Evaluation of the combined use of two different respiratory monitoring systems for 4D CT simulation and gated treatment.

Abstract:

PURPOSE:Two different respiratory monitoring systems (Varian's Real-Time Position Management (RPM) System and Siemens' ANZAI belt Respiratory Gating System) are compared in the context of respiratory signals and 4D CT images that are accordingly reconstructed. This study aims to evaluate the feasibility of combined use of RPM and ANZAI systems for 4DCT simulation and gated radiotherapy treatment, respectively. METHODS:The RPM infrared reflecting marker and the ANZAI belt pressure sensor were both placed on the patient's abdomen during 4DCT scans. The respiratory signal collected by the two systems was synchronized. Fifteen patients were enrolled for respiratory signal collection and analysis. The discrepancies between the RPM and ANZAI traces can be characterized by phase shift and shape distortion. To reveal the impact of the changes in respiratory signals on 4D images, two sets of 4D images based on the same patient's raw data were reconstructed using the RPM and ANZAI data for phase sorting, respectively. The volume of whole lung and the position of diaphragm apex were measured and compared for each respiratory phase. RESULTS:The mean phase shift was measured as 0.2 ± 0.1 s averaged over 15 patients. The shape of the breathing trace was found to be in disagreement. For all the patients, the ANZAI trace had a steeper falloff in exhalation than RPM. The inhalation curve, however, was matched for nine patients, steeper in ANZAI for five patients and steeper in RPM for one patient. For 4D image comparison, the difference in whole-lung volume was about -4% to +4% and the difference in diaphragm position was about -5 mm to +4 mm, compared in each individual phase and averaged over seven patients. CONCLUSIONS:Combined use of one system for 4D CT simulation and the other for gated treatment should be avoided as the resultant gating window would not fully match with each other due to the remarkable discrepancy in breathing traces acquired by the two different surrogate systems.

journal_name

J Appl Clin Med Phys

authors

Liu J,Lin T,Fan J,Chen L,Price R,Ma CC

doi

10.1002/acm2.12434

subject

Has Abstract

pub_date

2018-09-01 00:00:00

pages

666-675

issue

5

issn

1526-9914

journal_volume

19

pub_type

杂志文章
  • A quality assurance tool for helical tomotherapy using a step-wedge phantom and the on-board MVCT detector.

    abstract::The purpose of this study was to develop and evaluate filmless quality assurance (QA) tools for helical tomotherapy by using the signals from the on-board megavoltage computed tomography (MVCT) detector and applying a dedicated step-wedge phantom. The step-wedge phantom is a 15 cm long step-like aluminum block positio...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v13i1.3585

    authors: Althof V,van Haaren P,Westendorp R,Nuver T,Kramer D,Ikink M,Bel A,Minken A

    更新日期:2012-01-05 00:00:00

  • A new frontier of image guidance: Organs at risk avoidance with MRI-guided respiratory-gated intensity modulated radiotherapy: Technical note and report of a case.

    abstract::The case of a 50-year-old man affected by a rhabdomiosarcoma metastatic lesion in the left flank Is reported. The patient was addressed to 50.4 Gy radiotherapy with concomitant chemotherapy in order to locally control the lesion. A Tri-60-Co magnetic resonance hybrid radiotherapy unit was used for treatment delivery a...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12575

    authors: Massaccesi M,Cusumano D,Boldrini L,Dinapoli N,Fionda B,Teodoli S,Azario L,Mattiucci GC,Balducci M,Cellini F,Valentini V

    更新日期:2019-06-01 00:00:00

  • Deep learning and level set approach for liver and tumor segmentation from CT scans.

    abstract:PURPOSE:Segmentation of liver organ and tumors from computed tomography (CT) scans is an important task for hepatic surgical planning. Manual segmentation of liver and tumors is tedious, time-consuming, and biased to the clinician experience. Therefore, automatic segmentation of liver and tumors is highly desirable. It...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.13003

    authors: Alirr OI

    更新日期:2020-10-01 00:00:00

  • Impact of grid size on uniform scanning and IMPT plans in XiO treatment planning system for brain cancer.

    abstract::The main purposes of this study are to: 1) evaluate the accuracy of XiO treatment planning system (TPS) for different dose calculation grid size based on head phan-tom measurements in uniform scanning proton therapy (USPT); and 2) compare the dosimetric results for various dose calculation grid sizes based on real com...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i5.5510

    authors: Rana S,Zheng Y

    更新日期:2015-09-08 00:00:00

  • Hepatic encephalopathy: a neurochemical, neuroanatomical, and neuropsychological study.

