Vein graft function improvement after percutaneous intervention: evaluation with MR flow mapping.

Abstract:

PURPOSE:To provide functional reference values in single and sequential vein grafts by using magnetic resonance (MR) flow mapping and to examine the effect of percutaneous intervention (PCI) on coronary artery bypass graft function. MATERIALS AND METHODS:Fast MR flow mapping at baseline and during adenosine-induced stress was performed in 39 nonstenotic single vein grafts and 20 nonstenotic sequential vein grafts, as well as in 15 stenotic vein grafts before and 7.3 weeks +/- 1.5 after successful PCI. We evaluated the following parameters (in terms of mean values +/- SDs): average peak velocity (APV) at baseline, stress APV, and velocity reserve. Parameters in nonstenotic single and sequential vein grafts were compared by means of unpaired two-tailed Student t testing. To evaluate changes in velocities before and after PCI, a paired two-tailed Student t test was used. P <.05 was considered to indicate a statistically significant difference. RESULTS:Reference values in single vein grafts for baseline APV, stress APV, and velocity reserve were 8.6 cm/sec +/- 3.4, 20.2 cm/sec +/- 9.5, and 2.4 +/- 0.8, respectively. In sequential vein grafts, significantly higher values for baseline APV (12.2 cm/sec +/- 5.0) and stress APV (27.2 cm/sec +/- 10.6) but a similar velocity reserve (2.3 +/- 0.7) were found. Significant improvements were observed after PCI in baseline APV (before PCI: 9.2 cm/sec +/- 6.6; after PCI: 12.9 cm/sec +/- 7.9; P =.008) and stress APV (before PCI: 12.9 cm/sec +/- 6.3; after PCI: 27.1 cm/sec +/- 13.9; P <.001). No improvement in velocity reserve was observed. CONCLUSION:Significantly higher absolute velocity and flow values were observed in sequential versus single vein grafts, underscoring the need for separate functional reference values for different graft types. Graft function showed significant improvement after PCI to the point that it was restored or nearly restored to reference values.

journal_name

Radiology

journal_title

Radiology

authors

Langerak SE,Vliegen HW,Jukema JW,Zwinderman AH,Lamb HJ,de Roos A,van der Wall EE

doi

10.1148/radiol.2283020305

subject

Has Abstract

pub_date

2003-09-01 00:00:00

pages

834-41

issue

3

eissn

0033-8419

issn

1527-1315

pii

228/3/834

journal_volume

228

pub_type

杂志文章
  • Women with breast cancer: histologic findings in the contralateral breast.

    abstract:PURPOSE:To investigate contralateral breast biopsy histologic findings in women with breast cancer. MATERIALS AND METHODS:Histologic findings in 237 patients with breast cancer who underwent contralateral breast biopsy for clinically or mammographically detected abnormalities were retrospectively reviewed. Malignant f...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.203.3.9169690

    authors: Roubidoux MA,Helvie MA,Wilson TE,Lai NE,Paramagul C

    更新日期:1997-06-01 00:00:00

  • MR-compatible assistance system for biopsy in a high-field-strength system: initial results in patients with suspicious prostate lesions.

    abstract:PURPOSE:To examine the feasibility and safety of magnetic resonance (MR)-guided biopsy by using a transgluteal approach in patients with suspicious prostate lesions by using an MR-compatible robotic system and a 1.5-T MR system. MATERIALS AND METHODS:The study was approved by the institutional review board of Universi...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.11101559

    authors: Zangos S,Melzer A,Eichler K,Sadighi C,Thalhammer A,Bodelle B,Wolf R,Gruber-Rouh T,Proschek D,Hammerstingl R,Müller C,Mack MG,Vogl TJ

    更新日期:2011-06-01 00:00:00

  • Characteristics of triangular fibrocartilage defects in symptomatic and contralateral asymptomatic wrists.

