Abstract:
:Histograms of the results of quantitative clinical laboratory analyses are usually broadly skewed because some of the patients have normal values with respect to the analyte being measured while values for others are below or above normal. We describe a technique for calculating the maximum possible number of individuals in a patient population who will give normal values and, by difference, the minimum possible number of those who will give below-normal and above-normal values. The technique permits estimation of the probability that any given result represents a member of a particular subpopulation, as well as selection of decision limits for patient classification, and estimates the degree of change required for a subject with a normal value to start giving below- or above-normal values.
journal_name
Clin Chemjournal_title
Clinical chemistryauthors
Grannis GF,Lott JAsubject
Has Abstractpub_date
1978-04-01 00:00:00pages
640-51issue
4eissn
0009-9147issn
1530-8561journal_volume
24pub_type
杂志文章abstract::We developed a highly sensitive, convenient assay for measuring blocking-type anti-acetylcholine receptor antibodies, which inhibit the binding of 125I-labeled alpha-bungarotoxin (alpha-BuTx) to the acetylcholine receptor (AChR). This procedure detected inhibitory activities in sera from 76% of patients with myastheni...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1993-10-01 00:00:00
abstract::The time-course of the contamination of exogenous hydrogen from cigarette smoke on postprandial breath hydrogen concentration was evaluated in 10 subjects, six regular smokers and four occasional smokers. Breath hydrogen values were determined by gas chromatography 10 min, 5 min, and immediately prior to smoking a fil...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1983-11-01 00:00:00
abstract::The values of apolipoproteins (apo) A-I and B were determined in a population sample of hospital outpatients with a standardized method to verify if the cutpoints calculated in a cross-sectional study in the US are usable with other populations. We also tested the apolipoproteins' ability to discriminate between healt...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1998-01-01 00:00:00
abstract::We measured the day-to-day variations in concentrations of beta-core, luteinizing hormone (LH), and alpha-subunit in urine during the menstrual cycle. The alpha-subunit concentrations showed a pattern similar to that of the LH concentrations. beta-Core-like material was increased during and up to 3 to 4 days after the...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1993-09-01 00:00:00
abstract:BACKGROUND:The analytical and clinical performance of homogeneous LDL-cholesterol assays has been reported, but their reactions with subfractions of LDL and VLDL have not been described in detail. METHODS:We evaluated reaction selectivity of two homogeneous LDL-cholesterol assays, LDLk (Kyowa Medex) and LDLd (Daiichi ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:2002-11-01 00:00:00
abstract::Hepatitis A virus (HAV) infection occurs worldwide and is an important cause of acute viral hepatitis in the US. In this review, I cover the epidemiology, course of infection, clinical manifestations, serological responses, and prevention of this infection. Although most patients completely recover from this disease, ...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:
更新日期:1997-08-01 00:00:00
abstract::We evaluated the performance of two homogeneous assays for quantifying HDL cholesterol (HDL-C) and compared them with the phosphotungstic acid (PTA)/ MgCl2 assay. Both homogeneous HDL-C assays were precise, having a within-run CV of < 1.20% and a between-run CV of < 4.07%. The HDL-C values (y) measured by the two homo...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1997-06-01 00:00:00
abstract:BACKGROUND:The current diagnosis and monitoring of bladder cancer are heavily reliant on cystoscopy, an invasive and costly procedure. Previous efforts in urine-based detection of bladder cancer focused on targeted approaches that are predicated on the tumor expressing specific aberrations. We aimed to noninvasively de...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2018.301341
更新日期:2019-07-01 00:00:00
abstract::This paper compares a logistic curve and a mass-action curve in their ability to represent radioimmunoassay standard curves. A data base from 10 different assays is used in this comparison. Six of the 10 assays could be modeled equally well by either the logistic or the mass-action curve. In one case the mass-action c...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1983-10-01 00:00:00
abstract:BACKGROUND:A substantial proportion of the variability in the absorption and clearance of cyclosporin A (CsA) after oral administration has been attributed to variability in liver cytochrome P-450 3A4 (CYP3A4) activity and intestinal P-glycoprotein (P-gp) concentration. A polymorphism in the CYP3A4 promoter region, ter...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:2001-06-01 00:00:00
abstract::We evaluated a dual-precipitation method for determining cholesterol in high-density lipoprotein (HDL) and its subfractions HDL2 and HDL3. After total HDL was isolated by precipitation of very-low-density (VLDL) and low-density (LDL) lipoproteins with polyethylene glycol (Mr 8000), HDL2 was isolated from total HDL by ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1988-11-01 00:00:00
abstract::A new type of multilayer film analytical element--consisting of a spreading layer, a blocking layer, an enzymic reagent layer, and a transparent layer--has been developed for blood glucose determination. After a spot of whole blood is dropped on the film, the plasma glucose concentration is determined in 6 min without...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1981-07-01 00:00:00
abstract::We present data on a filter-paper collection and assay method for measurement of glycated hemoglobin (gHb). Onto filter paper dipped into a solution of glucose oxidase (EC 1.1.3.4) and allowed to dry, approximately 20 microL of capillary blood was spotted. For analysis, we eluted the dried blood spot from the paper by...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1986-05-01 00:00:00
abstract::Phenobarbital and phenytoin are extracted and concentrated in a single step, without solvent evaporation, followed by on-column methylation and gas-chromatographic quanitation. A similar extraction step for the assay of theophylline by high-pressure liquid chromatography is described. The extraction step can be comple...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1978-09-01 00:00:00
