Acrosclerosis in Sarcoidosis.

Abstract:

:Areas of sclerosis in the phalanges, particularly the terminal phalanges, are common in sarcoidosis despite the rarity of osteosclerotic changes in other bones. Of 37 patients with sarcoidosis with osseous changes of the hands or feet, 20 (54%) has sclerosis either alone or in combination with bone destruction. Of 48 patients with acrosclerosis, 20 (40%) had sarcoidosis. In the authors' experience with a largely black population, sarcoidosis was found to be the most common causes of acrosclerosis.

journal_name

Radiology

journal_title

Radiology

authors

McBrine CS,Fisher MS

doi

10.1148/115.2.279

subject

Has Abstract

pub_date

1975-05-01 00:00:00

pages

279-81

issue

2

eissn

0033-8419

issn

1527-1315

journal_volume

115

pub_type

杂志文章
  • Hippocampal Calcifications: Risk Factors and Association with Cognitive Function.

    abstract::Purpose To identify risk factors for hippocampal calcifications and to investigate the association between hippocampal calcifications and cognitive function. Materials and Methods For this retrospective study, consecutive patients visiting a memory clinic at a Dutch general hospital between April 2009 and April 2015 w...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2018172588

    authors: de Brouwer EJM,Kockelkoren R,Claus JJ,de Jonghe A,Geerlings MI,Jongsma TEF,Mali WPTM,Hendrikse J,de Jong PA,Koek HL

    更新日期:2018-09-01 00:00:00

  • Catheter and material selection for transarterial embolization: technical considerations. II. Materials.

    abstract::In this second part of the report, the authors discuss the advantages and disadvantages of several embolization agents. These include Gelfoam, silicone spheres, polyvinyl alcohol foam (PVA), isobutyl-2-cyanoacrylate (IBCA), silicone fluid mixtures, and tantalum powder. The techniques employed and conditions under whic...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/132.3.631

    authors: Berenstein A,Kricheff II

    更新日期:1979-09-01 00:00:00

  • Pelvimetry by digital radiography: a low-dose examination.

    abstract::Digital radiographs obtained with a CT scanner were evaluated as an alternative to conventional pelvimetry. Dosimetry studies demonstrated an absorbed radiation dose of 22 mrad for each digital radiograph, approximately 3% of the dose for comparable standard radiographs. Distance measurements were accurately made on d...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.143.3.7079500

    authors: Federle MP,Cohen HA,Rosenwein MF,Brant-Zawadzki MN,Cann CE

    更新日期:1982-06-01 00:00:00

  • Automatic quantitative left ventricular analysis of cine MR images by using three-dimensional information for contour detection.

    abstract::The purpose of this study was to evaluate an automatic boundary detection algorithm of the left ventricle on magnetic resonance (MR) short-axis images with the essential restriction of no manual corrections. The study comprised 13 patients (nine men, four women) and 12 healthy volunteers (11 men, one woman), and insti...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2401050471

    authors: van Geuns RJ,Baks T,Gronenschild EH,Aben JP,Wielopolski PA,Cademartiri F,de Feyter PJ

    更新日期:2006-07-01 00:00:00

  • Error patterns in the MR imaging evaluation of menisci of the knee.

    abstract:PURPOSE:To categorize errors in interpretation of magnetic resonance (MR) images of the knee and explain the discrepancy between MR imaging and diagnostic arthroscopic findings. MATERIALS AND METHODS:Five hundred sixty-one patients underwent arthroscopy and MR imaging of the knee. Prospective and retrospective reading...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.196.3.7644620

    authors: Justice WW,Quinn SF

    更新日期:1995-09-01 00:00:00

  • Imaging of the gallbladder, 1987.

    abstract::Gallbladder disease, and the patients with symptoms suggestive of gallbladder disease, remains a widespread clinical problem that requires investigation by imaging techniques. Sonography, and to a lesser extent cholescintigraphy, has facilitated the evaluation of these patients and allows the diagnosis of cholelithias...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.163.3.3554340

    authors: Cooperberg PL,Gibney RG

    更新日期:1987-06-01 00:00:00

  • Prostate cancer: contrast-enhanced us for detection.

    abstract:PURPOSE:To assess the detection of prostate cancer with contrast material-enhanced transrectal sonography. MATERIALS AND METHODS:Sixty subjects were examined with conventional gray-scale, harmonic gray-scale, and power Doppler sonography. Evaluation was repeated during intravenous infusion of contrast agent. Gray-scal...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.219.1.r01ap21219

    authors: Halpern EJ,Rosenberg M,Gomella LG

    更新日期:2001-04-01 00:00:00

  • Composite graft replacement of the ascending aorta: leakage detection with gadolinium-enhanced MR imaging.