    abstract:PURPOSE:To characterize triangular fibrocartilage (TFC) defects in symptomatic and contralateral asymptomatic wrists. MATERIALS AND METHODS:Communicating and noncommunicating defects of the TFC were depicted on bilateral wrist arthrograms in 56 patients with unilateral wrist pain and without associated lesions of the ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.216.3.r00se06840

    authors: Zanetti M,Linkous MD,Gilula LA,Hodler J

    更新日期:2000-09-01 00:00:00

  • Developmental Hip Dysplasia Diagnosis at Three-dimensional US: A Multicenter Study.

    abstract::Purpose To validate accuracy of diagnosis of developmental dysplasia of the hip (DDH) from geometric properties of acetabular shape extracted from three-dimensional (3D) ultrasonography (US). Materials and Methods In this retrospective multi-institutional study, 3D US was added to conventional two-dimensional (2D) US ...

    journal_title:Radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1148/radiol.2018172592

    authors: Zonoobi D,Hareendranathan A,Mostofi E,Mabee M,Pasha S,Cobzas D,Rao P,Dulai SK,Kapur J,Jaremko JL

    更新日期:2018-06-01 00:00:00

  • Conventional and rapid MR imaging of the liver with Gd-DTPA.

    abstract::Twenty-three patients with malignant hepatic tumors underwent magnetic resonance (MR) imaging before and after intravenous administration of gadolinium-diethylene-triaminepentaacetic acid (DTPA). Two different doses were used, 0.1 mmol/kg and 0.2 mmol/kg. The larger dose proved to be more effective than the smaller do...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.164.2.3037590

    authors: Hamm B,Wolf KJ,Felix R

    更新日期:1987-08-01 00:00:00

  • High-grade acute organ toxicity as positive prognostic factor in adjuvant radiation and chemotherapy for locally advanced head and neck cancer.

    abstract:PURPOSE:To test for an association between high-grade acute organ toxicity during adjuvant radiation and chemotherapy and treatment outcome in patients with locally advanced head and neck squamous cell carcinoma (HNSCC). MATERIALS AND METHODS:Institutional review board approval was obtained for this retrospective stud...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.10100705

    authors: Wolff HA,Daldrup B,Jung K,Overbeck T,Hennies S,Matthias C,Hess CF,Roedel RM,Christiansen H

    更新日期:2011-03-01 00:00:00

  • Amiodarone pulmonary toxicity: CT findings in symptomatic patients.

    abstract::The computed tomographic (CT) chest scans of 11 patients who developed respiratory or constitutional symptoms while receiving amiodarone therapy were reviewed. CT findings indicative of significant amiodarone exposure included (a) high-attenuation parenchymal-pleural lesions in eight of the 11 patients (73%), and (b) ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.177.1.2399310

    authors: Kuhlman JE,Teigen C,Ren H,Hruban RH,Hutchins GM,Fishman EK

    更新日期:1990-10-01 00:00:00

  • Noninvasive quantification of airway inflammation following segmental allergen challenge with functional MR imaging: a proof of concept study.

    abstract:PURPOSE:To evaluate oxygen-enhanced T1-mapping magnetic resonance (MR) imaging as a noninvasive method for visualization and quantification of regional inflammation after segmental allergen challenge in asthmatic patients compared with control subjects. MATERIALS AND METHODS:After institutional review board approval, ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.14132607

    authors: Renne J,Hinrichs J,Schönfeld C,Gutberlet M,Winkler C,Faulenbach C,Jakob P,Schaumann F,Krug N,Wacker F,Hohlfeld JM,Vogel-Claussen J

    更新日期:2015-01-01 00:00:00

  • Case 253: Thrombosed Umbilical Venous Varix in an Infant.

    abstract::History A 3-month-old previously healthy girl presented to an outside institution with a 4-day history of low-grade fever, irritability, and a tender "knot" in the upper abdomen. Ultrasonography (US) was performed at an outside hospital. US images were not available for review; however, they showed a mass in the left ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2018160106

    authors: Sandberg JK,Hulett-Bowling R,Khanna G

    更新日期:2018-05-01 00:00:00

  • Breast lesions: evaluation with US strain imaging--clinical experience of multiple observers.

