Single-energy low-voltage arterial phase MDCT scanning increases conspicuity of adenocarcinoma of the pancreas.

Abstract:

PURPOSE:To test a single-energy low-voltage CT protocol for pancreatic adenocarcinoma. METHODS AND MATERIALS:A total of 30 patients with pathology-proven pancreatic adenocarcinoma underwent 64-row MDCT with arterial phase at 80 kV and were compared to a similar group of 30 patients scanned with a 120 kV protocol. Scans were compared for quantitative image parameters (attenuation and standard deviation in the pancreas, tumor, aorta), CTDI and DLP using an unpaired t-test. Image noise values for each protocol (SD of the psoas) were compared using an unpaired t-test. Effective dose was calculated for each protocol. CNR (=conspicuity/SDnoise) and FOM (CNR2/ED) were calculated. The Catphan600 phantom was used to evaluate image non-uniformity, noise, spatial resolution, and low contrast detectability. RESULTS:Mean patient weight was 68 kg in the study group and 73 kg in the control group (p=0.0355), while patient diameters at the celiac axis were not significantly different. Mean attenuation was significantly higher at 80 kV in the aorta (517.5±116.4 vs 290.3±76.4 HU) and normal pancreas (154.0±39.95 vs 90.02±19.01 HU) (all p<0.0001), while no significant difference was observed for adenocarcinoma (61.43±35.61 vs 47.45±18.95; p=n.s.). CTDI and DLP were significantly lower at 80 kV (6.00±0.90 mGy vs 10.24±2.93 mGy, and 180.4±35.49 mGy cm vs 383.8±117 mGy cm, respectively; all p<0.0001). Tumor conspicuity (HUpancreas-HUtumor) was significantly higher at 80 kV (94.2±39.3 vs 39.5±22 HU; p<0.0001). Mean image noise was significantly higher at 80kV (28.32±10.06 vs 19.7±7.1HU; p<0.0001). Effective dose was significantly lower at 80 kV (1.984±0.39 vs 5.75±1.75 mSv; p<0.0001). The total DLP for the exam was 1024±31.86 mGy cm for the 80 kV protocol and 1357±62.60 mGy cm for the 120 kV protocol (p<0.0001). Phantoms showed higher non-uniformity, slightly higher noise, slightly lower MTF (50%) and slightly higher percentage contrast for the 80 kV protocol. CONCLUSION:Single-source 80 kV pancreatic phase scanning results in higher conspicuity of pancreatic adenocarcinoma and FOM and in significant dose reduction while maintaining acceptable image quality.

journal_name

Eur J Radiol

authors

Zamboni GA,Ambrosetti MC,Guariglia S,Cavedon C,Pozzi Mucelli R

doi

10.1016/j.ejrad.2013.12.022

subject

Has Abstract

pub_date

2014-03-01 00:00:00

pages

e113-7

issue

3

eissn

0720-048X

issn

1872-7727

pii

S0720-048X(13)00665-7

journal_volume

83

pub_type

杂志文章
  • The blood flow channel index as novel predictor of abdominal aortic aneurysm impending rupture based on the intraluminal thrombus angio-CT study.

    abstract:OBJECTIVE:In this study the hypothesis that the thickness of the thinnest part of the thrombus, combined with bleeding into the intraluminal thrombus (ILT), is associated with a possible higher risk of abdominal aortic aneurysm (AAA) rupture was investigated, independently of aneurysm diameter, by using angio-CT. This ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2014.12.022

    authors: Wiernicki I,Szumilowicz P,Kazimierczak A,Falkowski A,Rutkowski D,Gutowski P

    更新日期:2015-04-01 00:00:00

  • The Chiari III malformation: an unusual and asymptomatic variant in an 11-year old child.

    abstract::Chiari III malformation is an extremely rare condition, and is characterized by the hindbrain herniation into a low occipital or high cervical encephalocele together with the pathologic and imaging features of the Chiari II malformation. In this report, an unusual variant of the Chiari III malformation was diagnosed i...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/s0720-048x(01)00334-5

    authors: Sirikci A,Bayazit YA,Bayram M

    更新日期:2001-09-01 00:00:00

  • Legionnaire's pneumonia: is there really an interstitial disease?

