Abstract:
:A new calculation algorithm has been developed for independently verifying doses calculated by the TomoTherapy Hi.Art treatment planning system (TPS). The algorithm is designed to confirm the dose to a point in a high dose, low dose-gradient region. Patient data used by the algorithm include the radiological depth to the point for each projection angle and the treatment sinogram file controlling the leaf opening time for each projection. The algorithm uses common dosimetric functions [tissue phantom ratio (TPR) and output factor (Scp)] for the central axis combined with lateral and longitudinal beam profile data to quantify the off-axis dose dependence. Machine data for the dosimetric functions were measured on the Hi.Art machine and simulated using the TPS. Point dose calculations were made for several test phantoms and for 97 patient treatment plans using the simulated machine data. Comparisons with TPS-predicted point doses for the phantom treatment plans demonstrated agreement within 2% for both on-axis and off-axis planning target volumes (PTVs). Comparisons with TPS-predicted point doses for the patient treatment plans also showed good agreement. For calculations at sites other than lung and superficial PTVs, agreement between the calculations was within 2% for 94% of the patient calculations (64 of 68). Calculations within lung and superficial PTVs overestimated the dose by an average of 3.1% (sigma=2.4%) and 3.2% (sigma=2.2%), respectively. Systematic errors within lung are probably due to the weakness of the algorithm in correcting for missing tissue and/or tissue density heterogeneities. Errors encountered within superficial PTVs probably result from the algorithm overestimating the scatter dose within the patient. Our results demonstrate that for the majority of cases, the algorithm could be used without further refinement to independently verify patient treatment plans.
journal_name
J Appl Clin Med Physjournal_title
Journal of applied clinical medical physicsauthors
Gibbons JP,Smith K,Cheek D,Rosen Idoi
10.1120/jacmp.v10i1.2772subject
Has Abstractpub_date
2009-02-05 00:00:00pages
103-119issue
1issn
1526-9914journal_volume
10pub_type
杂志文章abstract::The QFix EncompassTM stereotactic radiosurgery (SRS) immobilization system consists of a thermoplastic mask that attaches to the couch insert to immobilize patients treated with intracranial SRS. This study evaluates the dosimetric impact and verifies a vendor provided treatment planning system (TPS) model in the Ecli...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12387
更新日期:2018-07-01 00:00:00
abstract::In Winston-Lutz (WL) tests, the isocenter of a linear accelerator (linac) is determined as the intersection of radiation central axes (CAX) from multiple gantry, collimator, and couch angles. It is well known that the CAX can wobble due to mechanical imperfections of the linac. Previous studies suggested that the wobb...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v17i1.5792
更新日期:2016-01-08 00:00:00
abstract::The dosimetry of very small electron fields can be challenging due to relative shifts in percent depth-dose curves, including the location of dmax, and lack of lateral electronic equilibrium in an ion chamber when placed in the beam. Conventionally a small parallel plate chamber or film is utilized to perform small fi...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v12i1.3267
更新日期:2010-10-04 00:00:00
abstract::Small field dosimetry is a challenging task. The difficulties of small field measurements, particularly stereotactic field size measurements, are highlighted by the large interinstitution variability that can be observed for circular cone collimator commissioning measurements. We believe the best way to improve the co...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v14i6.4493
更新日期:2013-11-04 00:00:00
abstract::Breast treatments are becoming increasingly complex as the use of modulated and partial breast therapies becomes more prevalent. These methods are predicated on accurate and precise positioning for treatment. However, the ability to quantify intrafraction motion has been limited by the excessive dose that would result...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v15i6.4957
更新日期:2014-11-08 00:00:00
abstract:INTRODUCTION:A previous pilot study has demonstrated the feasibility of a novel image-based approach for remote dosimetric auditing of clinical trials. The approach uses a model to convert in-air acquired intensity modulated radiotherapy (IMRT) images to delivered dose inside a virtual phantom. The model was developed ...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12521
更新日期:2019-01-01 00:00:00
abstract:PURPOSE:The goal of this study was to find the optimal combination of collimator, photopeak and scatter correction for 177 Lutetium (177 Lu) SPECT/CT imaging. METHODS:Three experiments [sphere-to-background ratios (SBR) 50:1, 10:1, and 2:1] were performed with the NEMA Image Quality phantom filled with 177 Lu-trichlor...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12991
