PURPOSE:This study evaluates the clinical use of the RUBY modular QA phantom for linac QA to validate the integrity of IGRT workflows including the congruence of machine isocenter, imaging isocenter, and room lasers. The results have been benchmarked against those obtained with widely used systems. Additionally, the RUBY phantom has been implemented to perform system QA (End-to-End testing) from imaging to radiation for IGRT-based VMAT and stereotactic radiations at an Elekta Synergy linac. MATERIAL AND METHODS:The daily check of IGRT workflow was performed using the RUBY phantom, the Penta-Guide, and the STEEV phantom. Furthermore, Winston-Lutz tests was carried out with the RUBY phantom and a ball-bearing phantom to determine the offsets and the diameters of the isospheres of gantry, collimator, and couch rotations, with respect to the room lasers and kV-imaging isocenter. System QA was performed with the RUBY phantom and STEEV phantom for eight VMAT treatment plans. Additionally, the visibility of the embedded objects within these phantoms in the images and the results of CT and MR image fusions were evaluated. RESULTS:All systems used for daily QA of IGRT workflows show comparable results. Calculated shifts based on CBCT imaging agree within 1 mm to the expected values. The results of the Winston-Lutz test based on kV imaging (2D planar and CBCT) or room lasers are consistent regardless of the system tested. The point dose values in the RUBY phantom agree to the expected values calculated using algorithms in Masterplan and Monte Carlo engine in Monaco within 3% of the clinical acceptance criteria. CONCLUSION:All the systems evaluated in this study yielded comparable results in terms of linac QA and system QA procedures. A system QA protocol has been derived using the RUBY phantom to check the IGRT-based VMAT and stereotactic radiations workflow at an Elekta Synergy linac.
journal_name
J Appl Clin Med Physjournal_title
Journal of applied clinical medical physicsauthors
Poppinga D,Kretschmer J,Brodbek L,Meyners J,Poppe B,Looe HKdoi
10.1002/acm2.13006subject
Has Abstractpub_date
2020-10-01 00:00:00pages
69-79issue
10issn
1526-9914journal_volume
21pub_type
杂志文章abstract::The objectives of this project are to quantify the dose reduction effect provided by a lead shield for patients with cardiac implantable electronic devices (CIED) during a clinically realistic radiation treatment on phantom and to provide a simple model of dose estimation to predict dose received by CIED in a wide ran...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v16i6.5317
更新日期:2015-11-08 00:00:00
abstract::This paper aims to evaluate the impact of spectral filtration on image quality in a microcomputed tomography (micro-CT) system. A mouse phantom comprising 11rods for modeling lung, muscle, adipose, and bones was scanned with 17 s and 2min, respectively. The current (μA) for each scan was adjusted to achieve identical ...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v17i1.5714
更新日期:2016-01-08 00:00:00
abstract:PURPOSE:Prescription practice in SRS plans for brain tumors differs significantly for different modalities. In this retrospective study, the strategies to optimize SRS plans for brain tumors with volumetric arc therapy (VMAT) were presented. METHODS:Fifty clinically treated cases were stratified by the maximum target ...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12818
更新日期:2020-03-01 00:00:00
abstract::We examined the dose distributions generated by Pinnacle3 (Philips Radiation Oncology Systems, Milpitas, CA) for intensity-modulated radiotherapy (IMRT) plans using a cubic-block-piled compensator as the intensity modulator for 4-MV and 10-MV photon beams. The Pinnacle treatment planning system (TPS) uses an algorithm...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v8i1.2323
更新日期:2006-06-16 00:00:00
abstract::Flattening filter-free (FFF) beams are becoming the preferred beam type for stereotactic radiosurgery (SRS) and stereotactic ablative radiation therapy (SABR), as they enable an increase in dose rate and a decrease in treatment time. This work assesses the effects of the flattening filter on small field output factors...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v17i3.6059
更新日期:2016-05-08 00:00:00
abstract:BACKGROUND AND PURPOSE:The purpose of this study of pancreatic cancer patients treated with respiratory-guided stereotactic body radiotherapy (SBRT) on a standard linac was to investigate (a) the intrafractional relationship change (IRC) between a breathing signal and the tumor position, (b) the impact of IRC on the de...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12841
更新日期:2020-03-01 00:00:00
abstract::In order to locate lung tumors on kV projection images without internal markers, digitally reconstructed radiographs (DRRs) are created and compared with projection images. However, lung tumors always move due to respiration and their locations change on projection images while they are static on DRRs. In addition, gl...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v16i3.5200
