Abstract:
:The purpose of this study was to prospectively use a whole-heart three-dimensional (3D) coronary magnetic resonance (MR) angiography technique specifically adapted for use at 3 T and a parallel imaging technique (sensitivity encoding) to evaluate coronary arterial anomalies and variants (CAAV). This HIPAA-compliant study was approved by the local institutional review board, and informed consent was obtained from all participants. Twenty-two participants (11 men, 11 women; age range, 18-62 years) were included. Ten participants were healthy volunteers, whereas 12 participants were patients suspected of having CAAV. Coronary MR angiography was performed with a 3-T MR imager. A 3D free-breathing navigator-gated and vector electrocardiographically-gated segmented k-space gradient-echo sequence with adiabatic T2 preparation pulse and parallel imaging (sensitivity encoding) was used. Whole-heart acquisitions (repetition time msec/echo time msec, 4/1.35; 20 degrees flip angle; 1 x 1 x 2-mm acquired voxel size) lasted 10-12 minutes. Mean examination time was 41 minutes +/- 14 (standard deviation). Findings included aneurysms, ectasia, arteriovenous fistulas, and anomalous origins. The 3D whole-heart acquisitions developed for use with 3 T are feasible for use in the assessment of CAAV.
journal_name
Radiologyjournal_title
Radiologyauthors
Gharib AM,Ho VB,Rosing DR,Herzka DA,Stuber M,Arai AE,Pettigrew RIdoi
10.1148/radiol.2471070274subject
Has Abstractpub_date
2008-04-01 00:00:00pages
220-7issue
1eissn
0033-8419issn
1527-1315pii
247/1/220journal_volume
247pub_type
杂志文章相关文献
RADIOLOGY文献大全abstract:PURPOSE:To evaluate imaging utilization trends in patients with acute pancreatitis (AP) and to assess independent predictors of radiology usage in relation to patient outcomes. MATERIALS AND METHODS:Institutional review board approval was obtained for this HIPAA-compliant study; written informed consent was waived. AP...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.10100320
更新日期:2011-01-01 00:00:00
abstract:PURPOSE:To measure infrarenal abdominal aortic aneurysms and assess the implications and potential obstacles for placement of an endovascular aortic graft undergoing clinical testing in Europe. MATERIALS AND METHODS:Helical computed tomography was used to measure 77 infrarenal aortic aneurysms (77 patients) and the di...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.198.2.8596850
更新日期:1996-02-01 00:00:00
abstract:PURPOSE:To retrospectively determine the incidence of nephrogenic systemic fibrosis (NSF) in a large academic medical center after the adoption of restrictive gadolinium-based contrast agent (GBCA) administration guidelines. MATERIALS AND METHODS:For this retrospective HIPAA-compliant study, institutional review board...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.11102340
更新日期:2011-07-01 00:00:00
abstract::The authors report an inflammatory fibroid polyp of the colon which simulated a tumor on the air-contrast barium-enema examination. Histological evaluation revealed the inflammatory nature of the polyp. These rare lesions can be radiographically indistinguishable from primary colon carcinoma. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.149.1.6611950
更新日期:1983-10-01 00:00:00
abstract::Normal menisci may show transient distortion during knee arthrography. This usually results from intermittent visualization of the meniscus out of direct profile to the x-ray beam. Similar transient distortion may result from actual buckling of an anatomically normal meniscus during stressful maneuvers in young indivi...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/126.1.89
更新日期:1978-01-01 00:00:00
abstract::Three-compartment arthrography has been advocated in the current literature for evaluation of the intrinsic ligaments of the wrist. Previous techniques for distal radioulnar joint (DRUJ) injection introduce the needle directly into the joint space. As is done in shoulder arthrography, however, the needle tip can be po...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.199.1.8633160
更新日期:1996-04-01 00:00:00
abstract::The inflammatory effects of fallopian tube catheterization and selective injection of seven contrast agents (ethiodized oil, diatrizoate meglumine 52%, diatrizoate meglumine 66%, iothalamate meglumine 60%, iopamidol, ioxitol, and ioxaglate) were evaluated in 88 rabbits. The contrast agent used was randomly selected an...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.180.1.1647040
更新日期:1991-07-01 00:00:00
abstract::Over 1/3 of patients with renal cell carcinoma will present with metastases with no symptoms referable to the kidney. Early metastatic disease is a result of the unique accessibility of the kidney to lymphohematogenous pathways. The thorax is particularly vulnerable. Several of the more unusual manifestations involvin...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/121.1.43
更新日期:1976-10-01 00:00:00
abstract::The authors conducted a multivariate analysis of the prognostic factors in 96 patients with early glottic cancer treated by radiation therapy. Of these, 73 had T1 and 23 had T2 tumor. The primary tumor was controlled in 82% of T1 and 74% of T2 lesions. Actuarial five-year survival rates were 87% for T1 and 74% for T2....
