Interfraction positional variation in pancreatic tumors using daily breath-hold cone-beam computed tomography with visual feedback.

Abstract:

:We assessed interfraction positional variation in pancreatic tumors using daily breath-hold cone-beam computed tomography at end-exhalation (EE) with visual feedback (BH-CBCT). Eleven consecutive patients with pancreatic cancer who underwent BH intensity-modulated radiation therapy with visual feedback were enrolled. All participating patients stopped oral intake, with the exception of drugs and water, for > 3 hr before treatment planning and daily treatment. Each patient was fixed in the supine position on an individualized vacuum pillow. An isotropic margin of 5 mm was added to the clinical target volume to create the planning target volume (PTV). The prescription dose was 42 to 51 Gy in 15 fractions. After correcting initial setup errors based on bony anatomy, the first BH-CBCT scans were performed before beam delivery in every fraction. BH-CBCT acquisition was obtained in three or four times breath holds by interrupting the acquisition two or three times, depending on the patient's BH ability. The image acquisition time for a 360° gantry rotation was approximately 90 s, including the interruption time due to BH. The initial setup errors were corrected based on bony structure, and the residual errors in the target position were then recorded. The magnitude of the interfraction variation in target position was assessed for 165 fractions. The systematic and random errors were 1.2 and 1.8 mm, 1.1 and 1.8 mm, and 1.7 and 2.9 mm in the left-right (LR), anterior-posterior (AP), and superior-inferior (SI) directions, respectively. Absolute interfraction variations of > 5 mm were observed in 18 fractions (11.0%) from seven patients because of EE-BH failure. In conclusion, target matching is required to correct interfraction variation even with visual feedback, especially to ensure safe delivery of escalated doses to patients with pancreatic cancer.

journal_name

J Appl Clin Med Phys

authors

Nakamura M,Akimoto M,Ono T,Nakamura A,Yano S,Nakata M,Itasaka S,Mizowaki T,Shibuya K,Hiraoka M

doi

10.1120/jacmp.v16i2.5123

subject

Has Abstract

pub_date

2015-03-08 00:00:00

pages

5123

issue

2

issn

1526-9914

journal_volume

16

pub_type

杂志文章
  • Effect of RTOG breast/chest wall guidelines on dose-volume histogram parameters.

    abstract::Treatment planning for breast cancer has been traditionally based on clinical landmarks. The Radiation Therapy Oncology Group (RTOG) published consensus guidelines on contouring target volumes (TV) for the breast/chest wall and draining lymphatics. The effect of these guidelines on dosimetric parameters in surrounding...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i2.4547

    authors: Rudra S,Al-Hallaq HA,Feng C,Chmura SJ,Hasan Y

    更新日期:2014-03-06 00:00:00

  • Accurate method for evaluating the duration of the entire radiotherapy process.

    abstract:BACKGROUND AND PURPOSE:Along with the increasing demand for high-quality radiotherapy and the growing number of high-precision radiotherapy devices, precise radiotherapy workflow management and accurate time evaluation of the entire radiotherapy process are crucial to providing appropriate, timely treatment for cancer ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12959

    authors: Guo C,Huang P,Li Y,Dai J

    更新日期:2020-09-01 00:00:00

  • Dosimetric characterization and use of GAFCHROMIC EBT3 film for IMRT dose verification.

    abstract::Radiochromic film has become an important tool to verify dose distributions in highly conformal radiation therapy such as IMRT. Recently, a new generation of these films, EBT3, has become available. EBT3 has the same composition and thickness of the sensitive layer of the previous EBT2 films, but its symmetric layer c...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v14i2.4111

    authors: Casanova Borca V,Pasquino M,Russo G,Grosso P,Cante D,Sciacero P,Girelli G,La Porta MR,Tofani S

    更新日期:2013-03-04 00:00:00

  • Applying three different methods of measuring CTDIfree air to the extended CTDI formalism for wide-beam scanners (IEC 60601-2-44): A comparative study.

    abstract:PURPOSE:The weighted CT dose index (CTDIw ) has been extended for a nominal total collimation width (nT) greater than 40 mm and relies on measurements of CTDIfreeair. The purpose of this work was to compare three methods of measuring CTDIfreeair and subsequent calculations of CTDIw to investigate their clinical appropr...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12363

    authors: Bujila R,Kull L,Danielsson M,Andersson J

    更新日期:2018-07-01 00:00:00

  • A clinical 3D/4D CBCT-based treatment dose monitoring system.

