Closed elbow dislocation and brachial artery damage.

Abstract:

:Damage to the brachial artery associated with closed elbow dislocation but without accompanying fracture is rare. Only 25 cases have been reported to date. We present a case that responded well to brachial artery vein grafting, and review the literature on this subject. Operative repair is recommended in this uncommon complication of closed dislocation of the elbow.

journal_name

J Orthop Trauma

authors

Slowik GM,Fitzimmons M,Rayhack JM

doi

10.1097/00005131-199312000-00012

subject

Has Abstract

pub_date

1993-01-01 00:00:00

pages

558-61

issue

6

eissn

0890-5339

issn

1531-2291

journal_volume

7

pub_type

杂志文章,评审
  • Ultrasound-Guided Nerve Blocks as Analgesia for Nonoperative Management of Distal Radius Fractures-Two Consecutive Randomized Controlled Trials.

    abstract:OBJECTIVES:To investigate whether a conventional fracture hematoma block (FHB) or an ultrasound-guided peripheral nerve block has more superior analgesic effect during nonoperative management of distal radius fractures in an emergency department setting. Two peripheral nerve block types were investigated, one at the le...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/BOT.0000000000001388

    authors: Siebelt M,Hartholt KA,van Winden DFM,Boot F,Papathanasiou D,Verdouw BC,de Vries MR,Mathijssen NM,Kraan GA

    更新日期:2019-04-01 00:00:00

  • Impact of an Integrated Hip Fracture Inpatient Program on Length of Stay and Costs.

    abstract:BACKGROUND:Hip fractures are associated with significant morbidity and mortality. Co-management models pairing orthopaedic surgeons with hospitalists or geriatricians may be effective at improving processes of care and outcomes such as length of stay (LOS) and cost. We set out to determine the effect of an integrated h...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000691

    authors: Soong C,Cram P,Chezar K,Tajammal F,Exconde K,Matelski J,Sinha SK,Abrams HB,Fan-Lun C,Fabbruzzo-Cota C,Backstein D,Bell CM

    更新日期:2016-12-01 00:00:00

  • Intraoperative fluoroscopic evaluation of screw placement during pelvic and acetabular surgery.

    abstract::The surgical treatment of pelvic and acetabular fractures can be technically challenging. Various techniques are available for the reconstruction of pelvic and acetabular fractures. Less invasive percutaneous fracture stabilization techniques, with closed reduction or limited open reduction, have been developed and ar...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0b013e318288c0c3

    authors: Yi C,Burns S,Hak DJ

    更新日期:2014-01-01 00:00:00

  • Posteromedial Approach to Tibial Plateau Fracture Nonunion.

    abstract::Tibial plateau fractures can involve planes that require reduction and stabilization from a posterior approach. This includes posteromedial, posterolateral, and posterior column shear type injuries. This video outlines the prone posteromedial approach to the tibial plateau for posterior column fracture exposure, reduc...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001826

    authors: Shields CN,Eftekhary N,Egol KA

    更新日期:2020-08-01 00:00:00

  • Removal of a broken Synthes proximal spiral blade.

    abstract::Use of cephalomedullary nails is an option for treatment of subtrochanteric femur fractures. However, the magnitude of bending forces in this area of the femur often can lead to implant failure before union. We report on a case of hardware failure of a specific device (Synthes spiral blade) and a method for removal. ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199803000-00010

    authors: Stover MD,Lin I,Bosse MJ

    更新日期:1998-03-01 00:00:00

  • Intramedullary nailing of tibial shaft fractures distal to total knee arthroplasty.

    abstract::Tibial shaft fractures distal to total knee arthroplasty are rare, but they are likely to become more common with the increasing number of arthroplasty procedures being performed. These fracture patterns have been treated in the past either with closed reduction and casting/bracing or with open reduction internal fixa...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000096

    authors: Haller JM,Kubiak EN,Spiguel A,Gardner MJ,Horwitz DS

    更新日期:2014-12-01 00:00:00

  • Ipsilateral combination Monteggia and Galeazzi injuries in an adult patient: a case report.

