The unique determination of the primary current by MEG and EEG.

Abstract:

:In this paper, we use a more realistic head model with ovoid geometry for approximation of a human head. By inverting the Geselowitz equation, some analytic results on the inverse MEG problem are presented in homogenous ovoid geometry. On one hand, some information about the components of primary current is shown by the decomposition of primary current in different coordinates in the case of a special MEG sensor position. On the other hand, in the general case, using decomposition of the primary current in spherical coordinates, we show that two scalar functions which specify the tangential part of the primary current can be uniquely determined with the assumption that two scalar functions are conjugate and harmonic in terms of two variables. Hence, the tangential part of the current can be completely known from the two scalar functions. Moreover, we obtain the unique determination of the primary current by combining MEG with EEG.

journal_name

Phys Med Biol

authors

Peng L,Cheng J,Jin L

doi

10.1088/0031-9155/51/21/012

subject

Has Abstract

pub_date

2006-11-07 00:00:00

pages

5565-80

issue

21

eissn

0031-9155

issn

1361-6560

pii

S0031-9155(06)29702-1

journal_volume

51

pub_type

杂志文章
  • Wavelet-packet-based texture analysis for differentiation between benign and malignant liver tumours in ultrasound images.

    abstract::The purpose of this study was to apply a novel method of multiscale echo texture analysis for distinguishing benign (hemangiomas) from malignant (hepatocellular carcinomas (HCCs) and metastases) focal liver lesions in B-mode ultrasound images. In this method, regions of interest (ROIs) extracted from within the lesion...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/22/008

    authors: Yoshida H,Casalino DD,Keserci B,Coskun A,Ozturk O,Savranlar A

    更新日期:2003-11-21 00:00:00

  • Algorithm and performance of a clinical IMRT beam-angle optimization system.

    abstract::This paper describes the algorithm and examines the performance of an intensity-modulated radiation therapy (IMRT) beam-angle optimization (BAO) system. In this algorithm successive sets of beam angles are selected from a set of predefined directions using a fast simulated annealing (FSA) algorithm. An IMRT beam-profi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/19/007

    authors: Djajaputra D,Wu Q,Wu Y,Mohan R

    更新日期:2003-10-07 00:00:00

  • Relative Patlak plot for dynamic PET parametric imaging without the need for early-time input function.

    abstract::The Patlak graphical method is widely used in parametric imaging for modeling irreversible radiotracer kinetics in dynamic PET. The net influx rate of radiotracer can be determined from the slope of the Patlak plot. The implementation of the standard Patlak method requires the knowledge of full-time input function fro...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aad444

    authors: Zuo Y,Qi J,Wang G

    更新日期:2018-08-10 00:00:00

  • Evaluation of radiochromic gel dosimetry and polymer gel dosimetry in a clinical dose verification.

    abstract::A quantitative comparison of two full three-dimensional (3D) gel dosimetry techniques was assessed in a clinical setting: radiochromic gel dosimetry with an in-house developed optical laser CT scanner and polymer gel dosimetry with magnetic resonance imaging (MRI). To benchmark both gel dosimeters, they were exposed t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/18/6241

    authors: Vandecasteele J,De Deene Y

    更新日期:2013-09-21 00:00:00

  • Impact of free-breathing CT on quantitative measurements of static and quiescent period-gated PET Images.

    abstract::Measurements of standardized uptake values (SUV) can vary due to many causes, including respiratory motion. Various methodologies have been introduced to correct for motion in PET, with quiescent-period-gated (QPG) PET being the most popular approach. QPG has been shown to improve PET image quantification compared to ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab1cdd

    authors: Meier JG,Einstein SA,Diab RH,Erasmus LJ,Xu G,Mawlawi OR

    更新日期:2019-05-16 00:00:00

  • Implementation and analysis of relief patterns of the surface of benign and malignant lesions of the skin by microtopography.

    abstract::The objective of this study was to be able to distinguish between healthy skin tissue and malignant ones, furthermore determining a unique pattern of roughness for each skin lesion by microtopographic analysis of the skin surface of Mexican patients during the period from April to October 2002. The standard technique ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/23/008

    authors: del Carmen López Pacheco M,da Cunha Martins-Costa MF,Zapata AJ,Cherit JD,Gallegos ER

