Comparison of three mechanical thrombus removal devices in thrombosed canine iliac arteries.

Abstract:

PURPOSE:To assess and compare intimal and medial vascular damage caused by three mechanical wall-contact thrombectomy devices: Fogarty embolectomy catheter, Arrow-Trerotola peripheral thrombectomy device, and MTI-Castañeda over-the-wire brush. MATERIALS AND METHODS:Bilateral external iliac arteries of 15 canines were thrombosed before mechanical thrombolysis. Ten thrombosed arteries were randomly assigned to receive each device. Animals were sacrificed immediately, and histologic assessment of endothelial and medial damage in the vessels was performed. RESULTS:The vascular damage found with all devices extended into the tunica media. The Fogarty embolectomy catheter and the Arrow-Trerotola device caused significantly more damage than the Castañeda brush. CONCLUSION:All devices caused lesions extending into the media. Previous research has shown that the extent and depth of the vascular lesion may be contributing factors in promoting early atherosclerotic and accelerated hyperplastic intimal and medial changes. These findings warrant further study of these devices in an atherosclerotic model with longer follow-up.

journal_name

Radiology

journal_title

Radiology

authors

Castañeda F,Li R,Patel J,DeBord JR,Swischuk JL

doi

10.1148/radiology.219.1.r01ap36153

subject

Has Abstract

pub_date

2001-04-01 00:00:00

pages

153-6

issue

1

eissn

0033-8419

issn

1527-1315

journal_volume

219

pub_type

杂志文章
  • Method to control spraying of high-velocity infected blood droplets during arterial catheterization.

    abstract::Spurting of blood from standard arterial needles during guide-wire insertion can be controlled easily with a syringe and a simple needle inserted along the syringe plunger. With this method, blood droplets that may be infected with the hepatitis or human immunodeficiency virus will not come into contact with the head ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.174.3.174-3-1055

    authors: Cope C,Machan L

    更新日期:1990-03-01 00:00:00

  • Radiologic criteria of retropharyngeal lymph node metastasis in nasopharyngeal carcinoma treated with radiation therapy.

    abstract:PURPOSE:To determine the appropriate radiologic criteria of metastatic retropharyngeal lymph nodes (RLNs) in patients with nasopharyngeal carcinoma (NPC). MATERIALS AND METHODS:After institutional review board approval and informed consent, 303 consecutive NPC patients treated with definitive radiation therapy were ex...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.10090289

    authors: Zhang GY,Liu LZ,Wei WH,Deng YM,Li YZ,Liu XW

    更新日期:2010-05-01 00:00:00

  • Lung torsion: case report and literature review.

    abstract::A 65-year-old woman with endobronchial carcinoma had torsion of the left upper lobe. A posteroanterior chest radiograph showed apparent atelectasis in the left upper lobe, but the lateral view disclosed an inappropriate posterior displacement of the collapsed lobe. The vasculature of the affected area showed an unusua...

    journal_title:Radiology

    pub_type: 杂志文章,评审

    doi:10.1148/radiology.162.3.3544030

    authors: Moser ES Jr,Proto AV

    更新日期:1987-03-01 00:00:00

  • Transcatheter occlusion of pulmonary arterial circulation and collateral supply: failures, incidents, and complications.

    abstract::Failures and complications were analyzed retrospectively in 45 patients treated with embolotherapy or occlusion of pulmonary arterial circulation. Pulmonary arterial branches were occluded with steel coils in 19 patients with pulmonary arteriovenous malformations, 17 with hemoptysis of pulmonary artery (PA) origin, an...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.180.3.1871280

    authors: Remy-Jardin M,Wattinne L,Remy J

    更新日期:1991-09-01 00:00:00

  • Vein graft function improvement after percutaneous intervention: evaluation with MR flow mapping.

    abstract:PURPOSE:To provide functional reference values in single and sequential vein grafts by using magnetic resonance (MR) flow mapping and to examine the effect of percutaneous intervention (PCI) on coronary artery bypass graft function. MATERIALS AND METHODS:Fast MR flow mapping at baseline and during adenosine-induced st...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2283020305

    authors: Langerak SE,Vliegen HW,Jukema JW,Zwinderman AH,Lamb HJ,de Roos A,van der Wall EE

    更新日期:2003-09-01 00:00:00

  • The scanning grid: a novel and effective bucky movement.

    abstract::A grid consisting of a focused array of radiopaque strips has been constructed. No interspace material is employed, and, during an exposure, the arrangement moves so that the grid strips remain focused and a uniform film density is obtained. Preliminary measurements and radiographs of patients indicate that such a dev...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.135.3.7384470

    authors: Barnes GT,Moreland RF,Yester MV,Witten DM

    更新日期:1980-06-01 00:00:00

  • Lead arthropathy: arthritis caused by retained intra-articular bullets.