    abstract::Monteggia fractures represent approximately 1 to 2 percent of forearm fractures, whereas Galeazzi fractures represent 3 to 6 percent. The combination of these injuries in the same extremity is an exceedingly rare occurrence. We report a case of ipsilateral combination Monteggia and Galeazzi fractures in an adult patie...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200202000-00011

    authors: Clare DJ,Corley FG,Wirth MA

    更新日期:2002-02-01 00:00:00

  • Avoiding rotational mismatch of locking distal tibia plates depends on proper plate position.

    abstract:OBJECTIVES:The purpose of this study was to evaluate the most appropriate positioning of anatomical locking plates on the distal tibia. METHODS:We positioned 4 types of locking plates (3 straight and 1 bayonet) at anterior, middle, and posterior positions on the medial malleolus on both lower limbs of 15 cadavers. We ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31827cd67d

    authors: Song HK,Noh JW,Lee JH,Yang KH

    更新日期:2013-07-01 00:00:00

  • Modern perspectives of open reduction and plate fixation of proximal humerus fractures.

    abstract::Recent innovations have greatly increased the range of proximal humeral fractures that are amenable to open reduction and plate fixation.The optimum technique for some of the more complex fracture patterns is not yet fully refined.This article aims to describe the recent advances in the treatment of complex proximal h...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0b013e31821c0a2f

    authors: Robinson CM,Amin AK,Godley KC,Murray IR,White TO

    更新日期:2011-10-01 00:00:00

  • Levels of Evidence in Orthopaedic Trauma Literature.

    abstract:OBJECTIVE:To review and critically assess trends observed regarding the levels of evidence in published articles in orthopaedic traumatology literature. DATA SOURCES:The Journal of Orthopaedic Trauma, Journal of Bone and Joint Surgery-American, and Clinical Orthopaedics and Related Research. STUDY SELECTION:All artic...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0000000000000557

    authors: Scheschuk JP,Mostello AJ,Lombardi NJ,Maltenfort MG,Freedman KB,Tjoumakaris FP

    更新日期:2016-07-01 00:00:00

  • Association Between Tibial Malunion Deformity Parameters and Degenerative Hip and Knee Disease.

    abstract:OBJECTIVES:Tibia fractures are the most common long bone fracture. Criteria for closed and open reduction are based on the amount of fracture shortening, angulation, and rotation, with high success rates achieved if acceptable alignment is maintained. However, there exists limited data available regarding the long-term...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000603

    authors: Weinberg DS,Park PJ,Liu RW

    更新日期:2016-09-01 00:00:00

  • Management of severe musculoskeletal injuries of the upper extremity.

    abstract::Limb salvage was successful in 25 patients treated for severe grade III upper extremity injuries. In a retrospective review of 20 men and five women, follow-up time averaged 26 months. These high-energy injuries were characterized by massive soft-tissue injury, highly comminuted fractures, and significant neurovascula...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:

    authors: Levin LS,Goldner RD,Urbaniak JR,Nunley JA,Hardaker WT Jr

    更新日期:1990-01-01 00:00:00

  • Management of humeral nonunion after the failure of locking intramedullary nails.

    abstract::We reviewed 21 cases of humeral nonunion following the failure of "locking" humeral nails. The nails had been inserted as the primary operative procedure following humeral fracture in fifteen cases or after the failure of closed treatment in six cases. Reconstruction after the failure of these implants was complicated...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199610000-00008

    authors: McKee MD,Miranda MA,Riemer BL,Blasier RB,Redmond BJ,Sims SH,Waddell JP,Jupiter JB

    更新日期:1996-01-01 00:00:00

  • Young Practitioners Forum: What Really Matters.

    abstract::After completing an orthopaedic trauma fellowship, what challenges will you have as regard to maintaining balance and perspective in your new position in society? How will you view yourself, family, and your profession? These are simple suggestions on maintaining passion for your profession. ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0000000000000431

    authors: Russell TT

    更新日期:2015-11-01 00:00:00

  • Evaluation of the mangled extremity severity score in combat-related type III open tibia fracture.

    abstract:OBJECTIVES:The purpose of this study was to determine the extent to which the Mangled Extremity Severity Score (MESS) predicted outcomes for soldiers sustaining combat-related Gustilo-Anderson type III open tibia fractures. DESIGN:Retrospective cohort study. SETTING:Tertiary trauma center. PATIENTS:Service Members w...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000054

    authors: Sheean AJ,Krueger CA,Napierala MA,Stinner DJ,Hsu JR,Skeletal Trauma and Research Consortium (STReC).