    更新日期:2005-12-07 00:00:00

  • Monte Carlo simulation and dosimetric verification of radiotherapy beam modifiers.

    abstract::Monte Carlo simulation of beam modifiers such as physical wedges and compensating filters has been performed with a rectilinear voxel geometry module. A modified version of the EGS4/DOSXYZ code has been developed for this purpose. The new implementations have been validated against the BEAM Monte Carlo code using its ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/11/316

    authors: Spezi E,Lewis DG,Smith CW

    更新日期:2001-11-01 00:00:00

  • Evaluation of high performance data acquisition boards for simultaneous sampling of fast signals from PET detectors.

    abstract::Detectors used for positron emission tomography (PET) provide fast, randomly distributed signals that need to be digitized for further processing. One possibility is to sample the signals at the peak initiated by a trigger from a constant fraction discriminator (CFD). For PET detectors, simultaneous acquisition of man...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/1/003

    authors: Judenhofer MS,Pichler BJ,Cherry SR

    更新日期:2005-01-07 00:00:00

  • High intensity focused ultrasound for the treatment of rat tumours.

    abstract::Discrete implanted liver tumours in the rat have been exposed to arrays of 1.7 MHz ultrasound lesions. Focal peak intensities in the range 1.4-3.5 k Wcm-2 were used for an exposure time of 10 s. It has been demonstrated that where the whole tumour volume was exposed to the focused ultrasound beam, no evidence of tumou...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/36/11/009

    authors: ter Haar G,Rivens I,Chen L,Riddler S

    更新日期:1991-11-01 00:00:00

  • The Monte Carlo calculation of integral radiation dose in xeromammography.

    abstract::A Monte Carlo computer program has been developed for the computation of integral radiation dose to the breast in xeromammography. The results are given in terms of the integral dose per unit area of the breast per unit incident exposure. The calculations have been made for monoenergetic incident photons and the resul...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/25/1/003

    authors: Dance DR

    更新日期:1980-01-01 00:00:00

  • The modelling of biological systems in three dimensions using the time domain finite-difference method: I. The implementation of the model.

    abstract::A computer method has been developed which uses the time domain finite-difference (TDFD) algorithm to calculate the deposition of the electromagnetic (EM) field in three-dimensional biological models. This, the first of two papers, describes the algorithm and the computer programs developed. The method is demonstrated...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/11/006

    authors: Lau RW,Sheppard RJ

    更新日期:1986-11-01 00:00:00

  • A rapid colour stabilization technique for radiochromic film dosimetry.

    abstract::Various forms of GAFChromic film have been used for several years as radiographic media for measuring dose distributions of brachytherapy sources and small radiation fields. Upon irradiation the film changes colour and darkens with time post-irradiation. The darkening is most rapid in the first 24 h, and it has been s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/10/001

    authors: Reinstein LE,Gluckman GR,Meek AG

    更新日期:1998-10-01 00:00:00

  • Learning image based surrogate relevance criterion for atlas selection in segmentation.

    abstract::Picking geometrically relevant atlases from the whole training set is crucial to multi-atlas based image segmentation, especially with extensive data of heterogeneous quality in the Big Data era. Unfortunately, there is very limited understanding of how currently used image similarity criteria reveal geometric relevan...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/11/4223

    authors: Zhao T,Ruan D

    更新日期:2016-06-07 00:00:00

  • New compensator design options for charged-particle radiotherapy.

    abstract::The purpose of this investigation is to propose new compensator design strategies for protons and heavier particles which are based on pencil-beam (PB) dose calculations and which significantly reduce the dose to tissues downstream from the target, yet provide acceptable target coverage under conditions of patient mot...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/7/005

    authors: Petti PL

    更新日期:1997-07-01 00:00:00

  • Visually interpretable deep network for diagnosis of breast masses on mammograms.