更新日期:2015-05-08 00:00:00
abstract:PURPOSE:The goal of this study was to find the optimal combination of collimator, photopeak and scatter correction for 177 Lutetium (177 Lu) SPECT/CT imaging. METHODS:Three experiments [sphere-to-background ratios (SBR) 50:1, 10:1, and 2:1] were performed with the NEMA Image Quality phantom filled with 177 Lu-trichlor...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12991
更新日期:2020-09-01 00:00:00
abstract:PURPOSE:To establish a streamlined end-to-end test of a 6 degrees-of-freedom (6DoF) robotic table using a 3D printed phantom for periodic quality assurance. METHODS:A 3D printed phantom was fabricated with translational and rotational offsets and an imbedded central ball-bearing (BB). The phantom underwent each step o...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12227
更新日期:2018-01-01 00:00:00
abstract::Special attention is required in planning and administering radiation therapy to patients with cardiac implantable electronic devices (CIEDs), such as pacemaker and defibrillator. The range of dose to CIEDs that can induce malfunction is large among CIEDs. Clinically significant defects have been reported at dose as l...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12229
更新日期:2018-01-01 00:00:00
abstract::This study utilizes process control techniques to identify action limits for TomoTherapy couch positioning quality assurance tests. A test was introduced to monitor accuracy of the applied couch offset detection in the TomoTherapy Hi-Art treatment system using the TQA "Step-Wedge Helical" module and MVCT detector. Ind...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12136
更新日期:2017-09-01 00:00:00
abstract::This study evaluated unexpected dosimetric errors caused by machine control accuracy, patient setup errors, and patient weight changes/internal organ deformations. Trajectory log files for 13 gynecologic plans with seven- or nine-beam dynamic multileaf collimator (MLC) intensity-modulated radiation therapy (IMRT), and...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.13163
更新日期:2021-01-10 00:00:00
abstract::The purpose of this study is to determine whether organ sparing and target coverage can be simultaneously maintained for pencil beam scanning (PBS) proton therapy treatment of thoracic tumors in the presence of motion, stopping power uncertainties, and patient setup variations. Ten consecutive patients that were previ...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v16i6.5678
更新日期:2015-11-08 00:00:00
abstract::Routine constancy checks of electron energy are often time consuming because of the necessity to measure a dose at two depths. A technique is described that uses a double-wedge shaped phantom positioned on a Profiler diode array for measuring an electron energy constancy metric similar to R(50). The double-wedge elect...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v4i3.2516
更新日期:2003-07-01 00:00:00
abstract::Substantial disagreement exists over appropriate PET segmentation techniques for non-small cell lung cancer. Currently, no segmentation algorithm explicitly considers tumor motion in determining tumor borders. We developed an automatic PET segmentation model as a function of target volume, motion extent, and source-to...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v15i1.4600
更新日期:2014-01-06 00:00:00
abstract:PURPOSE:Targeting and tracking of central lung tumors may be feasible on the Elekta MRI-linac (MRL) due to the soft-tissue visualization capabilities of MRI. The purpose of this work is to develop a novel treatment planning methodology to simulate tracking of central lung tumors with the MRL and to quantify the benefit...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12233
更新日期:2018-01-01 00:00:00
abstract::For patients with medically inoperable early-stage non-small cell lung cancer (NSCLC) treated with stereotactic body radiation therapy, early treatment plans were based on a simpler dose calculation algorithm, the pencil beam (PB) calculation. Because these patients had the longest treatment follow-up, identifying dos...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v16i6.5514
更新日期:2015-11-08 00:00:00
abstract::The purpose of this study was to perform comprehensive measurements and testing of a Novalis Tx linear accelerator, and to develop technical guidelines for com-missioning from the time of acceptance testing to the first clinical treatment. The Novalis Tx (NTX) linear accelerator is equipped with, among other features,...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v13i3.3729
更新日期:2012-05-10 00:00:00
