A clinical 3D/4D CBCT-based treatment dose monitoring system.

Abstract:

:To monitor delivered dose and trigger plan adaptation when deviation becomes unacceptable, a clinical treatment dose (Tx-Dose) reconstruction system based on three-dimensional (3D)/four-dimensional (4D)-cone beam computed tomograpy (CBCT) images was developed and evaluated on various treatment sites, particularly for lung cancer patient treated by stereotactic body radiation therapy (SBRT). This system integrates with our treatment planning system (TPS), Linacs recording and verification system (R&V), and CBCT imaging system, consisting of three modules: Treatment Schedule Monitoring module (TSM), pseudo-CT Generating module (PCG), and Treatment Dose Reconstruction/evaluation module (TDR). TSM watches the treatment progress in the R&V system and triggers the PCG module when new CBCT is available. PCG retrieves the CBCTs and performs planning CT to CBCT deformable registration (DIR) to generate pseudo-CT. The 4D-CBCT images are taken for target localization and correction in lung cancer patient before treatment. To take full advantage of the valuable information carried by 4D-CBCT, a novel phase-matching DIR scheme was developed to generate 4D pseudo-CT images for 4D dose reconstruction. Finally, TDR module creates TPS scripts to automate Tx-Dose calculation on the pseudo-CT images. Both initial quantitative commissioning and patient-specific qualitative quality assurance of the DIR tool were utilized to ensure the DIR quality. The treatment doses of ten patients (six SBRT-lung, two head and neck (HN), one breast and one prostate cancer patients) were retrospectively constructed and evaluated. The target registration error (mean ± STD: 1.05 ± 1.13 mm) of the DIR tool is comparable to the interobserver uncertainty (0.88 ± 1.31 mm) evaluated by a publically available lung-landmarks dataset. For lung SBRT patients, the D99 of the final cumulative Tx-Dose of GTV is 93.8 ± 5.5% (83.7-100.1%) of the originally planned D99 . CTV D99 decreases by 3% and mean ipsilateral parotid dose increases by 11.5% for one of the two HN patients. In conclusion, we have demonstrated the feasibility and effectiveness of a treatment dose verification system in our clinical setting.

journal_name

J Appl Clin Med Phys

authors

Qin A,Gersten D,Liang J,Liu Q,Grill I,Guerrero T,Stevens C,Yan D

doi

10.1002/acm2.12474

subject

Has Abstract

pub_date

2018-11-01 00:00:00

pages

166-176

issue

6

issn

1526-9914

journal_volume

19

pub_type

杂志文章
  • Distributive quality assurance and delivery of stereotactic ablative radiotherapy treatments amongst beam matched linear accelerators: A feasibility study.

    abstract:PURPOSE:Beam matching occurs on all linacs to some degree and when two are more are matched to each other, patients are able to be transferred between machines. Quality assurance of plans can also be performed "distributively" on any of the matched linacs. The degree to which machines are matched and how this translate...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12567

    authors: Rijken J,Schachenmayr H,Crowe S,Kairn T,Trapp J

    更新日期:2019-04-01 00:00:00

  • Radiographic film dosimetry for IMRT fields in the nearsurface buildup region.

    abstract::Radiographic film dosimetry provides fast, convenient 2-D dose distributions, but is challenged by the dependence of film response on scatter conditions (i.e., energy dependence). Verification of delivered dose in the surface buildup region is important for intensity modulated radiation therapy (IMRT) when volumes of ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v9i4.2782

    authors: Roberson PL,Moran JM,Kulasekere R

    更新日期:2008-10-24 00:00:00

  • Detector system dose verification comparisons for arc therapy: couch vs. gantry mount.

    abstract::The aim of this study was to assess the performance of a gantry-mounted detector system and a couch set detector system using a systematic multileaf collimator positional error manually introduced for volumetric-modulated arc therapy. Four head and neck and esophagus VMAT plans were evaluated by measurement using an e...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i3.4495

    authors: Manikandan A,Sarkar B,Nandy M,Sureka CS,Gossman MS,Sujatha N,Rajendran VT

    更新日期:2014-05-08 00:00:00

  • Failure mode and effects analysis: A community practice perspective.

    abstract:PURPOSE:To report our early experiences with failure mode and effects analysis (FMEA) in a community practice setting. METHODS:The FMEA facilitator received extensive training at the AAPM Summer School. Early efforts focused on department education and emphasized the need for process evaluation in the context of high ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12190

    authors: Schuller BW,Burns A,Ceilley EA,King A,LeTourneau J,Markovic A,Sterkel L,Taplin B,Wanner J,Albert JM