    abstract::Recently, deep learning technology has achieved various successes in medical image analysis studies including computer-aided diagnosis (CADx). However, current CADx approaches based on deep learning have a limitation in interpreting diagnostic decisions. The limited interpretability is a major challenge for practical ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaef0a

    authors: Kim ST,Lee JH,Lee H,Ro YM

    更新日期:2018-12-04 00:00:00

  • Effects of bone- and air-tissue inhomogeneities on the dose distributions of the Leksell Gamma Knife calculated with PENELOPE.

    abstract::Monte Carlo simulation with PENELOPE (version 2003) is applied to calculate Leksell Gamma Knife dose distributions for heterogeneous phantoms. The usual spherical water phantom is modified with a spherical bone shell simulating the skull and an air-filled cube simulating the frontal or maxillary sinuses. Different sim...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/23/018

    authors: Al-Dweri FM,Rojas EL,Lallena AM

    更新日期:2005-12-07 00:00:00

  • Accuracy of Monte Carlo photon transport simulation in characterizing brachytherapy dosimeter energy-response artefacts.

    abstract::Practical dosimeters in brachytherapy, such as thermoluminescent dosimeters (TLD) and diodes, are usually calibrated against low-energy megavoltage beams. To measure absolute dose rate near a brachytherapy source, it is necessary to establish the energy response of the detector relative to that of the calibration ener...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/6/004

    authors: Das RK,Li Z,Perera H,Williamson JF

    更新日期:1996-06-01 00:00:00

  • Refraction-angle resolution of diffraction enhanced imaging.

    abstract::As a new method, x-ray diffraction enhanced imaging (DEI) has extremely high sensitivity for weakly absorbing low-Z samples in medical and biological fields. Conventional performance parameters, such as spatial resolution and low-contrast resolution, are not enough to describe the characteristics of a DEI system. This...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/12/002

    authors: Huang ZF,Kang KJ,Li Z

    更新日期:2006-06-21 00:00:00

  • Investigating the effect of longitudinal micro-CT imaging on tumour growth in mice.

    abstract::The aim of this study is to determine the impact of longitudinal micro-CT imaging on the growth of B16F1 tumours in C57BL/6 mice. Sixty mice received 2 × 10(5) B16F1 cells subcutaneously in the hind flank and were divided into control (no scan), 'low-dose' (80 kVp, 70 mA, 8 s, 0.07 Gy), 'medium-dose' (80 kVp, 50 mA, 3...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/2/002

    authors: Foster WK,Ford NL

    更新日期:2011-01-21 00:00:00

  • Thermoluminescent response and relative efficiency of TLD-100 exposed to low-energy x-rays.

    abstract::The dose-response of LiF:Mg,Ti (TLD-100) exposed to 15 and 35 kVp (8.0 +/- 0.1 and 8.1 +/- 0.1 keV effective energy respectively) x-rays and 60Co gamma-rays has been measured in the dose interval from (1.2-5.4) x 10(3) Gy for x-rays, and from 0.14 to 850 Gy for gamma-rays. In both cases the total TL signal and glow cu...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/8/006

    authors: Gamboa-deBuen I,Buenfil AE,Ruiz CG,Rodríguez-Villafuerte M,Flores A,Brandan ME

    更新日期:1998-08-01 00:00:00

  • A novel approach with dual-sampling convolutional neural network for ultrasound image classification of breast tumors.

    abstract::Breast cancer is one of the leading causes of female cancer deaths. Early diagnosis with prophylactic may improve the patients' prognosis. So far ultrasound (US) imaging is a popular method in breast cancer diagnosis. However, its accuracy is bounded to traditional handcrafted feature methods and expertise. A novel me...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abc5c7

    authors: Xie J,Song X,Zhang W,Dong Q,Wang Y,Li F,Wan C

    更新日期:2020-10-29 00:00:00

  • The inverse problem of a Gaussian convolution and its application to the finite size of the measurement chambers/detectors in photon and proton dosimetry.

    abstract::A Gaussian convolution kernel K is deduced as a Green's function of a Lie operator series. The deconvolution of a Gaussian kernel is developed by the inverse Green's function K(-1). A practical application is the deconvolution of measured profiles Dm(x) of photons and protons with finite detector size to determine the...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/6/302

    authors: Ulmer W,Kaissl W

    更新日期:2003-03-21 00:00:00

  • Quantitative validation of the 3D SAR profile of hyperthermia applicators using the gamma method.

    abstract::For quality assurance of hyperthermia treatment planning systems, quantitative validation of the electromagnetic model of an applicator is essential. The objective of this study was to validate a finite-difference time-domain (FDTD) model implementation of the Lucite cone applicator (LCA) for superficial hyperthermia....