    abstract:PURPOSE:To assess the value of magnetic resonance (MR) imaging in the detection of postoperative complications after composite valve graft replacement. MATERIALS AND METHODS:Spin-echo and gradient-echo MR imaging was performed in 52 patients 1/2 to 200 months after composite graft replacement of the ascending aorta (2...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.212.2.r99au02573

    authors: Fattori R,Descovich B,Bertaccini P,Celletti F,Caldarera I,Pierangeli A,Gavelli G

    更新日期:1999-08-01 00:00:00

  • Superior labral anterior posterior (SLAP) lesions of the glenoid labrum: reliability and accuracy of MR arthrography for diagnosis.

    abstract:PURPOSE:To determine the reliability and accuracy of magnetic resonance (MR) arthrography for the diagnosis of superior labral anterior posterior (SLAP) tears. MATERIALS AND METHODS:The MR arthrograms in 80 patients who underwent arthroscopy and MR arthrography during a 54-month period were retrospectively reviewed. M...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.218.1.r01ja44127

    authors: Jee WH,McCauley TR,Katz LD,Matheny JM,Ruwe PA,Daigneault JP

    更新日期:2001-01-01 00:00:00

  • Bronchiolitis obliterans syndrome: thin-section CT diagnosis of obstructive changes in infants and young children after lung transplantation.

    abstract:PURPOSE:To characterize the thin-section computed tomographic (CT) appearance of bronchiolitis fibrosa obliterans syndrome in infants and young children after lung transplantation. MATERIALS AND METHODS:Thin-section CT studies in six patients with bronchiolitis obliterans syndrome (age range, 2 months to 5 1/2 years) ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.208.3.9722860

    authors: Lau DM,Siegel MJ,Hildebolt CF,Cohen AH

    更新日期:1998-09-01 00:00:00

  • Cranial bone marrow in children: assessment of normal development with MR imaging.

    abstract::Magnetic resonance images of cranial bone marrow in 238 patients (246 examinations) less than 25 years old were reviewed to establish normal age-related standards. Bone marrow in the clivus and calvaria had uniformly low signal intensity (grade 1) on T1-weighted images in most infants less than 1 year old. The number ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.171.1.2928520

    authors: Okada Y,Aoki S,Barkovich AJ,Nishimura K,Norman D,Kjos BO,Brasch RC

    更新日期:1989-04-01 00:00:00

  • Atypical ductal hyperplasia diagnosed at stereotactic breast biopsy: improved reliability with 14-gauge, directional, vacuum-assisted biopsy.

    abstract:PURPOSE:To compare histologic findings of atypical ductal hyperplasia (ADH) at 14-gauge, directional, vacuum-assisted breast biopsy (hereafter, vacuum-assisted biopsy) and at 14-gauge, automated, large-core breast biopsy (hereafter, large-core biopsy) with findings at histologic examination after surgical biopsy. MATE...

    journal_title:Radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1148/radiology.204.2.9240540

    authors: Jackman RJ,Burbank F,Parker SH,Evans WP 3rd,Lechner MC,Richardson TR,Tocino I,Wray AB

    更新日期:1997-08-01 00:00:00

  • Electrotransfer at MR imaging: tool for optimization of gene transfer protocols--feasibility study in mice.

    abstract:PURPOSE:To test, by using an electrotransfer protocol for the transfection of skeletal muscle with naked plasmid complementary DNA, whether in vivo magnetic resonance (MR) imaging can help delineate either the spatial extent of the electric field when contrast agent is injected intraperitoneally or the transfection are...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2283020482

    authors: Paturneau-Jouas M,Parzy E,Vidal G,Carlier PG,Wary C,Vilquin JT,de Kerviler E,Schwartz K,Leroy-Willig A

    更新日期:2003-09-01 00:00:00

  • Quantitative Shear-Wave US Elastography of the Supraspinatus Muscle: Reliability of the Method and Relation to Tendon Integrity and Muscle Quality.

    abstract:PURPOSE:To evaluate the reliability of ultrasonographic (US) elastography of the supraspinatus (SSP) muscle, define normal shear-wave velocity (SWV) values, and correlate findings with tendon integrity and muscle quality. MATERIALS AND METHODS:The study was approved by the local ethics committee, and written informed ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2015150908

    authors: Rosskopf AB,Ehrmann C,Buck FM,Gerber C,Flück M,Pfirrmann CW

    更新日期:2016-02-01 00:00:00

  • Suspected local recurrence after radical prostatectomy: endorectal coil MR imaging.