    abstract:PURPOSE:To prospectively determine the accuracy of using an ultrasonographic (US) strain imaging technique known as lesion size comparison to differentiate benign from malignant breast lesions. MATERIALS AND METHODS:Institutional Review Board approval and patient informed consent were obtained for this HIPPA-compliant...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2381041336

    authors: Regner DM,Hesley GK,Hangiandreou NJ,Morton MJ,Nordland MR,Meixner DD,Hall TJ,Farrell MA,Mandrekar JN,Harmsen WS,Charboneau JW

    更新日期:2006-02-01 00:00:00

  • Percutaneous adrenal biopsy: review of a 10-year experience.

    abstract:PURPOSE:To evaluate the indications for and complications, accuracy, and techniques of percutaneous adrenal biopsy performed from 1982 through 1991 at the authors' institution. MATERIALS AND METHODS:Two hundred seventy-seven percutaneous adrenal biopsies were performed in 270 patients (175 male and 102 female patients...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.193.2.7972740

    authors: Welch TJ,Sheedy PF 2nd,Stephens DH,Johnson CM,Swensen SJ

    更新日期:1994-11-01 00:00:00

  • Sarcoidosis: abdominal manifestations at CT.

    abstract::There are few data in the literature on the abdominal manifestations of sarcoidosis at computed tomography (CT). To determine whether differences in nodal distribution and appearance can be reliably used to distinguish between sarcoidosis and non-Hodgkin lymphoma (NHL), the authors retrospectively reviewed the abdomin...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.178.1.1984330

    authors: Britt AR,Francis IR,Glazer GM,Ellis JH

    更新日期:1991-01-01 00:00:00

  • Experimental design and data analysis in receiver operating characteristic studies: lessons learned from reports in radiology from 1997 to 2006.

    abstract:PURPOSE:To provide a broad perspective concerning the recent use of receiver operating characteristic (ROC) analysis in medical imaging by reviewing ROC studies published in Radiology between 1997 and 2006 for experimental design, imaging modality, medical condition, and ROC paradigm. MATERIALS AND METHODS:Two hundred...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2533081632

    authors: Shiraishi J,Pesce LL,Metz CE,Doi K

    更新日期:2009-12-01 00:00:00

  • Subcortical damage and cortical functional changes in men and women with Fabry disease: a multifaceted MR study.

    abstract:PURPOSE:To prospectively compare brain magnetic resonance (MR) imaging and hydrogen 1 (1H) MR spectroscopy findings and to use functional MR imaging to explore the patterns of brain activation in men and women with Fabry disease (FD). MATERIALS AND METHODS:Eight men and eight women with FD (mean age, 38.8 years +/- 13...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2412051122

    authors: Gavazzi C,Borsini W,Guerrini L,Della Nave R,Rocca MA,Tessa C,Buchner S,Belli G,Filippi M,Villari N,Mascalchi M

    更新日期:2006-11-01 00:00:00

  • Surface coil assembly with switchable field of view.

    abstract::The authors designed and built an overlapping surface coil assembly for magnetic resonance imaging of the spine. A small and a large coil are included, and use of one can be switched to the other without need for patient repositioning. The images are not degraded, and screening studies can immediately be followed by d...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.164.3.3615890

    authors: Arakawa M,Krasnor S,Fehn J,McCarten B,Kaufman L

    更新日期:1987-09-01 00:00:00

  • Transrectal US as an adjunct in the diagnosis of rectal and extrarectal tumors.

    abstract::Transrectal ultrasound (US; also called endosonography) was used to evaluate known or suspected rectal and perirectal masses. Thirty-one patients were examined with commercially available endosonographic probes. Those who obtained and interpreted the sonograms had no knowledge of other diagnostic studies, which includ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.157.2.3901110

    authors: Rifkin MD,Marks GJ

    更新日期:1985-11-01 00:00:00

  • Lung abscess: CT-guided drainage.

