Abstract:
:Technical advances towards high resolution PET imaging try to overcome the inherent physical limitations to spatial resolution. Positrons travel in tissue until they annihilate into the two gamma photons detected. This range is the main detector-independent contribution to PET imaging blurring. To a large extent, it can be remedied during image reconstruction if accurate estimates of positron range are available. However, the existing estimates differ, and the comparison with the scarce experimental data available is not conclusive. In this work we present positron annihilation distributions obtained from Monte Carlo simulations with the PeneloPET simulation toolkit, for several common PET isotopes ((18)F, (11)C, (13)N, (15)O, (68)Ga and (82)Rb) in different biological media (cortical bone, soft bone, skin, muscle striated, brain, water, adipose tissue and lung). We compare PeneloPET simulations against experimental data and other simulation results available in the literature. To this end the different positron range representations employed in the literature are related to each other by means of a new parameterization for positron range profiles. Our results are generally consistent with experiments and with most simulations previously reported with differences of less than 20% in the mean and maximum range values. From these results, we conclude that better experimental measurements are needed, especially to disentangle the effect of positronium formation in positron range. Finally, with the aid of PeneloPET, we confirm that scaling approaches can be used to obtain universal, material and isotope independent, positron range profiles, which would considerably simplify range correction.
journal_name
Phys Med Bioljournal_title
Physics in medicine and biologyauthors
Cal-González J,Herraiz JL,España S,Corzo PM,Vaquero JJ,Desco M,Udias JMdoi
10.1088/0031-9155/58/15/5127subject
Has Abstractpub_date
2013-08-07 00:00:00pages
5127-52issue
15eissn
0031-9155issn
1361-6560journal_volume
58pub_type
杂志文章abstract::A phantom study for dosimetry in the urethra using alanine/ESR during (192)Ir HDR brachytherapy of prostate cancer is presented. The measurement method of the secondary standard of the Physikalisch-Technische Bundesanstalt had to be slightly modified in order to be able to measure inside a Foley catheter. The absorbed...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/54/9/022
更新日期:2009-05-07 00:00:00
abstract::In robotic radiosurgery, it is necessary to compensate for systematic latencies arising from target tracking and mechanical constraints. This compensation is usually achieved by means of an algorithm which computes the future target position. In most scientific works on respiratory motion prediction, only one or two a...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/58/11/3911
更新日期:2013-06-07 00:00:00
abstract::The fluence to organ-dose and effective-dose conversion coefficients for neutrons and protons with energies up to 100 GeV was calculated using the PHITS code coupled to male and female adult reference computational phantoms, which are to be released as a common ICRP/ICRU publication. For the calculation, the radiation...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/54/7/009
更新日期:2009-04-07 00:00:00
abstract::An accurate, low noise estimate of photon attenuation in the subject is required for quantitative microPET studies of molecular tracer distributions in vivo. In this work, several transmission-based measurement techniques were compared, including coincidence mode with and without rod windowing, singles mode with two d...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/51/16/008
更新日期:2006-08-21 00:00:00
abstract::The measurement of output factors (OF) for the small photon beams generated by Leksell Gamma Knife® (LGK) radiotherapy units is a challenge for the physicist due to the under or over estimation of these factors by a vast majority of the detectors commercially available. Output correction factors, introduced in the int...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/60/10/3959
更新日期:2015-05-21 00:00:00
abstract::In critical organ in vivo x-ray dosimetry, the relative contaminating electron contribution to the total dose and total detector response outside the field will be different to the corresponding contributions at the central axis detector calibration position, mainly due to the effects of shielding in the linear accele...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/51/24/013
更新日期:2006-12-21 00:00:00
abstract::This paper describes an accurate and time-efficient method for the determination of total body potassium via a combination of measurements in the Birmingham whole body counter and the use of the Monte Carlo n-particle (MCNP) simulation code. In developing this method, MCNP has also been used to derive values for some ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/51/17/009
