Investigation of error detection capabilities of phantom, EPID and MLC log file based IMRT QA methods.

Abstract:

:A patient specific quality assurance (QA) should detect errors that originate anywhere in the treatment planning process. However, the increasing complexity of treatment plans has increased the need for improvements in the accuracy of the patient specific pretreatment verification process. This has led to the utilization of higher resolution QA methods such as the electronic portal imaging device (EPID) as well as MLC log files and it is important to know the types of errors that can be detected with these methods. In this study, we will compare the ability of three QA methods (Delta4 ®, MU-EPID, Dynalog QA) to detect specific errors. Multileaf collimator (MLC) errors, gantry angle, and dose errors were introduced into five volumetric modulated arc therapy (VMAT) plans for a total of 30 plans containing errors. The original plans (without errors) were measured five times with each method to set a threshold for detectability using two standard deviations from the mean and receiver operating characteristic (ROC) derived limits. Gamma passing percentages as well as percentage error of planning target volume (PTV) were used for passing determination. When applying the standard 95% pass rate at 3%/3 mm gamma analysis errors were detected at a rate of 47, 70, and 27% for the Delta4 , MU-EPID and Dynalog QA respectively. When using thresholds set at 2 standard deviations from our base line measurements errors were detected at a rate of 60, 30, and 47% for the Delta4 , MU-EPID and Dynalog QA respectively. When using ROC derived thresholds errors were detected at a rate of 60, 27, and 47% for the Delta4 , MU-EPID and Dynalog QA respectively. When using dose to the PTV and the Dynalog method 11 of the 15 small MLC errors were detected while none were caught using gamma analysis. A combination of the EPID and Dynalog QA methods (scaling Dynalog doses using EPID images) matches the detection capabilities of the Delta4 by adding additional comparison metrics. These additional metrics are vital in relating the QA measurement to the dose received by the patient which is ultimately what is being confirmed.

journal_name

J Appl Clin Med Phys

authors

Defoor DL,Stathakis S,Roring JE,Kirby NA,Mavroidis P,Obeidat M,Papanikolaou N

doi

10.1002/acm2.12114

subject

Has Abstract

pub_date

2017-07-01 00:00:00

pages

172-179

issue

4

issn

1526-9914

journal_volume

18

pub_type

杂志文章
  • Radiographic film dosimetry for IMRT fields in the nearsurface buildup region.

    abstract::Radiographic film dosimetry provides fast, convenient 2-D dose distributions, but is challenged by the dependence of film response on scatter conditions (i.e., energy dependence). Verification of delivered dose in the surface buildup region is important for intensity modulated radiation therapy (IMRT) when volumes of ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v9i4.2782

    authors: Roberson PL,Moran JM,Kulasekere R

    更新日期:2008-10-24 00:00:00

  • A study of GafChromic XR Type R film response with reflective-type densitometers and economical flatbed scanners.

    abstract::The GafChromic XR Type R film is a relatively new product for recording high radiation dose in interventional radiological procedures. Means of measuring the film response were studied in this investigation. Two handheld reflective-type densitometers of different models were compared in the range of 0-8 Gy. They were ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v4i4.2501

    authors: Thomas G,Chu RY,Rabe F

    更新日期:2003-10-01 00:00:00

  • Towards a paperless medical physics residency management system.

    abstract::Documentation is a required component of a residency program, but can be difficult to collect and disseminate, resulting in minimal utilization by residents and faculty. The purpose of this work is to adapt a commercially-available Web-based medical residency management system to improve the learning experience by eff...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i6.4866

    authors: Schubert LK,Miften M

    更新日期:2014-11-08 00:00:00

  • Quality assurance for a six degrees-of-freedom table using a 3D printed phantom.

    abstract:PURPOSE:To establish a streamlined end-to-end test of a 6 degrees-of-freedom (6DoF) robotic table using a 3D printed phantom for periodic quality assurance. METHODS:A 3D printed phantom was fabricated with translational and rotational offsets and an imbedded central ball-bearing (BB). The phantom underwent each step o...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12227

    authors: Woods K,Ayan AS,Woollard J,Gupta N

    更新日期:2018-01-01 00:00:00

  • Use of a radioactive check device for redundancy check of ionization chambers.

    abstract::The use of a radioactive check device containing Strontium 90 was investigated to carry out the redundancy checks of Farmer-type ionization chambers. It was not possible to meet the recommended tolerance limits of the redundancy checks without taking into account the angular response of the ionization chambers. The io...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v1i4.2636

    authors: Sidhu NP,Rouvas A,Cadman P

    更新日期:2000-10-01 00:00:00

  • Utilization of cone beam CT for reconstruction of dose distribution delivered in image-guided radiotherapy of prostate carcinoma - bony landmark setup compared to fiducial markers setup.

