Abstract:
:A patient specific quality assurance (QA) should detect errors that originate anywhere in the treatment planning process. However, the increasing complexity of treatment plans has increased the need for improvements in the accuracy of the patient specific pretreatment verification process. This has led to the utilization of higher resolution QA methods such as the electronic portal imaging device (EPID) as well as MLC log files and it is important to know the types of errors that can be detected with these methods. In this study, we will compare the ability of three QA methods (Delta4 ®, MU-EPID, Dynalog QA) to detect specific errors. Multileaf collimator (MLC) errors, gantry angle, and dose errors were introduced into five volumetric modulated arc therapy (VMAT) plans for a total of 30 plans containing errors. The original plans (without errors) were measured five times with each method to set a threshold for detectability using two standard deviations from the mean and receiver operating characteristic (ROC) derived limits. Gamma passing percentages as well as percentage error of planning target volume (PTV) were used for passing determination. When applying the standard 95% pass rate at 3%/3 mm gamma analysis errors were detected at a rate of 47, 70, and 27% for the Delta4 , MU-EPID and Dynalog QA respectively. When using thresholds set at 2 standard deviations from our base line measurements errors were detected at a rate of 60, 30, and 47% for the Delta4 , MU-EPID and Dynalog QA respectively. When using ROC derived thresholds errors were detected at a rate of 60, 27, and 47% for the Delta4 , MU-EPID and Dynalog QA respectively. When using dose to the PTV and the Dynalog method 11 of the 15 small MLC errors were detected while none were caught using gamma analysis. A combination of the EPID and Dynalog QA methods (scaling Dynalog doses using EPID images) matches the detection capabilities of the Delta4 by adding additional comparison metrics. These additional metrics are vital in relating the QA measurement to the dose received by the patient which is ultimately what is being confirmed.
journal_name
J Appl Clin Med Physjournal_title
Journal of applied clinical medical physicsauthors
Defoor DL,Stathakis S,Roring JE,Kirby NA,Mavroidis P,Obeidat M,Papanikolaou Ndoi
10.1002/acm2.12114subject
Has Abstractpub_date
2017-07-01 00:00:00pages
172-179issue
4issn
1526-9914journal_volume
18pub_type
杂志文章abstract::Radiographic film dosimetry provides fast, convenient 2-D dose distributions, but is challenged by the dependence of film response on scatter conditions (i.e., energy dependence). Verification of delivered dose in the surface buildup region is important for intensity modulated radiation therapy (IMRT) when volumes of ...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v9i4.2782
更新日期:2008-10-24 00:00:00
abstract::The GafChromic XR Type R film is a relatively new product for recording high radiation dose in interventional radiological procedures. Means of measuring the film response were studied in this investigation. Two handheld reflective-type densitometers of different models were compared in the range of 0-8 Gy. They were ...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v4i4.2501
更新日期:2003-10-01 00:00:00
abstract::Documentation is a required component of a residency program, but can be difficult to collect and disseminate, resulting in minimal utilization by residents and faculty. The purpose of this work is to adapt a commercially-available Web-based medical residency management system to improve the learning experience by eff...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v15i6.4866
更新日期:2014-11-08 00:00:00
abstract:PURPOSE:To establish a streamlined end-to-end test of a 6 degrees-of-freedom (6DoF) robotic table using a 3D printed phantom for periodic quality assurance. METHODS:A 3D printed phantom was fabricated with translational and rotational offsets and an imbedded central ball-bearing (BB). The phantom underwent each step o...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12227
更新日期:2018-01-01 00:00:00
abstract::The use of a radioactive check device containing Strontium 90 was investigated to carry out the redundancy checks of Farmer-type ionization chambers. It was not possible to meet the recommended tolerance limits of the redundancy checks without taking into account the angular response of the ionization chambers. The io...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v1i4.2636
