Effect of gravity on drug distribution after port-catheter implantation for hepatic arterial infusion chemotherapy: evaluation of the relationship between the injection posture and intrahepatic perfusion on fused images acquired with a combined SPECT/CT s

Abstract:

RATIONALE AND OBJECTIVES:We evaluated the effect of gravity on intrahepatic perfusion (IHP) in patients with a port-catheter system (PCS) implanted for hepatic arterial infusion chemotherapy (HAIC). Using fused single photon-emission computed tomographic (SPECT)/computed tomographic (CT) images, we compared IHP after the injection of technetium-99m-labeled macroaggregated albumin (Tc-99m-MAA) via a PCS with the patient in the upright and decubitus positions. MATERIALS AND METHODS:We enrolled 27 patients with metastatic carcinoma of the liver who bore an implantable PCS for HAIC. SPECT/CT images were obtained on the third and seventh postimplantation day; 99mTc-MAA (185 MBq) was delivered with the patient in the upright and decubitus positions. We selected four regions of interest (ROIs) on SPECT images of the superior, inferior, anterior, and posterior regions. The anteroposterior and the superoinferior perfusion ratio (AP ratio, SI ratio) were derived from the mean counts in each ROI. Using an unpaired t-test, we compared these ratios after drug delivery in the upright and decubitus injection positions. We also visually compared IHP and classified the distribution of drugs delivered in the upright and decubitus positions on fused images. Moreover, using World Health Organization criteria, we evaluated the therapeutic response by comparing the tumor size on contrast-enhanced CT images obtained before and 3 months after treatment. RESULTS:The SI ratios in the upright and decubitus injection positions were 1.14 and 0.92, respectively; the corresponding AP ratios were 1.47 and 1.73, respectively, indicating that there was no significant difference in these parameters irrespective of the injection position (SI ratio: P = .27, AP ratio: P = .35). However, in 14 of the 27 patients (52%), the visual appearance of IHP was different in the upright and decubitus positions. A change in the location of the catheter side hole when the decubitus was changed to the upright position produced a difference in IHP. Of 13 patients with identical drug distribution in both injection positions, six (46%) manifested a partial response (PR), five (38%) experienced no change (NC), and two (15%) experienced progressive disease (PD). Among the 14 patients with different drug distribution in the two injection positions, four (28%) achieved PR, five (36%) manifested NC, and the other five (36%) had PD. CONCLUSIONS:Although the patient posture affected IHP by changing the position of the infusion catheter side hole in the liver, gravity had no significant effect on IHP in patients bearing an implantable PCS for the delivery of HAIC.

journal_name

Acad Radiol

journal_title

Academic radiology

authors

Tamura Y,Ikeda O,Nakasone Y,Shiraishi S,Tomiguchi S,Yamashita Y,Takamori H,Baba H

doi

10.1016/j.acra.2008.12.004

subject

Has Abstract

pub_date

2009-06-01 00:00:00

pages

662-8

issue

6

eissn

1076-6332

issn

1878-4046

pii

S1076-6332(08)00745-9

journal_volume

16

pub_type

临床试验,杂志文章
  • Pitfalls in RECIST Data Extraction for Clinical Trials: Beyond the Basics.

    abstract::Response Evaluation Criteria in Solid Tumors (RECIST) is a standardized methodology for determining therapeutic response to anticancer therapy using changes in lesion appearance on imaging studies. Many radiologists are now using RECIST in their routine clinical workflow, as part of consultative arrangements, or withi...

    journal_title:Academic radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.acra.2015.01.015

    authors: Abramson RG,McGhee CR,Lakomkin N,Arteaga CL

    更新日期:2015-06-01 00:00:00

  • Reproducibility and repeatability of volumetric measurements for olfactory bulb volumetry: which method is appropriate? An update using 3 Tesla MRI.

    abstract:RATIONALE AND OBJECTIVES:The aim of this study was to compare different sequences for olfactory bulb volumetry using 3-T magnetic resonance imaging, evaluating reproducibility, repeatability, and systematic biases. MATERIALS AND METHODS:Twenty-two volunteers underwent 3-T magnetic resonance imaging of the frontal skul...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2011.02.018

    authors: Burmeister HP,Baltzer PA,Möslein C,Bitter T,Gudziol H,Dietzel M,Guntinas-Lichius O,Kaiser WA

