Cervical spine tomography with an angiographic C-arm.

Abstract:

:Phantom studies were performed to develop a technique for linear tomography of the craniocervical junction with a digital fluoroscopic angiographic C-arm unit. Section thicknesses were similar to those used at conventional tomography, and the radiation dose was lower. C-arm tomography was possible with a 6-second exposure and a 40 degrees arc. C-arm tomography is a practical method for decreasing patient turnaround time.

journal_name

Radiology

journal_title

Radiology

authors

Ridpath CA,Wilson AJ,Langer SG,Mann FA,Hunter JC

doi

10.1148/radiology.211.3.r99jn02882

subject

Has Abstract

pub_date

1999-06-01 00:00:00

pages

882-5

issue

3

eissn

0033-8419

issn

1527-1315

journal_volume

211

pub_type

杂志文章
  • Breast cancer imaging with In-111 human IgM monoclonal antibodies: preliminary studies.

    abstract::Detection of specific tumor sites was studied with scintigraphy and radiolabeled human IgM monoclonal antibodies (MoAbs). Ten patients with metastatic breast cancer received an infusion of one of three indium-111-labeled anti-breast carcinoma MoAbs. The time of infusion ranged from 30 minutes to 2 hours. Three patient...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.167.1.3347750

    authors: Ryan KP,Dillman RO,DeNardo SJ,DeNardo GL,Beauregard J,Hagan PL,Amox DG,Clutter ML,Burnett KG,Rulot CM

    更新日期:1988-04-01 00:00:00

  • Combined FDG and [F-18]fluoride whole-body PET: a feasible two-in-one approach to cancer imaging?

    abstract:PURPOSE:To evaluate the diagnostic usefulness of the combined application of 2-[fluorine-18]fluoro-2-deoxy-D-glucose (FDG; for the evaluation of soft tissue) and [F-18]fluoride (for the evaluation of the skeleton) in positron emission tomography (PET) of cancer. MATERIALS AND METHODS:Sixty consecutive patients (23 wom...

    journal_title:Radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1148/radiology.209.1.9769840

    authors: Hoegerle S,Juengling F,Otte A,Altehoefer C,Moser EA,Nitzsche EU

    更新日期:1998-10-01 00:00:00

  • Case 241: Hemiparkinsonism- Hemiatrophy-SPECT with 99mTc TRODAT-1 and Muscle MR Imaging Abnormalities.

    abstract::History A 43-year-old right-handed man presented with a history of progressive mild left-sided weakness and slowness of movements. Symptoms began 4 years earlier, and the patient noticed a progressive decline in his daily routine due to gait difficulties in the past year. There was no history of head trauma, surgery, ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2017151717

    authors: Vale TC,de Lima Pinto FC,Pedroso JL,Alves Dos Reis M,Batista IR,Affonseca Bressan R,Magalhães Rivero RL,Mendonça RA,Barsottini OG

    更新日期:2017-05-01 00:00:00

  • Biofunctionalized Hybrid Magnetic Gold Nanoparticles as Catalysts for Photothermal Ablation of Colorectal Liver Metastases.

    abstract::Purpose To demonstrate that anti-MG1 conjugated hybrid magnetic gold nanoparticles (HNPs) act as a catalyst during photothermal ablation (PTA) of colorectal liver metastases, and thus increase ablation zones. Materials and Methods All experiments were performed with approval of the institutional animal care and use co...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2017161497

    authors: White SB,Kim DH,Guo Y,Li W,Yang Y,Chen J,Gogineni VR,Larson AC

    更新日期:2017-12-01 00:00:00

  • Clinical Outcomes of Radiofrequency Ablation for Early Hypovascular HCC: A Multicenter Retrospective Study.

    abstract::Purpose To retrospectively evaluate the clinical outcomes of radiofrequency ablation (RFA) for early hypovascular hepatocellular carcinomas (HCCs) and to compare them with those of typical hypervascular HCCs. Materials and Methods This retrospective multicenter study received institutional review board approval, with ...

    journal_title:Radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1148/radiol.2017162452

    authors: Lee DH,Lee JM,Kang TW,Rhim H,Kim SY,Shin YM,Seo JW,Choi MH,Lee KB

    更新日期:2018-01-01 00:00:00

  • Comparative trial of local pharmacotherapy with L-arginine, r-hirudin, and molsidomine to reduce restenosis after balloon angioplasty of stenotic rabbit iliac arteries.