更新日期:2000-10-01 00:00:00
abstract::The purpose of this study was to compare two different styles of prostate IGRT: bony landmark (BL) setup vs. fiducial markers (FM) setup. Twenty-nine prostate patients were treated with daily BL setup and 30 patients with daily FM setup. Delivered dose distribution was reconstructed on cone-beam CT (CBCT) acquired onc...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v14i3.4203
更新日期:2013-05-06 00:00:00
abstract::A low-energy (50 kV) X-ray tube used for the stereotactic irradiation of intracranial lesions has been in use since 1999. The unit is calibrated prior to every procedure and during periodic quality assurance (QA) tests. The unit uses an internal and an external scintillation detector to monitor dose as well as a conve...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v7i3.2238
更新日期:2006-08-24 00:00:00
abstract:PURPOSE:Elekta XVI 5.0 allows for four-dimensional cone beam computed tomography (4D CBCT) image acquisition during treatment delivery to monitor intrafraction motion. These images can have poorer image quality due to undersampling of kV projections and treatment beam MV scatter effects. We determine if a universal int...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12755
更新日期:2019-12-01 00:00:00
abstract::We conducted a metrological evaluation of the dosimetric impact due to the polysulfone cap used with the Fletcher-Williamson (FW) colpostat for 192Ir high-dose rate and pulsed-dose rate intracavitary brachytherapy using Monte Carlo simulations. Polysulfone caps with diameter of 30 mm, 25 mm, 20 mm, and 16 mm (mini-ovo...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v11i1.3146
更新日期:2010-01-28 00:00:00
abstract::This is a proof-of-concept study demonstrating the capacity for modulated electron radiation therapy (MERT) dose distributions using 3D printed bolus. Previous reports have involved bolus design using an electron pencil beam model and fabrication using a milling machine. In this study, an in-house algorithm is present...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v15i4.4831
更新日期:2014-07-08 00:00:00
abstract::Modern three-dimensional image-guided intracavitary high dose rate (HDR) brachytherapy is often used in combination with external beam radiotherapy (EBRT) to manage cervical cancer. Intrafraction motion of critical organs relative to the HDR applicator in the time between the planning CT and treatment delivery can cau...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12462
更新日期:2018-11-01 00:00:00
abstract:PURPOSE:Volumetric modulated arc therapy (VMAT) is gaining popularity for stereotactic treatment of lung lesions for medically inoperable patients. Due to multiple beamlets in delivery of highly modulated VMAT plans, there are dose delivery uncertainties associated with small-field dosimetry error and interplay effects...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12878
更新日期:2020-07-01 00:00:00
abstract:OBJECTIVES:To compare the effectiveness of two different patient size metrics based on water equivalent diameter (Dw ), the mid-scan water equivalent diameter Dw_c , and the mean (average) water equivalent diameter in the imaged region, Dw_ave , for automatic detection of accidental changes in computed tomography (CT) ...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12240
更新日期:2018-01-01 00:00:00
abstract::The aim of this study was to report a single-institution experience and commissioning data for Elekta VersaHD linear accelerators (LINACs) for photon beams in the Eclipse treatment planning system (TPS). Two VersaHD LINACs equipped with 160-leaf collimators were commissioned. For each energy, the percent-depth-dose (P...
journal_title:Journal of applied clinical medical physics
pub_type: 临床试验,杂志文章
doi:10.1002/acm2.12709
更新日期:2019-10-01 00:00:00
abstract::We have developed a treatment planning protocol for intensity-modulated radiation therapy of the prostate using commercially available inverse planning software. Treatment plans were developed for ten patients using the Corvus version 3.8 planning system, testing various prescription options, including tissue types, d...
