Abstract:
PURPOSE:The purpose of this study was to evaluate inter- and intra-rater reproducibility in volume assessment using cardiac magnetic resonance imaging (CMRI). METHODS:Twenty-five healthy volunteers and 106 patients were included into this retrospective study and received CMRI. The patients were divided in three groups (group I, 80 patients with arrhythmia; group II, 20 patients with cardiomyopathy; group III, 6 patients after correction of septum defects). Therefore, the images were semiautomatically segmented by an experienced and an unexperienced radiologists. The analysis of end-diastolic volume (EDV), end-systolic volume (ESV) and stroke volume (SV) as well as ejection fraction (EF) and myocardial mass (MM) were performed twice by an experienced and an unexperienced radiologists. The intra-class correlation coefficients (ICC) were determined for the evaluation of inter- and intra-rater variance. RESULTS:The intra-rater reproducibility for determination of EF, ESV, EDV and MM was excellent with ICCs ranging from 0.88 to 0.99 (all p<0.001). The inter-observer reproducibility for these parameters was also excellent with ICCs ranging from 0.91 to 0.98 (all p<0.001). The assessment of the SV showed an excellent intra-rater agreement with ICCs of 0.96 and 0.92 (both p<0.001), but only a moderate ICC for the inter-rater reproducibility (0.54, p<0.001). CONCLUSIONS:Our study shows that assessment of cardiac volumes can be performed on CMRIs with an excellent reproducibility by both experienced and unexperienced investigators.
journal_name
Eur J Radioljournal_title
European journal of radiologyauthors
Trieb T,Glodny B,Scheiblhofer M,Wolf C,Metzler B,Pachinger O,Jaschke WR,Schocke MFdoi
10.1016/j.ejrad.2007.09.035subject
Has Abstractpub_date
2008-12-01 00:00:00pages
476-86issue
3eissn
0720-048Xissn
1872-7727pii
S0720-048X(07)00493-7journal_volume
68pub_type
杂志文章abstract:PURPOSE:To assess the effect of parenteral butylscopolamine on magnetic resonance cholangiopancreatography (MRCP) image quality. MATERIALS AND METHODS:The 3D free-breathing respiratory-compensated MRCP images (mean acquisition time 7min) of 94 consecutive non-paired patients (47 with and 47 without 20mg intramuscular ...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2012.11.023
更新日期:2013-04-01 00:00:00
abstract:PURPOSE:To test a single-energy low-voltage CT protocol for pancreatic adenocarcinoma. METHODS AND MATERIALS:A total of 30 patients with pathology-proven pancreatic adenocarcinoma underwent 64-row MDCT with arterial phase at 80 kV and were compared to a similar group of 30 patients scanned with a 120 kV protocol. Scan...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2013.12.022
更新日期:2014-03-01 00:00:00
abstract::Historically varicocele is diagnosed almost exclusively on the left side. The introduction of new imaging techniques has allowed the identification and characterization of right varicocele. This study aims to compare the diagnostic accuracy of various imaging techniques to data obtained using phlebography in the diagn...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2011.05.015
更新日期:2012-09-01 00:00:00
abstract::The aim of this prospective study was to assess the accuracy of modern ultrasonography in diagnostic imaging of meniscal tears. One hundred and sixty menisci were evaluated in 80 patients (42 females, 38 males, mean age=36.2 years, range=16-70 years). Inclusion criteria for the study were twofold: clinical suspicion o...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2011.09.013
更新日期:2012-09-01 00:00:00
abstract::The authors discuss the controversy about mass screening for breast cancer in order to assess the soundness of a nationwide expansion of such programmes. Mass screening is second best because of the failure of prevention, therapeutic progress or ability to target high risk populations, but its efficacy reducing mortal...