    abstract::The cases of 14 patients seen 6 weeks to 7 years after gunshot wounds with painful, restrictive joint disease and retained intra-articular bullets were reviewed. Twelve patients had radiographic findings characteristic of lead synovitis. The earliest finding was a fine, punctate deposition of radiopaque lead on the ar...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.156.2.4011890

    authors: Sclafani SJ,Vuletin JC,Twersky J

    更新日期:1985-08-01 00:00:00

  • Internal derangement of the temporomandibular joint: detection by single-photon emission computed tomography. Work in progress.

    abstract::The diagnostic accuracy of both planar and single-photon emission computed tomography (SPECT) bone scintigraphy, radionuclide angiography, arthrography, and conventional radiography was evaluated in 36 patients with temporomandibular joint (TMJ) dysfunction undergoing preoperative testing. The sensitivity of SPECT bon...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.149.2.6226060

    authors: Collier BD,Carrera GF,Messer EJ,Ryan DE,Gingrass D,Angell D,Palmer DW,Isitman AT,Hellman RS

    更新日期:1983-11-01 00:00:00

  • Radiofrequency Ablation, MR Thermometry, and High-Spatial-Resolution MR Parametric Imaging with a Single, Minimally Invasive Device.

    abstract::Purpose To develop and demonstrate in vitro and in vivo a single interventional magnetic resonance (MR)-active device that integrates the functions of precise identification of a tissue site with the delivery of radiofrequency (RF) energy for ablation, high-spatial-resolution thermal mapping to monitor thermal dose, a...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2016151447

    authors: Ertürk MA,Sathyanarayana Hegde S,Bottomley PA

    更新日期:2016-12-01 00:00:00

  • Subcutaneous granuloma annulare: MR imaging features in six children and literature review.

    abstract:PURPOSE:To describe the magnetic resonance (MR) imaging findings of subcutaneous granuloma annulare (SGA), a rare mass of early childhood. MATERIALS AND METHODS:MR imaging studies and clinical records in six children aged 2 1/2-4 years in whom SGA was diagnosed between 1993 and 1997 were retrospectively reviewed. All ...

    journal_title:Radiology

    pub_type: 杂志文章,评审

    doi:10.1148/radiology.210.3.r99mr11845

    authors: Chung S,Frush DP,Prose NS,Shea CR,Laor T,Bisset GS

    更新日期:1999-03-01 00:00:00

  • Neoplastic invasion of the laryngeal cartilage: comparison of MR imaging and CT with histopathologic correlation.

    abstract:PURPOSE:To compare the usefulness of computed tomography (CT) and gadolinium-enhanced magnetic resonance (MR) imaging in the detection of neoplastic invasion of laryngeal cartilage. MATERIALS AND METHODS:In a prospective study, 53 patients with carcinoma of the larynx or piriform sinus underwent CT and MR imaging befo...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.194.3.7862960

    authors: Becker M,Zbären P,Laeng H,Stoupis C,Porcellini B,Vock P

    更新日期:1995-03-01 00:00:00

  • Step-wedge sensitometry.

    abstract::An aluminum step-wedge filter placed far from the film cassette provides the constant variation of subject contrast required for quantitative sensitometry while virtually eliminating scatter radiations. Attenuation curves made with this configuration are almost exponentially linear. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/128.3.820

    authors: Hale J,Bloch P

    更新日期:1978-09-01 00:00:00

  • MR imaging of silicone breast implants: comparison of different coil arrays.

    abstract::To determine the optimal coil and patient position for magnetic resonance imaging of patients with silicone breast implants, images obtained with body, circular surface, flexible, single shoulder, and dual shoulder coils in various numbers of patients were compared with regard to signal-to-noise ratio (S/N), decay of ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.187.1.8451430

    authors: Sinha S,Gorczyca DP,DeBruhl ND,Shellock FG,Gausche VR,Bassett LW

    更新日期:1993-04-01 00:00:00

  • Musculoskeletal infection of the extremities: evaluation with MR imaging.

    abstract::Magnetic resonance (MR) imaging was performed in 17 patients, 11-84 years of age, referred for evaluation of possible osteomyelitis involving the appendicular skeleton. MR imaging permitted successful identification of osteomyelitis in ten patients (four acute, two subacute with Brodie abscess, two chronic, and two ac...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.166.1.3336680

    authors: Tang JS,Gold RH,Bassett LW,Seeger LL

    更新日期:1988-01-01 00:00:00

  • Digital subtraction angiography for examination of vessels of the leg: use of a 40-cm image intensifier.