    abstract:OBJECTIVE:Legionella pneumonia is usually classified as "atypical pneumonia", which suggests a predominance of interstitial patterns in chest X-rays. Based on a selection of recent clinical cases and a brief review of the literature, the aim of the study is to clarify, how far the actual radiological findings would be ...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2006.08.020

    authors: Godet C,Frat JP,Le Moal G,Roblot F,Michalakis G,Cabon E,Tasu JP

    更新日期:2007-01-01 00:00:00

  • Differentiation between benign and malignant colon tumors using fast dynamic gadolinium-enhanced MR colonography; a feasibility study.

    abstract:BACKGROUND:Colorectal cancer will present itself as a bowel obstruction in 16-23% of all cases. However, not all obstructing tumors are malignant and the differentiation between a benign and a malignant tumor can be difficult. The purpose of our study was to determine whether fast dynamic gadolinium-enhanced MR imaging...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2009.03.033

    authors: Achiam MP,Andersen LP,Klein M,Løgager V,Chabanova E,Thomsen HS,Rosenberg J

    更新日期:2010-06-01 00:00:00

  • Degeneration and height of cervical discs classified from MRI compared with precise height measurements from radiographs.

    abstract:STUDY DESIGN:Descriptive study comparing MRI classifications with measurements from radiographs. OBJECTIVES:1. Define the relationship between MRI classified cervical disc degeneration and objectively measured disc height. 2. Assess the level of inter- and intra-observer errors using MRI in defining cervical disc dege...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2005.02.005

    authors: Kolstad F,Myhr G,Kvistad KA,Nygaard OP,Leivseth G

    更新日期:2005-09-01 00:00:00

  • ¹⁸F-fluorodeoxyglucose uptake on positron emission tomography in mucinous adenocarcinoma.

    abstract:BACKGROUND:The prognostic value of maximum standardized uptake value (maxSUV) on (18)F-fluorodeoxyglucose positron emission tomography (FDG-PET) is known for localized pulmonary adenocarcinoma, which is most commonly non-mucinous adenocarcinoma. We examined the validity of thin-section computed tomography (TS-CT) and F...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2013.07.028

    authors: Murakami S,Saito H,Karino F,Kondo T,Oshita F,Ito H,Nakayama H,Yokose T,Yamada K

    更新日期:2013-11-01 00:00:00

  • Value of gadoxetic acid-enhanced and diffusion-weighted MR imaging in evaluation of hepatocellular carcinomas with atypical enhancement pattern on contrast-enhanced multiphasic MDCT in patients with chronic liver disease.

    abstract:OBJECTIVE:The purpose of this study was to investigate the value of enhancement kinetics and ancillary imaging findings on gadoxetic acid-enhanced and diffusion-weighted (DW) MR imaging for diagnosing hepatocellular carcinomas (HCCs) without the typical enhancement pattern on contrast-enhanced multiphasic MDCT in patie...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2014.12.023

    authors: Kim HS,Kim SH,Kang TW,Song KD,Choi D,Park CK

    更新日期:2015-04-01 00:00:00

  • Role of combined DWIBS/3D-CE-T1w whole-body MRI in tumor staging: Comparison with PET-CT.

    abstract:OBJECTIVES:To assess the diagnostic performance of whole-body magnetic resonance imaging (WB-MRI) by diffusion-weighted whole-body imaging with background body signal suppression (DWIBS) in malignant tumor detection and the potential diagnostic advantages in generating fused DWIBS/3D-contrast enhanced T1w (3D-CE-T1w) i...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2011.08.005

    authors: Manenti G,Cicciò C,Squillaci E,Strigari L,Calabria F,Danieli R,Schillaci O,Simonetti G

    更新日期:2012-08-01 00:00:00

  • Image quality and radiation dose of single heartbeat 640-slice coronary CT angiography: a comparison between patients with chronic atrial fibrillation and subjects in normal sinus rhythm by propensity analysis.

    abstract:OBJECTIVES:To evaluate image quality and radiation dose of single heartbeat 640-slice coronary CT angiography (CCTA) in patients with chronic Atrial Fibrillation (cAF) in comparison with subjects in normal sinus rhythm. METHODS:A cohort of 71 patients with cAF was matched with 71 subjects in normal sinus rhythm (NSR) ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2014.11.035

    authors: Di Cesare E,Gennarelli A,Di Sibio A,Felli V,Splendiani A,Gravina GL,Masciocchi C