    更新日期:2017-11-01 00:00:00

  • Feasibility of a GATE Monte Carlo platform in a clinical pretreatment QA system for VMAT treatment plans using TrueBeam with an HD120 multileaf collimator.

    abstract:PURPOSE:To evaluate the quality of patient-specific complicated treatment plans, including commercialized treatment planning systems (TPS) and commissioned beam data, we developed a process of quality assurance (QA) using a Monte Carlo (MC) platform. Specifically, we constructed an interface system that automatically c...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12718

    authors: Lee B,Jeong S,Chung K,Yoon M,Park HC,Han Y,Jung SH

    更新日期:2019-10-01 00:00:00

  • Volumetric-modulated arc therapy planning using multicriteria optimization for localized prostate cancer.

    abstract::The purpose of this work is to evaluate the volumetric-modulated arc therapy (VMAT) multicriteria optimization (MCO) algorithm clinically available in the RayStation treatment planning system (TPS) and its ability to reduce treatment planning time while providing high dosimetric plan quality. Nine patients with locali...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i3.5410

    authors: Ghandour S,Matzinger O,Pachoud M

    更新日期:2015-05-08 00:00:00

  • Method and phantom to study combined effects of in-plane (x,y) and z-axis resolution for 3D CT imaging.

    abstract::Increasingly, the advent of multislice CT scanners, volume CT scanners, and total body spiral acquisition modes has led to the use of Multi Planar Reconstruction and 3D datasets. In considering 3D resolution properties of a CT system it is important to note that both the in-plane (x,y) and z-axis (slice thickness) inf...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i5.6294

    authors: Goodenough D,Levy J,Kristinsson S,Fredriksson J,Olafsdottir H,Healy A

    更新日期:2016-09-08 00:00:00

  • Quantitative variations in texture analysis features dependent on MRI scanning parameters: A phantom model.

    abstract:OBJECTIVES:To evaluate the influence of MRI scanning parameters on texture analysis features. METHODS:Publicly available data from the Reference Image Database to Evaluate Therapy Response (RIDER) project sponsored by The Cancer Imaging Archive included MRIs on a phantom comprised of 18 25-mm doped, gel-filled tubes, ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12482

    authors: Buch K,Kuno H,Qureshi MM,Li B,Sakai O

    更新日期:2018-11-01 00:00:00

  • A feasibility study of multislice X-ray CT imaging of gel dosimeters using the "zero scan" method.

    abstract::This study extends the 'zero scan' method for CT imaging of polymer gel dosimeters to include multislice acquisitions. Multislice CT images consisting of 24 slices of 1.2 mm thickness were acquired of an irradiated polymer gel dosimeter and processed with the zero scan technique. The results demonstrate that zero scan...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i4.4360

    authors: Kakakhel MB,Kairn T,Charles P,Trapp JV

    更新日期:2014-07-08 00:00:00

  • Comparison of two algorithms for determining beam weights and wedge filters.

    abstract::This article compares two algorithms for determining beam weights and wedge filters for conformal treatment planning. One algorithm, which is based on dose-gradient analysis, provides analytic formulas for determining beam weights, wedge angles, and collimator angles (i.e., wedge orientations) so that the dose distrib...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v3i3.2562

    authors: Dai J,Zhu Y

    更新日期:2002-07-01 00:00:00

  • Automating checks of plan check automation.

    abstract::While a few physicists have designed new plan check automation solutions for their clinics, fewer, if any, managed to adapt existing solutions. As complex and varied as the systems they check, these programs must gain the full confidence of those who would run them on countless patient plans. The present automation ef...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i4.4889

    authors: Halabi T,Lu HM

    更新日期:2014-07-08 00:00:00

  • Impact of incorporating visual biofeedback in 4D MRI.

    abstract::Precise radiation therapy (RT) for abdominal lesions is complicated by respiratory motion and suboptimal soft tissue contrast in 4D CT. 4D MRI offers improved con-trast although long scan times and irregular breathing patterns can be limiting. To address this, visual biofeedback (VBF) was introduced into 4D MRI. Ten v...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i3.6017

    authors: To DT,Kim JP,Price RG,Chetty IJ,Glide-Hurst CK

    更新日期:2016-05-08 00:00:00

  • Preventative maintenance and unscheduled downtime from an economic perspective.

    abstract::A spreadsheet-based model for economically characterizing the operation of a radiation treatment program has been used to perform a quantitative financial analysis of scheduled and unscheduled downtime. The incremental cost of downtime is broken down into three categories: remuneration of in-house or third party servi...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v1i2.2647

    authors: Dunscombe P,Roberts G,Valiquette L

    更新日期:2000-04-01 00:00:00

  • Deep learning and level set approach for liver and tumor segmentation from CT scans.

