The impact of spectral filtration on image quality in micro-CT system.

Abstract:

:This paper aims to evaluate the impact of spectral filtration on image quality in a microcomputed tomography (micro-CT) system. A mouse phantom comprising 11rods for modeling lung, muscle, adipose, and bones was scanned with 17 s and 2min, respectively. The current (μA) for each scan was adjusted to achieve identical entrance exposure to the phantom, providing a baseline for image quality evaluation. For each region of interest (ROI) within specific composition, CT number variations, noise levels, and contrast-to-noise ratios (CNRs) were evaluated from the reconstructed images. CT number variations and CNRs for bone with high density, muscle, and adipose were compared with theoretical predictions. The results show that the impact of spectral filtration on image quality indicators, such as CNR in a micro-CT system, is significantly associated with tissue characteristics. The findings may provide useful references for optimizing the scanning parameters of general micro-CT systems in future imaging applications.

journal_name

J Appl Clin Med Phys

authors

Ren L,Ghani MU,Wu D,Zheng B,Chen Y,Yang K,Wu X,Liu H

doi

10.1120/jacmp.v17i1.5714

subject

Has Abstract

pub_date

2016-01-08 00:00:00

pages

301-315

issue

1

issn

1526-9914

journal_volume

17

pub_type

杂志文章
  • Dosimetric characteristics of LinaTech DMLC H multi leaf collimator: Monte Carlo simulation and experimental study.

    abstract::This study evaluated the basic dosimetric characteristics of a Dynamic Multi Leaf Collimator (DMLC) using a diode detector and film measurements for Intensity Modulated Radiation Therapy Quality Assurance (IMRT QA). The EGSnrc Monte Carlo (MC) simulation system was used for the determination of MLC characteristics. Ra...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12055

    authors: Molazadeh M,Zeinali A,Robatjazi M,Shirazi A,Geraily G

    更新日期:2017-03-01 00:00:00

  • Evaluation of the combined use of two different respiratory monitoring systems for 4D CT simulation and gated treatment.

    abstract:PURPOSE:Two different respiratory monitoring systems (Varian's Real-Time Position Management (RPM) System and Siemens' ANZAI belt Respiratory Gating System) are compared in the context of respiratory signals and 4D CT images that are accordingly reconstructed. This study aims to evaluate the feasibility of combined use...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12434

    authors: Liu J,Lin T,Fan J,Chen L,Price R,Ma CC

    更新日期:2018-09-01 00:00:00

  • Prostate volumetric-modulated arc therapy: dosimetry and radiobiological model variation between the single-arc and double-arc technique.

    abstract::This study investigates the dosimetry and radiobiological model variation when a second photon arc was added to prostate volumetric-modulated arc therapy (VMAT) using the single-arc technique. Dosimetry and radiobiological model comparison between the single-arc and double-arc prostate VMAT plans were performed on fiv...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v14i3.4053

    authors: Chow JC,Jiang R

    更新日期:2013-05-06 00:00:00

  • On the optimization of bone SPECT/CT in terms of image quality and radiation dose.

    abstract:INTRODUCTION:The purpose of this study was to present the optimization process of CT parameters to reduce patient exposure during bone SPECT/CT without affecting the quality of SPECT images with attenuation correction (AC). MATERIAL AND METHODS:A fillable phantom reflecting realistic bone scintigraphy conditions was d...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.13069

    authors: Tulik M,Tulik P,Kowalska T

    更新日期:2020-10-27 00:00:00

  • Assessment of PlanIQ Feasibility DVH for head and neck treatment planning.

    abstract:INTRODUCTION:Designing a radiation plan that optimally delivers both target coverage and normal tissue sparing is challenging. There are limited tools to determine what is dosimetrically achievable and frequently the experience of the planner/physician is relied upon to make these determinations. PlanIQ software provid...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12165

    authors: Fried DV,Chera BS,Das SK

    更新日期:2017-09-01 00:00:00

  • Optimizing the target detectability of cone beam CT performed in image-guided radiation therapy for patients of different body sizes.

    abstract:PURPOSE:The target detectability of cone beam computed tomography (CBCT) performed in image-guided radiation therapy (IGRT) was investigated to achieve sufficient image quality for patient positioning over a course of treatment session while maintaining radiation exposure from CBCT imaging as low as reasonably achievab...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12306

    authors: Yang CC,Yu PC,Ruan JM,Chen YC

    更新日期:2018-05-01 00:00:00

  • Optimization of photon beam energy in aperture-based inverse planning.

