE:The purpose of this study was to evaluate the ability of rotated paddlewheel reformations for the detection of central and peripheral pulmonary embolism (PE) compared to standard axial multi detector CT (MDCT) images. MATERIAL AND METHODS:CT scans of 35 patients with PE were reviewed by three independent reade...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2007.05.020

    authors: Brader P,Schoellnast H,Deutschmann HA,Thimary F,Schaffler G,Reittner P

    更新日期:2008-04-01 00:00:00

  • Complete response on MR imaging after neoadjuvant chemotherapy in breast cancer patients: Factors of radiologic-pathologic discordance.

    abstract:PURPOSE:To evaluate the radiologic and clinicopathologic factors in radiologic-pathologic discordance (false-negative results) in breast cancer patients who demonstrate radiologic complete response (rCR) in MR imaging after neoadjuvant chemotherapy (NAC). METHOD:Our institutional review board approved this retrospecti...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2019.06.017

    authors: Choi WJ,Kim HH,Cha JH,Shin HJ,Chae EY,Yoon GY

    更新日期:2019-09-01 00:00:00

  • Virtual non-enhanced dual-energy CT reconstruction may replace true non-enhanced CT scans in the setting of suspected active hemorrhage.

    abstract:OBJECTIVE:To assess virtual non-enhanced dual energy computed tomography (DECT) reconstruction as a potential alternative to true non-enhanced thoracic and abdominal CT scans in patients with suspected active hemorrhage. METHODS AND MATERIALS:Ninety-seven consecutive patients with suspected active bleeding, who underw...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2018.10.026

    authors: Walter SS,Schneeweiß S,Maurer M,Kraus MS,Wichmann JL,Bongers MN,Lescan M,Bamberg F,Othman AE

    更新日期:2018-12-01 00:00:00

  • Dual-modality PET/CT instrumentation-today and tomorrow.

    abstract::Positron emission tomography (PET) has proven to be a clinically valuable imaging modality, particularly for oncology staging and therapy follow-up. The introduction of combined PET/CT imaging has helped address challenging imaging situations when anatomical information on PET-only was inadequate for accurate lesion l...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2009.12.021

    authors: Lonsdale MN,Beyer T

    更新日期:2010-03-01 00:00:00

  • Adrenal cortical tumours in children.

    abstract::Adrenal cortical tumours are uncommon in children. For many years it was thought that the majority were malignant with a poor prognosis. Pathological criteria for malignancy are unreliable for these tumours in childhood. The radiological findings in seven children are presented. Large tumour size (> 6 cm diameter) and...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/0720-048x(94)90334-4

    authors: Boothroyd AE,Dicks-Mireaux C,Malone M

    更新日期:1994-08-01 00:00:00

  • Comparison of transient arterial occlusion and muscle exercise provocation for assessment of perfusion reserve in skeletal muscle with real-time contrast-enhanced ultrasound.

    abstract:OBJECTIVE:Contrast-enhanced ultrasound (CEUS) is able to quantify muscle perfusion and changes in perfusion due to muscle exercise in real-time. However, reliable measurement of standardized muscle exercise is difficult to perform in clinical examinations. We compared perfusion reserve assessed by CEUS after transient ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2009.11.014

    authors: Krix M,Krakowski-Roosen H,Amarteifio E,Fürstenberger S,Delorme S,Kauczor HU,Weber MA

    更新日期:2011-06-01 00:00:00

  • Percutaneous sclerotherapy of a giant benign renal cyst with alcohol.

    abstract::We report a case of giant, benign renal cyst that was treated with percutaneous aspiration and sclerotherapy using 95% alcohol. A seven French catheter was inserted into the cyst under ultrasonographic and fluoroscopic guidance, and was then left in place to drain the cyst contents. Approximately 4 l of fluid was drai...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/s0720-048x(01)00280-7

    authors: Bozkurt FB,Boyvat F,Tekin I,Aytekin C,Coskun M,Ozkardes H

    更新日期:2001-10-01 00:00:00

  • The parasitic blood supply of abdominal masses.

    abstract::Many lesions, and particularly hyper-vascularized ones, acquire an aberrant blood supply. These parasitic vascular supplies are defined as tumour vascularizations derived from neighbouring organs or structures, and supplement the normal blood supply of the diseased organ. Their existence is essential for the angiograp...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:

    authors: Lamarque JL,Triby X,Bruel JM,Rouanet JP,Lopez P

    更新日期:1981-05-01 00:00:00

  • MR imaging of acute pancreatitis: correlation of abdominal wall edema with severity scores.

