Abstract:
PURPOSE:To perform meta-analysis of literature about the role of helical computed tomography (CT) and ventilation-perfusion (V-P) scanning in detection of acute pulmonary embolism (PE) by using summary receiver operating characteristic (ROC) curve analysis. MATERIALS AND METHODS:V-P scanning articles published from January 1985 to March 2003 and helical CT articles published from January 1990 to March 2003 in MEDLINE and EMBASE databases were included if (a) tests were performed for evaluation of acute PE, (b) conventional angiography was the reference standard, and (c) absolute numbers of true-positive, false-negative, true-negative, and false-positive results were available. Sensitivity analysis was conducted by excluding articles published before 1995. RESULTS:A total of 12 articles discussing helical CT and/or V-P scanning were included. With a random-effects model, pooled sensitivity for helical CT was 86.0% (95% confidence interval [CI]: 80.2%, 92.1%), and specificity was 93.7% (95% CI: 91.1%, 96.3%). V-P scanning yielded low sensitivity of 39.0% (95% CI: 37.3%, 40.8%) but high specificity of 97.1% (95% CI: 96.0%, 98.3%) with high probability threshold. V-P scanning yielded high sensitivity of 98.3% (95% CI: 97.2%, 99.5%) and low specificity of 4.8% (95% CI: 4.7%, 4.9%) with normal threshold. Regression coefficients for helical CT angiography were 0.588 (95% CI: -1.55, 2.74) and 4.14 (95% CI: -0.002, 8.28) versus V-P scanning with high and normal thresholds, respectively. Regression coefficients for helical CT angiography were 0.588 (95% CI: -1.55, 2.74) and 4.14 (95% CI: -0.002, 8.28) versus V-P scanning with high and normal thresholds, respectively. CONCLUSION:Helical CT has greater discriminatory power than V-P scanning with normal and/or near-normal threshold to exclude PE, while helical CT and V-P scanning with high probability threshold had similar discriminatory power in the diagnosis of PE.
journal_name
Radiologyjournal_title
Radiologyauthors
Hayashino Y,Goto M,Noguchi Y,Fukui Tdoi
10.1148/radiol.2343031009subject
Has Abstractpub_date
2005-03-01 00:00:00pages
740-8issue
3eissn
0033-8419issn
1527-1315pii
234/3/740journal_volume
234pub_type
杂志文章,meta分析相关文献
RADIOLOGY文献大全abstract::We have reviewed our experience with 118 biliary catheterization procedures in 109 patients from 1979 to 1984. Major complications (septic shock, hemorrhage, subphrenic abscess, and formation of an arteriovenous fistula) occurred in five patients (4.2%), three of whom died (2.5%). Minor complications occurred in 41 pa...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.158.1.3940380
更新日期:1986-01-01 00:00:00
abstract::A case of achalasia complicated by Mycobacterium fortuitum pulmonary infection and empyema is reported. This association has been documented in the medical literature. Possible mechanisms explaining this association are discussed. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.160.1.3715050
更新日期:1986-07-01 00:00:00
abstract::Three examples of permanently inflated transluminal catheter balloons are presented. Two of these occurred during attempted percutaneous transluminal angioplasty. Nonsurgical solutions, which were successful in each case, are described. Percutaneous puncture with a needle or a larger diameter coaxial catheter under fl...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.155.3.3159040
更新日期:1985-06-01 00:00:00
abstract::Purpose To compare the capability of pulmonary thin-section magnetic resonance (MR) imaging with ultrashort echo time (UTE) with that of standard- and reduced-dose thin-section computed tomography (CT) in nodule detection and evaluation of nodule type. Materials and Methods The institutional review board approved this...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2017161037
更新日期:2017-08-01 00:00:00
abstract::Technetium-99m gamma camera images of kidneys produced with an iodine-131 energy window showed "ghosts" over and between the kidneys and between the kidneys and the bladder. The cause was coincidence summing at 281 keV due to a high 99mTc counting rate. In older model cameras careful peaking with a proper energy windo...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.146.2.6849100
更新日期:1983-02-01 00:00:00
abstract::The biodistribution of radiomanganese (54Mn) was studied in mice, rats, and dogs. Disappearance of radioactivity from the blood was extremely rapid, with a half-time of approximately 0.8 minutes. This resulted in very favorable myocardium-to-blood ratios, even at early times after administration. The myocardial uptake...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/133.3.769
更新日期:1979-12-01 00:00:00