更新日期:2020-09-01 00:00:00
abstract::The aim of this work is to evaluate the performance of a commercial brachytherapy treatment planning system (TPS) with TG-43 Vendors Input Data (VID), analyze possible discrepancies with respect to a proper reference source and its implications for standard treatments, and judge the effectiveness of certain widespread...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v16i4.4730
更新日期:2015-07-08 00:00:00
abstract::The use of a radioactive check device containing Strontium 90 was investigated to carry out the redundancy checks of Farmer-type ionization chambers. It was not possible to meet the recommended tolerance limits of the redundancy checks without taking into account the angular response of the ionization chambers. The io...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v1i4.2636
更新日期:2000-10-01 00:00:00
abstract:PURPOSE/OBJECTIVES:To present our linac-based SRS procedural technique for medically and/or surgically refractory trigeminal neuralgia (TN) treatment and simultaneously report our clinical outcomes. MATERIALS AND METHODS:Twenty-seven refractory TN patients who were treated with a single fraction of 80 Gy to TN. Treatm...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12057
更新日期:2017-03-01 00:00:00
abstract::A thermobrachytherapy surface applicator (TBSA) was developed for simultaneous heat and brachytherapy treatment of chest wall (CW) recurrence of breast cancer. The ability to comfortably secure the applicator over the upper torso relative to the CW target throughout treatment is assessed on volunteers. Male and postma...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v13i5.3845
更新日期:2012-09-06 00:00:00
abstract:PURPOSE:We conducted this dosimetric analysis to evaluate the feasibility of a multi-center stereotactic body radiation therapy (SBRT) trial for renal cell carcinoma (RCC) using different SBRT platforms. MATERIALS/METHODS:The computed tomography (CT) simulation images of 10 patients with unilateral RCC previously trea...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12308
更新日期:2018-03-14 00:00:00
abstract:PURPOSE:We introduce an automated, quantitative image analysis package for gamma camera and single photon emission computed tomography quality control. Our focus was to produce consistent methods that are feasible in clinical settings and use standard phantoms. METHODS:Four gamma cameras were used to acquire planar im...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.13057
更新日期:2020-11-03 00:00:00
abstract::Performing a procedure on the wrong patient or site is one of the greatest errors that can occur in medicine. The addition of automation has been shown to reduce errors in many processes. In this work we explore the use of an automated patient identification process using optical surface imaging for radiotherapy treat...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v17i2.6066
更新日期:2016-03-08 00:00:00
abstract::Traditional quality assurance checks of a patient's radiation therapy plan involve printing out treatment parameters from the treatment planning system and the "record and verify" (R&V) system and visually checking the information for one-to-one correspondence. In a paperless environment, one can automate this process...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v10i1.2905
更新日期:2009-01-27 00:00:00
abstract::PET/CT imaging could improve delineation of rectal carcinoma gross tumor volume (GTV) and reduce interobserver variability. The objective of this work was to compare various functional volume delineation algorithms. We enrolled 31 consecutive patients with locally advanced rectal carcinoma. The FDG PET/CT and the high...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v15i5.4696
更新日期:2014-09-08 00:00:00
abstract::Two patients with multiple lung metastases (≥ 5) were treated using frameless stereotactic body radiation therapy (SBRT) on an Elekta Axesse linear accelerator equipped with an interdigitation-capable multileaf collimator and four-dimensional cone-beam CT (4D CBCT). The technique and the early clinical outcomes were e...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v15i4.4737
更新日期:2014-07-08 00:00:00
abstract::The design concept and dosimetric characteristics of a new applicator system for intraoperative radiation therapy (IORT) are presented in this work. A new hard-docking commercial system includes polymethylmethacrylate (PMMA) applicators with different diameters and applicator end angles and a set of secondary lead col...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v11i4.3244
更新日期:2010-07-19 00:00:00