    abstract::To monitor delivered dose and trigger plan adaptation when deviation becomes unacceptable, a clinical treatment dose (Tx-Dose) reconstruction system based on three-dimensional (3D)/four-dimensional (4D)-cone beam computed tomograpy (CBCT) images was developed and evaluated on various treatment sites, particularly for ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12474

    authors: Qin A,Gersten D,Liang J,Liu Q,Grill I,Guerrero T,Stevens C,Yan D

    更新日期:2018-11-01 00:00:00

  • A computational tool for the efficient analysis of dose-volume histograms from radiation therapy treatment plans.

    abstract::A Histogram Analysis in Radiation Therapy (HART) program was primarily developed to increase the efficiency and accuracy of dose-volume histogram (DVH) analysis of large quantities of patient data in radiation therapy research. The program was written in MATLAB to analyze patient plans exported from the treatment plan...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:

    authors: Pyakuryal A,Myint WK,Gopalakrishnan M,Jang S,Logemann JA,Mittal BB

    更新日期:2010-01-28 00:00:00

  • Free-breathing conformal irradiation of pancreatic cancer.

    abstract::The purpose of this study was to assess treatment margins in free-breathing irradiation of pancreatic cancer after bone alignment, and evaluate their impact on conformal radiotherapy. Fifteen patients with adenocarcinoma of the head of the pancreas underwent implantation of single fiducial marker. Intrafraction uncert...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v14i4.4152

    authors: Solla I,Zucca S,Possanzini M,Piras S,Pusceddu C,Porru S,Meleddu G,Farace P

    更新日期:2013-07-08 00:00:00

  • Patient-specific 17-segment myocardial modeling on a bull's eye map.

    abstract::The purpose of this study was to develop and validate cardiac computed tomog-raphy (CT) quantitative analysis software with a patient-specific, 17-segment myocardial model that uses electrocardiogram (ECG)-gated cardiac CT images to differentiate between normal controls and severe aortic stenosis (AS) patients. ECG-ga...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i5.6237

    authors: Jung J,Kim YH,Kim N,Yang DH

    更新日期:2016-09-08 00:00:00

  • A study on image quality provided by a kilovoltage cone-beam computed tomography.

    abstract::The image-guided radiotherapy technique (IGRT) makes use of imaging devices to verify the positions of the target volume and organs at risk during the treatment sessions. In this work we evaluate the image quality provided by an imaging system based on a kilovoltage cone-beam CT, and explore its ability to perform IGR...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v14i1.3888

    authors: Garayoa J,Castro P

    更新日期:2013-01-07 00:00:00

  • Dosimetric characteristics of a cubic-block-piled compensator for intensity-modulated radiation therapy in the Pinnacle radiotherapy treatment planning system.

    abstract::We examined the dose distributions generated by Pinnacle3 (Philips Radiation Oncology Systems, Milpitas, CA) for intensity-modulated radiotherapy (IMRT) plans using a cubic-block-piled compensator as the intensity modulator for 4-MV and 10-MV photon beams. The Pinnacle treatment planning system (TPS) uses an algorithm...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v8i1.2323

    authors: Sasaki K,Obata Y

    更新日期:2006-06-16 00:00:00

  • A review of patient questions from physicist-patient consults.

    abstract:PURPOSE:To provide insight into the types of questions asked to medical physicists by patients during one-on-one physicist-patient consults at one institution. MATERIALS AND METHODS:Medical physicists trained in patient communication techniques met with patients to provide an overview of the treatment planning and del...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12942

    authors: Atwood TF,Brown DW,Juang T,Moore KL,McConnell KA,Steers JM,Murphy JD,Mundt AJ,Pawlicki T

    更新日期:2020-08-01 00:00:00

  • Generation of wedge-shaped dose distributions through dynamic multileaf collimator dose delivery.

    abstract::A new method of generating wedge-shaped dose distributions through dynamic multileaf collimator dose delivery rather than computer-controlled jaw motion is presented. The method starts with the calculation of a wedge-shaped beam profile for the desired wedge angle. The resultant wedge beam profile is then passed to th...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v6i3.2060

    authors: Zhu J

    更新日期:2005-07-01 00:00:00

  • Commissioning and validation of BrainLAB cones for 6X FFF and 10X FFF beams on a Varian TrueBeam STx.

    abstract::Small field dosimetry is a challenging task. The difficulties of small field measurements, particularly stereotactic field size measurements, are highlighted by the large interinstitution variability that can be observed for circular cone collimator commissioning measurements. We believe the best way to improve the co...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v14i6.4493

    authors: Wiant DB,Terrell JA,Maurer JM,Yount CL,Sintay BJ

    更新日期:2013-11-04 00:00:00

  • Investigation of error detection capabilities of phantom, EPID and MLC log file based IMRT QA methods.