    abstract::The purpose of this study was to compare two different styles of prostate IGRT: bony landmark (BL) setup vs. fiducial markers (FM) setup. Twenty-nine prostate patients were treated with daily BL setup and 30 patients with daily FM setup. Delivered dose distribution was reconstructed on cone-beam CT (CBCT) acquired onc...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v14i3.4203

    authors: Paluska P,Hanus J,Sefrova J,Rouskova L,Grepl J,Jansa J,Kasaova L,Hodek M,Zouhar M,Vosmik M,Petera J

    更新日期:2013-05-06 00:00:00

  • Long term stability of a 50 kV X-ray unit for stereotactic irradiation.

    abstract::A low-energy (50 kV) X-ray tube used for the stereotactic irradiation of intracranial lesions has been in use since 1999. The unit is calibrated prior to every procedure and during periodic quality assurance (QA) tests. The unit uses an internal and an external scintillation detector to monitor dose as well as a conve...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v7i3.2238

    authors: Biggs PJ

    更新日期:2006-08-24 00:00:00

  • Intrafraction 4D-cone beam CT acquired during volumetric arc radiotherapy delivery: kV parameter optimization and 4D motion accuracy for lung stereotactic body radiotherapy (SBRT) patients.

    abstract:PURPOSE:Elekta XVI 5.0 allows for four-dimensional cone beam computed tomography (4D CBCT) image acquisition during treatment delivery to monitor intrafraction motion. These images can have poorer image quality due to undersampling of kV projections and treatment beam MV scatter effects. We determine if a universal int...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12755

    authors: Liang J,Lack D,Zhou J,Liu Q,Grills I,Yan D

    更新日期:2019-12-01 00:00:00

  • Dose perturbation due to the polysulfone cap surrounding a Fletcher-Williamson colpostat.

    abstract::We conducted a metrological evaluation of the dosimetric impact due to the polysulfone cap used with the Fletcher-Williamson (FW) colpostat for 192Ir high-dose rate and pulsed-dose rate intracavitary brachytherapy using Monte Carlo simulations. Polysulfone caps with diameter of 30 mm, 25 mm, 20 mm, and 16 mm (mini-ovo...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v11i1.3146

    authors: Price MJ,Kry SF,Eifel PJ,Salehpour M,Mourtada F

    更新日期:2010-01-28 00:00:00

  • Design and production of 3D printed bolus for electron radiation therapy.

    abstract::This is a proof-of-concept study demonstrating the capacity for modulated electron radiation therapy (MERT) dose distributions using 3D printed bolus. Previous reports have involved bolus design using an electron pencil beam model and fabrication using a milling machine. In this study, an in-house algorithm is present...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i4.4831

    authors: Su S,Moran K,Robar JL

    更新日期:2014-07-08 00:00:00

  • Evaluation of offline adaptive planning techniques in image-guided brachytherapy of cervical cancer.

    abstract::Modern three-dimensional image-guided intracavitary high dose rate (HDR) brachytherapy is often used in combination with external beam radiotherapy (EBRT) to manage cervical cancer. Intrafraction motion of critical organs relative to the HDR applicator in the time between the planning CT and treatment delivery can cau...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12462

    authors: Liu H,Kinard J,Maurer J,Shang Q,Vanderstraeten C,Hayes L,Sintay B,Wiant D

    更新日期:2018-11-01 00:00:00

  • A novel and clinically useful dynamic conformal arc (DCA)-based VMAT planning technique for lung SBRT.

    abstract:PURPOSE:Volumetric modulated arc therapy (VMAT) is gaining popularity for stereotactic treatment of lung lesions for medically inoperable patients. Due to multiple beamlets in delivery of highly modulated VMAT plans, there are dose delivery uncertainties associated with small-field dosimetry error and interplay effects...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12878

    authors: Pokhrel D,Visak J,Sanford L

    更新日期:2020-07-01 00:00:00

  • Automatic calculation of patient size metrics in computed tomography: What level of computational accuracy do we need?

    abstract:OBJECTIVES:To compare the effectiveness of two different patient size metrics based on water equivalent diameter (Dw ), the mid-scan water equivalent diameter Dw_c , and the mean (average) water equivalent diameter in the imaged region, Dw_ave , for automatic detection of accidental changes in computed tomography (CT) ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12240

    authors: Sarmento S,Mendes B,Gouvêa M

    更新日期:2018-01-01 00:00:00

  • Modeling Elekta VersaHD using the Varian Eclipse treatment planning system for photon beams: A single-institution experience.

    abstract::The aim of this study was to report a single-institution experience and commissioning data for Elekta VersaHD linear accelerators (LINACs) for photon beams in the Eclipse treatment planning system (TPS). Two VersaHD LINACs equipped with 160-leaf collimators were commissioned. For each energy, the percent-depth-dose (P...