abstract::Serial results from an individual are often obtained using more than one method. Results should be transferable over time and locale. Every method has inherent analytical error, and goals are required to delineate the maximum allowable random (imprecision) and systematic (inaccuracy, bias) errors to facilitate optimal...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:
更新日期:1992-11-01 00:00:00
abstract:BACKGROUND:Endothelin-1 (ET-1), a potent vasoconstrictor, is difficult to measure because of its instability and its binding to receptors and plasma proteins. We report a rapid, robust way to indirectly quantify ET-1 release by measuring the C-terminal ET-1 precursor fragment (CT-proET-1) without an extraction step. M...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2005.065581
更新日期:2006-06-01 00:00:00
abstract::We established the validity of a quantitative reverse transcription (RT)-PCR assay for the RNA component of human telomerase (hTR), using the TaqMan fluorogenic detection system. Using this assay, we quantified hTR expression in two human pancreatic cancer cell lines, ASPC-1 and MIAPaCa-2. Our results indicated that h...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1998-12-01 00:00:00
abstract::Autocorrelation of clinical chemistry quality-control (Q/C) measurements causes one of the basic assumptions underlying the use of Levey-Jennings control charts to be violated and performance to be degraded. This is the requirement that the observations be statistically independent. We present a proposal for a new app...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1988-07-01 00:00:00
abstract:BACKGROUND:Because reference values for vitamin B(12) concentrations and vitamin B(12)-binding capacities for pregnant women have not been established, the reference values for nonpregnant women are often applied to assess vitamin B(12) status. The aim of the present study was to describe ranges of biochemical indices ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:2002-06-01 00:00:00
abstract::We used enzyme immunoassay to measure apolipoprotein B concentration in human plasma. Pure lipoprotein B was isolated from serum samples of fasting normolipidemic subjects by sequential preparative ultracentrifugation and coated to a polystyrene tube surface by adsorption. Human serum samples and rabbit antiserum to h...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1978-03-01 00:00:00
abstract::Reference values were determined for 23 plasma free amino acids from measurements done in 148 healthy children ranging from 0 to 18 years of age. Amino acid analysis was performed by ion-exchange chromatography. We propose a graphic form of presenting the age-specific distribution of plasma amino acid concentrations w...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1997-12-01 00:00:00
abstract:BACKGROUND:Paraoxonase may mitigate oxidative damage and thus lower risk of macrovascular disease. METHODS:DNA samples from 2252 participants in the Coronary Artery Risk Development in Young Adults (CARDIA) study were genotyped for the L55M and Q192R polymorphisms of the PON1 (paraoxonase 1) gene, and paraoxonase acti...
journal_title:Clinical chemistry
pub_type: 杂志文章,多中心研究
doi:10.1373/clinchem.2007.099044
更新日期:2008-04-01 00:00:00
abstract::Using 123 specimens, we compared the concordance of three different methods for determining glycohemoglobin (GHb): the Diamat (Bio-Rad Laboratories), an automated analyzer measuring HbA1c by cation-exchange chromatography; an assay with the IMx analyzer (Abbott Laboratories), based on boronate affinity binding; and an...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1995-02-01 00:00:00
abstract::We describe a new multilayer immunoassay element for the determination of haptens in undiluted serum and plasma. Polysaccharide layers are coated onto a plastic base. The signal layer contains an immobilized antibody and a fluorescent-labeled hapten. A second layer, containing a pigment, acts as an optical screen. Sam...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1989-09-01 00:00:00
abstract::Recombinant DNA techniques are contributing to the understanding of the pathogeneses of genetic, neoplastic, and viral diseases, and are used in the diagnosis of certain genetic and viral diseases. Such techniques will have wider application in the future and will play an increasing role in the clinical laboratory. Th...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1985-06-01 00:00:00
abstract::In a previous comparison study of "dry chemistry" desktop analyzers, the ChemPro 1000 (Arden Medical Systems) was one of several instruments found suitable for field use. We have now evaluated the linearity, accuracy, and precision of the ChemPro 1000, according to NCCLS Document EP 10-P. We also compared results with...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1989-11-01 00:00:00
abstract::To clarify whether manganese nutritional status is better reflected by the manganese concentration in lymphocytes or in whole blood, we injected manganese solutions intravenously into manganese-deficient rats and determined manganese concentrations in lymphocytes, whole blood, and various tissues. The manganese concen...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1989-09-01 00:00:00
abstract:BACKGROUND:Multiplexed amplicon melting is a closed-tube method for genotyping that does not require probes, real-time analysis, asymmetric PCR, or allele-specific PCR; however, correct differentiation of homozygous mutant and wild-type samples by melting temperature (T(m)) analysis requires high-resolution melting ana...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2007.097121
更新日期:2008-01-01 00:00:00
abstract::Analytical, intra-individual, and interindividual components of variation have been determined for pH, pCO2, bicarbonate, base excess, and total CO2 in capillary specimens of whole blood from a cohort of 14 healthy subjects. Calculated analytical goals (SD) are pH less than or equal to 0.008, pCO2 less than or equal t...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1987-08-01 00:00:00
abstract::We measured the rate of elimination of phenylalanine by constant intravenous infusion of L-phenylalanine in 14 parents of children with phenylketonuria and in 21 subjects with a negative family history for this disease. When reciprocals of the observed elimination rates were plotted against the reciprocals of the incr...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1977-09-01 00:00:00