    abstract::A patient specific quality assurance (QA) should detect errors that originate anywhere in the treatment planning process. However, the increasing complexity of treatment plans has increased the need for improvements in the accuracy of the patient specific pretreatment verification process. This has led to the utilizat...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12114

    authors: Defoor DL,Stathakis S,Roring JE,Kirby NA,Mavroidis P,Obeidat M,Papanikolaou N

    更新日期:2017-07-01 00:00:00

  • Translucent poly(vinyl alcohol) cryogel dosimeters for simultaneous dose buildup and monitoring during chest wall radiation therapy.

    abstract::Chest wall radiation therapy treatment delivery was monitored using a 5 mm thick radiochromic poly(vinyl alcohol) cryogel that also provided buildup material. The cryogels were used to detect positioning errors and measure the impact of shifts for a chest wall treatment that was delivered to a RANDO phantom. The phant...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i5.6148

    authors: Eyadeh MM,Weston MA,Juhasz J,Diamond KR

    更新日期:2016-09-08 00:00:00

  • In vivo dosimetry and shielding disk alignment verification by EBT3 GAFCHROMIC film in breast IOERT treatment.

    abstract::Intraoperative electron radiation therapy (IOERT) cannot usually benefit, as conventional external radiotherapy, from software systems of treatment planning based on computed tomography and from common dose verify procedures. For this reason, in vivo film dosimetry (IVFD) proves to be an effective methodology to evalu...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i1.5065

    authors: Severgnini M,de Denaro M,Bortul M,Vidali C,Beorchia A

    更新日期:2014-01-08 00:00:00

  • Impact of grid size on uniform scanning and IMPT plans in XiO treatment planning system for brain cancer.

    abstract::The main purposes of this study are to: 1) evaluate the accuracy of XiO treatment planning system (TPS) for different dose calculation grid size based on head phan-tom measurements in uniform scanning proton therapy (USPT); and 2) compare the dosimetric results for various dose calculation grid sizes based on real com...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i5.5510

    authors: Rana S,Zheng Y

    更新日期:2015-09-08 00:00:00

  • Automatic calculation of patient size metrics in computed tomography: What level of computational accuracy do we need?

    abstract:OBJECTIVES:To compare the effectiveness of two different patient size metrics based on water equivalent diameter (Dw ), the mid-scan water equivalent diameter Dw_c , and the mean (average) water equivalent diameter in the imaged region, Dw_ave , for automatic detection of accidental changes in computed tomography (CT) ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12240

    authors: Sarmento S,Mendes B,Gouvêa M

    更新日期:2018-01-01 00:00:00

  • A protocol to extend the longitudinal coverage of on-board cone-beam CT.

    abstract::The longitudinal coverage of a LINAC-mounted CBCT scan is limited to the corresponding dimensional limits of its flat panel detector, which is often shorter than the length of the treatment field. These limits become apparent when fields are designed to encompass wide regions, as when providing nodal coverage. Therefo...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v13i4.3796

    authors: Zheng D,Lu J,Jefferson A,Zhang C,Wu J,Sleeman W,Weiss E,Dogan N,Song S,Williamson J

    更新日期:2012-07-05 00:00:00

  • Small field electron beam dosimetry using MOSFET detector.

    abstract::The dosimetry of very small electron fields can be challenging due to relative shifts in percent depth-dose curves, including the location of dmax, and lack of lateral electronic equilibrium in an ion chamber when placed in the beam. Conventionally a small parallel plate chamber or film is utilized to perform small fi...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v12i1.3267

    authors: Amin MN,Heaton R,Norrlinger B,Islam MK

    更新日期:2010-10-04 00:00:00

  • Implementation of full/half bowtie filter models in a commercial treatment planning system for kilovoltage cone-beam CT dose estimations.

    abstract::The purpose of this study was to implement full/half bowtie filter models in a com-mercial treatment planning system (TPS) to calculate kilovoltage (kV) cone-beam CT (CBCT) doses of Varian On-Board Imager (OBI) kV X-ray imaging system. The full/half bowtie filter models were created as compensators in Pinnacle TPS usi...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i2.5988

    authors: Kim S,Alaei P

    更新日期:2016-03-08 00:00:00

  • A fast, independent dose check of HDR plans.

