Abstract:
OBJECTIVES:To determine factors associated with angular malalignment of femoral shaft fractures treated with intramedullary nails and to determine differences in the incidence of angular malalignment based on fracture location, fracture comminution, and method of treatment (i.e., antegrade or retrograde). DESIGN:Retrospective. SETTING:Level I trauma center. PATIENTS:Three hundred sixty patients with 374 femoral shaft fractures were identified from a prospectively obtained orthopaedic trauma database. Complete sets of immediate postoperative anteroposterior and lateral radiographs were available for 355 (95 percent) of the 374 fractures. INTERVENTION:Patients were treated with antegrade (183 cases) or retrograde (174 cases) intramedullary femoral nailing. MAIN OUTCOME MEASURE:Goniometric measurements were made on all immediate postoperative radiographs to determine the coronal plane and sagittal plane angular alignments. A multiple linear regression statistical analysis was used to determine factors associated with increasing angular malalignment. The incidence of malalignment was determined using more than 5 degrees of deformity in any plane as the definition of malalignment. RESULTS:Proximal fracture location, distal fracture location, and unstable fracture pattern were associated with increasing fracture angulation (p < 0.001). Fracture location in the middle third, stable fracture pattern, method of treatment (i.e., antegrade or retrograde), and nail diameter were not associated with increasing fracture angulation (p > 0.05). The incidence of malalignment was 9 percent for the entire group of patients, 30 percent when the fracture was of the proximal third of the femoral shaft, 2 percent when the fracture was of the middle third, and 10 percent when the fracture was of the distal third. The incidence of malreduction was 7 percent for patients with stable fracture patterns and 12 percent for those with unstable fracture patterns. CONCLUSIONS:Patients with fractures of the proximal third of the femoral shaft treated with intramedullary nails are at highest risk for malalignment. Proximal fracture location, distal fracture location, and unstable fracture pattern are associated with increasing fracture angulation.
journal_name
J Orthop Traumajournal_title
Journal of orthopaedic traumaauthors
Ricci WM,Bellabarba C,Lewis R,Evanoff B,Herscovici D,Dipasquale T,Sanders Rdoi
10.1097/00005131-200102000-00003subject
Has Abstractpub_date
2001-02-01 00:00:00pages
90-5issue
2eissn
0890-5339issn
1531-2291journal_volume
15pub_type
杂志文章abstract::Tibial shaft fractures distal to total knee arthroplasty are rare, but they are likely to become more common with the increasing number of arthroplasty procedures being performed. These fracture patterns have been treated in the past either with closed reduction and casting/bracing or with open reduction internal fixa...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000096
更新日期:2014-12-01 00:00:00
abstract:OBJECTIVE:A new device for the treatment of intertrochanteric fractures that uses 2 cephalocervical screws in an integrated mechanism allowing linear intraoperative compression and rotational stability of the head/neck fragment has been developed. The aim of this study was to describe the results using this device for ...
journal_title:Journal of orthopaedic trauma
pub_type: 临床试验,杂志文章
doi:10.1097/BOT.0b013e31819211b2
更新日期:2009-01-01 00:00:00
abstract:PURPOSE:The purpose of this OTA-approved pilot study was to compare the clinical and functional outcomes of the knee joint after infrapatellar (IP) versus suprapatellar (SP) tibial nail insertion. DESIGN:Prospective, randomized. SETTING:Level I trauma center. METHODS:After institutional review board approval, skelet...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,随机对照试验
doi:10.1097/BOT.0000000000000499
更新日期:2016-03-01 00:00:00
abstract::Although Kirschner wires are useful implants in many situations, migration of the wire and irritation of the surrounding soft tissues are common complications. Seven steps are described herein, which result in a Kirschner wire that is bent 180° angle, providing a smooth anchor into bone. Use of this technique produces...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e318290f818
更新日期:2013-11-01 00:00:00
abstract:OBJECTIVE:To determine if a dual-purpose bone graft can regenerate bone and reduce infection in highly contaminated bone critical size defects in rats. METHODS:Biodegradable polyurethane (PUR) scaffolds were loaded with recombinant human bone morphogenetic protein-2 (BMP-2) and vancomycin (Vanc). The release kinetics ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e31821f624c
更新日期:2011-08-01 00:00:00
abstract:OBJECTIVES:To determine if there are differences in healing, complications, or number of procedures required to obtain union among open and closed tibia fractures treated with intramedullary (IM) nails inserted with and without reaming. DESIGN:Prospective, surgeon-randomized comparative study. SETTING:Level One traum...