    abstract::Lung abscesses were drained by means of catheters guided by computed tomography (CT) in 19 patients who still had sepsis despite standard medical therapy; all patients had received antibiotics for at least 5 days, and 11 of the 19 patients had undergone bronchoscopy. The abscess was cured (by clinical and radiographic...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.178.2.1987590

    authors: vanSonnenberg E,D'Agostino HB,Casola G,Wittich GR,Varney RR,Harker C

    更新日期:1991-02-01 00:00:00

  • Malignant ureteral obstruction: treatment with metal stents--technique, results, and observations with percutaneous intraluminal US.

    abstract:PURPOSE:To test the technical feasibility and results of placement of metal stents into ureters obstructed by extensive tumor. MATERIALS AND METHODS:Six consecutive patients (two men and four women, aged 35-66 years and with incurable malignancies) underwent insertion of metallic endoprostheses in nine obstructed uret...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.191.3.8184060

    authors: vanSonnenberg E,D'Agostino HB,O'Laoide R,Donaldson J,Sanchez RB,Hoyt A,Pittman CC

    更新日期:1994-06-01 00:00:00

  • Computed tomography of intracranial ependymomas.

    abstract::It appears reasonable to suggest a histological diagnosis of ependymoma when CT shows an isodense tumor expanding the fourth ventricle or lying within its outlets; when the tumor contains small, round calcifications; and when presentation occurs early in life. An isodense mass occurring in the cerebral white matter, c...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.143.1.7063750

    authors: Swartz JD,Zimmerman RA,Bilaniuk LT

    更新日期:1982-04-01 00:00:00

  • Infantile hepatic hemangioendothelioma: a surviving case.

    abstract::A surviving case of infantile hepatic hemangioendothelioma is presented. The patient was treated with a combination of radiation therapy, cytotoxan, and prednisone, resulting in regression of the tumor. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/123.3.723

    authors: Tewfik H,Latourette H,Christie JH,Tewfik F

    更新日期:1977-06-01 00:00:00

  • High-Performance Automated Anterior Circulation CT Angiographic Clot Detection in Acute Stroke: A Multireader Comparison.

    abstract::Background Identification of large vessel occlusion (LVO) is critical to the management of acute ischemic stroke and prerequisite to endovascular therapy in recent trials. Increasing volumes and data complexity compel the development of fast, reliable, and automated tools for LVO detection to facilitate acute imaging ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2021202734

    authors: Dehkharghani S,Lansberg M,Venkatsubramanian C,Cereda C,Lima F,Coelho H,Rocha F,Qureshi A,Haerian H,Mont'Alverne F,Copeland K,Heit J

    更新日期:2021-01-12 00:00:00

  • Femoral MR angiography versus conventional angiography: preliminary results.

    abstract:PURPOSE:To develop a bilateral femoral magnetic resonance (MR) angiographic examination that would include the aortic bifurcation to the ankle. MATERIALS AND METHODS:Thirty-seven patients underwent conventional angiography and the bilateral femoral MR angiographic examination. Two-dimensional time-of-flight angiograph...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.189.1.8372190

    authors: Quinn SF,Demlow TA,Hallin RW,Eidemiller LR,Szumowski J

    更新日期:1993-10-01 00:00:00

  • Display of CT studies on a two-screen electronic workstation versus a film panel alternator: sensitivity and efficiency among radiologists.

    abstract::Prototype electronic workstations incorporated in networks linking computed tomographic (CT) and magnetic resonance imaging systems are being developed. The authors compared observer efficiency and sensitivity in reading body CT studies from a two-screen workstation (1,000-line monitors and 12-bit dynamic range in ima...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.174.3.2305060

    authors: Foley WD,Jacobson DR,Taylor AJ,Goodman LR,Stewart ET,Gurney JW,Stroka D

    更新日期:1990-03-01 00:00:00

  • Are two-dimensional CT measurements of small noncalcified pulmonary nodules reliable?