journal_title:European journal of radiology
pub_type: 杂志文章,评审
doi:10.1016/s0720-048x(96)01143-6
更新日期:1997-02-01 00:00:00
abstract:OBJECTIVE:To correlate CTA pulmonary artery obstruction scores (OS) with right ventricular dysfunction (RVD) and clinical outcome in patients with acute pulmonary embolism (PE). MATERIALS AND METHODS:In a prospective study of 50 patients (66 ± 12.9 years) with PE pulmonary artery OS (Qanadli, Mastora, and Mastora cent...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2011.08.014
更新日期:2012-10-01 00:00:00
abstract:PURPOSE:The purpose of this retrospective study was to examine the reliability of virtually estimated abdominal blood volume using segmentation from postmortem computed tomography (PMCT) data. MATERIALS AND METHODS:Twenty-one cases with free abdominal blood were investigated by PMCT and autopsy. The volume of the bloo...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2011.09.014
更新日期:2012-09-01 00:00:00
abstract::In this study, we investigated whether assessment of the tumor perfusion by dynamic contrast-enhanced magnetic resonance imaging (DCE MRI) enables to estimate the morphologic grading of renal cell carcinomas. A total of 21 patients with suspected renal cell cancer were examined using a Gadobutrol-enhanced, dynamic sat...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2009.05.042
更新日期:2010-06-01 00:00:00
abstract:OBJECTIVE:To evaluate the technical success and immediate complication rates of temporary internal jugular vein (IJV) haemodialysis catheter placement in normal and high-risk patients. METHODS AND MATERIALS:Two-hundred and twenty temporary internal jugular vein catheters inserted under ultrasound guidance in 172 patie...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2004.10.004
更新日期:2005-07-01 00:00:00
abstract:OBJECTIVE:The purpose of this study was to compare the diagnostic accuracy of 64-slice CT with that of invasive angiography in the detection of graft and/or coronary angioplasty stenosis in children who had undergone coronary artery surgery. POPULATION AND METHODS:Fifteen consecutive children (8 male and 7 female; age...
journal_title:European journal of radiology
pub_type: 临床试验,杂志文章
doi:10.1016/j.ejrad.2008.06.008
更新日期:2009-09-01 00:00:00
abstract:PURPOSE:To determine the relationship between hemoglobin levels and attenuation measurements of the superior sagittal sinus (SSS) on unenhanced computed tomography (UECT). Secondly, to determine if SSS attenuation values are normally distributed such that measurements below and above certain thresholds are suggestive o...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2009.04.068
更新日期:2010-09-01 00:00:00
abstract:PURPOSE:In this study, we aimed to investigate the frequency of SCD and its distribution and relationship with clinical outcomes on thin-section CT of the temporal bone. MATERIALS AND METHODS:Digital temporal bone CT images of 850 consecutive patients (1700 temporal bone CTs, 5100 SCs) who presented with a range of co...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2013.06.022
更新日期:2013-10-01 00:00:00
abstract:PURPOSE:To evaluate the effects of aging on skeletal muscle stiffness in relaxed and contracted status using shear wave elastography (SWE). MATERIALS AND METHODS:A total of 57 participants were enrolled to this institutional review board approved prospective study. Medial head of the gastrocnemius muscle (GM) of all p...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2020.109038
更新日期:2020-07-01 00:00:00
abstract:OBJECTIVES:Breast cancer is the second cause of death in women in Europe and North America. The mortality of this disease can be reduced with effective therapy and regular follow up to detect early recurrence. Tumor markers are sensitive in detecting recurrent or residual disease but imaging is required to customize th...
journal_title:European journal of radiology
pub_type: 杂志文章,多中心研究
doi:10.1016/j.ejrad.2010.04.029
更新日期:2011-12-01 00:00:00
abstract:OBJECTIVES:To analyze the contrast-enhanced ultrasound (CEUS) features of clear cell renal cell carcinoma (CCRCC) in relation to tumor size. MATERIALS AND METHODS:The CEUS appearance of 92 CCRCCs confirmed pathologically were retrospectively analyzed. Tumor size was stratified into six groups with a 1cm interval. For ...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2008.09.030
更新日期:2010-01-01 00:00:00
abstract::When chemical shift selective (CHESS) imaging is used with magnetic resonance imaging (MRI) for simultaneous imaging of both hands for the evaluation of rheumatoid arthritis, the fat suppression effect is poor. We investigated whether these fat-suppressed images using CHESS could be improved with the use of rice pads....