    更新日期:2011-07-01 00:00:00

  • CT detection of serious internal and skeletal injuries in patients with pelvic fractures.

    abstract:RATIONALE AND OBJECTIVES:The purpose of this study was to determine the percentage of patients with known pelvic fractures who have additional findings of intraabdominal injury, as diagnosed at abdominal computed tomography (CT), and to determine if patients with specific types or patterns of fractures are more likely ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/S1076-6332(99)80209-8

    authors: Killeen KL,DeMeo JH

    更新日期:1999-04-01 00:00:00

  • Evaluation of clinical outcomes of antiangiogenic-targeted therapy in patients with pulmonary metastatic renal cell carcinoma using non-contrast-enhanced computed tomography.

    abstract:RATIONALE AND OBJECTIVES:The objective of this study was to assess whether changes to radiographic parameters before and after treatment with antiangiogenic drugs would improve performance in predicting tumor response with non-contrast-enhanced computed tomography (NCECT) compared to Response Evaluation Criteria in Sol...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2014.06.007

    authors: Wu GY,Suo ST,Kong W,Jin D,Zhang J,Xu JR

    更新日期:2014-11-01 00:00:00

  • FDG PET/CT manifestations of hematopoietic malignancies of the breast.

    abstract::Hematopoietic malignancies that can be encountered in the breast include lymphoma, leukemia, and multiple myeloma/plasmacytoma. These are readily imaged via [18]F-fluorodeoxyglucose position emission tomography (PET)/computed tomography (CT) and can manifest as unilateral, bilateral, single, multiple, round/oval masse...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2010.03.023

    authors: Ginat DT,Puri S

    更新日期:2010-08-01 00:00:00

  • Characterization of brain plasticity in schizophrenia using template deformation.

    abstract:RATIONALE AND OBJECTIVE:Abnormal neurodevelopment may play a role in the pathophysiology of schizophrenia. We used deformation-based morphometry to examine voxel-wise age-related changes in patients with schizophrenia compared with healthy brains. MATERIALS AND METHODS:We used a set of skull-stripped brains from an im...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2004.06.009

    authors: Dubb A,Xie Z,Gur R,Gur R,Gee J

    更新日期:2005-01-01 00:00:00

  • Computerized texture analysis of mammographic parenchymal patterns of digitized mammograms.

    abstract:RATIONALE AND OBJECTIVES:Mammographic density and parenchymal patterns have been shown to be related to the risk of developing breast cancer. Thus, computerized texture analysis of breast parenchymal patterns on mammograms may be useful in assessing breast cancer risk. MATERIALS AND METHODS:A comparative evaluation wa...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2005.03.069

    authors: Li H,Giger ML,Olopade OI,Margolis A,Lan L,Chinander MR

    更新日期:2005-07-01 00:00:00

  • DICOM router: an open source toolbox for communication and correction of DICOM objects.

    abstract:RATIONALE AND OBJECTIVE:Today, the exchange of medical images and clinical information is well defined by the digital imaging and communications in medicine (DICOM) and Health Level Seven (ie, HL7) standards. The interoperability among information systems is specified by the integration profiles of IHE (Integrating the...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2004.11.015

    authors: Hackländer T,Kleber K,Martin J,Mertens H

    更新日期:2005-03-01 00:00:00

  • Intrathoracic tracheal volume and collapsibility on inspiratory and end-expiratory ct scans correlations with lung volume and pulmonary function in 85 smokers.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the correlations of tracheal volume and collapsibility on inspiratory and end-expiratory computed tomography (CT) with lung volume and with lung function in smokers. MATERIALS AND METHODS:The institutional review board approved this study at each institution. 85 smokers (mean age 6...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2010.11.005

    authors: Yamashiro T,San José Estépar R,Matsuoka S,Bartholmai BJ,Ross JC,Diaz A,Murayama S,Silverman EK,Hatabu H,Washko GR

    更新日期:2011-03-01 00:00:00

  • Added Value of Bone Subtraction in Dual-energy Digital Radiography in the Detection of Pneumothorax: Impact of Reader Expertise and Medical Specialty.