    abstract:PURPOSE:To determine if local application of L-arginine, r-hirudin, or molsidomine significantly reduces restenosis after balloon angioplasty in stenotic rabbit iliac arteries. MATERIALS AND METHODS:Thirty-one male cholesterol-fed New Zealand white rabbits underwent balloon dilation of both common iliac arteries to in...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.219.3.r01jn27716

    authors: Kalinowski M,Alfke H,Bergen S,Klose KJ,Barry JJ,Wagner HJ

    更新日期:2001-06-01 00:00:00

  • Continuous ultrasound B-scanning of palpable breast masses.

    abstract::Of 210 pathologically confirmed palpable breast masses examined by continuous ultrasound B-scanning using a 2.5- or 7-MHz transducer and mammography, fluid filled cysts more than 1 cm in diameter were diagnosed accurately in 75 cases. Of the 103 solid masses studied by echography, 31 were circumscribed (29 benign fibr...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/117.1.123

    authors: Cole-Beuglet C,Beique RA

    更新日期:1975-10-01 00:00:00

  • Age dependency of the renal resistive index in healthy children.

    abstract::It has recently been suggested that the resistive index (RI) in native kidneys of healthy children is age dependent; however, this relationship has not been completely defined or explained. In 110 kidneys in 71 healthy children aged newborn to 11 years, RIs were determined from peripheral sites (presumed to be arcuate...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.184.2.1620850

    authors: Bude RO,DiPietro MA,Platt JF,Rubin JM,Miesowicz S,Lundquist C

    更新日期:1992-08-01 00:00:00

  • Indeterminate orbital masses: restricted diffusion at MR imaging with echo-planar diffusion-weighted imaging predicts malignancy.

    abstract:PURPOSE:To determine whether magnetic resonance (MR) imaging with diffusion-weighted (DW) imaging can help discriminate between radiologically indeterminate benign and malignant orbital masses and to identify optimal apparent diffusion coefficient (ADC) thresholds for such discrimination. MATERIALS AND METHODS:Informe...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.10091956

    authors: Sepahdari AR,Aakalu VK,Setabutr P,Shiehmorteza M,Naheedy JH,Mafee MF

    更新日期:2010-08-01 00:00:00

  • Cirrhotic nodules: association between MR imaging signal intensity and intranodular blood supply.

    abstract:PURPOSE:To retrospectively determine whether there is a relationship between the intranodular blood supply evaluated at computed tomography (CT) during arterial portography (CTAP) and CT during hepatic arteriography (CTHA) and the magnetic resonance (MR) imaging signal intensity of nodules associated with cirrhosis. M...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2372041389

    authors: Shinmura R,Matsui O,Kobayashi S,Terayama N,Sanada J,Ueda K,Gabata T,Kadoya M,Miyayama S

    更新日期:2005-11-01 00:00:00

  • Imaging characteristics of an amorphous silicon flat-panel detector for digital chest radiography.

    abstract:PURPOSE:To evaluate the imaging characteristics of an amorphous silicon flat-panel detector (FPD) for digital chest radiography. MATERIALS AND METHODS:The 41 x 41-cm digital FPD is constructed on a single monolithic glass substrate with a structured cesium iodide scintillator layer and an amorphous silicon thin-film t...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.218.3.r01fe45683

    authors: Floyd CE Jr,Warp RJ,Dobbins JT 3rd,Chotas HG,Baydush AH,Vargas-Voracek R,Ravin CE

    更新日期:2001-03-01 00:00:00

  • Comparison of the image quality of 105mm film with conventional film.

    abstract::The contrast, resolution, geometric, and motion unsharpness, mottle, and overall impression of 105mm film were compared to these quantities in conventional spot film. It is believed that conventional filming is superior for low contrast objects and cooperative patients whereas with uncooperative, obese patients, the 1...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/118.2.433

    authors: Skucas J,Gorski JW

    更新日期:1976-02-01 00:00:00

  • Use of a gradient intensifying screen for scoliosis radiography.

    abstract::A gradient intensifying screen composed of rare earth phosphors and calcium tungstate was developed. It provides uniform film density when there is a graded increase in subject density. Use of this screen for scoliosis radiography provides an improved image and reduces radiation exposure. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.135.1.7360970

    authors: Ritter EM,Wright CE,Fritz SL,Kirchmer NA,De Smet AA

    更新日期:1980-04-01 00:00:00

  • Computer-aided diagnosis of localized ground-glass opacity in the lung at CT: initial experience.

    abstract::The purpose of this study was to develop an automated scheme to facilitate detection of localized ground-glass opacity (GGO) in the lung at computed tomography (CT). Institutional review board approval and informed consent were not required. Two radiologists reviewed CT images from 14 patients (five men, nine women) w...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2372041461

    authors: Kim KG,Goo JM,Kim JH,Lee HJ,Min BG,Bae KT,Im JG

    更新日期:2005-11-01 00:00:00

  • Lupus nephritis: predictive value of conventional and Doppler US and comparison with serologic and biopsy parameters.