abstract:PURPOSE:To investigate the relationship of spinal osteophytes to vertebral bone mineral density (BMD) and to spinal fracture. MATERIALS AND METHODS:This relationship was investigated in 203 men. Integral BMD was measured with dual x-ray absorptiometry, and both cortical and trabecular BMD were measured with quantitati...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.189.2.8210380
更新日期:1993-11-01 00:00:00
abstract:PURPOSE:To investigate technical feasibility, test-retest reproducibility, and the ability to differentiate healthy subjects from subjects with osteoarthritis (OA) with diffusion-tensor (DT) imaging parameters and T2 relaxation time. MATERIALS AND METHODS:This study was approved by the institutional review board and w...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.11110821
更新日期:2012-02-01 00:00:00
abstract:PURPOSE:To determine if oxidative and nitrative stress and/or apoptosis contribute to increased coagulation when combining radiofrequency (RF) ablation with liposomal doxorubicin. MATERIALS AND METHODS:Animal care committee approval was obtained. R3230 mammary adenocarcinomas in Fischer rats were treated with either R...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.09091196
更新日期:2010-04-01 00:00:00
abstract::Bilateral peripheral pulmonary infiltrates caused by Pneumocystis carinii developed in a patient undergoing mediastinal irradiation after chemotherapy for Hodgkin disease. The paramediastinal part of the lung included within the treatment port remained clear during the 2 1/2 weeks of radiation therapy. The distributio...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.163.3.3495020
更新日期:1987-06-01 00:00:00
abstract::The accuracy of nonenhanced spin-echo (SE) T2-weighted and contrast material-enhanced SE T1-weighted magnetic resonance (MR) imaging in assessing the degree of local tumor invasion was determined prospectively in 53 consecutive patients with clinically established early-stage carcinoma of the cervix. With a 0.5-T supe...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.188.3.8351350
更新日期:1993-09-01 00:00:00
abstract:PURPOSE:To investigate the effect of injection rate of contrast medium on aortic and hepatic peak enhancement at computed tomography. MATERIALS AND METHODS:Early pharmacokinetics of contrast enhancement was analyzed theoretically and simulated with a compartment model. Contrast enhancement curves were generated from t...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.206.2.9457200
更新日期:1998-02-01 00:00:00
abstract:PURPOSE:To compare the accuracies of whole-body 2-[fluorine 18]fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) and conventional imaging (thoracic computed tomography [CT], bone scintigraphy, and brain CT or magnetic resonance [MR] imaging) in staging bronchogenic carcinoma. MATERIALS AND METHODS:With...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.212.3.r99se21803
更新日期:1999-09-01 00:00:00
abstract:PURPOSE:To compare the usefulness of computed tomography (CT) and gadolinium-enhanced magnetic resonance (MR) imaging in the detection of neoplastic invasion of laryngeal cartilage. MATERIALS AND METHODS:In a prospective study, 53 patients with carcinoma of the larynx or piriform sinus underwent CT and MR imaging befo...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.194.3.7862960
更新日期:1995-03-01 00:00:00
abstract:PURPOSE:To compare specific findings at T1-weighted gradient-echo (GRE) magnetic resonance (MR) imaging performed after administration of superparamagnetic iron oxide (SPIO) with nontumorous regional portal perfusion abnormalities seen at computed tomography (CT) during arterial portography (CTAP). MATERIALS AND METHO...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.207.1.9530300
更新日期:1998-04-01 00:00:00
abstract::An aortobronchial fistula is a rare condition that is invariably fatal if not diagnosed and surgically treated. Aortic aneurysms, both atherosclerotic and infective, were the main causes in the originally described cases. However, thoracic cardiovascular surgery has recently become the predominant cause. The authors d...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.175.2.2326460
更新日期:1990-05-01 00:00:00
abstract::A review was made of 219 transcatheter vessel occlusion procedures performed over a ten-year period for control of hemorrhage, tumor palliation, or blood supply redistribution prior to intra-arterial chemotherapy. Complete angiographic success was obtained in 85% of the procedures, with partial success in 8%; complete...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.147.1.6828710
更新日期:1983-04-01 00:00:00
abstract::Sports medicine is one of the most rapidly growing subspecialties in orthopedics. Magnetic resonance (MR) imaging in sports medicine includes depiction of normal anatomy and pathologic conditions in almost every joint in the body, but the MR examinations most frequently requested are of the knee and shoulder. The repo...