    更新日期:2015-04-01 00:00:00

  • Presurgical fMRI evaluation of cerebral reorganization and motor deficit in patients with tumors and vascular malformations.

    abstract::The aim of this fMRI study was to evaluate the motor reorganization (cerebral plasticity) and the risk of motor deficit in patients presenting with tumors and vascular malformations, within the framework of their pre-surgical planning. Functional MR imaging data was obtained from 17 patients. Ten patients (seven with ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/s0720-048x(02)00083-9

    authors: Baciu M,Le Bas JF,Segebarth C,Benabid AL

    更新日期:2003-05-01 00:00:00

  • Focal liver lesion detection and characterization: comparison of non-contrast enhanced and SPIO-enhanced diffusion-weighted single-shot spin echo echo planar and turbo spin echo T2-weighted imaging.

    abstract:PURPOSE:To compare lesion conspicuity and image quality between single-shot spin echo echo planar imaging (SS SE-EPI) before, immediately and 5min after intravenous (IV) injection of superparamagnetic iron oxide (SPIO) for detecting and characterizing focal liver lesions (FLLs). MATERIALS AND METHODS:Twenty-five patie...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2008.09.005

    authors: Coenegrachts K,Matos C,ter Beek L,Metens T,Haspeslagh M,Bipat S,Stoker J,Rigauts H

    更新日期:2009-12-01 00:00:00

  • Minimally invasive therapy for the treatment of breast tumours.

    abstract::Minimally invasive therapy has been explored as a potential means of treating breast tumours with minimal disruption to adjacent soft tissues. The purpose of this is to facilitate improved cosmesis and to offer treatment to women who are unfit for surgery. A number of treatment modalities including thermal therapies (...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/s0720-048x(02)00019-0

    authors: Hall-Craggs MA,Vaidya JS

    更新日期:2002-04-01 00:00:00

  • The measurement of the rotational deformities with computed tomography in femoral shaft fractures of the children treated with early spica cast.

    abstract::Twenty-eight children with femoral shaft fractures, treated with early spica cast, were evaluated with computed tomography (CT), for their femoral shaft rotational deformities. The femoral torsion angles were measured on both sides. If the torsion angle of the fractured side was more than the other side, it was consid...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/s0720-048x(02)00256-5

    authors: Bulut S,Bulut O,Taş F,Eğilmez H

    更新日期:2003-07-01 00:00:00

  • The effective and collective dose to patients undergoing abdominopelvic and trunk computed tomography examinations: A Belgian multicentre study.

    abstract:OBJECTIVES:This study aims to evaluate the radiation exposure to patients undergoing an abdominopelvic or a chest and abdominopelvic (trunk) CT examination and to assess compliance to imaging referral guidelines. METHODS:To this end, 357 standard abdominopelvic and trunk CT scans were collected from 8 Belgian institut...

    journal_title:European journal of radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1016/j.ejrad.2018.12.019

    authors: De Roo B,Stichelbaut N,Hoste P,Verstraete K,Bacher K

    更新日期:2019-02-01 00:00:00

  • Diagnostic image workstations for PACS.

    abstract::Image workstations will be the 'window' to the complex infrastructure of a PACS with its intertwined image modalities (image sources, image data bases and image processing devices) and data processing modalities (patient data bases, departmental and hospital information systems). They will serve for user-to-system dia...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/0720-048x(90)90146-3

    authors: Meyer-Ebrecht D,Fasel B,Dahm M,Kaupp A,Schilling T

    更新日期:1990-05-01 00:00:00

  • Performance of computer-aided detection applied to full-field digital mammography in detection of breast cancers.

    abstract:OBJECTIVE:The aim of this retrospective study was to evaluate performance of computer-aided detection (CAD) with full-field digital mammography (FFDM) in detection of breast cancers. MATERIALS AND METHODS:CAD was retrospectively applied to standard mammographic views of 127 cases with biopsy proven breast cancers dete...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2009.08.024

    authors: Sadaf A,Crystal P,Scaranelo A,Helbich T

    更新日期:2011-03-01 00:00:00

  • Lung parenchyma changes in ankylosing spondylitis: demonstration with high resolution CT and correlation with disease duration.