journal_title:Journal of orthopaedic trauma
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1097/00005131-200003000-00007
更新日期:2000-03-01 00:00:00
abstract:OBJECTIVE:The optimal exposure interval for anteromedial coronoid fractures is unknown. The purpose of this study was to quantitatively compare the osseous and ligamentous exposure of the medial elbow using the flexor carpi ulnaris (FCU)-Splitting and Hotchkiss Over-the-Top approaches. METHODS:Forty surgical approache...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e31828ba91c
更新日期:2013-12-01 00:00:00
abstract:PURPOSE:Comminuted iliac fractures are uncommon and difficult to treat. The purpose of this study is to further delineate the fractures, to present a management protocol, and to evaluate the results of treatment. DESIGN:Retrospective clinical study. SETTING:Level one trauma center at Harborview Medical Center. PATIE...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-200005000-00008
更新日期:2000-05-01 00:00:00
abstract::Periprosthetic humerus fractures are relatively uncommon occurrence that can be difficult to manage nonoperatively. Locking plate technology has enhanced the surgical management of these fractures. However, adequate fixation around the stem remains of some concern. We describe an osteosynthesis technique using a locki...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000646
更新日期:2016-11-01 00:00:00
abstract:OBJECTIVE:To evaluate the difference in quality of fracture reduction between the sinus tarsi approach (STA) and extensile lateral approach (ELA) using postoperative CT scans in displaced intra-articular calcaneal fractures (DIACFs). DESIGN:Retrospective SETTING:: Level 1 and Level 2 academic centers. PATIENTS:Consec...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000001971
更新日期:2020-09-18 00:00:00
abstract::Femoral shaft fractures are commonly treated with closed reduction and reamed intramedullary nailing. However, some reductions are difficult to obtain or maintain, especially in muscular or large patients. When closed methods fail to achieve reduction, percutaneous techniques are extremely useful. In addition, the use...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000890
更新日期:2017-08-01 00:00:00
abstract:SUMMARY:In this study, we present a novel technique for reduction and fixation of complex, unstable proximal humerus fractures with diaphyseal extension with the assistance of fibula allograft. We treated 14 patients using this technique since 2009 and found that it improves the reduction and enhances fixation while ma...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e31829a346d
更新日期:2014-03-01 00:00:00
abstract:OBJECTIVE:The purpose of this study was to compare the relative stiffness of four common external fixation (XF) configurations used to span and stabilize the knee after knee dislocation. METHODS:Synthetic composite femora and tibiae connected with cords were used to simulate a knee. Four configurations of external fix...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e3181e3cd4b
更新日期:2010-11-01 00:00:00
abstract:OBJECTIVES:To propose a new fracture classification according to the direction of epiphysis displacement and to compare clinical findings and surgical outcomes between these subtypes. DESIGN:Retrospective study. SETTING:A tertiary referral hospital. PATIENTS:Twelve adolescents (mean age, 13.4 ± 1.3 years) who experi...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000060
更新日期:2014-08-01 00:00:00
abstract:OBJECTIVE:The aim of this study was to report the clinical results of atypical femoral fractures (AFFs) treated with low-intensity pulsed ultrasound (LIPUS). MATERIALS AND METHODS:The data on AFFs that were surgically treated in our hospital from 2010 to 2016 was retrospectively analyzed. AFF was diagnosed based on th...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/01.bot.0000520889.69599.f3
更新日期:2017-07-01 00:00:00
abstract:OBJECTIVE:To determine the impact of smoking on intensive care unit (ICU) outcomes in patients who underwent operative fixation for spine trauma. DESIGN:Retrospective cohort study. SETTING:Single academic level I trauma center. PATIENTS:One hundred eighty-one consecutive surgical spine trauma patients from January 2...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000001739
更新日期:2020-07-01 00:00:00
abstract::Results of hemiarthroplasty for complex four-part proximal humerus fractures in the elderly have been unreliable. Although patients often achieve pain relief, return of above-shoulder level function can be challenging, because tuberosity nonunion, malunion, and/or resorption is quite common. The reverse shoulder repla...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e3181f22088
更新日期:2011-05-01 00:00:00
abstract:OBJECTIVES:To determine whether uncemented implants would provide similar outcomes while avoiding the complications associated with cement in the treatment of elderly patients with proximal humerus fractures (PHFs) with primary reverse total shoulder arthroplasty (RTSA). DESIGN:Case series. SETTING:A single Level I t...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000001465