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.149.1.6611940
更新日期:1983-10-01 00:00:00
abstract::A method to decrease the intensity of fat by reversal of the section-select gradient is demonstrated. This technique takes advantage of the chemical shift in section location. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.168.2.3393670
更新日期:1988-08-01 00:00:00
abstract:PURPOSE:To validate three previously identified quantitative image features across multiparametric magnetic resonance (MR) images acquired with imagers made by two different manufacturers to differentiate prostate cancer (PC) from normal prostatic tissue and to assess cancer aggressiveness. MATERIALS AND METHODS:This ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.14131320
更新日期:2014-05-01 00:00:00
abstract::Percutaneous tunable dye laser lithotripsy was used in two patients to successfully fragment a 2-cm left hepatic duct calculus and a 5-mm main pancreatic duct calculus. Tunable dye laser lithotripsy may prove to be a more effective alternative to mechanical lithotripsy. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.174.3.1968280
更新日期:1990-03-01 00:00:00
abstract::Background Relevance of antiangiogenic treatment with bevacizumab in patients with glioblastoma is controversial because progression-free survival benefit did not translate into an overall survival (OS) benefit in randomized phase III trials. Purpose To perform longitudinal characterization of intratumoral angiogenesi...
journal_title:Radiology
pub_type: 杂志文章,随机对照试验
doi:10.1148/radiol.2020200978
更新日期:2020-10-01 00:00:00
abstract::Purpose To evaluate the immediate and long-term safety as well as thrombus-capturing efficacy for 5 weeks after implantation of an absorbable inferior vena cava (IVC) filter in a swine model. Materials and Methods This study was approved by the institutional animal care and use committee. Eleven absorbable IVC filters...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2017161880
更新日期:2017-12-01 00:00:00
abstract::Purpose To determine whether the use of one or two needles influences procedure performance and patient outcomes for ultrasonography (US)-guided percutaneous irrigation of calcific tendinopathy. Materials and Methods Institutional review board approval and written informed patient consent were obtained. From February ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2017162888
更新日期:2017-11-01 00:00:00
abstract::Background Results of recent phantom studies show that variation in CT acquisition parameters and reconstruction techniques may make radiomic features largely nonreproduceable and of limited use for prognostic clinical studies. Purpose To investigate the effect of CT radiation dose and reconstruction settings on the r...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2019190928
更新日期:2019-12-01 00:00:00
abstract::The authors retrospectively assessed with sonography the prevalence of thyroid gland abnormalities in 30 patients who underwent radiation therapy for Hodgkin disease between 1962 and 1984. Doses ranged from 3,000 to 4,500 rad (3,000-4,500 cGy). Abnormalities were found in the sonograms of 24 patients and included unil...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.172.1.2662250
更新日期:1989-07-01 00:00:00
abstract::An angiographic system capable of simultaneous biplane stereoscopic magnification cerebral angiography was evaluated. Stereoscopic imaging improved the morphologic depiction of aneurysms and of arteriovenous malformations. In a series of 357 patients, procedure time was reduced because the initial biplane stereoscopic...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.165.2.3659390
更新日期:1987-11-01 00:00:00
abstract:PURPOSE:To test for an association between high-grade acute organ toxicity during adjuvant radiation and chemotherapy and treatment outcome in patients with locally advanced head and neck squamous cell carcinoma (HNSCC). MATERIALS AND METHODS:Institutional review board approval was obtained for this retrospective stud...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.10100705
更新日期:2011-03-01 00:00:00
abstract::Five hundred celiac angiograms were reviewed to evaluate the frequency of clinically significant variations in the origin of the left gastric artery. In 13 of 500 cases, the left gastric artery arose anomalously most often as a direct branch of the aorta; in 14 of 500 cases, the left gastric artery primarily supplied ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/126.3.623