    abstract::Digital subtraction angiography (DSA) using a 41-cm (16-in.) image intensifier was performed in 144 patients with peripheral vascular insufficiency. In most cases the entire peripheral vascular bed from the renal arteries to the popliteal trifurcation was demonstrated with four intravenous injections and four exposed ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.149.3.6359260

    authors: Passariello R,Rossi P,Simonetti G,Tempesta P,Pavone P,Castrucci M,McBride K

    更新日期:1983-12-01 00:00:00

  • Science to Practice: What Causes Arterial Infarction in Transforaminal Epidural Steroid Injections, and Which Steroid Is Safest?

    abstract::Transforaminal epidural steroid injections (TFESIs) are associated with rare but devastating neurologic complications. Every published case has been associated with a particulate steroid suspension, and the presumed but not proven mechanism is embolization and occlusion of end arterioles. Through an in vivo murine mod...

    journal_title:Radiology

    pub_type: 评论,杂志文章

    doi:10.1148/radiol.2016160171

    authors: Diehn FE,Murthy NS,Maus TP

    更新日期:2016-06-01 00:00:00

  • Angiographic abnormalities in partial Budd-Chiari syndrome.

    abstract::Partial Budd-Chiari syndrome was produced in 8 monkeys by obstructing 2 or 3 lobar hepatic veins with a rapidly polymerizing plastic. Hepatic angiography done 1-3 months later revealed crowded tortuous arteries and a dense hepatogram in the lobe with venous occlusion. Unobstructed lobes were hypertrophied. Retrograde ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/122.3.629

    authors: Maguire R,Doppman JL

    更新日期:1977-03-01 00:00:00

  • Postnatal development of the central skull base: normal variants.

    abstract:PURPOSE:To illustrate the normal variants and developmental anomalies of the skull base on computed tomographic (CT) scans. MATERIALS AND METHODS:One hundred eighty-nine children (age range, newborn to 18 years; median age, 4.0 years) without skull base deformity were referred for cranial CT. Normal developmental vari...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.196.3.7644640

    authors: Madeline LA,Elster AD

    更新日期:1995-09-01 00:00:00

  • Angiography in the diagnosis and therapy of frostbite.

    abstract::Five patients with frostbite injury were studied by selective angiography and treated by selective intra-arterial application of reserpine with follow-up angiography two days later. Control angiograms showed various degrees of vascular spasm as well as organic stenosis and occlusion. Intra-arterial reserpine produced ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/119.2.301

    authors: Gralino BJ,Porter JM,Rosch J

    更新日期:1976-05-01 00:00:00

  • MR-guided percutaneous intramyocardial injection with an MR-compatible catheter: feasibility and changes in T1 values after injection of extracellular contrast medium in pigs.

    abstract:PURPOSE:To assess the feasibility of percutaneous magnetic resonance (MR)-guided intramyocardial injection of gadodiamide by using real-time imaging and to quantify T1 values and the size of the enhanced region for different concentrations of contrast agent for 30 minutes after injection. MATERIALS AND METHODS:Animal ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2352031760

    authors: Krombach GA,Pfeffer JG,Kinzel S,Katoh M,Günther RW,Buecker A

    更新日期:2005-05-01 00:00:00

  • Malignant astrocytic tumors: clinical importance of apparent diffusion coefficient in prediction of grade and prognosis.

    abstract:PURPOSE:To retrospectively assess the apparent diffusion coefficient (ADC) for prediction of malignancy and prognosis of malignant astrocytic tumors. MATERIALS AND METHODS:The institutional review board approved this study and did not require patient informed consent. Findings from 37 consecutive patients (21 men, 16 ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2413051276

    authors: Higano S,Yun X,Kumabe T,Watanabe M,Mugikura S,Umetsu A,Sato A,Yamada T,Takahashi S

    更新日期:2006-12-01 00:00:00

  • Evaluation of Low-Contrast Detectability of Iterative Reconstruction across Multiple Institutions, CT Scanner Manufacturers, and Radiation Exposure Levels.

    abstract:PURPOSE:To compare image resolution from iterative reconstruction with resolution from filtered back projection for low-contrast objects on phantom computed tomographic (CT) images across vendors and exposure levels. MATERIALS AND METHODS:Randomized repeat scans of an American College of Radiology CT accreditation pha...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2015141260

    authors: Saiprasad G,Filliben J,Peskin A,Siegel E,Chen J,Trimble C,Yang Z,Christianson O,Samei E,Krupinski E,Dima A

    更新日期:2015-10-01 00:00:00

  • Evaluation of fetal midface anatomy related to facial clefts: use of US.