更新日期:2006-09-07 00:00:00
abstract::Measurements of lung nodule volume with multi-detector computed tomography (MDCT) have been shown to be more accurate and precise compared to conventional lower dimensional measurements. Quantifying the size of lesions is potentially more difficult when the object-to-background contrast is low as with lesions in the l...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/60/2/671
更新日期:2015-01-21 00:00:00
abstract::Many applications in medical imaging include image registration for matching of images from the same or different modalities. In the case of full data sampling, the respective reconstructed images are usually of such a good image quality that standard deformable volume-to-volume (3D-3D) registration approaches can be ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/59/24/7865
更新日期:2014-12-21 00:00:00
abstract::Over the last decade, the performance of benchtop x-ray fluorescence computed tomography (XFCT) systems has been significantly enhanced through hardware and software optimizations. Recent studies have indicated the need of energy-resolving pixelated/array detectors in the x-ray detection component to further improve t...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab9774
更新日期:2020-08-31 00:00:00
abstract::Cardiac and respiratory motion artefacts in PET imaging have been traditionally resolved by acquiring the data in gated mode. However, gated PET images are usually characterized by high noise content due to their low photon statistics. In this paper, we present a novel 4D model for the PET imaging system, which can in...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/51/15/012
更新日期:2006-08-07 00:00:00
abstract::The use of liquid ionization chambers in radiotherapy has grown during the past few years. While for air ionization chambers the k(TP) correction for air mass density due to pressure and temperature variations is well known, less work has been done on the case of liquid ionization chambers, where there is still the ne...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/59/11/2705
更新日期:2014-06-07 00:00:00
abstract::In carbon ion therapy treatment planning, the relative biological effectiveness (RBE) is accounted for by optimization of the RBE-weighted dose (biological dose). The RBE calculation methods currently applied clinically in carbon ion therapy are derived from the microdosimetric kinetic model (MKM) in Japan and the loc...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aae8b4
更新日期:2018-11-12 00:00:00
abstract::Dynamic PET image reconstruction is a challenging issue due to the low SNR and the large quantity of spatio-temporal data. We propose a robust state-space image reconstruction (SSIR) framework for activity reconstruction in dynamic PET. Unlike statistically-based frame-by-frame methods, tracer kinetic modeling is inco...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/56/8/010
更新日期:2011-04-21 00:00:00
abstract::Dose measurements following 10 min irradiations with a portable x-ray fluorescence spectrometer composed of a miniature x-ray tube and a silicon PiN diode detector were performed using thermoluminescent dosimeters consisting of LiF:Mg,Ti chips of 3 mm diameter and 0.4 mm thickness. The table-top setup of the spectrome...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/55/18/015
更新日期:2010-09-21 00:00:00
abstract::We introduce a novel x-ray imaging approach that yields information about the local texture of structures smaller than the image pixel resolution inside an object. The approach is based on a recently developed x-ray dark-field imaging technique, using scattering from sub-micron structures in the sample. We show that t...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/55/12/004
更新日期:2010-06-21 00:00:00
abstract::For medical applications of ultrasound inside the brain, it is necessary to understand the relationship between the apparent density of skull bone and its corresponding speed of sound and attenuation coefficient. Although there have been previous studies exploring this phenomenon, there is still a need to extend the m...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/56/1/014
更新日期:2011-01-07 00:00:00
abstract::There are a number of gel dosimeter calibration methods in contemporary usage. The present study is a detailed Monte Carlo investigation into the accuracy of several calibration techniques. Results show that for most arrangements the dose to gel accurately reflects the dose to water, with the most accurate method invo...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/52/13/022
更新日期:2007-07-07 00:00:00
