Abstract:
OBJECTIVES:To review the clinical course, complication rates, and mid-term functional outcomes associated with the treatment of displaced femoral neck stress fractures (FNSFs). DESIGN:Retrospective Case Series. SETTING:Military Tertiary Referral Center. PATIENTS:Twenty-one operatively treated displaced FNSFs between 2002 and 2015. INTERVENTION:Urgent reduction and fixation was performed. If nonunion developed, an intertrochanteric osteotomy was performed. MAIN OUTCOME MEASUREMENTS:Nonunion, osteonecrosis (ON) of the femoral head, conversion to arthroplasty, modified Harris Hip Score, pain score, and Hip Outcome Score (HOS). RESULTS:Two (9.1%) patients developed nonunion. Both united after revision with intertrochanteric osteotomy. ON developed in one patient (4.8%) who was converted to arthroplasty. Average pain score at final follow-up was 2.0 (range 0-5). Average Modified Harris Hip Score was 84 (range 54-100). Average HOS Activities of Daily Living subscale was 80.9 (range 45.6-100). Average HOS Sport subscale was 69.8 (range 27.8-100). Larger displacement on injury films correlated with lower Modified Harris Hip Scores (P = 0.048) and lower HOS Sports Subscale Single Assessment Numeric Evaluation (P = 0.023). The need for an open reduction trended toward being a risk factor for nonunion (P = 0.081). CONCLUSIONS:This study represents the largest series of patients undergoing urgent surgery for displaced FNSFs. Nonunion and ON is found at a similar rate to what is reported in the young traumatic literature. Pain and outcome scores compare favorably to other hip pathology in young adults. Initial injury severity is variably correlated to final outcome scores. LEVEL OF EVIDENCE:Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
journal_name
J Orthop Traumajournal_title
Journal of orthopaedic traumaauthors
Cochran GK,Staeheli GR,Deafenbaugh BK,Kuhn KMdoi
10.1097/BOT.0000000000001810subject
Has Abstractpub_date
2020-11-01 00:00:00pages
594-599issue
11eissn
0890-5339issn
1531-2291pii
00005131-202011000-00006journal_volume
34pub_type
杂志文章abstract:OBJECTIVES:To determine preoperative factors predictive of improvement in pain and function following elective implant removal. We hypothesized that patients undergoing orthopaedic implant removal to relieve pain would have significant improvements in both pain and function. DESIGN:Prospective Cohort Study SETTING:: L...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000001920
更新日期:2020-10-13 00:00:00
abstract::Pilon and ankle fractures and ligamentous injuries about the ankle often require external fixation to allow for soft tissue stabilization before definitive surgery. Often used external fixator constructs can cause obscuring of the site of injury on radiographs, pin tract infections, loosening of calcaenal pin fixation...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e3182604639
更新日期:2013-02-01 00:00:00
abstract::After completing an orthopaedic trauma fellowship, what challenges will you have as regard to maintaining balance and perspective in your new position in society? How will you view yourself, family, and your profession? These are simple suggestions on maintaining passion for your profession. ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,评审
doi:10.1097/BOT.0000000000000431
更新日期:2015-11-01 00:00:00
abstract::A rare case of bilateral atlantoaxial rotatory dislocation (Fielding type V) in an adult is presented. The diagnosis was rapidly made by computed axial tomography. Prior reports of this entity have not clearly defined the pathoanatomy, which in our case was confirmed by three-dimensional tomographic reconstruction. We...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,评审
doi:10.1097/00005131-199402000-00015
更新日期:1994-01-01 00:00:00
abstract:OBJECTIVE:The purpose of the present study was to compare the biomechanical stability of C1 and C2 vertebrae after treatment of ligamentous instability by either modified Brooks posterior wiring (MB) or transarticular screw (TAS) techniques. We hypothesized that the TAS technique would be more stable because of direct ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199909000-00004