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/11/010

    authors: de Bruijne M,Samaras T,Chavannes N,van Rhoon GC

    更新日期:2007-06-07 00:00:00

  • Dose evaluation of boron neutron capture synovectomy using the THOR epithermal neutron beam: a feasibility study.

    abstract::Rheumatoid arthritis is one of the most common epidemic diseases in the world. For some patients, the treatment with steroids or nonsteroidal anti-inflammatory drugs is not effective, thus necessitating physical removal of the inflamed synovium. Alternative approaches other than surgery will provide appropriate diseas...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/6/014

    authors: Wu J,Chang SJ,Chuang KS,Hsueh YW,Yeh KC,Wang JN,Tsai WP

    更新日期:2007-03-21 00:00:00

  • Beam configurations for 3D tomographic intensity modulated radiation therapy.

    abstract::We extend the theory of three-dimensional (3D) tomographic intensity modulated radiation therapy (IMRT). The geometry consists of two-dimensional modulated beams on a sphere centred in the tumour. The theory provides an efficient algorithm for computing beam modulation patterns that approximately 'reconstruct' the pre...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/5/306

    authors: Levine RY,Braunstein M

    更新日期:2002-03-07 00:00:00

  • First in-beam PET measurement of beta+ radioactivity induced by hard photon beams.

    abstract::In this note, we present the first experimental results of in-beam PET measurements during high energy photon phantom irradiation. An inhomogeneous phantom was irradiated with pulsed 34 MV bremsstrahlung. The measurements have been conducted with a dedicated double head positron camera. A high material contrast could ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/20/N01

    authors: Kluge T,Möckel D,Pawelke J,Enghardt W

    更新日期:2007-10-21 00:00:00

  • Accurate helical cone-beam CT reconstruction with redundant data.

    abstract::We present a new image reconstruction algorithm for helical cone-beam computed tomography (CT). This algorithm is designed for data collected at or near maximum pitch, and provides a theoretically exact and stable reconstruction while beneficially using all measured data. The main operations involved are a differentia...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/15/001

    authors: Schöndube H,Stierstorfer K,Noo F

    更新日期:2009-08-07 00:00:00

  • Assessment of organ-specific neutron equivalent doses in proton therapy using computational whole-body age-dependent voxel phantoms.

    abstract::Proton beams used for radiotherapy will produce neutrons when interacting with matter. The purpose of this study was to quantify the equivalent dose to tissue due to secondary neutrons in pediatric and adult patients treated by proton therapy for brain lesions. Assessment of the equivalent dose to organs away from the...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/3/012

    authors: Zacharatou Jarlskog C,Lee C,Bolch WE,Xu XG,Paganetti H

    更新日期:2008-02-07 00:00:00

  • 2D convolution kernels of ionization chambers used for photon-beam dosimetry in magnetic fields: the advantage of small over large chamber dimensions.

    abstract::This study aims at developing an optimization strategy for photon-beam dosimetry in magnetic fields using ionization chambers. Similar to the familiar case in the absence of a magnetic field, detectors should be selected under the criterion that their measured 2D signal profiles M(x,y) approximate the absorbed dose to...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aab50c

    authors: Looe HK,Delfs B,Poppinga D,Harder D,Poppe B

    更新日期:2018-03-29 00:00:00

  • Monitoring daily MLC positional errors using trajectory log files and EPID measurements for IMRT and VMAT deliveries.

    abstract::This work investigated the differences between multileaf collimator (MLC) positioning accuracy determined using either log files or electronic portal imaging devices (EPID) and then assessed the possibility of reducing patient specific quality control (QC) via phantom-less methodologies. In-house software was develope...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/9/N49

    authors: Agnew A,Agnew CE,Grattan MW,Hounsell AR,McGarry CK

    更新日期:2014-05-07 00:00:00