    abstract:PURPOSE:To evaluate the intra- and interreader agreement of two-dimensional computed tomographic (CT) measurements of pulmonary nodules less than 2 cm in diameter. MATERIALS AND METHODS:Three readers independently made three serial measurements of each of 54 pulmonary nodules measuring 3-18 mm that had been observed o...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2312030167

    authors: Revel MP,Bissery A,Bienvenu M,Aycard L,Lefort C,Frija G

    更新日期:2004-05-01 00:00:00

  • Acute pulmonary embolism: ancillary findings at spiral CT.

    abstract:PURPOSE:To determine the value of parenchymal findings at contrast material-enhanced spiral computed tomography (CT) in patients suspected to have pulmonary embolism (PE). MATERIALS AND METHODS:Eighty-eight patients suspected to have PE underwent contrast-enhanced spiral CT and ventilation-perfusion scintigraphy. Conc...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.207.3.9609900

    authors: Coche EE,Müller NL,Kim KI,Wiggs BR,Mayo JR

    更新日期:1998-06-01 00:00:00

  • Valve and great vessel stenosis: assessment with MR jet velocity mapping.

    abstract::For measurement of poststenotic jet velocities with magnetic resonance (MR) imaging, the authors reduced the echo time (TE) of the field even-echo rephasing (FEER) velocity mapping sequence from 14.0 to 3.6 msec, so minimizing the problem of MR signal loss from turbulent fluid. In vitro use of rotating disk and stenot...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.178.1.1984310

    authors: Kilner PJ,Firmin DN,Rees RS,Martinez J,Pennell DJ,Mohiaddin RH,Underwood SR,Longmore DB

    更新日期:1991-01-01 00:00:00

  • Gastric retention of zinc-based pennies: radiographic appearance and hazards.

    abstract:PURPOSE:To determine the radiographic appearance and features of corrosion in U.S. coins exposed to gastric acid. MATERIALS AND METHODS:Six U.S. copper-based pre-1982 pennies, 12 zinc-based post-1982 pennies, a quarter, a nickel, and a dime were exposed to postprandial concentrations of gastric acid (0.15N HCl) for 7 ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.213.1.r99oc36113

    authors: O'Hara SM,Donnelly LF,Chuang E,Briner WH,Bisset GS 3rd

    更新日期:1999-10-01 00:00:00

  • Bowel and mesenteric injury: evaluation with emergency abdominal US.

    abstract:PURPOSE:To assess emergency ultrasonography (US) for detection of bowel and mesenteric injury from blunt trauma. MATERIALS AND METHODS:For 3 years, prospective data on all patients undergoing emergency US were recorded. Patients with bowel and mesenteric injury were identified, and physical examination, laboratory, co...

    journal_title:Radiology

    pub_type: 临床试验,杂志文章

    doi:10.1148/radiology.211.2.r99ma54399

    authors: Richards JR,McGahan JP,Simpson JL,Tabar P

    更新日期:1999-05-01 00:00:00

  • Mediastinal tumors: biopsy under US guidance.

    abstract::Percutaneous biopsies of mediastinal tumors were successfully performed under sonographic guidance in 14 of 21 patients. In 10 of 11 malignant lesions, malignancy was determined by means of cytologic and histologic examination of the specimens obtained. A histologic diagnosis was reached in seven patients with maligna...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.172.2.2664870

    authors: Wernecke K,Vassallo P,Peters PE,von Bassewitz DB

    更新日期:1989-08-01 00:00:00

  • Anomalies of the intrahepatic portal venous system in congenital hepatic fibrosis.

    abstract::Duplication of intrahepatic venous channels was observed in 9 of 13 children with congenital hepatic fibrosis and portal hypertension. Portal hypertension due to other causes was not associated with venous duplication. This anomaly may be a distinctive feature of congenital hepatic fibrosis with portal hypertension. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/122.2.427

    authors: Odievre M,Chaumont P,Montagne JP,Alagille D

    更新日期:1977-02-01 00:00:00