Lower-extremity in situ saphenous vein grafts: angiographic interventions.

Abstract:

:In 16 consecutive patients, thrombosis, anastomotic and intragraft stenoses, and residual venous communications (arteriovenous fistulas [AVFs]), after in situ saphenous vein bypass of femoropopliteal and infrapopliteal arteries, were treated with interventional angiographic techniques. Streptokinase infusion for graft thrombosis was performed in four patients, with long-term clinical improvement in two; in the other two, early rethrombosis was treated with surgical thrombectomy. Delayed rethrombosis occurred at 13 months in another patient. Anastomotic (six occasions) and intragraft (four occasions) stenoses in six patients were dilated with percutaneous transluminal angioplasty (PTA). Two grafts subsequently occluded, one 3 weeks and one 3 months after PTA. Residual AVFs were occluded in ten patients. Ten of 16 patients remained clinically improved without further therapy. One complication occurred: A graft stenosis developed at the site where a coil, protruding from the AVF into the graft lumen, was successfully removed and replaced.

journal_name

Radiology

journal_title

Radiology

authors

Sniderman KW,Kalman PG,Shewchun J,Goldberg RE

doi

10.1148/radiology.170.3.2521740

subject

Has Abstract

pub_date

1989-03-01 00:00:00

pages

1023-7

issue

3 Pt 2

eissn

0033-8419

issn

1527-1315

journal_volume

170

pub_type

杂志文章
  • Joint effusions: MR imaging.

    abstract::Magnetic resonance (MR) images of the hips and knees of three healthy volunteers were reviewed and compared with images obtained from the hips of three patients with effusions. Comparison was also made with MR images obtained from two swine knees following the injections of saline in one and blood in the other. The an...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.158.1.3940370

    authors: Beltran J,Noto AM,Herman LJ,Mosure JC,Burk JM,Christoforidis AJ

    更新日期:1986-01-01 00:00:00

  • Electrotransfer at MR imaging: tool for optimization of gene transfer protocols--feasibility study in mice.

    abstract:PURPOSE:To test, by using an electrotransfer protocol for the transfection of skeletal muscle with naked plasmid complementary DNA, whether in vivo magnetic resonance (MR) imaging can help delineate either the spatial extent of the electric field when contrast agent is injected intraperitoneally or the transfection are...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2283020482

    authors: Paturneau-Jouas M,Parzy E,Vidal G,Carlier PG,Wary C,Vilquin JT,de Kerviler E,Schwartz K,Leroy-Willig A

    更新日期:2003-09-01 00:00:00

  • Carotid artery invasion by head and neck masses: prediction with MR imaging.

    abstract:PURPOSE:To determine the value of magnetic resonance (MR) imaging in predicting resectability of head and neck neoplasms around the carotid arteries. MATERIALS AND METHODS:Forty-nine patients (28 male patients and 21 female patients aged 17-79 years; mean, 57.3 years) with head and neck masses and clinical evidence of...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.195.3.7754000

    authors: Yousem DM,Hatabu H,Hurst RW,Seigerman HM,Montone KT,Weinstein GS,Hayden RE,Goldberg AN,Bigelow DC,Kotapka MJ

    更新日期:1995-06-01 00:00:00

  • When does a radiologist's recommendation for follow-up result in high-cost imaging?

    abstract:PURPOSE:To measure the proportion of high-cost imaging generated by a radiologist's recommendation and to identify the imaging findings resulting in follow-up. MATERIALS AND METHODS:This retrospective HIPAA-compliant study had institutional review board approval, with waiver of informed consent. A recommended examinat...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.11111091

    authors: Lee SI,Krishnaraj A,Chatterji M,Dreyer KJ,Thrall JH,Hahn PF

    更新日期:2012-02-01 00:00:00

  • Internal contamination of laboratory personnel by 131I1.

    abstract::Internal contamination by 131I among the personnel in a nuclear medicine laboratory was surveyed from January to July, 1979. Because of the formulation change made by the manufacturer in April to reduce volatility, it was possible to study two different therapeutic solutions of 131I. Internal contamination of personne...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.137.3.7444060

    authors: Nishiyama H,Lukes SJ,Mayfield G,Grossman LW

    更新日期:1980-12-01 00:00:00

  • Variations in the intensive use of head CT for elderly patients with hemorrhagic stroke.

    abstract:PURPOSE:To investigate the variability in head computed tomographic (CT) scanning in patients with hemorrhagic stroke in U.S. hospitals, its association with mortality, and the number of different physicians consulted. MATERIALS AND METHODS:The study was approved by the Committee for the Protection of Human Subjects a...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.14141362

    authors: Bekelis K,Fisher ES,Labropoulos N,Zhou W,Skinner J

    更新日期:2015-04-01 00:00:00

  • First-third ejection fraction at rest compared with exercise radionuclide angiography in assessing patients with coronary artery disease.