    abstract:OBJECTIVE:To study MRI findings of abdominal wall edema (AWE) in acute pancreatitis as well as correlations between AWE and the severity of acute pancreatitis according to the MR severity index (MRSI) and the Acute Physiology And Chronic Healthy Evaluation III (APACHE III) scoring system. MATERIALS AND METHODS:A total...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2012.04.005

    authors: Yang R,Jing ZL,Zhang XM,Tang W,Xiao B,Huang XH,Yang L,Feng ZS

    更新日期:2012-11-01 00:00:00

  • Reject analysis: a pilot programme for image quality management.

    abstract::The radiographic film wastage and the different parameters affecting this wastage were analysed for a 9-week period at a 600-bed University Hospital. An overall reject rate of 7.6% was found. The different reasons for rejection were evaluated, while retake rate, relation between working experience of the personnel, am...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/0720-048x(91)90067-6

    authors: Arvanitis TN,Parizel PM,Degryse HR,De Schepper AM

    更新日期:1991-05-01 00:00:00

  • The latest in ultrasound: three-dimensional imaging. Part II.

    abstract:INTRODUCTION:The three-dimensional (3D) reconstruction of ultrasound images has become a widespread option in ultrasound equipment. Specific softwares have become available and 3D reconstruction feasible since the early 1990s, particularly since 1994. POSSIBLE CLINICAL APPLICATIONS:Several clinical applications are fe...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/s0720-048x(98)00077-1

    authors: Campani R,Bottinelli O,Calliada F,Coscia D

    更新日期:1998-05-01 00:00:00

  • Visualization of morphological parenchymal changes in emphysema: comparison of different MRI sequences to 3D-HRCT.

    abstract:PURPOSE:Thin-section CT is the modality of choice for morphological imaging the lung parenchyma, while proton-MRI might be used for functional assessment. However, the capability of MRI to visualize morphological parenchymal alterations in emphysema is undetermined. Thus, the aim of the study was to compare different M...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2008.09.029

    authors: Ley-Zaporozhan J,Ley S,Eberhardt R,Kauczor HU,Heussel CP

    更新日期:2010-01-01 00:00:00

  • Evaluation of small (

    abstract:PURPOSE:To evaluate the detectability and signal intensities of small (

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2007.02.023

    authors: Tonan T,Fujimoto K,Azuma S,Ono N,Matsushita S,Kojiro M,Hayabuchi N

    更新日期:2007-10-01 00:00:00

  • Cisterna chyli in patients with malignancy--influence of cardiovascular disease on the prevalence of the cisterna.

    abstract:UNLABELLED:The purpose of this study was to investigate the potential correlation between the presence and size of the cisterna chyli (CC) on computed tomography (CT) and the presence of cardiovascular disease. MATERIALS AND METHODS:Out of a 3000-patient cohort 2599 patients who received a CT examination of the chest ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2010.02.009

    authors: Feuerlein S,Stolz J,Muche R,Hetzel M,Klass O,Brambs HJ,Pauls S

    更新日期:2011-08-01 00:00:00

  • Primary extranodal Non-Hodgkin lymphoma of the orbital and paranasal region-a retrospective study.

    abstract:PURPOSE:Primary extranodal lymphomas of the orbit and sinonasal region are rare and occur almost only as Non-Hodgkin lymphoma (NHL). The purpose of this study was to determine the frequency of different subtypes of NHL in these regions and to describe their radiological features. MATERIALS AND METHODS:Between January ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2012.03.036

    authors: Sandner A,Surov A,Bach AG,Kösling S

    更新日期:2013-02-01 00:00:00

  • Usefulness of the long-axis and short-axis reformatted images of multidetector-row CT in evaluating T-factor of the surgically resected pancreaticobiliary malignancies.

    abstract:PURPOSE:To evaluate the diagnostic efficacy of curved planar reformations along the duct (long-axis CPR) and series of reformations perpendicular to the duct (short-axis MPR) in evaluating T-factors of pancreaticobiliary malignancy. MATERIALS AND METHODS:Twenty-five patients with surgically proven pancreaticobiliary m...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2007.01.022

    authors: Kakihara D,Yoshimitsu K,Irie H,Tajima T,Asayama Y,Hirakawa M,Ishigami K,Yamaguchi K,Taketomi A,Nishihara Y,Honda H