    abstract:PURPOSE:Segmentation of liver organ and tumors from computed tomography (CT) scans is an important task for hepatic surgical planning. Manual segmentation of liver and tumors is tedious, time-consuming, and biased to the clinician experience. Therefore, automatic segmentation of liver and tumors is highly desirable. It...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.13003

    authors: Alirr OI

    更新日期:2020-10-01 00:00:00

  • Impact of magnetic field regulation in conjunction with the volumetric repainting technique on the spot positions and beam range in pencil beam scanning proton therapy.

    abstract:PURPOSE:The objective of this study was to evaluate the impact of the magnetic field regulation in conjunction with the volumetric repainting technique on the spot positions and range in pencil beam scanning proton therapy. METHODS:"Field regulation" - a feature to reduce the switching time between layers by applying ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.13045

    authors: Rana S,Bennouna J,Gutierrez AN,Rosenfeld AB

    更新日期:2020-10-15 00:00:00

  • Optimization of motion management parameters in a synchrotron-based spot scanning system.

    abstract:PURPOSE:To quantify the effects of combining layer-based repainting and respiratory gating as a strategy to mitigate the dosimetric degradation caused by the interplay effect between a moving target and dynamic spot-scanning proton delivery. METHODS:An analytic routine modeled three-dimensional dose distributions of p...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12702

    authors: Johnson JE,Herman MG,Kruse JJ

    更新日期:2019-09-01 00:00:00

  • Evaluation of offline adaptive planning techniques in image-guided brachytherapy of cervical cancer.

    abstract::Modern three-dimensional image-guided intracavitary high dose rate (HDR) brachytherapy is often used in combination with external beam radiotherapy (EBRT) to manage cervical cancer. Intrafraction motion of critical organs relative to the HDR applicator in the time between the planning CT and treatment delivery can cau...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12462

    authors: Liu H,Kinard J,Maurer J,Shang Q,Vanderstraeten C,Hayes L,Sintay B,Wiant D

    更新日期:2018-11-01 00:00:00

  • Calculating the peak skin dose resulting from fluoroscopically-guided interventions. Part II: case studies.

    abstract::Part II of this review article presents four case studies for which peak skin doses are calculated following the methods outlined in Part I of this review. The data available in the cases ranges from proprietary dose reports to fluoroscopy time and number of digital acquisition frames only. Flowcharts are provided for...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v13i1.3693

    authors: Jones AK,Pasciak AS

    更新日期:2012-01-05 00:00:00

  • Simplified "on-couch" daily quality assurance procedure for CT simulators.

    abstract::For most computed tomography (CT) simulators, radiation therapists must remove the flat couch top to perform daily CT quality assurance (QA), and then use separate tools to perform localization-laser QA. This process wastes time and effort and creates the opportunity for accidents to occur. In this study, we tested a ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v10i3.2844

    authors: Liu RR,Prado K,Gillin M

    更新日期:2009-06-17 00:00:00

  • Preclinical assessment of comfort and secure fit of thermobrachytherapy surface applicator (TBSA) on volunteer subjects.

    abstract::A thermobrachytherapy surface applicator (TBSA) was developed for simultaneous heat and brachytherapy treatment of chest wall (CW) recurrence of breast cancer. The ability to comfortably secure the applicator over the upper torso relative to the CW target throughout treatment is assessed on volunteers. Male and postma...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v13i5.3845

    authors: Arunachalam K,Craciunescu OI,Markewitz EJ,Maccarini PF,Schlorff JL,Stauffer PR

    更新日期:2012-09-06 00:00:00

  • Dosimetric characteristics of a cubic-block-piled compensator for intensity-modulated radiation therapy in the Pinnacle radiotherapy treatment planning system.

    abstract::We examined the dose distributions generated by Pinnacle3 (Philips Radiation Oncology Systems, Milpitas, CA) for intensity-modulated radiotherapy (IMRT) plans using a cubic-block-piled compensator as the intensity modulator for 4-MV and 10-MV photon beams. The Pinnacle treatment planning system (TPS) uses an algorithm...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v8i1.2323

    authors: Sasaki K,Obata Y

    更新日期:2006-06-16 00:00:00

  • Measurement of the interplay effect in lung IMRT treatment using EDR2 films.

    abstract::Intra-fraction organ motion during the dynamic delivery of IMRT treatment of lung tumors may cause unexpected hot/cold spots even within the target volume, due to the interplay effect between tumor motion and multi-leaf collimator (MLC) leaf motion. In the past, this has been investigated through theoretical analysis,...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v7i4.2222

    authors: Berbeco RI,Pope CJ,Jiang SB

    更新日期:2006-11-28 00:00:00

  • Two-year experience with the commercial Gamma Knife Check software.