    abstract:PURPOSE:To compare conventional and Doppler ultrasound (US) with clinical and biopsy parameters used to assess disease activity and outcome in lupus nephritis and to assess the predictive value of US. MATERIALS AND METHODS:Thirty-four patients with lupus nephritis prospectively underwent laboratory and US analysis at ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.203.1.9122420

    authors: Platt JF,Rubin JM,Ellis JH

    更新日期:1997-04-01 00:00:00

  • Comparative economic evaluation of data from the ACRIN National CT Colonography Trial with three cancer intervention and surveillance modeling network microsimulations.

    abstract:PURPOSE:To estimate the cost-effectiveness of computed tomographic (CT) colonography for colorectal cancer (CRC) screening in average-risk asymptomatic subjects in the United States aged 50 years. MATERIALS AND METHODS:Enrollees in the American College of Radiology Imaging Network National CT Colonography Trial provid...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.11102411

    authors: Vanness DJ,Knudsen AB,Lansdorp-Vogelaar I,Rutter CM,Gareen IF,Herman BA,Kuntz KM,Zauber AG,van Ballegooijen M,Feuer EJ,Chen MH,Johnson CD

    更新日期:2011-11-01 00:00:00

  • Gallbladder ablation through radiologic intervention: an experimental alternative to cholecystectomy.

    abstract::Twenty pigs underwent (a) cystic duct occlusion by means of fluoroscopically guided transcatheter endoluminal bipolar radio-frequency (RF) electrocoagulation and (b) gallbladder sclerotherapy with one of two different regimens of ethanol and sodium tetradecyl-sulfate (STS). Serum ethanol levels and hepatic enzyme test...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.171.1.2928530

    authors: Becker CD,Quenville NF,Burhenne HJ

    更新日期:1989-04-01 00:00:00

  • Symptomatic benign thyroid nodules: efficacy of additional radiofrequency ablation treatment session--prospective randomized study.

    abstract:PURPOSE:To prospectively evaluate the efficacy of additional radiofrequency (RF) ablation by comparing the results of one and two sessions. MATERIALS AND METHODS:All patients gave written informed consent to participate in this institutional review board-approved prospective study. From September 2007 to February 2008...

    journal_title:Radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1148/radiol.12111300

    authors: Huh JY,Baek JH,Choi H,Kim JK,Lee JH

    更新日期:2012-06-01 00:00:00

  • Ultrasonography and computed tomography of gastric wall lesions.

    abstract::The ultrasonographic features of gastric wall lesions were studied in 40 patients and correlated with the CT findings in 14. Features diagnostic of tumor included (a) an infiltrative lesion causing thickening of the gastric wall, which can be localized or diffuse and smooth or irregular; (b) a globular mass, nodular o...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.141.1.7291520

    authors: Yeh HC,Rabinowitz JG

    更新日期:1981-10-01 00:00:00

  • Pulsed arterial spin labeling: comparison of multisection baseline and functional MR imaging perfusion signal at 1.5 and 3.0 T: initial results in six subjects.

    abstract::Flow-alternating inversion-recovery magnetic resonance imaging was performed at 3.0 T to measure cerebral perfusion during rest and motor activation in six healthy adult volunteers. Results were compared with those at 1.5 T. The mean signal-to-noise ratio for both gray matter and white matter perfusion measured with a...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2222001697

    authors: Yongbi MN,Fera F,Yang Y,Frank JA,Duyn JH

    更新日期:2002-02-01 00:00:00

  • Computer tomography: the "resolving" intracerebral hemorrhage.

    abstract::Two patients with a total of 4 intracerebral hemorrhages were examined by serial computer tomography (CT) over a period of up to 6 months, revealing a progressive decrease in lesion volume and density which eventually became less than that of the surrounding brain tissue. These changes were interpreted as complete clo...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/118.3.609

    authors: Messina AV,Chernik NL

    更新日期:1976-03-01 00:00:00

  • Primary nasopharyngeal carcinoma: diagnostic accuracy of MR imaging versus that of endoscopy and endoscopic biopsy.

    abstract:PURPOSE:To compare the accuracy of magnetic resonance (MR) imaging with that of the current clinical standard of endoscopy and endoscopic biopsy, to determine whether MR imaging depicts subclinical cancers missed at endoscopy and endoscopic biopsy, and to determine whether MR imaging can identify patients without nasop...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.10101241

    authors: King AD,Vlantis AC,Bhatia KS,Zee BC,Woo JK,Tse GM,Chan AT,Ahuja AT

    更新日期:2011-02-01 00:00:00

  • The cathartic colon: pathological findings and radiological/pathological correlation.