    abstract:OBJECTIVE:To analyze the spectrum of the lung parenchyma changes in ankylosing spondylitis (AS) with high resolution computed tomography (HRCT) and correlate the findings with disease duration. MATERIAL AND METHODS:Twenty patients (18 male, 2 female) with the diagnosis of AS according to New York criteria were include...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/s0720-048x(02)00052-9

    authors: Senocak O,Manisali M,Ozaksoy D,Sevinç C,Akalin E

    更新日期:2003-02-01 00:00:00

  • Diaphragmatic hernia: diagnostic approaches with review of the literature.

    abstract::Because surgical repair is indicated for the treatment of diaphragmatic hernia (DH), preoperative imaging of the diaphragmatic defect, hernia content, and associated complications with other organ's pathologies is important. While various techniques can be used on imaging of DHs, selection of the most effective but th...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2004.09.008

    authors: Eren S,Ciriş F

    更新日期:2005-06-01 00:00:00

  • The use of coronary stent in hepatic artery stenosis after orthotopic liver transplantation.

    abstract:PURPOSE:This retrospective study was undertaken to evaluate the effectiveness of coronary stent placement in hepatic artery stenosis after orthotopic liver transplantation (OLT). MATERIALS AND METHODS:Of 430 consecutive adult orthotopic liver transplant recipients between November 2003 and September 2005, 17 had hepat...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2006.06.008

    authors: Huang M,Shan H,Jiang Z,Li Z,Zhu K,Guan S,Qian J,Chen G,Lu M,Yang Y

    更新日期:2006-12-01 00:00:00

  • Endorectal 3D T2-weighted 1mm-slice thickness MRI for prostate cancer staging at 1.5Tesla: should we reconsider the indirects signs of extracapsular extension according to the D'Amico tumor risk criteria?

    abstract:PURPOSE:To evaluate the accuracy of a 3D-endorectal 1mm-thick slices MRI acquisition for local staging of low, intermediate and high D'Amico risk prostate cancer (PCa). MATERIALS AND METHODS:178 consecutive patients underwent a multiparametric MRI protocol prior to radical prostatectomy (RP). T2W images were acquired ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2011.06.056

    authors: Cornud F,Rouanne M,Beuvon F,Eiss D,Flam T,Liberatore M,Zerbib M,Delongchamps NB

    更新日期:2012-04-01 00:00:00

  • Etiology of spontaneous pneumothorax in 105 HIV-infected patients without highly active antiretroviral therapy.

    abstract:INTRODUCTION:Spontaneous pneumothorax (SP) is a frequent complication in non-treated HIV-infected patients as a complication of opportunistic infections and tumours. OBJECTIVE:To analyse the aetiology of SP in non-treated HIV patients. PATIENTS AND METHODS:Observational study of SP cases observed in a cohort of 9831 ...

    journal_title:European journal of radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1016/j.ejrad.2008.05.003

    authors: Rivero A,Perez-Camacho I,Lozano F,Santos J,Camacho A,Serrano A,Cordero E,Jiménez F,Torres-Tortosa M,Torre-Cisneros J,Andalusian Group for the Study of Infectious Diseases (GAEI).

    更新日期:2009-08-01 00:00:00

  • Using multi-detector-row CT to diagnose ampullary adenoma or adenocarcinoma in situ.

    abstract:OBJECTIVE:To assess the diagnostic accuracy of multi-detector-row computed tomography (MDCT) for the detection of ampullary adenomas or adenocarcinomas in situ. MATERIALS AND METHODS:We retrospectively reviewed 21 computed tomography (CT) images from 20 patients with ampullary tumors, and 22 CT images from 22 patients...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2010.10.022

    authors: Lee M,Kim MJ,Park MS,Choi JY,Chung YE

    更新日期:2011-12-01 00:00:00

  • Triphasic contrast injection improves evaluation of dual energy lung perfusion in pulmonary CT angiography.

    abstract:PURPOSE:Lung perfusion analysis at dual energy CT (DECT) is sensitive to beam hardening artifacts from dense contrast material (CM). We compared two scan and four CM injection protocols in terms of severity of artifacts and attenuation levels in the thoracic vessels. METHODS AND MATERIALS:Data of 120 patients who had ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2010.09.030

    authors: Kerl JM,Bauer RW,Renker M,Weber E,Weisser P,Korkusuz H,Schell B,Larson MC,Kromen W,Jacobi V,Vogl TJ