    更新日期:2007-07-01 00:00:00

  • Computational radiology in skeletal radiography.

    abstract::Recent years have brought rapid developments in computational image analysis in musculo-skeletal radiology. Meanwhile the algorithms have reached a maturity that makes initial clinical use feasible. Applications range from joint space measurement to erosion quantification, and from fracture detection to the assessment...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2009.05.053

    authors: Peloschek P,Nemec S,Widhalm P,Donner R,Birngruber E,Thodberg HH,Kainberger F,Langs G

    更新日期:2009-11-01 00:00:00

  • Dynamic sequential computed tomography in abdominal tumours. Some aspects for differential diagnosis.

    abstract::Dynamic CT in combination with intravenous bolus injection of contrast material provides a study of the pharmacokinetics in great vessels as well as in tissues. If the enhancement in the region of interest is plotted against time, the time-enhancement diagrams obtained reflect the contrast material passage mathematica...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:

    authors: Metzger HO,Hübener KH

    更新日期:1985-02-01 00:00:00

  • Clinical feasibility of 2D dynamic sagittal HASTE flexion-extension imaging of the cervical spine for the assessment of spondylolisthesis and cervical cord impingement.

    abstract:PURPOSE:To assess the utility of a 2D dynamic HASTE sequence in assessment of cervical spine flexion-extension, specifically (1) comparing dynamic spondylolisthesis to radiographs and (2) assessing dynamic contact upon or deformity of the cord. METHODS:Patients with a dynamic flexion-extension sagittal 2D HASTE sequen...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2020.109447

    authors: Burke CJ,Samim M,Alizai H,Sanchez J,Kingsbury D,Babb JS,Walter WR

    更新日期:2021-01-01 00:00:00

  • Regional changes in brain perfusion during brain maturation measured non-invasively with Arterial Spin Labeling MRI in neonates.

    abstract:PURPOSE:The purpose of this study was to evaluate if non-invasive Arterial Spin Labeling MR imaging can be used to assess changes in brain perfusion with age which reflect neonatal brain development. For this purpose regional perfusion values obtained with ASL MR imaging were evaluated as a function of postmenstrual ag...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2012.10.013

    authors: De Vis JB,Petersen ET,de Vries LS,Groenendaal F,Kersbergen KJ,Alderliesten T,Hendrikse J,Benders MJ

    更新日期:2013-03-01 00:00:00

  • Predictive value of small ulcers in the evolution of acute type B intramural hematoma.

    abstract:OBJECTIVE:To assess the long-term evolution and predictive factors of type B intramural hematoma (IMH). MATERIAL AND METHODS:34 patients (33 men), mean age: 67 years (47-87) diagnosed with type B IMH by computed tomography (CT) and followed up clinically and by CT yearly. Mean follow-up was 5.9 years (2-13 years). Two...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2011.04.055

    authors: Sebastià C,Evangelista A,Quiroga S,Cuellar H,Aguilar R,Muntanyà X

    更新日期:2012-07-01 00:00:00

  • Influence of radiation dose and iterative reconstruction algorithms for measurement accuracy and reproducibility of pulmonary nodule volumetry: A phantom study.

    abstract:PURPOSE:To evaluate the influence of radiation dose settings and reconstruction algorithms on the measurement accuracy and reproducibility of semi-automated pulmonary nodule volumetry. MATERIALS AND METHODS:CT scans were performed on a chest phantom containing various nodules (10 and 12mm; +100, -630 and -800HU) at 12...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2014.01.025

    authors: Kim H,Park CM,Song YS,Lee SM,Goo JM

    更新日期:2014-05-01 00:00:00

  • Non-invasive assessment of congenital pulmonary vein stenosis in children using cardiac-non-gated CT with 64-slice technology.

    abstract:BACKGROUND:Management of congenital pulmonary vein stenosis is a diagnostic challenge. Echocardiography may be insufficient and thus cardiac catheterization remains the reference standard in this setting. The aim of the study was to investigate the accuracy of cardiac-non-gated CT using 64-slice technology in detecting...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2008.02.006

    authors: Ou P,Marini D,Celermajer DS,Agnoletti G,Vouhé P,Sidi D,Bonnet D,Brunelle F