    abstract::Hepatic encephalopathy (HE) is normally diagnosed by neuropsychological (NP) tests, which are not very specific and do not reveal the underlying pathology. Magnetic resonance imaging (MRI) and spectroscopy (MRS) of the brain offer alternative and possibly more specific markers for HE. These methods were applied in con...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v7i1.2151

    authors: Binesh N,Huda A,Thomas MA,Wyckoff N,Bugbee M,Han S,Rasgon N,Davanzo P,Sayre J,Guze B,Martin P,Fawzy F

    更新日期:2006-01-01 00:00:00

  • Electrometer offset current due to scattered radiation.

    abstract::Relative dose measurements with small ionization chambers in combination with an electrometer placed in the treatment room ("internal electrometer") show a large dependence on the polarity used. While this was observed previously for percent depth dose curves (PDDs), the effect has not been understood or preventable. ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12458

    authors: Wegener S,Sauer OA

    更新日期:2018-11-01 00:00:00

  • Defining internal target volume using positron emission tomography for radiation therapy planning of moving lung tumors.

    abstract::Substantial disagreement exists over appropriate PET segmentation techniques for non-small cell lung cancer. Currently, no segmentation algorithm explicitly considers tumor motion in determining tumor borders. We developed an automatic PET segmentation model as a function of target volume, motion extent, and source-to...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i1.4600

    authors: Riegel AC,Bucci MK,Mawlawi OR,Ahmad M,Luo D,Chandler A,Pan T

    更新日期:2014-01-06 00:00:00

  • Dose deviations induced by respiratory motion for radiotherapy of lung tumors: Impact of CT reconstruction, plan complexity, and fraction size.

    abstract::A thorax phantom was used to assess radiotherapy dose deviations induced by respiratory motion of the target volume. Both intensity modulated and static, non-modulated treatment plans were planned on CT scans of the phantom. The plans were optimized using various CT reconstructions, to investigate whether they had an ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12847

    authors: Sande EPS,Acosta Roa AM,Hellebust TP

    更新日期:2020-04-01 00:00:00

  • Strategies to optimize stereotactic radiosurgery plans for brain tumors with volumetric-modulated arc therapy.

    abstract:PURPOSE:Prescription practice in SRS plans for brain tumors differs significantly for different modalities. In this retrospective study, the strategies to optimize SRS plans for brain tumors with volumetric arc therapy (VMAT) were presented. METHODS:Fifty clinically treated cases were stratified by the maximum target ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12818

    authors: Wang D,DeNittis A,Hu Y

    更新日期:2020-03-01 00:00:00

  • Assessment of error in the MV radiation isocenter position calculated with the Elekta XVI software.

    abstract::The assessment of the coincidence of imaging and radiation isocenters is an important task of regular quality assurance of medical linear accelerators (linacs) as recommended in national and international quality assurance guidelines. A previously reported investigation of the accuracy of the Elekta XVI software to lo...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12861

    authors: Chojnowski JM,Warr GB,Sykes JR,Thwaites DI

    更新日期:2020-05-01 00:00:00

  • 177 Lutetium SPECT/CT: Evaluation of collimator, photopeak and scatter correction.

    abstract:PURPOSE:The goal of this study was to find the optimal combination of collimator, photopeak and scatter correction for 177 Lutetium (177 Lu) SPECT/CT imaging. METHODS:Three experiments [sphere-to-background ratios (SBR) 50:1, 10:1, and 2:1] were performed with the NEMA Image Quality phantom filled with 177 Lu-trichlor...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12991

    authors: Huizing DMV,Sinaasappel M,Dekker MC,Stokkel MPM,de Wit-van der Veen BJ

    更新日期:2020-09-01 00:00:00

  • Minimizing dose variation from the interplay effect in stereotactic radiation therapy using volumetric modulated arc therapy for lung cancer.

    abstract::It is important to improve the magnitude of dose variation that is caused by the interplay effect. The aim of this study was to investigate the impact of the number of breaths (NBs) to the dose variation for VMAT-SBRT to lung cancer. Data on respiratory motion and multileaf collimator (MLC) sequence were collected fro...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12264

    authors: Kubo K,Monzen H,Tamura M,Hirata M,Ishii K,Okada W,Nakahara R,Kishimoto S,Kawamorita R,Nishimura Y

    更新日期:2018-03-01 00:00:00

  • Method and phantom to study combined effects of in-plane (x,y) and z-axis resolution for 3D CT imaging.

    abstract::Increasingly, the advent of multislice CT scanners, volume CT scanners, and total body spiral acquisition modes has led to the use of Multi Planar Reconstruction and 3D datasets. In considering 3D resolution properties of a CT system it is important to note that both the in-plane (x,y) and z-axis (slice thickness) inf...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i5.6294

    authors: Goodenough D,Levy J,Kristinsson S,Fredriksson J,Olafsdottir H,Healy A

    更新日期:2016-09-08 00:00:00

  • Accuracy of one algorithm used to modify a planned DVH with data from actual dose delivery.