    abstract::Optimal choice of beam energy in radiation therapy is easy in many well-documented cases, but less obvious in some others. Low-energy beams may provide better conformity around the target than their high-energy counterparts due to reduced lateral scatter, but they also contribute to overdosage of peripheral normal tis...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v10i4.3012

    authors: St-Hilaire J,Sévigny C,Beaulieu F,Gingras L,Tremblay D,Beaulieu L

    更新日期:2009-09-03 00:00:00

  • Evaluation of offline adaptive planning techniques in image-guided brachytherapy of cervical cancer.

    abstract::Modern three-dimensional image-guided intracavitary high dose rate (HDR) brachytherapy is often used in combination with external beam radiotherapy (EBRT) to manage cervical cancer. Intrafraction motion of critical organs relative to the HDR applicator in the time between the planning CT and treatment delivery can cau...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12462

    authors: Liu H,Kinard J,Maurer J,Shang Q,Vanderstraeten C,Hayes L,Sintay B,Wiant D

    更新日期:2018-11-01 00:00:00

  • A fast, independent dose check of HDR plans.

    abstract::High dose rate (HDR) brachytherapy often involves optimization routines to calculate the dwell times and positions of a radioactive source along specified applicator paths. These routines optimize the dwells in such a way as to deliver the prescribed dose at one or more points while satisfying various constraints. The...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v4i2.2530

    authors: Lachaine ME,Gorman JC,Palisca MG

    更新日期:2003-04-01 00:00:00

  • Trajectory log analysis and cone-beam CT-based daily dose calculation to investigate the dosimetric accuracy of intensity-modulated radiotherapy for gynecologic cancer.

    abstract::This study evaluated unexpected dosimetric errors caused by machine control accuracy, patient setup errors, and patient weight changes/internal organ deformations. Trajectory log files for 13 gynecologic plans with seven- or nine-beam dynamic multileaf collimator (MLC) intensity-modulated radiation therapy (IMRT), and...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.13163

    authors: Utena Y,Takatsu J,Sugimoto S,Sasai K

    更新日期:2021-01-10 00:00:00

  • Independent calculation of dose from a helical TomoTherapy unit.

    abstract::A new calculation algorithm has been developed for independently verifying doses calculated by the TomoTherapy Hi.Art treatment planning system (TPS). The algorithm is designed to confirm the dose to a point in a high dose, low dose-gradient region. Patient data used by the algorithm include the radiological depth to ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v10i1.2772

    authors: Gibbons JP,Smith K,Cheek D,Rosen I

    更新日期:2009-02-05 00:00:00

  • Optimization of motion management parameters in a synchrotron-based spot scanning system.

    abstract:PURPOSE:To quantify the effects of combining layer-based repainting and respiratory gating as a strategy to mitigate the dosimetric degradation caused by the interplay effect between a moving target and dynamic spot-scanning proton delivery. METHODS:An analytic routine modeled three-dimensional dose distributions of p...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12702

    authors: Johnson JE,Herman MG,Kruse JJ

    更新日期:2019-09-01 00:00:00

  • On the sensitivity of TG-119 and IROC credentialing to TPS commissioning errors.

    abstract::We investigate the sensitivity of IMRT commissioning using the TG-119 C-shape phantom and credentialing with the IROC head and neck phantom to treatment planning system commissioning errors. We introduced errors into the various aspects of the commissioning process for a 6X photon energy modeled using the analytical a...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i1.5452

    authors: McVicker D,Yin FF,Adamson JD

    更新日期:2016-01-08 00:00:00

  • Independent review of 4DCT scans used for SABR treatment planning.

    abstract::Four-dimensional computerized tomography (4DCT) is required for stereotactic ablative body radiotherapy (SABR) of mobile targets to account for tumor motion during treatment planning and delivery. In this study, we report on the impact of an image review quality assurance process performed prior to treatment planning ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12825

    authors: Antony R,Lonski P,Ungureanu E,Hardcastle N,Yeo A,Siva S,Kron T

    更新日期:2020-03-01 00:00:00

  • Improved dosimetric accuracy with semi-automatic contour propagation of organs-at-risk in glioblastoma patients undergoing chemoradiation.