    更新日期:2009-06-01 00:00:00

  • Diffusion-weighted imaging properties of uterine fibroids pre- and post-uterine fibroid embolisation.

    abstract:OBJECTIVE:To determine the change in apparent diffusion coefficient (ADC) of uterine fibroids following uterine fibroid embolisation (UFE), and if the ADC change correlates with either volume loss or degree of contrast enhancement post-UFE. MATERIALS AND METHODS:This study was approved by our institutional review boar...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2014.05.031

    authors: Kirpalani A,Chong J,Yang N,Jenkins SJ,Nisenbaum R,Prabhudesai V,Anthwal S,Colak E

    更新日期:2014-09-01 00:00:00

  • Single-energy low-voltage arterial phase MDCT scanning increases conspicuity of adenocarcinoma of the pancreas.

    abstract:PURPOSE:To test a single-energy low-voltage CT protocol for pancreatic adenocarcinoma. METHODS AND MATERIALS:A total of 30 patients with pathology-proven pancreatic adenocarcinoma underwent 64-row MDCT with arterial phase at 80 kV and were compared to a similar group of 30 patients scanned with a 120 kV protocol. Scan...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2013.12.022

    authors: Zamboni GA,Ambrosetti MC,Guariglia S,Cavedon C,Pozzi Mucelli R

    更新日期:2014-03-01 00:00:00

  • 'The Closer'-percutaneous vascular suture device: evaluation of safety and performance in neuroangiography.

    abstract:OBJECTIVE:To evaluate the use of the suture mediated vascular closure device concerning practicability and safety in clinical angiography practice. MATERIAL AND METHODS:One hundred and seventeen patients (59 female, 58 male, mean age 40.9+/-13.4) underwent percutaneous closure of common femoral arterial puncture sites...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/s0720-048x(03)00048-2

    authors: Henk CB,Grampp S,Heimberger K,Czerny C,Schindler E,Mostbeck GH

    更新日期:2003-12-01 00:00:00

  • Non-invasive diagnostic assessment of extensive vertebral artery tortuosity with enlargement of the intervertebral foramen.

    abstract::Two cases with an incidental finding of a widened intervertebral foramen due to extensive tortuosity of the vertebral artery are presented. Computed tomography angiography and magnetic resonance imaging/magnetic resonance angiography (MRA) both proved to be useful as non-invasive techniques to provide the diagnosis. I...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/s0720-048x(98)00164-8

    authors: Vanrietvelde F,Lemmerling M,de Rooy J,Seynaeve P,Uytterhaegen P,Van de Walle R,Kunnen M

    更新日期:1999-12-01 00:00:00

  • Dual-energy CT angiography of abdomen with routine concentration contrast agent in comparison with conventional single-energy CT with high concentration contrast agent.

    abstract:PURPOSE:To compare the quantitative and subjective image quality in abdominal angiography between dual-energy CT (DECT) at the routine concentration of iodinated contrast agent (300mg/mL) and conventional 120-kVp single-energy CT (SECT) at the high concentration of contrast agent (370mg/mL). MATERIALS AND METHODS:Abdo...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2014.11.025

    authors: He J,Wang Q,Ma X,Sun Z

    更新日期:2015-02-01 00:00:00

  • A novel parameter by EFOV US for the quantification and the distinction of physiological amount of scrotal fluid and hydrocele: ratio of testis volume/scrotum volume.

    abstract:OBJECTIVE:To determine the limits for the amount of tunical fluid enough to be termed as hydrocele by using extended-field of view US technology and to define hydrocele for the first time with standard numerical criteria. METHODS:A total of 60 patients were evaluated in this prospective study. Group 1 consisted of 20 ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2007.02.001

    authors: Turgut AT,Ozden E,Unsal A,Koşar P,Coşkun ZU,Koşar U

    更新日期:2007-09-01 00:00:00

  • Percutaneous treatment of benign bile duct strictures.

    abstract:PURPOSE:To evaluate long-term results of treatment of benign bile duct strictures. MATERIALS AND METHODS:From February 1994 to November 2005, 21 patients (9 men, 12 women) with median age of 50.6 years (range 27-77 years) were indicated to percutaneous treatment of benign bile duct stricture. Stricture of hepatic duct...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2007.01.032

    authors: Köcher M,Cerná M,Havlík R,Král V,Gryga A,Duda M

    更新日期:2007-05-01 00:00:00