    abstract::Detection and accurate quantification of treatment delivery errors is important in radiation therapy. This study aims to evaluate the accuracy of DVH based QA in quantifying delivery errors. Eighteen previously treated VMAT plans (prostate, H&N, and brain) were randomly chosen for this study. Conventional IMRT deliver...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i5.6344

    authors: Ma T,Podgorsak MB,Kumaraswamy LK

    更新日期:2016-09-08 00:00:00

  • 100 days with scans of the same Catphan phantom on the same CT scanner.

    abstract::Quality control (QC) of CT scanners is important to evaluate image quality and radiation dose. Different QC phantoms for testing image quality parameters on CT are commercially available, and Catphan phantoms are widely used for this purpose. More data from measured image quality parameters on CT are necessary to asse...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12186

    authors: Husby E,Svendsen ED,Andersen HK,Martinsen ACT

    更新日期:2017-11-01 00:00:00

  • An accurate algorithm to match imperfectly matched images for lung tumor detection without markers.

    abstract::In order to locate lung tumors on kV projection images without internal markers, digitally reconstructed radiographs (DRRs) are created and compared with projection images. However, lung tumors always move due to respiration and their locations change on projection images while they are static on DRRs. In addition, gl...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i3.5200

    authors: Rozario T,Bereg S,Yan Y,Chiu T,Liu H,Kearney V,Jiang L,Mao W

    更新日期:2015-05-08 00:00:00

  • Quantitative evaluation of breast density using a dual-energy technique on a digital breast tomosynthesis system.

    abstract:PURPOSE:Although breast density is considered a strong risk factor of breast cancer, its quantitative assessment is difficult. To investigate a quantitative method of measuring breast density using dual-energy mammographic imaging with central digital breast tomosynthesis in physically uniform and nonuniform phantoms. ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12618

    authors: Lu KM,Yeh DM,Cao BH,Lin CY,Liang CY,Zhou YB,Tsai CJ

    更新日期:2019-06-01 00:00:00

  • Automating checks of plan check automation.

    abstract::While a few physicists have designed new plan check automation solutions for their clinics, fewer, if any, managed to adapt existing solutions. As complex and varied as the systems they check, these programs must gain the full confidence of those who would run them on countless patient plans. The present automation ef...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i4.4889

    authors: Halabi T,Lu HM

    更新日期:2014-07-08 00:00:00

  • Effect of audio instruction on tracking errors using a four-dimensional image-guided radiotherapy system.

    abstract::The Vero4DRT (MHI-TM2000) is capable of performing X-ray image-based tracking (X-ray Tracking) that directly tracks the target or fiducial markers under continuous kV X-ray imaging. Previously, we have shown that irregular respiratory patterns increased X-ray Tracking errors. Thus, we assumed that audio instruction, w...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v14i5.4488

    authors: Nakamura M,Sawada A,Mukumoto N,Takahashi K,Mizowaki T,Kokubo M,Hiraoka M

    更新日期:2013-09-06 00:00:00

  • Comparative analysis for renal stereotactic body radiotherapy using Cyberknife, VMAT and proton therapy based treatment planning.

    abstract:PURPOSE:We conducted this dosimetric analysis to evaluate the feasibility of a multi-center stereotactic body radiation therapy (SBRT) trial for renal cell carcinoma (RCC) using different SBRT platforms. MATERIALS/METHODS:The computed tomography (CT) simulation images of 10 patients with unilateral RCC previously trea...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12308

    authors: Baydoun A,Vapiwala N,Ponsky LE,Awan M,Kassaee A,Sutton D,Podder TK,Zhang Y,Dobbins D,Muzic RF Jr,Traughber B,Machtay M,Ellis R

    更新日期:2018-03-14 00:00:00

  • Using mean dose rate to compare relative dosimetric efficiency with respect to source type and source change schedules for HDR brachytherapy.

    abstract::Remote afterloading devices used for high-dose-rate (HDR) brachytherapy may be supplied with different sources, and these sources typically have differing initial source strengths. In addition, the proposed frequency for source changes may also vary, depending upon the source type. Dosimetric parameters unique to each...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v14i6.4239

    authors: Davis SD,Parker W,Evans MD

    更新日期:2013-11-04 00:00:00

  • Evaluation of the RUBY modular QA phantom for planar and non-coplanar VMAT and stereotactic radiations.

