Abstract:
PURPOSE:To provide insight into the types of questions asked to medical physicists by patients during one-on-one physicist-patient consults at one institution. MATERIALS AND METHODS:Medical physicists trained in patient communication techniques met with patients to provide an overview of the treatment planning and delivery processes, discuss the patient's treatment plan, and answer any technical questions. From August 2016 to December 2019, 152 physicist-patient consults were conducted. In the initial months of the study (August 2016-December 2017), following each physicist-patient consult, all patient questions were documented by the physicists. For the remaining time period (January 2018-December 2019), any newly encountered questions were periodically added to the list. The questions were compiled into a comprehensive list and organized into categories. RESULTS:There were a total of 88 unique patient questions. These questions fit into four topical categories. Fifty-four questions (61.4%) were in the "Treatment Planning and Delivery Questions" category, 15 questions (17.1%) were in the "General Radiation Questions or Concerns" category, 13 questions (14.8%) were in the "Safety and Quality Assurance Questions" category, and 6 questions (6.8%) were in the "Medical Questions" category. Overall, patients were primarily concerned about how radiation works, the treatment planning and delivery processes, and what is being done to keep them safe throughout their treatment. CONCLUSION:Physicist-patient consults provided an opportunity to address the technical aspects of radiation therapy with patients in greater detail. The fact that patient questions could be conveniently grouped into only four topical categories indicates that it may be straightforward for other medical physicists to prepare for effectively addressing technical questions during physicist-patient consults.
journal_name
J Appl Clin Med Physjournal_title
Journal of applied clinical medical physicsauthors
Atwood TF,Brown DW,Juang T,Moore KL,McConnell KA,Steers JM,Murphy JD,Mundt AJ,Pawlicki Tdoi
10.1002/acm2.12942subject
Has Abstractpub_date
2020-08-01 00:00:00pages
305-308issue
8issn
1526-9914journal_volume
21pub_type
杂志文章abstract::The purpose of this study was to assess treatment margins in free-breathing irradiation of pancreatic cancer after bone alignment, and evaluate their impact on conformal radiotherapy. Fifteen patients with adenocarcinoma of the head of the pancreas underwent implantation of single fiducial marker. Intrafraction uncert...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v14i4.4152
更新日期:2013-07-08 00:00:00
abstract::The purpose of this study is to describe the comprehensive commissioning process and initial clinical experience of the Mevion S250 proton therapy system, a gantry-mounted, single-room proton therapy platform clinically implemented in the S. Lee Kling Proton Therapy Center at Barnes-Jewish Hospital in St. Louis, MO, U...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v17i2.5868
更新日期:2016-03-08 00:00:00
abstract::The purpose of this study was to develop and validate cardiac computed tomog-raphy (CT) quantitative analysis software with a patient-specific, 17-segment myocardial model that uses electrocardiogram (ECG)-gated cardiac CT images to differentiate between normal controls and severe aortic stenosis (AS) patients. ECG-ga...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v17i5.6237
更新日期:2016-09-08 00:00:00
abstract:PURPOSE:We conducted this dosimetric analysis to evaluate the feasibility of a multi-center stereotactic body radiation therapy (SBRT) trial for renal cell carcinoma (RCC) using different SBRT platforms. MATERIALS/METHODS:The computed tomography (CT) simulation images of 10 patients with unilateral RCC previously trea...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12308
更新日期:2018-03-14 00:00:00
abstract:PURPOSE:This study evaluates the clinical use of the RUBY modular QA phantom for linac QA to validate the integrity of IGRT workflows including the congruence of machine isocenter, imaging isocenter, and room lasers. The results have been benchmarked against those obtained with widely used systems. Additionally, the RU...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.13006
更新日期:2020-10-01 00:00:00
abstract::Dental amalgams are a common source of artifacts in head and neck (HN) images. Commercial artifact reduction techniques have been offered, but are substantially ineffectual at reducing artifacts from dental amalgams, can produce additional artifacts, provide inaccurate HU information, or require extensive computation ...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12922
更新日期:2020-08-01 00:00:00