    更新日期:2014-09-01 00:00:00

  • Mortality after pelvic fractures in the elderly.

    abstract::Theoretically, fissures and minor fractures of the pelvis sustained by the elderly after low-energy trauma may lead to thromboembolic complications. Few studies exist, but clinically, these injuries had been considered to have an excellent prognosis until a recent study reported a 10% fatality rate from pulmonary embo...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/00005131-198906000-00005

    authors: Rossvoll I,Finsen V

    更新日期:1989-01-01 00:00:00

  • Biomechanical evaluation of the less invasive stabilization system for the internal fixation of distal femur fractures.

    abstract:OBJECTIVE:Comparison between a Less Invasive Stabilization System (LISS) using monocortical screws with angular stability and two conventional plate systems Condylar Buttress Plate (CBP) and Dynamic Condylar Screw (DCS) for the treatment of distal femoral fractures with respect to biomechanical properties. DESIGN:Biom...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200109000-00004

    authors: Marti A,Fankhauser C,Frenk A,Cordey J,Gasser B

    更新日期:2001-09-01 00:00:00

  • Far Cortical Locking Fixation of Distal Femur Fractures is Dominated by Shear at Clinically Relevant Bridge Spans.

    abstract:OBJECTIVES:Far cortical locking (FCL) constructs have been shown to increase axial interfragmentary displacement while limiting shear and have been specifically recommended in the treatment of distal femur fractures. However, there is no available data regarding their mechanical behavior within the range of bridge span...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001341

    authors: Habet N,Elkins J,Peindl R,Killen C,Lack WD

    更新日期:2019-02-01 00:00:00

  • Hexapod Stacked Transport for Tibial Infected Nonunions With Bone Loss: Long-Term Functional Outcomes.

    abstract:OBJECTIVES:To analyze long-term functional outcomes in patients with posttraumatic infected tibial nonunions having undergone bone transport with hexapod external fixator. DESIGN:Retrospective cohort study. SETTING:Level 1 trauma center. PATIENTS/PARTICIPANTS:Thirty-eight patients with infected nonunions of the tibi...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001005

    authors: Napora JK,Weinberg DS,Eagle BA,Kaufman BR,Sontich JK

    更新日期:2018-01-01 00:00:00

  • Valgus osteotomy of the proximal femur with sliding hip screw for the treatment of femoral neck nonunions: the technique, a case series, and literature review.

    abstract::Femoral neck nonunions are a difficult complication in the treatment of femoral neck fractures and have traditionally been managed using an intertrochanteric valgus osteotomy and blade plate. We propose an alternative method, a proximal femoral valgus osteotomy using a sliding hip screw instead of a blade plate. This ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/00005131-200608000-00006

    authors: Schoenfeld AJ,Vrabec GA

    更新日期:2006-07-01 00:00:00

  • Comparison of Early Fatigue Failure of the TFNa and Gamma 3 Cephalomedullary Nails in the United States From 2015 to 2019.

    abstract:OBJECTIVES:To compare reports of implant fatigue failure submitted to the FDA of 2 commonly used cephalomedullary nails. METHODS:In total, 2724 medical device reports from the FDA's MAUDE database from Jan 2015 to Oct 2019 were reviewed for the Trochanteric Femoral Nail-Advanced (TFNa) and Gamma 3 implants. RESULTS:D...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001864

    authors: Klima ML

    更新日期:2021-02-01 00:00:00

  • Femoral cortical stress lesions in long-term bisphosphonate therapy: a herald of impending fracture?

    abstract:OBJECTIVE:Lateral cortical stress reactions have been documented to precede femoral insufficiency fractures after long-term bisphosphonate therapy. We studied the natural history of femoral stress lesions associated with long-term bisphosphonate therapy. DESIGN AND SETTING:A retrospective clinical and radiologic revie...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181b6499b

    authors: Koh JS,Goh SK,Png MA,Kwek EB,Howe TS

    更新日期:2010-02-01 00:00:00

  • Internal fixation with a self-compressing plate and lag screw: improvements of the plate hole and screw design. 2. In vivo investigations.