    abstract:PURPOSE:This study evaluates the clinical use of the RUBY modular QA phantom for linac QA to validate the integrity of IGRT workflows including the congruence of machine isocenter, imaging isocenter, and room lasers. The results have been benchmarked against those obtained with widely used systems. Additionally, the RU...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.13006

    authors: Poppinga D,Kretschmer J,Brodbek L,Meyners J,Poppe B,Looe HK

    更新日期:2020-10-01 00:00:00

  • Analysis of esophageal-sparing treatment plans for patients with high-grade esophagitis.

    abstract::We retrospectively generated IMRT plans for 14 NSCLC patients who had experienced grade 2 or 3 esophagitis (CTCAE version 3.0). We generated 11-beam and reduced esophagus dose plan types to compare changes in the volume and length of esophagus receiving doses of 50, 55, 60, 65, and 70 Gy. Changes in planning target vo...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v14i4.4248

    authors: Niedzielski J,Bluett JB,Williamson RT,Liao Z,Gomez DR,Court LE

    更新日期:2013-07-08 00:00:00

  • Detection of electron beam energy variations using a computed radiography system.

    abstract::A method to evaluate the electron beam energy constancy by employing the computed radiography (CR) system has been developed. In this method, a right triangular plastic wedge is used to produce a curve of the CR storage phosphor plate signal versus the wedge thickness. The curve, which resembles the percentage depth i...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v10i4.2911

    authors: Cai YC,Ge Y,Bernard D,Turian J,Chu JCH

    更新日期:2009-10-15 00:00:00

  • MAGAT gel and EBT2 film-based dosimetry for evaluating source plugging-based treatment plan in Gamma Knife stereotactic radiosurgery.

    abstract::This work illustrates a procedure to assess the overall accuracy associated with Gamma Knife treatment planning using plugging. The main role of source plugging or blocking is to create dose falloff in the junction between a target and a critical structure. We report the use of MAGAT gel dosimeter for verification of ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v13i6.3877

    authors: Natanasabapathi G,Subbiah V,Kale SS,Rath GK,Senthilkumaran S,Thulkar S,Subramani V,Laviraj MA,Bisht RK,Mahapatra AK

    更新日期:2012-11-08 00:00:00

  • On correlations in IMRT planning aims.

    abstract::The purpose was to study correlations amongst IMRT DVH evaluation points and how their relaxation impacts the overall plan. 100 head-and-neck cancer cases, using the Eclipse treatment planning system with the same protocol, are statisti-cally analyzed for PTV, brainstem, and spinal cord. To measure variations amongst ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i6.6411

    authors: Roy A,Das IJ,Nohadani O

    更新日期:2016-11-08 00:00:00

  • Gemstone spectral imaging: determination of CT to ED conversion curves for radiotherapy treatment planning.

    abstract::The monochromatic images acquired by Gemstone spectral imaging (GSI) mode on the GE CT750 HD theoretically determines the computed tomography (CT) number more accurately than that of conventional scanner. Using the former, the CT number is calculated from (synthesized) monoenergetic X-ray data. We reasoned that the mo...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v14i5.4335

    authors: Yagi M,Ueguchi T,Koizumi M,Ogata T,Yamada S,Takahashi Y,Sumida I,Akino Y,Konishi K,Isohashi F,Tomiyama N,Yoshioka Y,Ogawa K

    更新日期:2013-09-06 00:00:00

  • Verification of Varian Enhanced Dynamic Wedge implementation in masterplan treatment planning system.

    abstract::This paper investigates the accuracy of the two available calculation algorithms of the Oncentra MasterPlan three-dimensional treatment planning system (TPS)-- the pencil beam method and collapsed-cone convolution--in modeling the Varian enhanced dynamic wedge (EDW). Measurements were carried out for a dual high energ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v10i2.2867

    authors: Pasquino M,Borca VC,Tofani S,Ozzello F

    更新日期:2009-04-22 00:00:00

  • A feasibility study of multislice X-ray CT imaging of gel dosimeters using the "zero scan" method.

    abstract::This study extends the 'zero scan' method for CT imaging of polymer gel dosimeters to include multislice acquisitions. Multislice CT images consisting of 24 slices of 1.2 mm thickness were acquired of an irradiated polymer gel dosimeter and processed with the zero scan technique. The results demonstrate that zero scan...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i4.4360

    authors: Kakakhel MB,Kairn T,Charles P,Trapp JV

    更新日期:2014-07-08 00:00:00

  • Measurement of gantry rotation time in modern ct.

    abstract::The purpose of this study was to develop and evaluate a noninvasive method to assess rotation time in modern commercial computed tomography (CT) systems. The rotation time was measured at a selected nominal rotation time (400 ms) utilizing two types of solid-state detectors: the RTI's CT Dose Profiler (CTDP) and Unfor...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i1.4517

    authors: Fukuda A,Lin PJ,Matsubara K,Miyati T

    更新日期:2014-01-06 00:00:00