    journal_title:Journal of applied clinical medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1002/acm2.12709

    authors: Zhang Y,Le AH,Tian Z,Iqbal Z,Chiu T,Gu X,Pugachev A,Reynolds R,Park YK,Lin MH,Stojadinovic S

    更新日期:2019-10-01 00:00:00

  • Development of a treatment planning protocol for prostate treatments using intensity modulated radiotherapy.

    abstract::We have developed a treatment planning protocol for intensity-modulated radiation therapy of the prostate using commercially available inverse planning software. Treatment plans were developed for ten patients using the Corvus version 3.8 planning system, testing various prescription options, including tissue types, d...

    journal_title:Journal of applied clinical medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1120/jacmp.v2i2.2614

    authors: Ezzell GA,Schild SE,Wong WW

    更新日期:2001-04-01 00:00:00

  • Optimization of photon beam energy in aperture-based inverse planning.

    abstract::Optimal choice of beam energy in radiation therapy is easy in many well-documented cases, but less obvious in some others. Low-energy beams may provide better conformity around the target than their high-energy counterparts due to reduced lateral scatter, but they also contribute to overdosage of peripheral normal tis...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v10i4.3012

    authors: St-Hilaire J,Sévigny C,Beaulieu F,Gingras L,Tremblay D,Beaulieu L

    更新日期:2009-09-03 00:00:00

  • Dosimetric characteristics of LinaTech DMLC H multi leaf collimator: Monte Carlo simulation and experimental study.

    abstract::This study evaluated the basic dosimetric characteristics of a Dynamic Multi Leaf Collimator (DMLC) using a diode detector and film measurements for Intensity Modulated Radiation Therapy Quality Assurance (IMRT QA). The EGSnrc Monte Carlo (MC) simulation system was used for the determination of MLC characteristics. Ra...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12055

    authors: Molazadeh M,Zeinali A,Robatjazi M,Shirazi A,Geraily G

    更新日期:2017-03-01 00:00:00

  • Investigating the feasibility of generating dual-energy CT from one 120-kVp CT scan: a phantom study.

    abstract:INTRODUCTION:This study aimed to investigate the feasibility of generating pseudo dual-energy CT (DECT) from one 120-kVp CT by using convolutional neural network (CNN) to derive additional information for quantitative image analysis through phantom study. METHODS:Dual-energy scans (80/140 kVp) and single-energy scans ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.13148

    authors: Huang WH,Jhan KJ,Yang CC

    更新日期:2020-10-14 00:00:00

  • Translucent poly(vinyl alcohol) cryogel dosimeters for simultaneous dose buildup and monitoring during chest wall radiation therapy.

    abstract::Chest wall radiation therapy treatment delivery was monitored using a 5 mm thick radiochromic poly(vinyl alcohol) cryogel that also provided buildup material. The cryogels were used to detect positioning errors and measure the impact of shifts for a chest wall treatment that was delivered to a RANDO phantom. The phant...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i5.6148

    authors: Eyadeh MM,Weston MA,Juhasz J,Diamond KR

    更新日期:2016-09-08 00:00:00

  • Beam-specific planning target volumes incorporating 4D CT for pencil beam scanning proton therapy of thoracic tumors.

    abstract::The purpose of this study is to determine whether organ sparing and target coverage can be simultaneously maintained for pencil beam scanning (PBS) proton therapy treatment of thoracic tumors in the presence of motion, stopping power uncertainties, and patient setup variations. Ten consecutive patients that were previ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i6.5678

    authors: Lin L,Kang M,Huang S,Mayer R,Thomas A,Solberg TD,McDonough JE,Simone CB 2nd

    更新日期:2015-11-08 00:00:00

  • Quantitative evaluation of breast density using a dual-energy technique on a digital breast tomosynthesis system.

    abstract:PURPOSE:Although breast density is considered a strong risk factor of breast cancer, its quantitative assessment is difficult. To investigate a quantitative method of measuring breast density using dual-energy mammographic imaging with central digital breast tomosynthesis in physically uniform and nonuniform phantoms. ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12618

    authors: Lu KM,Yeh DM,Cao BH,Lin CY,Liang CY,Zhou YB,Tsai CJ

    更新日期:2019-06-01 00:00:00

  • Using an onboard kilovoltage imager to measure setup deviation in intensity-modulated radiation therapy for head-and-neck patients.

    abstract::The purpose of the present study was to use a kilovoltage imaging device to measure interfractional and intrafractional setup deviations in patients with head-and-neck or brain cancers receiving intensity-modulated radiotherapy (IMRT) treatment. Before and after IMRT treatment, approximately 3 times weekly, 7 patients...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v8i4.2439

    authors: Mechalakos JG,Hunt MA,Lee NY,Hong LX,Ling CC,Amols HI

    更新日期:2007-09-24 00:00:00

  • Using mean dose rate to compare relative dosimetric efficiency with respect to source type and source change schedules for HDR brachytherapy.