    abstract::The Gamma Knife Check software is an FDA approved second check system for dose calculations in Gamma Knife radiosurgery. The purpose of this study was to evaluate the accuracy and the stability of the commercial software package as a tool for independent dose verification. The Gamma Knife Check software version 8.4 wa...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i4.5547

    authors: Xu AY,Bhatnagar J,Bednarz G,Novotny J Jr,Flickinger J,Lunsford LD,Huq MS

    更新日期:2016-07-08 00:00:00

  • Effect of electron contamination on in vivo dosimetry for lung block shielding during TBI.

    abstract::Our institution performs in vivo verification measurement for each of our total body irradiation (TBI) patients with optically stimulated luminescent dosimeters (OSLD). The lung block verification measurements were commonly higher than expected. The aim of this work is to understand this discrepancy and improve the ac...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i3.6128

    authors: Narayanasamy G,Cruz W,Saenz DL,Stathakis S,Papanikolaou N,Kirby N

    更新日期:2016-05-08 00:00:00

  • Gemstone spectral imaging: determination of CT to ED conversion curves for radiotherapy treatment planning.

    abstract::The monochromatic images acquired by Gemstone spectral imaging (GSI) mode on the GE CT750 HD theoretically determines the computed tomography (CT) number more accurately than that of conventional scanner. Using the former, the CT number is calculated from (synthesized) monoenergetic X-ray data. We reasoned that the mo...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v14i5.4335

    authors: Yagi M,Ueguchi T,Koizumi M,Ogata T,Yamada S,Takahashi Y,Sumida I,Akino Y,Konishi K,Isohashi F,Tomiyama N,Yoshioka Y,Ogawa K

    更新日期:2013-09-06 00:00:00

  • Evaluation of three APBI techniques under NSABP B-39 guidelines.

    abstract::This work compares two accelerated partial breast irradiation modalities, MammoSite brachytherapy and three dimensional conformal radiotherapy (3D-CRT), to a new method, SAVI brachytherapy, following NSABP B-39 guidelines. A total of 21 patients treated at UC San Diego with the SAVI device were evaluated in this compa...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v11i1.3021

    authors: Scanderbeg D,Yashar C,White G,Rice R,Pawlicki T

    更新日期:2009-12-03 00:00:00

  • Contour-based lung dose prediction for breast proton therapy.

    abstract:PURPOSE:This study evaluates the feasibility of lung dose prediction based on target contour and patient anatomy for breast patients treated with proton therapy. METHODS:Fifty-two randomly selected patients were included in the cohort, who were treated to 50.4-66.4 Gy(RBE) to the left (36), right (15), or bilateral (1...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章,随机对照试验

    doi:10.1002/acm2.12436

    authors: Zeng C,Sine K,Mah D

    更新日期:2018-11-01 00:00:00

  • Evaluation of the RUBY modular QA phantom for planar and non-coplanar VMAT and stereotactic radiations.

    abstract:PURPOSE:This study evaluates the clinical use of the RUBY modular QA phantom for linac QA to validate the integrity of IGRT workflows including the congruence of machine isocenter, imaging isocenter, and room lasers. The results have been benchmarked against those obtained with widely used systems. Additionally, the RU...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.13006

    authors: Poppinga D,Kretschmer J,Brodbek L,Meyners J,Poppe B,Looe HK

    更新日期:2020-10-01 00:00:00

  • The impact of isocentric shifts on delivery accuracy during the irradiation of small cerebral targets-Quantification and possible corrections.

    abstract:PURPOSE:To assess the impact of isocenter shifts due to linac gantry and table rotation during cranial stereotactic radiosurgery on D98 , target volume coverage (TVC), conformity (CI), and gradient index (GI). METHODS:Winston-Lutz (WL) checks were performed on two Elekta Synergy linacs. A stereotactic quality assuranc...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12854

    authors: Wack LJ,Exner F,Wegener S,Sauer OA

    更新日期:2020-05-01 00:00:00

  • Production of neutrons in laminated barriers of radiotherapy rooms: comparison between the analytical methodology and Monte Carlo simulations.

    abstract::The necessity to build or adapt radiotherapy rooms in reduced areas leads to the search for unconventional solutions for shielding projects. In most cases, adding metals to the primary barriers is the best alternative to shield rooms properly. However, when photons with energies equal or higher than 10 MV interact wit...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i6.5035

    authors: Rezende GF,Da Rosa LA,Facure A

    更新日期:2014-11-08 00:00:00