更新日期:1999-09-01 00:00:00
abstract:OBJECTIVES:To assess the treatment preferences of orthopaedic surgeons for displaced three- and four-part proximal humerus fractures. DESIGN:Cross-sectional survey. SETTING:Academic and nonacademic institutions across Canada. PATIENTS/PARTICIPANTS:Members of the Canadian Orthopedic Trauma Society and the Joint Ortho...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e3181bdc46a
更新日期:2010-04-01 00:00:00
abstract:OBJECTIVES:To investigate whether a conventional fracture hematoma block (FHB) or an ultrasound-guided peripheral nerve block has more superior analgesic effect during nonoperative management of distal radius fractures in an emergency department setting. Two peripheral nerve block types were investigated, one at the le...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,随机对照试验
doi:10.1097/BOT.0000000000001388
更新日期:2019-04-01 00:00:00
abstract::This report presents a case demonstrating the nonunion of a capital femoral physeal fracture with a large metaphyseal fragment in a 10-year-old boy. To our knowledge, there is no previously reported case of this type of nonunion. The treatment of this nonunion presented a potential risk of premature physeal closure an...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e3181c83a3b
更新日期:2010-08-01 00:00:00
abstract::Compression screws, Ender rods, and Zickel nails were evaluated mechanically to determine their resulting stability in the fixation of experimental subtrochanteric femur osteotomies. Twenty-five pairs of human cadaver femurs were used. Experimental osteotomies were created and a random member of each pair was fixed wi...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199003000-00010
更新日期:1990-01-01 00:00:00
abstract::A simulation study of distal interlocking of an intramedullary nail was performed using newly devised, portable stereo fluoroscopy. Two intramedullary nails in which ten holes were drilled perpendicular to the long axis and at various angles to the diameter were inserted into a femoral and a tibial bone model. Ten dri...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199705000-00014
更新日期:1997-05-01 00:00:00
abstract:BACKGROUND:Accurate prediction of likelihood of reoperation in patients with tibial shaft fractures would facilitate optimal management. Previous studies were limited by small sample sizes and noncomprehensive examination of possible risk factors. OBJECTIVE:We conducted an observational study to determine which progno...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-200305000-00006
更新日期:2003-05-01 00:00:00
abstract::Tibial plateau fractures can involve planes that require reduction and stabilization from a posterior approach. This includes posteromedial, posterolateral, and posterior column shear type injuries. This video outlines the prone posteromedial approach to the tibial plateau for posterior column fracture exposure, reduc...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000001826
更新日期:2020-08-01 00:00:00
abstract:OBJECTIVES:To determine factors associated with angular malalignment of femoral shaft fractures treated with intramedullary nails and to determine differences in the incidence of angular malalignment based on fracture location, fracture comminution, and method of treatment (i.e., antegrade or retrograde). DESIGN:Retro...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-200102000-00003
更新日期:2001-02-01 00:00:00
abstract:OBJECTIVE:Does immediate tibial nail insertion without reaming as part of protocol-driven management provide a safe and effective treatment for open tibia fractures? STUDY DESIGN:Prospective cohort. SETTING:Level 1 trauma center. PATIENTS:A consecutive series of 161 patients with Gustilo grade I-IIIb open tibia frac...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e3180336923
更新日期:2007-03-01 00:00:00
abstract::A prospective randomized study of severe open tibial fractures (Type II and III) was performed. Individual fractures were randomized to treatment groups according to initial antibiotic therapy: One consisted of a first-generation cephalosporin, and the other consisted of a third-generation cephalosporin. Initial antib...