    abstract::Remote afterloading devices used for high-dose-rate (HDR) brachytherapy may be supplied with different sources, and these sources typically have differing initial source strengths. In addition, the proposed frequency for source changes may also vary, depending upon the source type. Dosimetric parameters unique to each...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v14i6.4239

    authors: Davis SD,Parker W,Evans MD

    更新日期:2013-11-04 00:00:00

  • Dose calculation for hypofractionated volumetric-modulated arc therapy: approximating continuous arc delivery and tongue-and-groove modeling.

    abstract::Hypofractionated treatments generally increase the complexity of a treatment plan due to the more stringent constraints of normal tissues and target coverage. As a result, treatment plans contain more modulated MLC motions that may require extra efforts for accurate dose calculation. This study explores methods to min...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i2.4989

    authors: Yang J,Tang G,Zhang P,Hunt M,Lim SB,LoSasso T,Mageras G

    更新日期:2016-03-08 00:00:00

  • Influence of patient's physiologic factors and immobilization choice with stereotactic body radiotherapy for upper lung tumors.

    abstract::The purpose of the present study was to compare the impact of pulmonary function, body habitus, and stereotactic body radiation therapy (SBRT) immobilization on setup and reproducibility for upper lung tumor. From 2008 through 2011, our institution's prospective SBRT database was searched for patients with upper lung ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i5.4931

    authors: Sio TT,Jensen AR,Miller RC,Fong de los Santos LE,Hallemeier CL,Foster NR,Park SS,Bauer HJ,Chang K,Garces YI,Olivier KR

    更新日期:2014-09-08 00:00:00

  • Clinical and imaging characteristics of breast ductal carcinoma in situ with microinvasion.

    abstract:BACKGROUND:We analyzed the clinical and imaging characteristics of patients with breast ductal carcinoma in situ with microinvasion (DCISM) and breast ductal carcinoma in situ (DCIS). METHODS:We analyzed the records of 40 patients diagnosed with DCISM and 61 patients with DCIS who were hospitalized at Shengjing Hospit...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.13122

    authors: Han S,Qiu F,Han Y,Xu Y,Yin J,Xing F,Bian X,He G

    更新日期:2020-12-17 00:00:00

  • Calculating dose from a 2.5 MV imaging beam using a commercial treatment planning system.

    abstract::Patient dose from 2.5 MV images on the TrueBeam linear accelerator is not easily quantified, primarily because this beam energy is not normally modeled by commercial treatment planning systems. In this work we present the feasibility of using the Eclipse® treatment planning system to model this beam. The Acuros XB and...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12756

    authors: Ferris WS,Culberson WS,Anderson DR,Labby ZE

    更新日期:2019-12-01 00:00:00

  • Dosimetric benefits of respiratory gating: a preliminary study.

    abstract::In this study, we compared the amount of lung tissue irradiated when respiratory gating was imposed during expiration with the amount of lung tissue irradiated when gating was imposed during inspiration. Our hypothesis was that the amount of lung tissue spared increased as inspiration increased. Computed tomography (C...

    journal_title:Journal of applied clinical medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1120/jacmp.26.146

    authors: Butler LE,Forster KM,Stevens CW,Bloch C,Liu HH,Tucker SL,Komaki R,Liao Z,Starkschall G

    更新日期:2004-01-01 00:00:00

  • Impact of grid size on uniform scanning and IMPT plans in XiO treatment planning system for brain cancer.

    abstract::The main purposes of this study are to: 1) evaluate the accuracy of XiO treatment planning system (TPS) for different dose calculation grid size based on head phan-tom measurements in uniform scanning proton therapy (USPT); and 2) compare the dosimetric results for various dose calculation grid sizes based on real com...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i5.5510

    authors: Rana S,Zheng Y

    更新日期:2015-09-08 00:00:00

  • Evaluating the positional uncertainty of intrafraction, adjacent fields, and daily setup with the BrainLAB ExacTrac system in patients who are receiving craniospinal irradiation.

    abstract:PURPOSE:To investigate the daily setup, interfraction motion, variability in the junction areas, and dosimetric effect in craniospinal irradiation (CSI) patients. METHODS:Fifteen CSI patients who had undergone split-field IMRT were followed in the study. Previous, middle, and posttreatment, each target volume position...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12909

    authors: Duan X,Zhou Y,Dai H,Zhao L,Qian J,Yang D,Zhang L,Luo C,Li G

    更新日期:2020-08-01 00:00:00