    abstract:RATIONALE AND OBJECTIVES:This study aimed to determine the value of dual-energy thoracic radiography in the diagnosis of pneumothorax considering the reader's experience. MATERIALS AND METHODS:Forty patients with a suspected pneumothorax, imaged with dual-energy chest radiographs, were divided into two groups: those w...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2017.06.015

    authors: Urbaneja A,Dodin G,Hossu G,Bakour O,Kechidi R,Gondim Teixeira P,Blum A

    更新日期:2018-01-01 00:00:00

  • Automated assessment of renal cortical surface roughness from computerized tomography images and its association with age.

    abstract:RATIONALE AND OBJECTIVES:Nephrosclerosis occurs with aging and is characterized by increased kidney subcapsular surface irregularities at autopsy. Assessments of cortical roughness in vivo could provide an important measure of nephrosclerosis. The purpose of this study was to develop and validate an image-processing al...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2014.05.014

    authors: Duan X,Rule AD,Elsherbiny H,Vrtiska TJ,Avula RT,Alexander MP,Lerman LO,McCollough CH

    更新日期:2014-11-01 00:00:00

  • Establishing a normative atlas of the human lung: computing the average transformation and atlas construction.

    abstract:RATIONALE AND OBJECTIVES:To establish the range of normal for quantitative computed tomography (CT)-based measures of lung structure and function, we seek to develop methods for matching pulmonary structures across individuals and establishing a normative human lung atlas. MATERIALS AND METHODS:In our previous work, w...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2012.04.025

    authors: Li B,Christensen GE,Hoffman EA,McLennan G,Reinhardt JM

    更新日期:2012-11-01 00:00:00

  • Assessment of the renal corticomedullary (23)Na gradient using isotropic data sets.

    abstract:RATIONALE AND OBJECTIVES:(23)Na magnetic resonance imaging is a promising technique for the noninvasive imaging of renal function. Past investigations of the renal corticomedullary [(23)Na] gradient have relied on imaging only in the coronal plane and on cumbersome calculations of [(23)Na], which require the use of ext...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2012.10.009

    authors: Haneder S,Konstandin S,Morelli JN,Schad LR,Schoenberg SO,Michaely HJ

    更新日期:2013-04-01 00:00:00

  • Automated diffusion tensor tractography: implementation and comparison to user-driven tractography.

    abstract:RATIONALE AND OBJECTIVES:Diffusion tensor tractography offers a unique perspective of white matter anatomy, but proper delineation of white matter tracts of interest generally requires the active involvement of an expert neuroanatomist. The investigators describe the implementation of an automated tractographic method ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2012.01.002

    authors: Nucifora PG,Wu X,Melhem ER,Gur RE,Gur RC,Verma R

    更新日期:2012-05-01 00:00:00

  • Evaluation of analgesic effect of equimolar mixture of oxygen and nitrous oxide inhalation during percutaneous biopsy of focal liver lesions: a double-blind randomized study.

    abstract:RATIONALE AND OBJECTIVES:Percutaneous liver biopsy for tumors performed under local anesthesia is still a painful procedure. The aim of this study was to evaluate the patient's reaction and the analgesic efficacy and safety of an equimolar mixture of oxygen and nitrous oxide (EMONO) inhalation. MATERIALS AND METHODS:A...

    journal_title:Academic radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.acra.2011.01.025

    authors: Meskine N,Vullierme MP,Zappa M,d'Assignies G,Sibert A,Vilgrain V

    更新日期:2011-07-01 00:00:00

  • Less Is More: Efficacy of Rapid 3D-T2 SPACE in ED Patients with Acute Atypical Low Back Pain.

    abstract:RATIONALE AND OBJECTIVES:Emergency department (ED) patients with acute low back pain (LBP) may present with ambiguous clinical findings that pose diagnostic challenges to exclude cauda equina syndrome (CES). As a proof of concept, we aimed to determine the efficacy of a rapid lumbar spine (LS) magnetic resonance imagin...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2017.02.011

    authors: Koontz NA,Wiggins RH 3rd,Mills MK,McLaughlin MS,Pigman EC,Anzai Y,Shah LM

    更新日期:2017-08-01 00:00:00

  • Ex Vivo Study of Artifacts Caused by Breast Tissue Markers with Different 1.5 Tesla and 3 Tesla MRI Scanners - A Bicentric Study.