    abstract:PURPOSE:To evaluate endorectal coil magnetic resonance (MR) imaging in the depiction of local recurrence after radical prostatectomy. MATERIALS AND METHODS:Endorectal MR images were reviewed retrospectively in 82 patients who underwent prostatectomy. The interval between prostatectomy and MR imaging ranged between 0.5...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2312030011

    authors: Sella T,Schwartz LH,Swindle PW,Onyebuchi CN,Scardino PT,Scher HI,Hricak H

    更新日期:2004-05-01 00:00:00

  • Incarcerated obturator hernia: case diagnosed at barium enema fluoroscopy.

    abstract::Incarcerated obturator hernia is an uncommon entity that on occasion may produce specific radiographic findings and clinical signs (Howship-Romberg sign) that permit diagnosis prior to celiotomy. A case is reported in which the diagnosis was suggested when pain in the thigh was elicited during the course of a barium e...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.172.1.2740520

    authors: Glicklich M,Eliasoph J

    更新日期:1989-07-01 00:00:00

  • The portacaval space: CT with MR correlation.

    abstract::Between the portal vein and the inferior vena cava lies a small space that may be occupied by multiple anatomic structures including the caudate and papillary processes of the caudate lobe of the liver, portacaval lymph nodes, replaced or accessory right hepatic arteries, posterosuperior pancreaticoduodenal vessels, t...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.156.2.4011910

    authors: Zirinsky K,Auh YH,Rubenstein WA,Kneeland JB,Whalen JP,Kazam E

    更新日期:1985-08-01 00:00:00

  • Diffusion-weighted MR imaging in the head and neck.

    abstract::Extracranial applications of diffusion-weighted (DW) magnetic resonance (MR) imaging are gaining increasing importance, including in head and neck radiology. The main indications for performing DW imaging in this relatively small but challenging region of the body are tissue characterization, nodal staging, therapy mo...

    journal_title:Radiology

    pub_type: 杂志文章,评审

    doi:10.1148/radiol.11101821

    authors: Thoeny HC,De Keyzer F,King AD

    更新日期:2012-04-01 00:00:00

  • Reduced cerebrovascular reserve at CO2 BOLD MR imaging is associated with increased risk of periinterventional ischemic lesions during carotid endarterectomy or stent placement: preliminary results.

    abstract:PURPOSE:To determine whether any initial reductions in cardiovascular reserve (CVR) normalize after carotid revascularization and-because reduced CVR represents a risk factor for ischemic events-whether patients who develop periinterventional infarction have more severely reduced pretreatment CVR than those who do not....

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2491071644

    authors: Haller S,Bonati LH,Rick J,Klarhöfer M,Speck O,Lyrer PA,Bilecen D,Engelter ST,Wetzel SG

    更新日期:2008-10-01 00:00:00

  • Characteristics of triangular fibrocartilage defects in symptomatic and contralateral asymptomatic wrists.

    abstract:PURPOSE:To characterize triangular fibrocartilage (TFC) defects in symptomatic and contralateral asymptomatic wrists. MATERIALS AND METHODS:Communicating and noncommunicating defects of the TFC were depicted on bilateral wrist arthrograms in 56 patients with unilateral wrist pain and without associated lesions of the ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.216.3.r00se06840

    authors: Zanetti M,Linkous MD,Gilula LA,Hodler J

    更新日期:2000-09-01 00:00:00

  • Reading protocol for dynamic contrast-enhanced MR images of the breast: sensitivity and specificity analysis.

    abstract:PURPOSE:To prospectively determine sensitivity and specificity of breast magnetic resonance (MR) imaging in a screening and symptomatic population by using independent double reading, with histologic or cytologic results or a minimum 18-month follow-up as the standard. MATERIALS AND METHODS:Informed consent and ethica...

    journal_title:Radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1148/radiol.2363040735

    authors: Warren RM,Pointon L,Thompson D,Hoff R,Gilbert FJ,Padhani A,Easton D,Lakhani SR,Leach MO,UK Magnetic Resonance Imaging in Breast Screening (MARIBS) Study Group.

    更新日期:2005-09-01 00:00:00

  • Clinical Outcomes of Radiofrequency Ablation for Early Hypovascular HCC: A Multicenter Retrospective Study.

    abstract::Purpose To retrospectively evaluate the clinical outcomes of radiofrequency ablation (RFA) for early hypovascular hepatocellular carcinomas (HCCs) and to compare them with those of typical hypervascular HCCs. Materials and Methods This retrospective multicenter study received institutional review board approval, with ...

    journal_title:Radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1148/radiol.2017162452

    authors: Lee DH,Lee JM,Kang TW,Rhim H,Kim SY,Shin YM,Seo JW,Choi MH,Lee KB

    更新日期:2018-01-01 00:00:00

  • Real-time computer verification for radiation therapy treatment machines.