journal_title:Journal of orthopaedic trauma
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1097/00005131-198802030-00001
更新日期:1988-01-01 00:00:00
abstract::Limb salvage was successful in 25 patients treated for severe grade III upper extremity injuries. In a retrospective review of 20 men and five women, follow-up time averaged 26 months. These high-energy injuries were characterized by massive soft-tissue injury, highly comminuted fractures, and significant neurovascula...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:
更新日期:1990-01-01 00:00:00
abstract:OBJECTIVE:Recombinant human bone morphogenetic protein-2 (rhBMP-2) has been shown to enhance new bone formation in fracture and bone defect models in both normal and diabetic rats. Effects of rhBMP-2 in a segmental femoral defect model in diabetes mellitus (DM) BB Wistar rats have not been reported. METHODS:Collagen s...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e31819f290e
更新日期:2009-04-01 00:00:00
abstract::Successful operative intervention in displaced intra-articular calcaneal fractures depends in part on the maintenance of an anatomic reduction of the posterior facet. This guide describes our use of bioabsorbable implants to solve this problem. ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e3181ca38ce
更新日期:2010-12-01 00:00:00
abstract:OBJECTIVES:Fractures of the distal femur are severe injuries that present many clinical challenges. Nonunion, delayed union, implant failure, and the need for secondary procedures can reflect complications of healing. This article reviews the literature on distal femur fractures treated with locking plates to determine...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,评审
doi:10.1097/BOT.0b013e3182070127
更新日期:2011-02-01 00:00:00
abstract::Damage to the brachial artery associated with closed elbow dislocation but without accompanying fracture is rare. Only 25 cases have been reported to date. We present a case that responded well to brachial artery vein grafting, and review the literature on this subject. Operative repair is recommended in this uncommon...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,评审
doi:10.1097/00005131-199312000-00012
更新日期:1993-01-01 00:00:00
abstract:OBJECTIVE:To determine the ability of open reduction and plate fixation to restore articular congruity in the treatment of fractures of the distal radius with intraarticular comminution and displacement. DESIGN:Prospectively followed series. METHODS:Eighteen consecutive fractures of the distal radius with intraarticu...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-200106000-00008
更新日期:2001-06-01 00:00:00
abstract::Obtaining optimal results in the treatment of extraarticular distal tibia fractures can be challenging. Plate and screw and intramedullary fixation have proven to be effective treatments, but are associated with significant complication rates when used for open fractures and patient with severe medical comorbidities. ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000694
更新日期:2016-11-01 00:00:00
abstract::We present a case of 39-year-old female with a scapulothoracic dissociation and acromioclavicular (AC) separation and who had fixation of the AC joint with a locking plate, coracoclavicular screw, and transarticular AC screw. The coracoclavicular and AC relationships were maintained during postoperative rehabilitation...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e3181831352
更新日期:2008-09-01 00:00:00
abstract:OBJECTIVES:Because locked plates as a neutralization device for lag screw fracture fixation have different biomechanics than that of unlocked plates, we investigated how this would affect lag screw load at the fracture site. The purpose of this study was to assess the load at a fracture site compressed with a lag screw...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e31823b3dd1
更新日期:2012-09-01 00:00:00
abstract::Marginal impaction of the acetabulum is typically accessible through fracture planes specific to the nature of the injury. Infrequently, however, incarcerated marginal impaction or free osteochondral fragments are not accessible through these existing fracture planes. As such, alternative methods to access these artic...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000759
更新日期:2017-05-01 00:00:00
abstract::The pull-out strength of two types of bone staples (A, Techmedica; B, Richards) was evaluated in a canine model and compared with a control of 6.5 mm cancellous bone screw (Synthes). Fifteen adult mongrel dogs were divided into three groups of five animals each. The implants were placed in the lateral femoral condyle ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-198701040-00009
更新日期:1987-01-01 00:00:00
abstract:OBJECTIVES:For intramedullary nailing of tibial shaft fractures, a recent study has determined that the entry site should be just medial to the lateral tibial spine at the anterior margin of the articular surface. Gaining access to this site is often through a medial parapatellar or transpatellar approach. Several stud...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-200211000-00001
更新日期:2002-11-01 00:00:00
abstract:INTRODUCTION:Proximal ulna fractures can cause a significant loss of forearm rotation, elbow stiffness, and disability. The objective of this study was to quantify the loss of forearm rotation after simulated varus and valgus malunions of the proximal ulna. METHODS:Eight cadaveric upper extremities were used to quanti...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e31829f5ebc
更新日期:2014-03-01 00:00:00
abstract::Displaced intra-articular fractures of the glenoid are rare and frequently result from high-energy injuries. Types IV, V, and VI fractures have in common a fracture line which extends medially into the scapular body. These fracture patterns present unique challenges for surgical approaches and reduction and fixation s...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,评审
doi:10.1097/BOT.0b013e31817d5356
更新日期:2008-08-01 00:00:00
abstract:OBJECTIVES:To compare the static and dynamic mechanical properties of a modified crossed cannulated screw (CS) configuration, the inverted triangle (IT) cannulated screw configuration, and a compression hip screw (CHS) with derotation screw in Pauwels type III femoral neck fractures. METHODS:Thirty synthetic femora we...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000836
更新日期:2017-07-01 00:00:00