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2011.06.021
更新日期:2012-09-01 00:00:00
abstract:OBJECTIVES:To investigate the acute and repeated pulmonary damage in Sprague-Dawley rats caused by the inhalation of 3-methoxybutyl chloroformate (3-MBCF) using computed tomography (CT), and to correlate these results with those obtained from a pathological study. METHODS:Sixty, 7-week-old rats were exposed to 3-MBCF ...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2006.11.035
更新日期:2007-05-01 00:00:00
abstract:PURPOSE:To determine whether imaging parameters derived from intravoxel incoherent motion (IVIM) diffusion weighted imaging (DWI) vary according to tumor-stroma ratio(TSR) or dominant stroma type of breast cancer. METHODS:We prospectively enrolled 77 patients with breast cancer who underwent IVIM DWI on a 3.0 T MR sca...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2019.108686
更新日期:2019-11-01 00:00:00
abstract:OBJECTIVE:Renal perfusion imaging may provide information about the hemodynamic significance of a renal artery stenosis and could improve noninvasive characterization when combined with angiography. It was proposed previously that diffusion sequences could provide useful perfusion indices based on the intravoxel incohe...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/s0720-048x(97)01161-3
更新日期:1998-02-01 00:00:00
abstract:AIM:The objective of this study is to evaluate the efficacy and safety of image-guided percutaneous splenic interventions as diagnostic or therapeutic procedures. MATERIALS AND METHODS:We performed a retrospective review of our interventional records from July 2001 to June 2006. Ninety-five image-guided percutaneous s...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2007.02.011
更新日期:2007-10-01 00:00:00
abstract::Tuberculosis [TB] of the appendicular skeleton is an uncommon infection caused by the tuberculous bacilli and constitutes only 1-3% of all tuberculosis infections. MR imaging features of tuberculous arthritis include bone marrow oedema, cortical erosions, synovitis, joint effusion, tenosynovitis, soft tissue collectio...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2003.11.003
更新日期:2004-12-01 00:00:00
abstract:OBJECTIVE:To evaluate the use of the suture mediated vascular closure device concerning practicability and safety in clinical angiography practice. MATERIAL AND METHODS:One hundred and seventeen patients (59 female, 58 male, mean age 40.9+/-13.4) underwent percutaneous closure of common femoral arterial puncture sites...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/s0720-048x(03)00048-2
更新日期:2003-12-01 00:00:00
abstract:PURPOSE:The purpose of this study was to evaluate the ability of rotated paddlewheel reformations for the detection of central and peripheral pulmonary embolism (PE) compared to standard axial multi detector CT (MDCT) images. MATERIAL AND METHODS:CT scans of 35 patients with PE were reviewed by three independent reade...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2007.05.020
更新日期:2008-04-01 00:00:00
abstract:OBJECTIVE:To compare fast T1-weighted fluid-attenuated inversion recovery (FLAIR) and T1-weighted turbo spin-echo (TSE) imaging of the degenerative disc disease of the lumbar spine. MATERIALS AND METHODS:Thirty-five consecutive patients (19 females, 16 males; mean age 41 years, range 31-67 years) with suspected degene...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2004.09.009
更新日期:2005-08-01 00:00:00
abstract:PURPOSE:To compare computed tomography (CT) findings in patients with pancreatic metastasis from renal cell carcinoma (pRCC) and patients with hypervascular pancreatic neuroendocrine tumour (pNET) with a focus on the relative percentage washout (RPW). METHODS:We evaluated 16 patients with 37 pRCCs and 28 patients with...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2015.08.007
更新日期:2015-11-01 00:00:00
abstract:INTRODUCTION:Interstitial lung disease occurs frequently in patients with systemic sclerosis (SSc). Quantitative computed tomography (CT) densitometry using the percentile density method may provide a sensitive assessment of lung structure for monitoring parenchymal damage. Therefore, we aimed to evaluate the optimal p...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2015.01.012
更新日期:2015-05-01 00:00:00
abstract::Maple Syrup Urine Disease (MSUD) is an inherited metabolic disorder characterized by a severe, usually lethal, neonatal course in the early stages with pseudotumor cerebri and pathologically documented increased cerebral water content. CT and MRI studies in MSUD are few and the data are overlapping. This study reports...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/0720-048x(92)90089-r
更新日期:1992-05-01 00:00:00
abstract:OBJECTIVES:To compare the image quality between virtual monochromatic spectral (VMS) images obtained using 320-row detector CT and polychromatic 120-kVp images reconstructed with or without iterative reconstruction using various phantom sizes. MATERIALS AND METHODS:Torso phantoms simulating three patient sizes and con...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2017.08.016
更新日期:2017-10-01 00:00:00
abstract:OBJECTIVE:To evaluate brachial plexus MRI accuracy with surgical findings and clinical follow-up as reference standard in a large multicentre study. MATERIALS AND METHODS:The research was approved by the Institutional Review Boards, and all patients provided their written informed consent. A multicentre retrospective ...
journal_title:European journal of radiology
pub_type: 杂志文章,多中心研究
doi:10.1016/j.ejrad.2011.10.007
更新日期:2012-10-01 00:00:00
abstract:PURPOSE:To evaluate treatment decision-making based on susceptibility-weighted imaging (SWI) in patients with hemorrhage after thrombolysis. MATERIALS AND METHODS:One hundred and forty-six patients without intracranial hemorrhage on CT after receiving recombinant tissue plasminogen activator (rt-PA) were allocated to ...
journal_title:European journal of radiology
pub_type: 杂志文章,随机对照试验
doi:10.1016/j.ejrad.2012.08.002
更新日期:2012-12-01 00:00:00