abstract::The aim of this work is to evaluate the performance of a commercial brachytherapy treatment planning system (TPS) with TG-43 Vendors Input Data (VID), analyze possible discrepancies with respect to a proper reference source and its implications for standard treatments, and judge the effectiveness of certain widespread...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v16i4.4730
更新日期:2015-07-08 00:00:00
abstract::The purpose of this study was to investigate amplitude gating combined with a coached breathing strategy for 10 MV flattening filter-free (FFF) volumetric-modulated arc therapy (VMAT) on the Varian TrueBeam linac. Ten patient plans for VMAT SABR liver were created using the Eclipse treatment planning system (TPS). The...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v16i4.5350
更新日期:2015-07-08 00:00:00
abstract::A new calculation algorithm has been developed for independently verifying doses calculated by the TomoTherapy Hi.Art treatment planning system (TPS). The algorithm is designed to confirm the dose to a point in a high dose, low dose-gradient region. Patient data used by the algorithm include the radiological depth to ...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v10i1.2772
更新日期:2009-02-05 00:00:00
abstract::Shewhart control charts have previously been suggested as a process control tool for use in routine linear accelerator (linac) output verifications. However, a comprehensive approach to process control has not been investigated for linac output verifications. The purpose of this work is to investigate a comprehensive ...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v14i1.4032
更新日期:2013-01-07 00:00:00
abstract:PURPOSE:This study aimed to evaluate dosimetric differences of intensity-modulated radiation therapy (IMRT) in target and normal tissues after breast-conserving surgery. METHODS:IMRT five-field plan I, IMRT six-field plan II, and field-in-field-direct machine parameter optimization-IMRT plan III were designed for each...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12287
更新日期:2018-05-01 00:00:00
abstract::The purpose of this work is to evaluate the volumetric-modulated arc therapy (VMAT) multicriteria optimization (MCO) algorithm clinically available in the RayStation treatment planning system (TPS) and its ability to reduce treatment planning time while providing high dosimetric plan quality. Nine patients with locali...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v16i3.5410
更新日期:2015-05-08 00:00:00
abstract::This study investigates the dosimetry and radiobiological model variation when a second photon arc was added to prostate volumetric-modulated arc therapy (VMAT) using the single-arc technique. Dosimetry and radiobiological model comparison between the single-arc and double-arc prostate VMAT plans were performed on fiv...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v14i3.4053
更新日期:2013-05-06 00:00:00
abstract:PURPOSE:Adaptive radiotherapy (ART) has potential to reduce toxicity and facilitate safe dose escalation. Dose calculations with the planning CT deformed to cone beam CT (CBCT) have shown promise for estimating the "dose of the day". The purpose of this study is to investigate the "dose of the day" calculation accuracy...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12793
更新日期:2020-01-01 00:00:00
abstract::Documentation is a required component of a residency program, but can be difficult to collect and disseminate, resulting in minimal utilization by residents and faculty. The purpose of this work is to adapt a commercially-available Web-based medical residency management system to improve the learning experience by eff...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v15i6.4866
更新日期:2014-11-08 00:00:00
abstract::The purpose of this study was to demonstrate that Monte Carlo treatment planning systems require tissue characterization (density and composition) as a function of CT number. A discrete set of tissue classes with a specific composition is introduced. In the current work we demonstrate that, for megavoltage photon radi...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v16i5.5586
更新日期:2015-09-08 00:00:00
abstract::The use of a radioactive check device containing Strontium 90 was investigated to carry out the redundancy checks of Farmer-type ionization chambers. It was not possible to meet the recommended tolerance limits of the redundancy checks without taking into account the angular response of the ionization chambers. The io...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v1i4.2636
更新日期:2000-10-01 00:00:00
abstract:INTRODUCTION:Increased modulation and dynamical delivery of external beam radiotherapy (EBRT), such as volumetric modulated arc therapy (VMAT) with dynamic gantry rotation, continuously variable dose rate (CVDR) and field shapes that change during the beam, place greater demands on the performance of linear accelerator...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.13047
更新日期:2020-10-23 00:00:00