    abstract::Cathartic colon has been described radiologically, but the pathological characteristics have not been reported. The authors describe a case in which radiological/pathological correlation was possible, with emphasis on the pathology of the colon. The disease simulates chronic ulcerative colitis radiologically and patho...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/116.3.557

    authors: Urso FP,Urso MJ,Lee CH

    更新日期:1975-09-01 00:00:00

  • Cervical carcinoma: determination of recurrent tumor extent versus radiation changes with MR imaging.

    abstract:PURPOSE:To evaluate the effectiveness of magnetic resonance (MR) imaging for assessment of the present and extent of tumor recurrence as determined with pathologic and surgical findings. MATERIALS AND METHODS:MR findings were retrospectively examined in 37 patients with a history of cervical carcinoma. Inter- and intr...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.194.1.7997540

    authors: Weber TM,Sostman HD,Spritzer CE,Ballard RL,Meyer GA,Clark-Pearson DL,Soper JT

    更新日期:1995-01-01 00:00:00

  • MR guidance of sympathetic nerve blockade: measurement of vasomotor response initial experience in seven patients.

    abstract::The authors performed sympathetic nerve blockades in seven patients with peripheral ischemia and possible autonomic dysfunction. Magnetic resonance (MR) imaging was used to guide needle placement, to monitor distribution of injected agents, and to measure increases in blood flow, which were as much as 10-fold. MR imag...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2231010751

    authors: Sze DY,Mackey SC

    更新日期:2002-05-01 00:00:00

  • Recurrent rectal cancer: diagnosis with dynamic MR imaging.

    abstract:PURPOSE:To evaluate whether dynamic magnetic resonance (MR) imaging can increase the diagnostic accuracy in suspected local recurrence of rectal carcinoma. MATERIALS AND METHODS:Eighteen patients (seven men, 11 women, aged 26-78 years) with 19 suspect lesions were examined. T1-weighted (pre- and postcontrast) and T2-w...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.189.3.8234720

    authors: Müller-Schimpfle M,Brix G,Layer G,Schlag P,Engenhart R,Frohmuller S,Hess T,Zuna I,Semmler W,van Kaick G

    更新日期:1993-12-01 00:00:00

  • Corticospinal tract localization: integration of diffusion-tensor tractography at 3-T MR imaging with intraoperative white matter stimulation mapping--preliminary results.

    abstract::Institutional review board approval and written informed consent were obtained. The purpose of this study was to prospectively validate usefulness of diffusion-tensor (DT) fiber tractography of the corticospinal tract at 3-T magnetic resonance imaging, in combination with the subcortical motor-evoked potential (MEP) t...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2403050916

    authors: Okada T,Mikuni N,Miki Y,Kikuta K,Urayama S,Hanakawa T,Fushimi Y,Yamamoto A,Kanagaki M,Fukuyama H,Hashimoto N,Togashi K

    更新日期:2006-09-01 00:00:00

  • Ultrasonic evaluation of normal pancreatic echogenicity and its relationship to fat deposition.

    abstract::Normal pancreatic ultrasound studies of 28 patients were evaluated as to pancreatic echogenicity and correlated with the morphologic appearance of the pancreas on CT to test the hypothesis that increasing pancreatic echogenicity is related to greater fat infiltration. Statistical analysis indicates that fat is a major...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.137.2.7433680

    authors: Marks WM,Filly RA,Callen PW

    更新日期:1980-11-01 00:00:00

  • Metastasis to regional lymph nodes in patients with esophageal squamous cell carcinoma: CT versus FDG PET for presurgical detection prospective study.

    abstract:PURPOSE:To prospectively compare the accuracy of fluorine 18 fluorodeoxyglucose (FDG) positron emission tomography (PET) and computed tomography (CT) for detection of primary tumor and metastasis to individual lymph node groups and for nodal staging. MATERIALS AND METHODS:From February 2000 to July 2001, 81 patients w...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2281020423

    authors: Yoon YC,Lee KS,Shim YM,Kim BT,Kim K,Kim TS

    更新日期:2003-06-01 00:00:00

  • A technique for the estimation of fractional moving blood volume by using three-dimensional power Doppler US.

    abstract:PURPOSE:To (a) demonstrate an image-processing method that can automatically measure the power Doppler signal in a three-dimensional ( 3D three-dimensional ) ultrasonographic (US) volume by using the location of organs within the image and (b) compare 3D three-dimensional fractional moving blood volume ( FMBV fractiona...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.14132363

    authors: Stevenson GN,Collins SL,Welsh AW,Impey LW,Noble JA

    更新日期:2015-01-01 00:00:00