    更新日期:2011-12-01 00:00:00

  • CT evaluation of the low severity cervical spine trauma: when is the scout view enough?

    abstract::The aim of the current study was to compare the diagnostic information obtained from a helical CT examination in low severity cervical spine trauma with that from a lateral CT scout view. We included alert and clinically stable patients, who had suffered acute blunt trauma of low or moderate severity. Their scout imag...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2009.03.024

    authors: Theocharopoulos N,Chatzakis G,Karantanas A,Chlapoutakis K,Damilakis J

    更新日期:2010-07-01 00:00:00

  • Neurological changes following radiation therapy for head and neck tumours.

    abstract::Radiation therapy is widely used in the treatment of head and neck tumours either as a primary form of treatment or a supplementary modality. Although the benefits of radiation therapy are well established, this treatment modality is not without untoward consequences and complications. The intent of this paper is to h...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/s0720-048x(02)00066-9

    authors: Chong VF,Khoo JB,Chan LL,Rumpel H

    更新日期:2002-11-01 00:00:00

  • MR spectroscopy findings in tuberculous spondylitis; comparison with Modic type-I end-plate changes and metastatic vertebral disease.

    abstract:PURPOSE:To define single-voxel proton magnetic resonance spectroscopy (MRS) findings of vertebral tuberculous spondylitis (TBS), Modic type-I end-plate changes (MTEC) and metastatic vertebral disease (MVD). MATERIALS AND METHODS:Fifteen patients with TBS, 15 with MTEC and 15 with MVD were included. MRS from the diseas...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2008.05.002

    authors: Anik Y,Ciftçi E,Sarisoy HT,Akansel G,Demirci A,Anik I,Buluç L,Ilgazli A

    更新日期:2009-08-01 00:00:00

  • Improving the diagnosis of peripheral arterial disease in below-the-knee arteries by adding time-resolved CT scan series to conventional run-off CT angiography. First experience with a 256-slice CT scanner.

    abstract:PURPOSE:Run-off Computed Tomography Angiography (run-off CTA) of the lower extremities has become the method of choice for the diagnostic imaging of patients suffering from peripheral arterial disease (PAD). However, it remains a challenging radiological examination with a considerable risk of non-diagnostic image qual...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2018.11.030

    authors: Buls N,de Brucker Y,Aerden D,Devos H,Van Gompel G,Boonen PT,Nieboer K,Leiner T,de Mey J

    更新日期:2019-01-01 00:00:00

  • Complete response on MR imaging after neoadjuvant chemotherapy in breast cancer patients: Factors of radiologic-pathologic discordance.

    abstract:PURPOSE:To evaluate the radiologic and clinicopathologic factors in radiologic-pathologic discordance (false-negative results) in breast cancer patients who demonstrate radiologic complete response (rCR) in MR imaging after neoadjuvant chemotherapy (NAC). METHOD:Our institutional review board approved this retrospecti...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2019.06.017

    authors: Choi WJ,Kim HH,Cha JH,Shin HJ,Chae EY,Yoon GY

    更新日期:2019-09-01 00:00:00

  • Contrast ultrasound-guided photothermal therapy using gold nanoshelled microcapsules in breast cancer.

    abstract:OBJECTIVES:The purpose of this study was to test whether dual functional gold nano-shelled microcapsules (GNS-MCs) can be used as an ultrasound imaging enhancer and as an optical absorber for photothermal therapy (PTT) in a rodent model of breast cancer. METHODS:GNS-MCs were fabricated with an inner air and outer gold...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2013.09.010

    authors: Wang S,Dai Z,Ke H,Qu E,Qi X,Zhang K,Wang J

    更新日期:2014-01-01 00:00:00

  • MR imaging of fistula-in-ano.

    abstract::Accurate preoperative assessment of fistula-in-ano is mandatory if the fistula is not to recur. In recent years, MRI has become pre-eminent for fistula assessment and recent studies have shown that not only is MRI more accurate than surgical assessment, but that surgery based on MRI can reduce further disease recurren...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/s0720-048x(03)00162-1

    authors: Halligan S,Buchanan G

    更新日期:2003-08-01 00:00:00