    abstract::To compare two methods of evaluating patients with coronary artery disease, the authors assessed the ejection fraction (EF) during the first-third (1/3) of systole by first-pass radionuclide angiography and the EF response to exercise in 22 normal individuals and 40 patients. The 1/3 EF was calculated by averaging 3--...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.136.1.7384500

    authors: Slutsky R,Battler A,Karliner JS,Froelicher V,Ashburn W

    更新日期:1980-07-01 00:00:00

  • Chronic Obstructive Pulmonary Disease: Lobar Analysis with Hyperpolarized 129Xe MR Imaging.

    abstract::Purpose To compare lobar ventilation and apparent diffusion coefficient (ADC) values obtained with hyperpolarized xenon 129 (129Xe) magnetic resonance (MR) imaging to quantitative computed tomography (CT) metrics on a lobar basis and pulmonary function test (PFT) results on a whole-lung basis in patients with chronic ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2016152299

    authors: Matin TN,Rahman N,Nickol AH,Chen M,Xu X,Stewart NJ,Doel T,Grau V,Wild JM,Gleeson FV

    更新日期:2017-03-01 00:00:00

  • Aberrant placement of a Kimray-Greenfield filter in the right atrium: percutaneous retrieval.

    abstract::A Kimray-Greenfield filter was inadvertently placed in the right atrium of a patient with multiple pulmonary emboli. A percutaneous technique with the use of a chest tube and basket catheter was performed to retrieve and remove the filter. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.167.2.3357950

    authors: Tsai FY,Myers TV,Ashraf A,Shah DC

    更新日期:1988-05-01 00:00:00

  • Skeletal development in fetal pig specimens: MR imaging of femur with histologic comparison.

    abstract:PURPOSE:To evaluate the magnetic resonance (MR) imaging features of the developing femur in fetal pig specimens. MATERIALS AND METHODS:MR images of 15 fetal pig femurs, which were categorized into three groups of specimens representing each third of the gestational period, were used to compare increasing femoral lengt...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2332030131

    authors: Connolly SA,Jaramillo D,Hong JK,Shapiro F

    更新日期:2004-11-01 00:00:00

  • Cervical radiculopathy: value of oblique MR imaging.

    abstract::Eighteen patients with cervical radiculopathy were entered into a prospective study to compare the accuracy of surface coil magnetic resonance (MR) imaging with that of metrizamide myelography and computed tomography (CT) with metrizamide. All MR studies included tailored axial and oblique images as well as routine sa...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.163.1.3823440

    authors: Modic MT,Masaryk TJ,Ross JS,Mulopulos GP,Bundschuh CV,Bohlman H

    更新日期:1987-04-01 00:00:00

  • Antefemoral dissecting cysts in rheumatoid arthritis.

    abstract::Five cases of an antefemoral synovial cyst in rheumatoid arthritis were confirmed by arthrography. Communicating with the suprapatellar bursa, these rarely observed cysts may be considered an anterior analogy to dissecting Baker cysts. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/133.2.343

    authors: Seidl G,Scherak O,Hofner W

    更新日期:1979-11-01 00:00:00

  • Pseudolesions at T1-weighted gradient-echo imaging after administration of superparamagnetic iron oxide: comparison with portal perfusion abnormalities at CT during arterial portography.

    abstract:PURPOSE:To compare specific findings at T1-weighted gradient-echo (GRE) magnetic resonance (MR) imaging performed after administration of superparamagnetic iron oxide (SPIO) with nontumorous regional portal perfusion abnormalities seen at computed tomography (CT) during arterial portography (CTAP). MATERIALS AND METHO...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.207.1.9530300

    authors: Scharf J,Hoffmann V,Lehnert T,Anselm H,Richter GM,Kauffmann GW

    更新日期:1998-04-01 00:00:00

  • Fungal sinusitis: diagnosis with CT and MR imaging.

    abstract::Of 293 patients who underwent computed tomography (CT), surgery, and pathologic examination for chronic sinusitis, 25 had a diagnosis of fungal sinusitis at pathologic examination. Of these, 22 had foci of increased attenuation at CT (in four patients the mean representative CT number [Hounsfied unit] was 122.2 HU [SD...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.169.2.3174990

    authors: Zinreich SJ,Kennedy DW,Malat J,Curtin HD,Epstein JI,Huff LC,Kumar AJ,Johns ME,Rosenbaum AE