    abstract::A computer based verification system which monitors the operation of a 4-MV linear accelerator is described. Fourteen parameters can be checked for proper alignment prior to irradiation. A training simulator was also built to minimize interference with treatment schedules and to provide technicians with experience in ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/131.1.258

    authors: Sternick ES,Berry JR,Curran B,Loomis SA

    更新日期:1979-04-01 00:00:00

  • Characteristics of a first-generation x-ray system.

    abstract:PURPOSE:To compare the antiquated x-ray system of Hoffmans and van Kleef (circa 1896) with modern x-ray equipment in terms of radiation dose, x-ray beam properties, image quality, and electrical parameters. MATERIALS AND METHODS:The antiquated x-ray system consisted of a Ruhmkorff inductor, battery, and Crookes tube. ...

    journal_title:Radiology

    pub_type: 历史文章,杂志文章

    doi:10.1148/radiol.11101899

    authors: Kemerink M,Dierichs TJ,Dierichs J,Huynen HJ,Wildberger JE,van Engelshoven JM,Kemerink GJ

    更新日期:2011-05-01 00:00:00

  • Dual mechanisms for change in myocardial signal intensity by means of a single MR contrast medium: dependence on concentration and pulse sequence.

    abstract::To determine whether gadodiamide injection can provide sufficient enhancement on both T1- and T2-weighted spin-echo magnetic resonance (MR) images of the heart and skeletal muscles, anesthetized rats were divided into five groups. Groups 1-3 received 0.1 (n = 9), 0.3 (n = 8), or 0.5 (n = 8) mmol/kg gadodiamide injecti...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.186.1.8416560

    authors: Saeed M,Wendland MF,Masui T,Yu KK,Li JJ,Derugin N,Higgins CB

    更新日期:1993-01-01 00:00:00

  • Craniosynostosis: diagnostic value of three-dimensional CT reconstruction.

    abstract::Three-dimensional computed tomography (CT) has an important role in determining the presence and extent of congenital and acquired craniofacial deformities. The authors compared the sensitivity and specificity of three-dimensional CT in the detection and characterization of craniosynostosis with that of planar CT and ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.173.3.2813770

    authors: Vannier MW,Hildebolt CF,Marsh JL,Pilgram TK,McAlister WH,Shackelford GD,Offutt CJ,Knapp RH

    更新日期:1989-12-01 00:00:00

  • Stage T1 non-small cell lung cancer: preoperative mediastinal nodal staging with integrated FDG PET/CT--a prospective study.

    abstract:PURPOSE:To prospectively evaluate the sensitivity and specificity of integrated fluorine 18 fluorodeoxyglucose (FDG) positron emission tomography (PET) and computed tomography (CT) (PET/CT) for the preoperative diagnosis of mediastinal nodal metastasis in stage T1 non-small cell lung cancer (NSCLC), with surgical and h...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2412051173

    authors: Kim BT,Lee KS,Shim SS,Choi JY,Kwon OJ,Kim H,Shim YM,Kim J,Kim S

    更新日期:2006-11-01 00:00:00

  • Spiral CT of the pancreas.

    abstract::Computed tomography (CT) is the modality of choice for evaluation of pancreatic disease. In this prospective study, images obtained with spiral CT, which enables examination of a region of the body in a single breath-hold, were compared with those obtained by means of dynamic CT with automatic table incrementation in ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.183.3.1584940

    authors: Dupuy DE,Costello P,Ecker CP

    更新日期:1992-06-01 00:00:00

  • Percutaneous catheter balloons: failure to deflate.

    abstract::Three examples of permanently inflated transluminal catheter balloons are presented. Two of these occurred during attempted percutaneous transluminal angioplasty. Nonsurgical solutions, which were successful in each case, are described. Percutaneous puncture with a needle or a larger diameter coaxial catheter under fl...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.155.3.3159040

    authors: Schneider JR,Johnsrude IS,Lund G,Rysavy J,Anderson RW,Amplatz K

    更新日期:1985-06-01 00:00:00

  • Hepatic hemangiomas and malignant tumors: improved differentiation with heavily T2-weighted conventional spin-echo MR imaging.

    abstract:PURPOSE:To determine whether hemangiomas and malignant tumors can be better differentiated at 1.5-T magnetic resonance imaging with use of more heavily T2-weighted conventional spin-echo sequences. MATERIALS AND METHODS:Eighty-three patients with focal liver lesions (50 malignant tumors, 24 hemangiomas, nine cysts) la...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.193.1.8090920

    authors: McFarland EG,Mayo-Smith WW,Saini S,Hahn PF,Goldberg MA,Lee MJ

    更新日期:1994-10-01 00:00:00