    abstract:BACKGROUND:We study the changes in organs-at-risk (OARs) morphology as contoured on serial MRIs during chemoradiation therapy (CRT) of glioblastoma (GBM). The dosimetric implication of assuming non-deformable OAR changes and the accuracy and feasibility of semi-automatic OAR contour propagation are investigated. METHO...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12758

    authors: Lee S,Stewart J,Lee Y,Myrehaug S,Sahgal A,Ruschin M,Tseng CL

    更新日期:2019-12-01 00:00:00

  • Volumetric-modulated arc therapy planning using multicriteria optimization for localized prostate cancer.

    abstract::The purpose of this work is to evaluate the volumetric-modulated arc therapy (VMAT) multicriteria optimization (MCO) algorithm clinically available in the RayStation treatment planning system (TPS) and its ability to reduce treatment planning time while providing high dosimetric plan quality. Nine patients with locali...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i3.5410

    authors: Ghandour S,Matzinger O,Pachoud M

    更新日期:2015-05-08 00:00:00

  • Using mean dose rate to compare relative dosimetric efficiency with respect to source type and source change schedules for HDR brachytherapy.

    abstract::Remote afterloading devices used for high-dose-rate (HDR) brachytherapy may be supplied with different sources, and these sources typically have differing initial source strengths. In addition, the proposed frequency for source changes may also vary, depending upon the source type. Dosimetric parameters unique to each...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v14i6.4239

    authors: Davis SD,Parker W,Evans MD

    更新日期:2013-11-04 00:00:00

  • An open-source software for monitoring intrafraction motion during external beam radiation therapy based on superimposition of contours of projected ROIs on cine-MV images.

    abstract:PURPOSE:To present an open-source software (https://github.com/CHUSRadOncPhys/FluoMV) for monitoring intrafraction motion that is based on the visualization of superimposed contours of projected region-of-interests from DICOM RTSTRUCT files on cine-MV images acquired and displayed in real-time during radiation therapy ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12940

    authors: Lessard R,Tremblay NM,Plourde MÉ,Guillot M

    更新日期:2020-08-01 00:00:00

  • A new homogeneity index based on statistical analysis of the dose-volume histogram.

    abstract::The goal of the present study was to develop a new dose-volume histogram (DVH)- based homogeneity index for effectively evaluating the dose homogeneity of intensity-modulated radiotherapy plans. The new index, called the sigma-index ("S-index") is defined as the standard deviation of the normalized differential DVH cu...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v8i2.2390

    authors: Yoon M,Park SY,Shin D,Lee SB,Pyo HR,Kim DY,Cho KH

    更新日期:2007-03-20 00:00:00

  • Comparing gamma knife and cyberknife in patients with brain metastases.

    abstract::The authors compared the relative dosimetric merits of Gamma Knife (GK) and CyberKnife (CK) in 15 patients with 26 brain metastases. All patients were initially treated with the Leksell GK 4C. The same patients were used to generate comparative CK treatment plans. The tissue volume receiving more than 12 Gy (V12), the...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i1.4095

    authors: Sio TT,Jang S,Lee SW,Curran B,Pyakuryal AP,Sternick ES

    更新日期:2014-01-06 00:00:00

  • Geometric accuracy of the MR imaging techniques in the presence of motion.

    abstract::Magnetic Resonance Imaging (MRI) is increasingly being used for improving tumor delineation and tumor tracking in the presence of respiratory motion. The purpose of this work is to design and build an MR compatible motion platform and to use it for evaluating the geometric accuracy of MR imaging techniques during resp...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12274

    authors: Torfeh T,Hammoud R,El Kaissi T,McGarry M,Aouadi S,Fayad H,Al-Hammadi N

    更新日期:2018-03-01 00:00:00

  • Standardized flattening filter free volumetric modulated arc therapy plans based on anteroposterior width for total body irradiation.

    abstract::In this work, the feasibility of using flattening filter free (FFF) beams in volumetric modulated arc therapy (VMAT) total body irradiation (TBI) treatment planning to decrease protracted beam-on times for these treatments was investigated. In addition, a methodology was developed to generate standardized VMAT TBI tre...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12827

    authors: Frederick R,Hudson A,Balogh A,Cao JQ,Pierce G

    更新日期:2020-03-01 00:00:00

  • Case study of radiation therapy treatment of a patient with a cardiac ventricular assist device.