abstract::This is a proof-of-concept study demonstrating the capacity for modulated electron radiation therapy (MERT) dose distributions using 3D printed bolus. Previous reports have involved bolus design using an electron pencil beam model and fabrication using a milling machine. In this study, an in-house algorithm is present...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v15i4.4831
更新日期:2014-07-08 00:00:00
abstract::The purpose of this study was to compare dosimetric parameters of treatment plans among four techniques for preoperative single-fraction partial breast radiotherapy in order to select an optimal treatment technique. The techniques evaluated were noncoplanar 3D conformal radiation therapy (3D CRT), noncoplanar intensit...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v16i1.5126
更新日期:2015-01-08 00:00:00
abstract::A thermobrachytherapy surface applicator (TBSA) was developed for simultaneous heat and brachytherapy treatment of chest wall (CW) recurrence of breast cancer. The ability to comfortably secure the applicator over the upper torso relative to the CW target throughout treatment is assessed on volunteers. Male and postma...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v13i5.3845
更新日期:2012-09-06 00:00:00
abstract::Hepatic encephalopathy (HE) is normally diagnosed by neuropsychological (NP) tests, which are not very specific and do not reveal the underlying pathology. Magnetic resonance imaging (MRI) and spectroscopy (MRS) of the brain offer alternative and possibly more specific markers for HE. These methods were applied in con...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v7i1.2151
更新日期:2006-01-01 00:00:00
abstract::This work illustrates a procedure to assess the overall accuracy associated with Gamma Knife treatment planning using plugging. The main role of source plugging or blocking is to create dose falloff in the junction between a target and a critical structure. We report the use of MAGAT gel dosimeter for verification of ...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v13i6.3877
更新日期:2012-11-08 00:00:00
abstract:PURPOSE:Segmentation of liver organ and tumors from computed tomography (CT) scans is an important task for hepatic surgical planning. Manual segmentation of liver and tumors is tedious, time-consuming, and biased to the clinician experience. Therefore, automatic segmentation of liver and tumors is highly desirable. It...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.13003
更新日期:2020-10-01 00:00:00
abstract::We have developed a method to improve the setup accuracy of a Varian Clinac 6/100 couch for delivering conformal arc therapy using a tertiary micro multileaf collimator (MLC) system. Several immobilization devices have been developed to improve the mechanical stability and isocenter alignment of the couch: turn-knob h...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v5i3.2026
更新日期:2004-07-01 00:00:00
abstract::Shewhart control charts have previously been suggested as a process control tool for use in routine linear accelerator (linac) output verifications. However, a comprehensive approach to process control has not been investigated for linac output verifications. The purpose of this work is to investigate a comprehensive ...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v14i1.4032
更新日期:2013-01-07 00:00:00
abstract::Multileaf collimator (MLC) tracking represents a promising technique for motion management in radiotherapy. However, the conflict between limited leaf speed/acceleration and the demand for tracking fast target motion is now a prominent issue. Conventional MLCs typically have a maximum leaf speed of 3-4 cm/s and a maxi...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12026
更新日期:2017-01-01 00:00:00
abstract::The purpose was to study correlations amongst IMRT DVH evaluation points and how their relaxation impacts the overall plan. 100 head-and-neck cancer cases, using the Eclipse treatment planning system with the same protocol, are statisti-cally analyzed for PTV, brainstem, and spinal cord. To measure variations amongst ...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v17i6.6411
更新日期:2016-11-08 00:00:00
abstract::The purpose of this study was to evaluate the dose differences introduced by the TMR 10 and the convolution dose calculation algorithms in GammaPlan version 10, as compared to the TMR classic algorithm in the previous versions of GammaPlan. Computed axial tomographic images of a polystyrene phantom and a human head we...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v15i5.4844
更新日期:2014-09-08 00:00:00
abstract::Radiographic film dosimetry provides fast, convenient 2-D dose distributions, but is challenged by the dependence of film response on scatter conditions (i.e., energy dependence). Verification of delivered dose in the surface buildup region is important for intensity modulated radiation therapy (IMRT) when volumes of ...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v9i4.2782
更新日期:2008-10-24 00:00:00