    abstract:RATIONALE AND OBJECTIVES:The purpose of our study was to evaluate magnetic resonance (MR) artifacts related to breast tissue markers in breast imaging procedures. MATERIALS AND METHODS:In this bicentric prospective ex vivo study 10 different commercially available markers were measured in self-made breast phantoms. Br...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2019.12.006

    authors: Puesken M,Unterberg-Buchwald C,Rhiem K,Große Hokamp N,Maintz D,Lotz J,Wienbeck S

    更新日期:2021-01-01 00:00:00

  • CT Radiomics Signature of Tumor and Peritumoral Lung Parenchyma to Predict Nonsmall Cell Lung Cancer Postsurgical Recurrence Risk.

    abstract:RATIONALE AND OBJECTIVES:To estimate recurrence risk after surgery in nonsmall cell lung cancer (NSCLC) patients by employing tumoral and peritumoral radiomics analysis. MATERIALS AND METHODS:One-hundred twenty-four surgically treated stage IA-IIB NSCLC patients' data from 2008 to 2013 were retrospectively collected. ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2019.05.019

    authors: Akinci D'Antonoli T,Farchione A,Lenkowicz J,Chiappetta M,Cicchetti G,Martino A,Ottavianelli A,Manfredi R,Margaritora S,Bonomo L,Valentini V,Larici AR

    更新日期:2020-04-01 00:00:00

  • A Breast Radiology Department-operated, Proactive Same-day Program Identifies Pathogenic Breast Cancer Mutations in Unaffected Women.

    abstract:RATIONALE AND OBJECTIVES:Pathogenic mutations in some genes elevate women's breast cancer risk, necessitating risk-reduction strategies. Unfortunately, women are underscreened for cancer risk, and when identified as potentially high risk, women seldom pursue genetic counseling or testing. To improve cancer risk managem...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2020.12.005

    authors: Loving VA,Luiten RC,Siettmann JM,Mina LA

    更新日期:2020-12-15 00:00:00

  • Tracheobronchial metal stents: effects of covering a bronchial ostium in pigs.

    abstract:RATIONALE AND OBJECTIVES:The purpose of this study was to examine the effects of placing a metal stent across a bronchial orifice. MATERIALS AND METHODS:Nine pigs were used as test subjects, because the right upper lobe bronchus comes directly off the trachea in these animals. One of three types of metal stents was pl...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(99)80253-0

    authors: Bjarnason H,Cahill B,Kløw NE,Han YM,Urness M,Günther R,Gomes MR,Rosenberg MS,Dietz CA Jr,Hunter DW

    更新日期:1999-10-01 00:00:00

  • Subtraction CT angiography of the lower extremities: single volume subtraction versus multi-segmented volume subtraction.

    abstract:RATIONALE AND OBJECTIVES:To validate the hypothesis that a multisegmented approach during subtraction computed tomography (CT) angiography of the lower extremities can improve bone removal efficiency by suppressing regional motion. MATERIALS AND METHODS:The institutional review board of our hospital approved this retr...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2011.01.024

    authors: Lee IJ,Chung JW,Hong H,Yin YH,Kim S,Park EA,Lee W

    更新日期:2011-07-01 00:00:00

  • Detection of ductal carcinoma in situ with mammography, breast specific gamma imaging, and magnetic resonance imaging: a comparative study.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the sensitivity of high-resolution breast-specific gamma imaging (BSGI) for the detection of ductal carcinoma in situ (DCIS) based on histopathology and to compare the sensitivity of BSGI with mammography and magnetic resonance imaging (MRI) for the detection of DCIS. MATERIALS AND...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2007.04.004

    authors: Brem RF,Fishman M,Rapelyea JA

    更新日期:2007-08-01 00:00:00

  • Histological Subtypes Classification of Lung Cancers on CT Images Using 3D Deep Learning and Radiomics.

    abstract:RATIONALE AND OBJECTIVES:Histological subtypes of lung cancers are critical for clinical treatment decision. In this study, we attempt to use 3D deep learning and radiomics methods to automatically distinguish lung adenocarcinomas (ADC), squamous cell carcinomas (SCC), and small cell lung cancers (SCLC) respectively on...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2020.06.010

    authors: Guo Y,Song Q,Jiang M,Guo Y,Xu P,Zhang Y,Fu CC,Fang Q,Zeng M,Yao X

    更新日期:2020-07-01 00:00:00

  • Imaging Hepatocellular Carcinoma with Dynamic CT Before and After Transarterial Chemoembolization: Optimal Scan Timing of Arterial Phase.