    abstract::A patient with a cardiac ventricular assist device (VAD) with computer-controlled driver presented to our department for radiation therapy. The treatment plan was 4500 cGy to the rectum over 25 fractions with 15MV photon beams. All beams avoided the pump and leads. The response to electromagnetic interference (EMI) wa...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v9i4.2851

    authors: Lasher DE,Wojcicka JB,Malcom R,Shears LL

    更新日期:2008-10-29 00:00:00

  • Optimization of intra-voxel incoherent motion measurement in diffusion-weighted imaging of breast cancer.

    abstract:PURPOSE:The purpose of this study was to optimize intra-voxel incoherent motion (IVIM) measurement in diffusion-weighted imaging (DWI) of breast cancer by separating perfusion and diffusion effects through the determination of an optimal threshold b-value, thus benign and cancerous breast tissues can be accurately diff...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12065

    authors: Chen W,Zhang J,Long D,Wang Z,Zhu JM

    更新日期:2017-05-01 00:00:00

  • On the complexity of helical tomotherapy treatment plans.

    abstract:PURPOSE:Multiple metrics are proposed to characterize and compare the complexity of helical tomotherapy (HT) plans created for different treatment sites. METHODS:A cohort composed of 208 HT plans from head and neck (105), prostate (51) and brain (52) tumor sites was considered. For each plan, 14 complexity metrics wer...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12895

    authors: Santos T,Ventura T,Mateus J,Capela M,Lopes MDC

    更新日期:2020-07-01 00:00:00

  • Statistical process control and verifying positional accuracy of a cobra motion couch using step-wedge quality assurance tool.

    abstract::This study utilizes process control techniques to identify action limits for TomoTherapy couch positioning quality assurance tests. A test was introduced to monitor accuracy of the applied couch offset detection in the TomoTherapy Hi-Art treatment system using the TQA "Step-Wedge Helical" module and MVCT detector. Ind...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12136

    authors: Binny D,Lancaster CM,Trapp JV,Crowe SB

    更新日期:2017-09-01 00:00:00

  • On the selection of gantry and collimator angles for isocenter localization using Winston-Lutz tests.

    abstract::In Winston-Lutz (WL) tests, the isocenter of a linear accelerator (linac) is determined as the intersection of radiation central axes (CAX) from multiple gantry, collimator, and couch angles. It is well known that the CAX can wobble due to mechanical imperfections of the linac. Previous studies suggested that the wobb...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i1.5792

    authors: Du W,Johnson JL,Jiang W,Kudchadker RJ

    更新日期:2016-01-08 00:00:00

  • Remote dosimetric auditing of clinical trials: The need for vendor specific models to convert images to dose.

    abstract:INTRODUCTION:A previous pilot study has demonstrated the feasibility of a novel image-based approach for remote dosimetric auditing of clinical trials. The approach uses a model to convert in-air acquired intensity modulated radiotherapy (IMRT) images to delivered dose inside a virtual phantom. The model was developed ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12521

    authors: Miri N,Vial P,Greer PB

    更新日期:2019-01-01 00:00:00

  • On the use of bolus for pacemaker dose measurement and reduction in radiation therapy.

    abstract::Special attention is required in planning and administering radiation therapy to patients with cardiac implantable electronic devices (CIEDs), such as pacemaker and defibrillator. The range of dose to CIEDs that can induce malfunction is large among CIEDs. Clinically significant defects have been reported at dose as l...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12229

    authors: Yan H,Guo F,Zhu D,Stryker S,Trumpore S,Roberts K,Higgins S,Nath R,Chen Z,Liu W

    更新日期:2018-01-01 00:00:00

  • Effect of skull shape approximations in Gamma Knife dose calculations.

    abstract::Doses in Leksell GammaPlan (Elekta, Stockholm, Sweden) are calculated for each shot by summing the contribution from the 201 radiation beams emitted by the Gamma Knife (Elekta), weighted for attenuation in the tissue traversed. The patient's head is modeled based on 24 skull measurements, from which the depth to the c...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v8i3.2377

    authors: Berndt A,Beck J

    更新日期:2007-07-17 00:00:00