abstract::The aim of this study was to assess the performance of a gantry-mounted detector system and a couch set detector system using a systematic multileaf collimator positional error manually introduced for volumetric-modulated arc therapy. Four head and neck and esophagus VMAT plans were evaluated by measurement using an e...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v15i3.4495
更新日期:2014-05-08 00:00:00
abstract:PURPOSE:Segmentation of liver organ and tumors from computed tomography (CT) scans is an important task for hepatic surgical planning. Manual segmentation of liver and tumors is tedious, time-consuming, and biased to the clinician experience. Therefore, automatic segmentation of liver and tumors is highly desirable. It...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.13003
更新日期:2020-10-01 00:00:00
abstract::The purpose of this study is to describe the comprehensive commissioning process and initial clinical experience of the Mevion S250 proton therapy system, a gantry-mounted, single-room proton therapy platform clinically implemented in the S. Lee Kling Proton Therapy Center at Barnes-Jewish Hospital in St. Louis, MO, U...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v17i2.5868
更新日期:2016-03-08 00:00:00
abstract:PURPOSE:This study evaluates the feasibility of lung dose prediction based on target contour and patient anatomy for breast patients treated with proton therapy. METHODS:Fifty-two randomly selected patients were included in the cohort, who were treated to 50.4-66.4 Gy(RBE) to the left (36), right (15), or bilateral (1...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章,随机对照试验
doi:10.1002/acm2.12436
更新日期:2018-11-01 00:00:00
abstract::Flattening filter-free (FFF) beams produce higher dose rates. Combined with compensator-based intensity modulated radiotherapy (IMRT) techniques, the dose delivery for each beam can be much shorter compared to the flattened beam MLC-based or flattened beam compensator-based IMRT. This 'snap shot' IMRT delivery is bene...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12018
更新日期:2017-01-01 00:00:00
abstract::A custom-made computer program, SWIMRT, to construct "multileaf collimator (MLC) machine" file for intensity-modulated radiotherapy (IMRT) fluence maps was developed using MATLAB and the sliding window algorithm. The user can either import a fluence map with a graphical file format created by an external treatment-pla...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v7i2.2231
更新日期:2006-05-25 00:00:00
abstract:BACKGROUND:We study the changes in organs-at-risk (OARs) morphology as contoured on serial MRIs during chemoradiation therapy (CRT) of glioblastoma (GBM). The dosimetric implication of assuming non-deformable OAR changes and the accuracy and feasibility of semi-automatic OAR contour propagation are investigated. METHO...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12758
更新日期:2019-12-01 00:00:00
abstract::The primary study objective was to assess radiation doses using a modified form of the Imaging Performance Assessment of Computed Tomography (CT) scanner (ImPACT) patient dosimetry for cardiac applications on an Aquilion ONE ViSION Edition scanner, including the Ca score, target computed tomography angiography (CTA), ...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v17i4.6218
更新日期:2016-07-08 00:00:00
abstract:OBJECT:The purpose of this study was to compare two methods of stereotactic localization in Gamma Knife treatment planning: cone beam computed tomography (CBCT) or fiducial. While the fiducial method is the traditional method of localization, CBCT is now available for use with the Gamma Knife Icon. This study seeks to ...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12745
更新日期:2019-11-01 00:00:00
abstract::Stereotactic body radiation therapy (SBRT) has been increasingly used as an efficacious treatment modality for early-stage non-small cell lung cancer. The accuracy of dose calculations is compromised due to the presence of inhomogeneity. For the purpose of a consistent prescription, radiation doses were calculated wit...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v14i2.4011
更新日期:2013-03-04 00:00:00
abstract:PURPOSE:The weighted CT dose index (CTDIw ) has been extended for a nominal total collimation width (nT) greater than 40 mm and relies on measurements of CTDIfreeair. The purpose of this work was to compare three methods of measuring CTDIfreeair and subsequent calculations of CTDIw to investigate their clinical appropr...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12363
更新日期:2018-07-01 00:00:00
abstract::Part II of this review article presents four case studies for which peak skin doses are calculated following the methods outlined in Part I of this review. The data available in the cases ranges from proprietary dose reports to fluoroscopy time and number of digital acquisition frames only. Flowcharts are provided for...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v13i1.3693
更新日期:2012-01-05 00:00:00