更新日期:2019-07-01 00:00:00
abstract:OBJECTIVE:To quantify intrapelvic surface symmetry in reference to a preshaped suprapectineal acetabular implant. METHODS:In this cross-sectional study, an anatomically preshaped acetabular fracture implant was fitted on 3D surface models of 516 pelvises from a preexisting bone database using a software tool for autom...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000001373
更新日期:2019-03-01 00:00:00
abstract::The use of Ender nails for the treatment of femoral shaft fractures has been described as technically easier and less time consuming than current intramedullary nailing techniques. We reviewed our results with unlocked Ender nails in 26 stable and 17 unstable fracture patterns an average of 3-4 years after injury. Bec...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199209000-00008
更新日期:1992-01-01 00:00:00
abstract::In physiologically young patients with displaced femoral neck fractures, surgical treatment is aimed at achieving fracture union while preserving native hip anatomy and biomechanics. The intracapsular environment, tenuous vascular supply, and unfavorable hip biomechanics contribute to the high complication rates seen ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,评审
doi:10.1097/BOT.0000000000001368
更新日期:2019-01-01 00:00:00
abstract:OBJECTIVES:Evaluate the effect of the COVID-19 pandemic and the "shelter-in-place" order on orthopaedic trauma presenting to a community level II trauma center. It is hypothesized the overall number of orthopaedic trauma encounters (OTE), the number of OTEs related to both high and low severity injuries, as well as the...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000001860
更新日期:2020-06-08 00:00:00
abstract::Standard 5-mm AO Schanz pedicle screws were biomechanically compared with a new design, featuring 6-mm threads with a 5-mm core diameter continuous with the shaft. One each of the two screw designs was surgically inserted into the matching pedicles of 32 cadaveric vertebrae. The pull-out strengths of the screws were t...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199308000-00015
更新日期:1993-01-01 00:00:00
abstract:OBJECTIVE:To determine the effectiveness of exchange reamed nails for treatment of aseptic femoral delayed unions and nonunions. DESIGN:Retrospective chart review. PATIENTS:Nineteen patients admitted to the Carolinas Medical Center Level I trauma center from 1990 to 1996 for repair of femoral shaft fracture nonunion ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-200006000-00005
更新日期:2000-06-01 00:00:00
abstract:OBJECTIVES:To determine whether there is a patient-reported functional difference between combat-related knee disarticulations (KDs) and transfemoral amputations (TFAs). SETTING:Role 3 Military Trauma Centers. PATIENTS:We identified and contacted all KDs and TFAs performed at the Walter Reed National Military Medical...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000001440
更新日期:2019-06-01 00:00:00
abstract:OBJECTIVES:To determine the rates of infection in low-energy gunshot wounds (GSWs) to the extremity. DESIGN:Retrospective review. SETTING:Level I trauma center. PATIENTS/PARTICIPANTS:Patients (N = 140) with at least 90-day follow-up for extremity-only low-energy GSW injuries from 2010-2014 were retrospectively revie...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000827
更新日期:2017-06-01 00:00:00
abstract:OBJECTIVES:This study compared the acute treatment effects of systemic analgesics with (celecoxib) and without anti-inflammatory activity (acetaminophen) on bone fracture healing. STUDY DESIGN:Longitudinal time study of fracture healing in rats. METHODS:Closed, mid diaphyseal femur fractures were produced in female S...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/01.bot.0000184144.98071.5d
更新日期:2005-11-01 00:00:00
abstract:OBJECTIVES:To compare radiographic and clinical outcomes of supination external rotation type IV equivalent (SER IV E) ankle fractures (AO/OTA classification 44-B2.1) treated with transsyndesmotic screw fixation with those treated with deltoid and posterior inferior tibiofibular ligament (PITFL) repair. DESIGN:Case se...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000318
更新日期:2015-05-01 00:00:00
abstract:OBJECTIVE:Presentation of a new triangular osteosynthesis technique that permits early weight-bearing in vertically unstable sacral fractures. DESIGN:Retrospective evaluation of a consecutive series. SETTING:Level I trauma center. PATIENTS:Thirty-four patients, twenty-eight of whom were polytraumatized, all with ver...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199806000-00002
更新日期:1998-06-01 00:00:00
abstract::A modified freehand method using a cannulated drill bit for the insertion of distal locking screws for interlocking intramedullary nails is described. It should be useful to introduce surgeons to interlocking and to aid those who are not comfortable with the freehand method. ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199306000-00009
更新日期:1993-01-01 00:00:00