abstract::Increasingly, the advent of multislice CT scanners, volume CT scanners, and total body spiral acquisition modes has led to the use of Multi Planar Reconstruction and 3D datasets. In considering 3D resolution properties of a CT system it is important to note that both the in-plane (x,y) and z-axis (slice thickness) inf...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v17i5.6294
更新日期:2016-09-08 00:00:00
abstract:PURPOSE:Targeting and tracking of central lung tumors may be feasible on the Elekta MRI-linac (MRL) due to the soft-tissue visualization capabilities of MRI. The purpose of this work is to develop a novel treatment planning methodology to simulate tracking of central lung tumors with the MRL and to quantify the benefit...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12233
更新日期:2018-01-01 00:00:00
abstract::The use of a radioactive check device containing Strontium 90 was investigated to carry out the redundancy checks of Farmer-type ionization chambers. It was not possible to meet the recommended tolerance limits of the redundancy checks without taking into account the angular response of the ionization chambers. The io...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v1i4.2636
更新日期:2000-10-01 00:00:00
abstract:INTRODUCTION:Designing a radiation plan that optimally delivers both target coverage and normal tissue sparing is challenging. There are limited tools to determine what is dosimetrically achievable and frequently the experience of the planner/physician is relied upon to make these determinations. PlanIQ software provid...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12165
更新日期:2017-09-01 00:00:00
abstract::We investigate the sensitivity of IMRT commissioning using the TG-119 C-shape phantom and credentialing with the IROC head and neck phantom to treatment planning system commissioning errors. We introduced errors into the various aspects of the commissioning process for a 6X photon energy modeled using the analytical a...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v17i1.5452
更新日期:2016-01-08 00:00:00
abstract::The purpose of the present study was to use a kilovoltage imaging device to measure interfractional and intrafractional setup deviations in patients with head-and-neck or brain cancers receiving intensity-modulated radiotherapy (IMRT) treatment. Before and after IMRT treatment, approximately 3 times weekly, 7 patients...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v8i4.2439
更新日期:2007-09-24 00:00:00
abstract:PURPOSE:This study evaluates the feasibility of lung dose prediction based on target contour and patient anatomy for breast patients treated with proton therapy. METHODS:Fifty-two randomly selected patients were included in the cohort, who were treated to 50.4-66.4 Gy(RBE) to the left (36), right (15), or bilateral (1...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章,随机对照试验
doi:10.1002/acm2.12436
更新日期:2018-11-01 00:00:00
abstract::Stereotactic body radiotherapy (SBRT) of lung tumors via the ring-mounted Halcyon Linac, a fast kilovoltage cone beam CT-guided treatment with coplanar geometry, a single energy 6MV flattening filter free (FFF) beam and volumetric modulated arc therapy (VMAT) is a fast, safe, and feasible treatment modality for select...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.13146
更新日期:2020-12-20 00:00:00
abstract:OBJECTIVES:To evaluate the influence of MRI scanning parameters on texture analysis features. METHODS:Publicly available data from the Reference Image Database to Evaluate Therapy Response (RIDER) project sponsored by The Cancer Imaging Archive included MRIs on a phantom comprised of 18 25-mm doped, gel-filled tubes, ...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12482
更新日期:2018-11-01 00:00:00
abstract:PURPOSE:The aim of the current study was to evaluate the backscatter dose and energy spectrum from the Lipiodol with flattening filter (FF) and flattening filter-free (FFF) beams. Moreover, the backscatter range, that was defined as the backscatter distance (BD) are revealed. METHODS:6 MVX FF and FFF beams were delive...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12560
更新日期:2019-06-01 00:00:00
abstract::Substantial disagreement exists over appropriate PET segmentation techniques for non-small cell lung cancer. Currently, no segmentation algorithm explicitly considers tumor motion in determining tumor borders. We developed an automatic PET segmentation model as a function of target volume, motion extent, and source-to...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v15i1.4600
更新日期:2014-01-06 00:00:00
abstract:PURPOSE:Beam matching occurs on all linacs to some degree and when two are more are matched to each other, patients are able to be transferred between machines. Quality assurance of plans can also be performed "distributively" on any of the matched linacs. The degree to which machines are matched and how this translate...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12567
更新日期:2019-04-01 00:00:00