    abstract:PURPOSE:To identify the sonographic appearance of normal fetal midface anatomy of in vitro fetal specimens and to correlate the appearance with that of in utero fetuses to determine which aspects of this anatomy can be evaluated clinically. MATERIALS AND METHODS:The midface structures of 12 normal fetal specimens were...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.201.1.8816530

    authors: Babcook CJ,McGahan JP,Chong BW,Nemzek WR,Salamat MS

    更新日期:1996-10-01 00:00:00

  • Ultrasound mammography for the augmented breast.

    abstract::Ultrasound examinations were performed on 25 women with augmented breasts using whole-breast water-path scanning. In these patients, ultrasound imaged carcinoma, benign lesions, and fibrous capsule formation; these were confirmed by surgery. In addition, it was noted that certain prostheses appeared to be displaced po...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.146.3.6828690

    authors: Cole-Beuglet C,Schwartz G,Kurtz AB,Patchefsky AS,Goldberg BB

    更新日期:1983-03-01 00:00:00

  • Pancreatic acinar cell carcinoma with subcutaneous and intraosseous fat necrosis.

    abstract::On rare occasions, excessive lipase production by functioning pancreatic acinar cell carcinoma results in subcutaneous and intraosseous fat necrosis. A patient with subcutaneous nodules and osteolytic lesions from metastatic fat necrosis associated with this malignancy is reported. Prompt recognition of the syndrome l...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.158.1.3940400

    authors: Radin DR,Colletti PM,Forrester DM,Tang WW

    更新日期:1986-01-01 00:00:00

  • T1 hyperintense renal lesions: characterization with diffusion-weighted MR imaging versus contrast-enhanced MR imaging.

    abstract:PURPOSE:To compare the performance of apparent diffusion coefficient (ADC) measurement obtained with diffusion-weighted (DW) magnetic resonance (MR) imaging in the characterization of non-fat-containing T1 hyperintense renal lesions with that of contrast material-enhanced MR imaging, with histopathologic analysis and f...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2513080724

    authors: Kim S,Jain M,Harris AB,Lee VS,Babb JS,Sigmund EE,Rueff LE,Taouli B

    更新日期:2009-06-01 00:00:00

  • Cranial imaging in autosomal recessive osteopetrosis. Part II. Skull base and brain.

    abstract::The authors reviewed cranial imaging studies (radiographs, computed tomographic scans, and magnetic resonance [MR] images) in 13 infants and children with the autosomal recessive form of osteopetrosis to characterize patterns of skull base, brain, and cranial nerve involvement at presentation and with progression of d...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.183.1.1549660

    authors: Elster AD,Theros EG,Key LL,Chen MY

    更新日期:1992-04-01 00:00:00

  • Evaluation of the aortoiliac and renal arteries: comparison of breath-hold, contrast-enhanced, three-dimensional MR angiography with conventional catheter angiography.

    abstract:PURPOSE:To determine the diagnostic accuracy of breath-hold, contrast material-enhanced, three-dimensional (3D) magnetic resonance (MR) angiography in the assessment of the aortoiliac inflow tract and renal arteries with conventional catheter angiography as the standard of reference. MATERIALS AND METHODS:In 39 patien...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.204.2.9240520

    authors: Hany TF,Debatin JF,Leung DA,Pfammatter T

    更新日期:1997-08-01 00:00:00

  • Ventilator-associated Pseudomonas aeruginosa pneumonia: radiographic findings.

    abstract:PURPOSE:To characterize the radiographic features of ventilator-associated Pseudomonas aeruginosa pneumonia (PAP). MATERIALS AND METHODS:In 56 patients (40 men and 16 women), PAP was documented with fiberoptic bronchoscopy. All patients underwent mechanical ventilation for at least 48 hours before diagnosis. The findi...

    journal_title:Radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1148/radiology.195.1.7892480

    authors: Winer-Muram HT,Jennings SG,Wunderink RG,Jones CB,Leeper KV Jr

    更新日期:1995-04-01 00:00:00

  • Ultra-low peak voltage CT colonography: effect of iterative reconstruction algorithms on performance of radiologists who use anthropomorphic colonic phantoms.

    abstract:PURPOSE:To analyze the effect of a decrease in computed tomographic (CT) colonographic voltage, from 100 and 120 kVp to 80 kVp and reconstructed with filtered back projection ( FBP filtered back projection ), on radiation dose, image noise, and diagnostic performance in anthropomorphic phantoms and to assess the effect...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.14140192

    authors: Shin CI,Kim SH,Lee ES,Lee DH,Hwang EJ,Chung SY,Lee JM,Han JK,Choi BI

    更新日期:2014-12-01 00:00:00