    更新日期:1988-11-01 00:00:00

  • Bowel and mesenteric injury: evaluation with emergency abdominal US.

    abstract:PURPOSE:To assess emergency ultrasonography (US) for detection of bowel and mesenteric injury from blunt trauma. MATERIALS AND METHODS:For 3 years, prospective data on all patients undergoing emergency US were recorded. Patients with bowel and mesenteric injury were identified, and physical examination, laboratory, co...

    journal_title:Radiology

    pub_type: 临床试验,杂志文章

    doi:10.1148/radiology.211.2.r99ma54399

    authors: Richards JR,McGahan JP,Simpson JL,Tabar P

    更新日期:1999-05-01 00:00:00

  • Biliary duct stones: update on 54 cases after percutaneous transhepatic removal.

    abstract::Percutaneous transhepatic removal of common bile duct stones was performed 54 times in 50 patients with a success rate of 93%. In all patients, a modified Dormia basket was inserted through a percutaneous transhepatic catheter, and the stones or fragments were advanced into the duodenum. All patients had contraindicat...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.170.3.2916070

    authors: Stokes KR,Falchuk KR,Clouse ME

    更新日期:1989-03-01 00:00:00

  • Case 256: Breast Implant-associated Anaplastic Large-Cell Lymphoma.

    abstract::History A 57-year-old woman presented with right breast swelling and enlargement and a palpable mass in the right lower inner breast. There was no history of fever, trauma, skin redness, or nipple discharge. The patient had a history of breast augmentation, with retropectoral silicone implants placed 2.5 years ago. Sc...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2018160440

    authors: Eisenberg AM,Eppelheimer CN,Fulop TA,Abramson LL

    更新日期:2018-08-01 00:00:00

  • Indirect MR arthrography of the shoulder: use of abduction and external rotation to detect full- and partial-thickness tears of the supraspinatus tendon.

    abstract:PURPOSE:To evaluate prospectively the accuracy of indirect magnetic resonance (MR) arthrography for supraspinatus tendon tears during neutral positioning or abduction and external rotation (ABER) and neutral positioning. MATERIALS AND METHODS:Informed consent was obtained in all patients, and the study was approved by...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2393050453

    authors: Herold T,Bachthaler M,Hamer OW,Hente R,Feuerbach S,Fellner C,Strotzer M,Lenhart M,Paetzel C

    更新日期:2006-07-01 00:00:00

  • Hypervascular hepatic metastases: CT evaluation.

    abstract::Recent reports have indicated that non-contrast material-enhanced scans are of less value than urographic contrast material-enhanced studies in the computed tomographic (CT) evaluation of hepatic metastases. The authors retrospectively reviewed the CT scans of 28 patients with hypervascular liver metastases to determi...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.162.1.3024210

    authors: Bressler EL,Alpern MB,Glazer GM,Francis IR,Ensminger WD

    更新日期:1987-01-01 00:00:00

  • Forecasting motor recovery after cervical spinal cord injury: value of MR imaging.

    abstract:PURPOSE:To determine whether magnetic resonance (MR) imaging quantification of cervical spinal cord damage improves the prediction of motor recovery after spinal cord injury. MATERIALS AND METHODS:The extent of cervical spinal cord injury was measured on MR images obtained in 104 patients (aged 17-70 years) within 72 ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.201.3.8939210

    authors: Flanders AE,Spettell CM,Tartaglino LM,Friedman DP,Herbison GJ

    更新日期:1996-12-01 00:00:00

  • Percutaneous transhepatic balloon dilation of portal venous stenosis in patients with living donor liver transplantation.

    abstract:PURPOSE:To retrospectively evaluate the long-term effectiveness of percutaneous transhepatic balloon dilation of portal venous stenosis in patients who have undergone living donor liver transplantation. MATERIALS AND METHODS:Institutional review board approval and informed consent were not required. From June 1996 to ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2353040489

    authors: Shibata T,Itoh K,Kubo T,Maetani Y,Shibata T,Togashi K,Tanaka K

    更新日期:2005-06-01 00:00:00

  • Elastofibroma: chest wall pseudotumor.

    abstract::A 68-year-old man had a painless, nontender lump in the right infrascapular region. An unenhanced computed tomography (CT) scan showed a soft-tissue mass attached to the scapula, causing muscular displacement. A similar, smaller mass was found on the left side. The appearance of the masses on CT scans was suggestive o...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.160.2.3726110

    authors: Berthoty DP,Shulman HS,Miller HA

    更新日期:1986-08-01 00:00:00

  • Primary non-small cell lung cancer: review of frequency, location, and time of recurrence after radiofrequency ablation.