abstract::A method for registering images acquired from a prototype flat panel mobile C-arm, capable of kilovoltage (kV) cone-beam computed tomography (CT), to a linear accelerator (LINAC) isocenter is presented. A calibration procedure is performed which involves locating reflective markers placed on the C-arm and a phantom in...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/52/12/005
更新日期:2007-06-21 00:00:00
abstract::Segmented attenuation correction is now a widely accepted technique to reduce noise propagation from transmission scanning in positron emission tomography (PET). In this paper, we present a new method for segmenting transmission images in whole-body scanning. This reduces the noise in the correction maps while still c...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/47/7/310
更新日期:2002-04-07 00:00:00
abstract::A method for simulating spot-scanned delivery to a moving tumour was developed which uses patient-specific image and plan data. The magnitude of interplay effects was investigated for two patient cases under different fractionation and respiratory motion variation scenarios. The use of volumetric rescanning for motion...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/56/20/003
更新日期:2011-10-21 00:00:00
abstract::Both inhomogeneity in the main magnetic field and non-linearity in the gradient fields introduce errors in NMR images reconstructed from projections. It is found that the image artefacts caused by these two sources are separable. The inhomogeneous main field blurs the image while the nonlinear gradients distort the im...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/28/8/005
更新日期:1983-08-01 00:00:00
abstract::Measurements of standardized uptake values (SUV) can vary due to many causes, including respiratory motion. Various methodologies have been introduced to correct for motion in PET, with quiescent-period-gated (QPG) PET being the most popular approach. QPG has been shown to improve PET image quantification compared to ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab1cdd
更新日期:2019-05-16 00:00:00
abstract::In dynamic renal scintigraphy, the main interest is the radiopharmaceutical redistribution as a function of time. Quality control (QC) of renal procedures often relies on phantom experiments to compare image-based results with the measurement setup. A phantom with a realistic anatomy and time-varying activity distribu...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/58/10/3145
更新日期:2013-05-21 00:00:00
abstract::The aim of this paper is to determine the dosimetric impact of trace elements in human tissues for low-energy photon sources used in brachytherapy. Monte Carlo dose calculations were used to investigate the dosimetric effect of trace elements present in normal or cancerous human tissues. The effect of individual trace...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/57/11/3585
更新日期:2012-06-07 00:00:00
abstract::The S-value is a standard measure in cellular dosimetry. S-values are calculated by applying analytical methods or by Monte Carlo simulation. In Monte Carlo simulation, particles are either tracked individually event-by-event or close events are condensed and processed collectively in different steps. Both of these me...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/62/5/N90
更新日期:2017-03-07 00:00:00
abstract::It is difficult to test near-infrared spectrophotometry instruments in vivo. Therefore we constructed a liquid phantom which mimics the neonatal head. It consists of a spherical 3.5 mm thick layer of silicone rubber simulating skin and bone and a 0.5 mm thick clear layer of polypropylene imitating cerebrospinal fluid....
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/44/7/313
更新日期:1999-07-01 00:00:00
abstract::The peak CT number (CT) and full width at half maximum (FWHM) were obtained from the image profiles of aluminium of thickness ranging from 0.1-9.5 mm. The scans were performed at different fields of view (FOVs) and with different reconstruction algorithms ('bone' and 'standard'). Above 3 mm, CT and FWHM provide measur...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/43/3/013
更新日期:1998-03-01 00:00:00
abstract::An in vivo method for the determination of Cd levels in human kidney and liver has been developed. The method allows detection of absolute quantities of Cd in the left kidney and Cd concentration in the liver. The limit of detection of cadmium is 2.5 mg for the left kidney and 1.8 microgram/g (wet weight) for the live...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/22/6/003
更新日期:1977-11-01 00:00:00
abstract::The theory of task-based assessment of image quality is reviewed in the context of imaging with ionizing radiation, and objective figures of merit (FOMs) for image quality are summarized. The variation of the FOMs with the task, the observer and especially with the mean number of photons recorded in the image is discu...
journal_title:Physics in medicine and biology
pub_type: 杂志文章,评审
doi:10.1088/0031-9155/60/2/R1
更新日期:2015-01-21 00:00:00