    abstract::A mechanically improved design of bone plate and screw was compared in vivo with conventional plate fixation. This method was investigated biologically in a standardized osteotomy model on sheep tibiae. It was found that maintenance of reduction of an osteotomy was facilitated and there was no adverse effect of this f...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199109000-00006

    authors: Klaue K,Kowalski M,Perren SM

    更新日期:1991-01-01 00:00:00

  • Inadvertent intraforaminal iliosacral screw placement despite apparent appropriate positioning on intraoperative fluoroscopy.

    abstract::We present the case of an intraforaminal iliosacral screw placed percutaneously with aid of C-arm using inlet, outlet, and lateral views of the pelvis. The iliosacral screw was placed above the S1 foramen on the outlet view, into the middle of S1 via the ala on the inlet view, and below the cortical shadow of the ala ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200502000-00010

    authors: Sagi HC,Lindvall EM

    更新日期:2005-02-01 00:00:00

  • Pathomechanical significance of radial head subluxation in the onset of osteochondritis dissecans of the radial head.

    abstract::Osteochondritis dissecans of the elbow mainly involves the capitellum; however, no authors have reported the condition in the radial head with subluxation of the radial head. We report four cases in which osteochondritis dissecans involved the radial head and was accompanied by radial head subluxation. All patients we...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318214d678

    authors: Tatebe M,Hirata H,Shinohara T,Yamamoto M,Morita A,Horii E

    更新日期:2012-01-01 00:00:00

  • Ulnar-styloid nonunion and partial rupture of extensor carpi ulnaris tendon: two case reports and review of the literature.

    abstract::Two unusual cases of symptomatic partial rupture of the extensor carpi ulnaris tendon associated with ulnar-styloid nonunion are described. Intraoperative findings suggested that the jagged surface of the distal ulna was the cause of flaying. In one case, debridement of the frayed extensor carpi ulnaris tendon and fix...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/00005131-200210000-00011

    authors: Kiyono Y,Nakatsuchi Y,Saitoh S

    更新日期:2002-10-01 00:00:00

  • Management of distal humerus fractures with minifragment fixation.

    abstract::Minifragment implants provide several advantages for the stabilization of distal humerus fractures. Compared with small fragment implants, minifragment implants may provide enhanced fracture fixation because a greater number of screws can be placed into the distal fragments. In addition, minifragment plates are easier...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/01.bot.0000157908.45939.d7

    authors: Russell GV Jr,Jarrett CA,Jones CB,Cole PA,Gates J

    更新日期:2005-08-01 00:00:00

  • Use of the reamer irrigator aspirator for the treatment of a 20-year recurrent osteomyelitis of a healed femur fracture.

    abstract:SUMMARY:In the following case, a 20-year-old male was involved in a motorcycle accident where he sustained an open midshaft femur fracture treated with open reduction and internal fixation. Several weeks later, the wound became infected and the plate was removed. Over the following 20 years numerous incision and debrid...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318051532d

    authors: Bellapianta J,Gerdeman A,Sharan A,Lozman J

    更新日期:2007-05-01 00:00:00

  • The use of a biodegradable, load-bearing scaffold as a carrier for antibiotics in an infected open fracture model.

    abstract:OBJECTIVES:Open fractures with bone loss are common, disabling injuries. Biodegradable, load-bearing scaffolds able to carry high concentrations of local antibiotics are an emerging technology to address these injuries. This study investigates the use of such scaffolds with gentamicin (along with bone morphogenetic pro...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181ed1349

    authors: Stewart RL,Cox JT,Volgas D,Stannard J,Duffy L,Waites KB,Chu TM

    更新日期:2010-09-01 00:00:00

  • Non-invasive low-intensity pulsed ultrasound accelerates bone healing in the rabbit.

    abstract::The effect of ultrasound (US) on the rate of fibula osteotomy healing in 139 mature New Zealand white rabbits was assessed in this study. Bilateral midshaft fibular osteotomies were made using a 1-mm Gigli saw. US was noninvasively applied to one limb for 20 minutes daily, while the contralateral limb served as a cont...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199004030-00002

    authors: Pilla AA,Mont MA,Nasser PR,Khan SA,Figueiredo M,Kaufman JJ,Siffert RS

    更新日期:1990-01-01 00:00:00