    abstract::High dose rate (HDR) brachytherapy often involves optimization routines to calculate the dwell times and positions of a radioactive source along specified applicator paths. These routines optimize the dwells in such a way as to deliver the prescribed dose at one or more points while satisfying various constraints. The...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v4i2.2530

    authors: Lachaine ME,Gorman JC,Palisca MG

    更新日期:2003-04-01 00:00:00

  • Remote dosimetric auditing of clinical trials: The need for vendor specific models to convert images to dose.

    abstract:INTRODUCTION:A previous pilot study has demonstrated the feasibility of a novel image-based approach for remote dosimetric auditing of clinical trials. The approach uses a model to convert in-air acquired intensity modulated radiotherapy (IMRT) images to delivered dose inside a virtual phantom. The model was developed ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12521

    authors: Miri N,Vial P,Greer PB

    更新日期:2019-01-01 00:00:00

  • Effect of electron contamination on in vivo dosimetry for lung block shielding during TBI.

    abstract::Our institution performs in vivo verification measurement for each of our total body irradiation (TBI) patients with optically stimulated luminescent dosimeters (OSLD). The lung block verification measurements were commonly higher than expected. The aim of this work is to understand this discrepancy and improve the ac...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i3.6128

    authors: Narayanasamy G,Cruz W,Saenz DL,Stathakis S,Papanikolaou N,Kirby N

    更新日期:2016-05-08 00:00:00

  • Development of system using beam's eye view images to measure respiratory motion tracking errors in image-guided robotic radiosurgery system.

    abstract::The accuracy of the CyberKnife Synchrony Respiratory Tracking System (SRTS) is considered to be patient-dependent because the SRTS relies on an individual correlation between the internal tumor position (ITP) and the external marker position (EMP), as well as a prediction method to compensate for the delay incurred to...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i1.5049

    authors: Inoue M,Shiomi H,Iwata H,Taguchi J,Okawa K,Kikuchi C,Inada K,Iwabuchi M,Murai T,Koike I,Tatewaki K,Ohta S,Inoue T

    更新日期:2015-01-08 00:00:00

  • The impact of isocentric shifts on delivery accuracy during the irradiation of small cerebral targets-Quantification and possible corrections.

    abstract:PURPOSE:To assess the impact of isocenter shifts due to linac gantry and table rotation during cranial stereotactic radiosurgery on D98 , target volume coverage (TVC), conformity (CI), and gradient index (GI). METHODS:Winston-Lutz (WL) checks were performed on two Elekta Synergy linacs. A stereotactic quality assuranc...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12854

    authors: Wack LJ,Exner F,Wegener S,Sauer OA

    更新日期:2020-05-01 00:00:00

  • Long term stability of a 50 kV X-ray unit for stereotactic irradiation.

    abstract::A low-energy (50 kV) X-ray tube used for the stereotactic irradiation of intracranial lesions has been in use since 1999. The unit is calibrated prior to every procedure and during periodic quality assurance (QA) tests. The unit uses an internal and an external scintillation detector to monitor dose as well as a conve...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v7i3.2238

    authors: Biggs PJ

    更新日期:2006-08-24 00:00:00

  • Radiation therapy plan checks in a paperless clinic.

    abstract::Traditional quality assurance checks of a patient's radiation therapy plan involve printing out treatment parameters from the treatment planning system and the "record and verify" (R&V) system and visually checking the information for one-to-one correspondence. In a paperless environment, one can automate this process...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v10i1.2905

    authors: Siochi RA,Pennington EC,Waldron TJ,Bayouth JE

    更新日期:2009-01-27 00:00:00

  • Independent calculation of dose from a helical TomoTherapy unit.

    abstract::A new calculation algorithm has been developed for independently verifying doses calculated by the TomoTherapy Hi.Art treatment planning system (TPS). The algorithm is designed to confirm the dose to a point in a high dose, low dose-gradient region. Patient data used by the algorithm include the radiological depth to ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v10i1.2772

    authors: Gibbons JP,Smith K,Cheek D,Rosen I

    更新日期:2009-02-05 00:00:00

  • Evaluation of offline adaptive planning techniques in image-guided brachytherapy of cervical cancer.

    abstract::Modern three-dimensional image-guided intracavitary high dose rate (HDR) brachytherapy is often used in combination with external beam radiotherapy (EBRT) to manage cervical cancer. Intrafraction motion of critical organs relative to the HDR applicator in the time between the planning CT and treatment delivery can cau...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12462

    authors: Liu H,Kinard J,Maurer J,Shang Q,Vanderstraeten C,Hayes L,Sintay B,Wiant D

    更新日期:2018-11-01 00:00:00