    abstract:RATIONALE AND OBJECTIVES:The aim of this study was to determine the optimal arterial phase delay for computed tomography imaging of hepatocellular carcinoma (HCC) before and after transarterial chemoembolization (TACE) using a low iodine dose protocol. MATERIALS AND METHODS:A total of 39 patients with known HCC were i...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2015.08.021

    authors: Saake M,Lell MM,Eller A,Wuest W,Heinz M,Uder M,Schmid A

    更新日期:2015-12-01 00:00:00

  • Imaging Volume Trends and Recovery During the COVID-19 Pandemic: A Comparative Analysis Between a Large Urban Academic Hospital and Its Affiliated Imaging Centers.

    abstract:RATIONALE AND OBJECTIVES:While affiliated imaging centers play an important role in healthcare systems, little is known of how their operations are impacted by the COVID-19 pandemic. Our goal was to investigate imaging volume trends during the pandemic at our large academic hospital compared to the affiliated imaging c...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2020.08.008

    authors: Lang M,Yeung T,Mendoza DP,Flores EJ,Som A,Lang AL,Pianykh OS,Lee SI,Saini S,Little BP,Succi MD

    更新日期:2020-10-01 00:00:00

  • Face of Radiology campaign.

    abstract::This paper outlines the efforts of the American College of Radiology to understand the public perception of radiologists and to effect change in that perception. Through focus groups, in-depth interviews with Capitol Hill staff members, and national telephone surveys, it was found that the public is unaware of the edu...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2009.02.003

    authors: Neiman HL

    更新日期:2009-05-01 00:00:00

  • Reproducibility of five anorectal morphologic measurements in defecography.

    abstract:RATIONALE AND OBJECTIVES:We evaluated the inter- and intraobserver reproducibility of measuring five morphologic parameters of the anorectum in defecography (evacuation proctography). METHODS:Measurements from 42 defecographic studies were statistically analyzed. The parameters measured during resting, squeezing, and ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(05)80719-6

    authors: Yang X,Partanen K,Farin P,Ji H,Soimakallio S

    更新日期:1994-11-01 00:00:00

  • Myocardial Flow Reserve in Coronary Artery Disease with Low Attenuation Plaque: Coronary CTA and 13N-ammonia PET Assessments.

    abstract:RATIONALE AND OBJECTIVES:Physiological measurements from coronary angiography show that coronary stenosis with necrotic core plaque reduces coronary flow reserve (CFR). Myocardial flow reserve (MFR) estimated by 13N-ammonia PET (NH3-PET) is a different index from CFR. Low attenuation plaque (LAP) on coronary CTA (CCTA)...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2020.11.012

    authors: Yamamoto A,Nagao M,Ando K,Nakao R,Sakai A,Watanabe E,Momose M,Sato K,Fukushima K,Sakai S,Hagiwara N

    更新日期:2020-12-03 00:00:00

  • Detection of Extraprostatic Extension of Cancer on Biparametric MRI Combining Texture Analysis and Machine Learning: Preliminary Results.

    abstract:RATIONALE AND OBJECTIVES:Extraprostatic extension of disease (EPE) has a major role in risk stratification of prostate cancer patients. Currently, pretreatment local staging is performed with MRI, while the gold standard is represented by histopathological analysis after radical prostatectomy. Texture analysis (TA) is ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2018.12.025

    authors: Stanzione A,Cuocolo R,Cocozza S,Romeo V,Persico F,Fusco F,Longo N,Brunetti A,Imbriaco M

    更新日期:2019-10-01 00:00:00

  • Nephrogenic systemic fibrosis and management of high-risk patients.

    abstract::The purpose of this work is to provide current information on the rapidly evolving subject of nephrogenic systemic fibrosis (NSF), to establish the radiologic approach to the management of high-risk patients for NSF, and to assess the probabilistic risk of NSF compared to contrast induced nephropathy (CIN), as encount...

    journal_title:Academic radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.acra.2009.01.001

    authors: Altun E,Semelka RC,Cakit C

    更新日期:2009-07-01 00:00:00