    abstract:PURPOSE:To review the recurrence patterns in patients with primary non-small cell lung cancer (NSCLC) treated with percutaneous image-guided radiofrequency (RF) ablation. MATERIALS AND METHODS:This retrospective review was institutional review board approved and HIPAA compliant. Informed consent was waived. Data from ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.00000090174

    authors: Beland MD,Wasser EJ,Mayo-Smith WW,Dupuy DE

    更新日期:2010-01-01 00:00:00

  • Heterotopic bone formation after hip surgery: prevention with single-dose postoperative hip irradiation.

    abstract::From 1981 to 1986, 23 patients (24 hips) were treated with single-dose irradiation after hip surgery in an attempt to prevent heterotopic bone formation. All patients were at high risk for the development of heterotopic ossification because of the presence of heterotopic bone in either hip secondary to trauma or previ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.168.3.3136510

    authors: Lo TC,Healy WL,Covall DJ,Dotter WE,Pfeifer BA,Torgerson WR,Wasilewski SA

    更新日期:1988-09-01 00:00:00

  • Hemochromatosis of the pituitary gland: MR imaging.

    abstract::Magnetic resonance imaging of the pituitary gland in a patient with secondary hemochromatosis is described. On T1-weighted images, the anterior lobe had almost no signal intensity, and only the high-signal posterior lobe was seen. These findings are compatible with the distribution of iron deposition and clinical symp...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.168.1.3380960

    authors: Fujisawa I,Morikawa M,Nakano Y,Konishi J

    更新日期:1988-07-01 00:00:00

  • Pulmonary circulation: contrast-enhanced 3.0-T MR angiography--initial results.

    abstract:PURPOSE:To prospectively evaluate the technical feasibility of both high-spatial-resolution and time-resolved contrast material-enhanced magnetic resonance (MR) angiography of the pulmonary circulation at 3.0 T. MATERIALS AND METHODS:All examinations were HIPAA compliant. After institutional review board approval and ...

    journal_title:Radiology

    pub_type: 临床试验,杂志文章

    doi:10.1148/radiol.2403051076

    authors: Nael K,Michaely HJ,Kramer U,Lee MH,Goldin J,Laub G,Finn JP

    更新日期:2006-09-01 00:00:00

  • Predicting pathologic response to neoadjuvant chemotherapy in breast cancer by using MR imaging and quantitative 1H MR spectroscopy.

    abstract:PURPOSE:To compare changes in the concentration of choline-containing compounds (tCho) and in tumor size at follow-up after neoadjuvant chemotherapy (NAC) between patients who achieved pathologic complete response (pCR) and those who did not (non-pCR). MATERIALS AND METHODS:This study was approved by the institutional...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2512080553

    authors: Baek HM,Chen JH,Nie K,Yu HJ,Bahri S,Mehta RS,Nalcioglu O,Su MY

    更新日期:2009-06-01 00:00:00

  • False-Positive Measurement at 2-Hydroxyglutarate MR Spectroscopy in Isocitrate Dehydrogenase Wild-Type Glioblastoma: A Multifactorial Analysis.

    abstract::Background Isocitrate dehydrogenase (IDH) mutation has become one of the most important prognostic biomarkers in glioma management. Measurement of 2-hydroxyglutarate (2HG) with MR spectroscopy has shown high pooled sensitivity, although false-positive results with MR spectroscopy have been reported. Purpose To investi...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2019182200

    authors: Suh CH,Kim HS,Paik W,Choi C,Ryu KH,Kim D,Woo DC,Park JE,Jung SC,Choi CG,Kim SJ

    更新日期:2019-06-01 00:00:00

  • Posteroinferior labral cleft at direct CT arthrography of the shoulder by using multidetector CT: is this a normal variant?

    abstract:PURPOSE:To describe a posterior labral cleft at direct computed tomographic (CT) arthrography of the shoulder by using multidetector CT and to compare this finding with a true posterior labral tear. MATERIALS AND METHODS:Institutional ethics review board approval was obtained, and informed consent was waived. One hund...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2533081997

    authors: Lee GY,Choi JA,Oh JH,Choi JY,Hong SH,Kang HS

    更新日期:2009-12-01 00:00:00

  • Transducer selection for pancreatic ultrasound based on skin to pancreas distance in the supine and upright position.

    abstract::In order to match the focal zone of the transducer with the depth of the organ, skin to pancreas distances were measured in 58 patients undergoing ultrasound studies. The measurements showed that a dynamically focused transducer would be most useful. In other cases the results of such measuring would help determine th...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.134.2.7352250

    authors: Kwa A,Bowie JD

    更新日期:1980-02-01 00:00:00