journal_title:Journal of applied clinical medical physics
pub_type: 临床试验,杂志文章
doi:10.1120/jacmp.v2i2.2614
更新日期:2001-04-01 00:00:00
abstract::Optimal choice of beam energy in radiation therapy is easy in many well-documented cases, but less obvious in some others. Low-energy beams may provide better conformity around the target than their high-energy counterparts due to reduced lateral scatter, but they also contribute to overdosage of peripheral normal tis...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v10i4.3012
更新日期:2009-09-03 00:00:00
abstract::This study evaluated the basic dosimetric characteristics of a Dynamic Multi Leaf Collimator (DMLC) using a diode detector and film measurements for Intensity Modulated Radiation Therapy Quality Assurance (IMRT QA). The EGSnrc Monte Carlo (MC) simulation system was used for the determination of MLC characteristics. Ra...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12055
更新日期:2017-03-01 00:00:00
abstract:INTRODUCTION:This study aimed to investigate the feasibility of generating pseudo dual-energy CT (DECT) from one 120-kVp CT by using convolutional neural network (CNN) to derive additional information for quantitative image analysis through phantom study. METHODS:Dual-energy scans (80/140 kVp) and single-energy scans ...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.13148
更新日期:2020-10-14 00:00:00
abstract::Chest wall radiation therapy treatment delivery was monitored using a 5 mm thick radiochromic poly(vinyl alcohol) cryogel that also provided buildup material. The cryogels were used to detect positioning errors and measure the impact of shifts for a chest wall treatment that was delivered to a RANDO phantom. The phant...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v17i5.6148
更新日期:2016-09-08 00:00:00
abstract::The purpose of this study is to determine whether organ sparing and target coverage can be simultaneously maintained for pencil beam scanning (PBS) proton therapy treatment of thoracic tumors in the presence of motion, stopping power uncertainties, and patient setup variations. Ten consecutive patients that were previ...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v16i6.5678
更新日期:2015-11-08 00:00:00
abstract:PURPOSE:Although breast density is considered a strong risk factor of breast cancer, its quantitative assessment is difficult. To investigate a quantitative method of measuring breast density using dual-energy mammographic imaging with central digital breast tomosynthesis in physically uniform and nonuniform phantoms. ...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12618
更新日期:2019-06-01 00:00:00
abstract::The purpose of the present study was to use a kilovoltage imaging device to measure interfractional and intrafractional setup deviations in patients with head-and-neck or brain cancers receiving intensity-modulated radiotherapy (IMRT) treatment. Before and after IMRT treatment, approximately 3 times weekly, 7 patients...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v8i4.2439
更新日期:2007-09-24 00:00:00
abstract::Remote afterloading devices used for high-dose-rate (HDR) brachytherapy may be supplied with different sources, and these sources typically have differing initial source strengths. In addition, the proposed frequency for source changes may also vary, depending upon the source type. Dosimetric parameters unique to each...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v14i6.4239
更新日期:2013-11-04 00:00:00
abstract::Hypofractionated treatments generally increase the complexity of a treatment plan due to the more stringent constraints of normal tissues and target coverage. As a result, treatment plans contain more modulated MLC motions that may require extra efforts for accurate dose calculation. This study explores methods to min...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v17i2.4989
更新日期:2016-03-08 00:00:00
abstract::The purpose of the present study was to compare the impact of pulmonary function, body habitus, and stereotactic body radiation therapy (SBRT) immobilization on setup and reproducibility for upper lung tumor. From 2008 through 2011, our institution's prospective SBRT database was searched for patients with upper lung ...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v15i5.4931
更新日期:2014-09-08 00:00:00
abstract:BACKGROUND:We analyzed the clinical and imaging characteristics of patients with breast ductal carcinoma in situ with microinvasion (DCISM) and breast ductal carcinoma in situ (DCIS). METHODS:We analyzed the records of 40 patients diagnosed with DCISM and 61 patients with DCIS who were hospitalized at Shengjing Hospit...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.13122
更新日期:2020-12-17 00:00:00
abstract::Patient dose from 2.5 MV images on the TrueBeam linear accelerator is not easily quantified, primarily because this beam energy is not normally modeled by commercial treatment planning systems. In this work we present the feasibility of using the Eclipse® treatment planning system to model this beam. The Acuros XB and...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12756
更新日期:2019-12-01 00:00:00
abstract::In this study, we compared the amount of lung tissue irradiated when respiratory gating was imposed during expiration with the amount of lung tissue irradiated when gating was imposed during inspiration. Our hypothesis was that the amount of lung tissue spared increased as inspiration increased. Computed tomography (C...
journal_title:Journal of applied clinical medical physics
pub_type: 临床试验,杂志文章
doi:10.1120/jacmp.26.146
更新日期:2004-01-01 00:00:00
abstract::The main purposes of this study are to: 1) evaluate the accuracy of XiO treatment planning system (TPS) for different dose calculation grid size based on head phan-tom measurements in uniform scanning proton therapy (USPT); and 2) compare the dosimetric results for various dose calculation grid sizes based on real com...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v16i5.5510
更新日期:2015-09-08 00:00:00
abstract:PURPOSE:To investigate the daily setup, interfraction motion, variability in the junction areas, and dosimetric effect in craniospinal irradiation (CSI) patients. METHODS:Fifteen CSI patients who had undergone split-field IMRT were followed in the study. Previous, middle, and posttreatment, each target volume position...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12909
更新日期:2020-08-01 00:00:00