journal_title:Radiology
pub_type: 杂志文章,评审
doi:10.1148/radiol.2243012180
更新日期:2002-09-01 00:00:00
abstract::Radiographs of 45 patients with evidence of acute unilateral ureteral obstruction at intravenous urography, obtained at least 24 hours after injection of contrast material, were retrospectively studied. Vicarious contrast material excretion (VCME) as evidence by gallbladder opacification on delayed radiographs was see...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.177.3.2243980
更新日期:1990-12-01 00:00:00
abstract::Purpose To examine whether cardiac chemical exchange saturation transfer (CEST) imaging can be serially and noninvasively used to probe cell survival or rejection after intramyocardial implantation in mice. Materials and Methods Experiments were compliant with the National Institutes of Health Guidelines on the Use of...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2016152766
更新日期:2017-01-01 00:00:00
abstract::The imaging performance of new high-strip-density (HSD) grids having 57 lines/cm was compared with that of conventional low-strip-density (LSD) grids having 33 or 40 lines/cm. The unique advantage of HSD grids is that, under most standard radiographic conditions, the grid lines are not noticeable on the final image, e...
journal_title:Radiology
pub_type: 临床试验,杂志文章
doi:10.1148/radiology.147.2.6340160
更新日期:1983-05-01 00:00:00
abstract::In a patient with choledocholithiasis, a duodenal diverticulum precluded endoscopic retrograde bile duct cannulation. A transhepatic catheter was used to opacify the bile ducts and to guide the endoscopic sphincterotome into the major duodenal papilla. Because limited sphincterotomy did not allow extraction or spontan...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.165.2.3116600
更新日期:1987-11-01 00:00:00
abstract:PURPOSE:To determine if patients with multiple fluid collections need every collection aspirated and if cross-contamination is a risk if separate sterile procedures are not followed for each aspiration. MATERIALS AND METHODS:Records from 1,076 imaging-guided percutaneous aspirations and drainages over 39 months were r...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.212.3.r99se25669
更新日期:1999-09-01 00:00:00
abstract::High-frequency (10-MHz) sonography demonstrated a cervical mass or lymphadenopathy, or both, during postoperative follow-up of 52 patients who had undergone surgery for thyroid cancer. Percutaneous biopsy with ultrasonographic (US) guidance was performed in all 52 masses, 44 of which were nonpalpable. Malignant cells ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.168.3.3043550
更新日期:1988-09-01 00:00:00
abstract::This study evaluated the feasibility of treatment of abdominal aortic aneurysm (AAA) by means of intraluminal bypass. Artificial aortic aneurysms with fusiform Dacron conduits were created at surgery , a weft-knit Dacron tube with balloon-expandable stents attached at both ends was inserted transfemorally through a 14...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.184.1.1535160
更新日期:1992-07-01 00:00:00
abstract:PURPOSE:To study the frequency, timing, and associations of thoracic metastases in advanced (stage III and IV) high-grade serous ovarian cancer (HGSC) to help optimize the use of cross-sectional chest imaging. MATERIALS AND METHODS:This institutional review board-approved retrospective study with waived informed conse...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2015142467
更新日期:2015-12-01 00:00:00
abstract::Left atrial-coronary sinus fenestration is a rare cause of a left-to-right or right-to-left shunt which occurs most commonly with a persistent left superior vena cava. These fenestrations may represent the only pathway for an obligatory right-to-left or left-to-right shunt in atrioventricular valve atresia. Four cases...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.135.2.7367620
更新日期:1980-05-01 00:00:00
abstract:PURPOSE:To quantify dynamic enhancement of breast lesions with echo-planar and conventional magnetic resonance (MR) imaging, to correlate these data with histologic findings and vessel density, and to evaluate MATERIALS AND METHODS:Twenty female patients with 22 breast lesions underwent conventional and MR echo-planar...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.197.1.7568850
更新日期:1995-10-01 00:00:00
abstract::Fifty temporomandibular joints (TMJs) in 30 asymptomatic volunteers were imaged with a 1.5-T magnetic resonance (MR) imaging system to determine (a) the normal range of meniscus position, (b) the best definition of a normal TMJ and criteria to distinguish it from a TMJ with significant internal derangements, (c) the s...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.177.1.2399340
更新日期:1990-10-01 00:00:00
abstract::Times of maximal involvement in mouse skin were determined for reactions produced by graded doses of x irradiation combined with hyperthermic treatment at 37.5, 41, 42, 42.5 and 43 degrees C for one hour. The times of maximal involvement in each case were found to be independent of thermal treatment. These data provid...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/119.2.475
更新日期:1976-05-01 00:00:00