更新日期:1978-03-01 00:00:00
abstract::To visualize the flow of cerebrospinal fluid (CSF) throughout the ventricles and subarachnoid space, measure mean and maximum CSF velocities, and quantitate CSF flow through the aqueduct of Sylvius, magnetic resonance (MR) imaging was performed with a sagittal technique that is flow-sensitive in the craniocaudal direc...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.183.2.1561340
更新日期:1992-05-01 00:00:00
abstract:PURPOSE:To derive normalized data for the estimation of effective, gonadal, and peak skin doses to patients undergoing vertebroplasty or kyphoplasty and to investigate the potential for cancer induction, genetic effects, and radiation-induced skin injury after such procedures. MATERIALS AND METHODS:Dose values normali...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2323031412
更新日期:2004-09-01 00:00:00
abstract::One hundred fifty-four patients with stenosis of the iliac artery underwent percutaneous transluminal angioplasty (PTA). These patients were followed for 1-7 years. The long-term results of the PTAs were analyzed by computer, and life tables were generated for dilatations of the iliac arteries with unimpaired flow and...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.156.2.3160060
更新日期:1985-08-01 00:00:00
abstract::Computed tomography can help in the evaluation of congenitally anomalous aortic arches and subclavian arteries. The authors discuss the role of computed tomography in the evaluation of such anomalies in seven patients. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.138.2.7455120
更新日期:1981-02-01 00:00:00
abstract::Phantom studies were performed to develop a technique for linear tomography of the craniocervical junction with a digital fluoroscopic angiographic C-arm unit. Section thicknesses were similar to those used at conventional tomography, and the radiation dose was lower. C-arm tomography was possible with a 6-second expo...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.211.3.r99jn02882
更新日期:1999-06-01 00:00:00
abstract::We report qualitative and quantitative evaluation and verification studies of the bipolar phase gradient modulation method for true MR imaging of internal flow and motion velocities. Velocity encoding modulations provide speed-of-motion and direction-sensitive images using special phase-sensitive reconstructions. True...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.154.2.3966130
更新日期:1985-02-01 00:00:00
abstract::Fine needle, percutaneous aspiration of suspect lymph nodes was carried out in 29 patients during fluoroscopy. The correct positioning of the needle was assured if the node moved with the tip of the needle. In 29 patients, there were 65 successful aspirations and 29 failures. Anesthesia is recommended but care should ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/120.1.205
更新日期:1976-07-01 00:00:00
abstract:PURPOSE:To compare histologic findings of atypical ductal hyperplasia (ADH) at 14-gauge, directional, vacuum-assisted breast biopsy (hereafter, vacuum-assisted biopsy) and at 14-gauge, automated, large-core breast biopsy (hereafter, large-core biopsy) with findings at histologic examination after surgical biopsy. MATE...
journal_title:Radiology
pub_type: 杂志文章,多中心研究
doi:10.1148/radiology.204.2.9240540
更新日期:1997-08-01 00:00:00
abstract::History A 55-year-old woman presented to our breast clinic with 1-year history of lancinating pain in the right breast that was exacerbated by blunt pressure and cold temperature. She denied any family history of breast cancer or any personal history of trauma, infection, or surgery of the breast. On clinical examinat...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.13120919
更新日期:2014-01-01 00:00:00
abstract::Purpose To determine the impact of nonvascular thoracic magnetic resonance (MR) imaging on the clinical decision making and diagnostic certainty of thoracic surgeons. Materials and Methods Seven thoracic surgeons at Massachusetts General Hospital, an academic quaternary referral hospital, participated in this 2-year, ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2016152004
更新日期:2016-08-01 00:00:00