Biliary duct stones: update on 54 cases after percutaneous transhepatic removal.

Abstract:

:Percutaneous transhepatic removal of common bile duct stones was performed 54 times in 50 patients with a success rate of 93%. In all patients, a modified Dormia basket was inserted through a percutaneous transhepatic catheter, and the stones or fragments were advanced into the duodenum. All patients had contraindications to surgery or had undergone unsuccessful attempts at endoscopic retrograde cholangiopancreatography and sphincterotomy. Monooctanoin (25 patients) or methyl tertiary-butyl ether (four patients) was infused to reduce stone size or remove residual debris. The average time for complete stone removal was 8.6 days. Morbidity was 13% and mortality was 4%, results which compare favorably with those of surgery.

journal_name

Radiology

journal_title

Radiology

authors

Stokes KR,Falchuk KR,Clouse ME

doi

10.1148/radiology.170.3.2916070

subject

Has Abstract

pub_date

1989-03-01 00:00:00

pages

999-1001

issue

3 Pt 2

eissn

0033-8419

issn

1527-1315

journal_volume

170

pub_type

杂志文章
  • Case 236: Middle Interhemispheric Variant of Holoprosencephaly.

    abstract::History A 13-year-old girl presented for evaluation and further management of spastic diplegia cerebral palsy. Absence of the corpus callosum was noted at screening prenatal head ultrasonography. She was born at full term via spontaneous vaginal delivery. Physical examination revealed decreased axial muscle tone and i...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2016150503

    authors: Yahyavi-Firouz-Abadi N,Poretti A,Idowu OR,Hoon AH Jr,Huisman TA,Izbudak I

    更新日期:2016-12-01 00:00:00

  • Colorectal carcinoma metastases: detection with In-111-labeled monoclonal antibody CCR 086.

    abstract::A phase I/II clinical trial with indium-111-labeled antimucin murine monoclonal antibody (MoAb) CCR 086 was conducted. Seventeen patients with histologically proved colorectal carcinoma and known metastatic disease underwent external scintigraphy after administration of 5.5 mCi (203.5 MBq) of In-111 CCR 086 at doses o...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.176.1.2353080

    authors: Abdel-Nabi HH,Levine G,Lamki LM,Murray JL,Tauxe WN,Shah AN,Patt YZ,Doerr RJ,Klein HA,Gona J

    更新日期:1990-07-01 00:00:00

  • Complications and hazards with angiographic occlusion balloon catheters.

    abstract::Twenty angiographic procedures involving the superior mesenteric artery (SMA) were performed with balloon occlusion catheters in dogs with chronic liver cirrhosis and portal hypertension. The following complications were found: (a) rapid balloon inflation during angiography due to a leak between the two catheter lumen...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.140.3.7280230

    authors: Burgener FA,Gutierrez OH,Logsdon GA

    更新日期:1981-09-01 00:00:00

  • Shoulder arthrography: comparison of morbidity after use of various contrast media.

    abstract::This prospective study compares immediate and delayed patient discomfort in 177 patients following shoulder arthrography using intraarticular combinations of metrizamide, meglumine/sodium diatrizoate, meglumine diatrizoate, lidocaine, epinephrine, and air. Patients receiving conventional ionic monomeric positive contr...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.154.2.3966120

    authors: Hall FM,Goldberg RP,Wyshak G,Kilcoyne RF

    更新日期:1985-02-01 00:00:00

  • Hyperparathyroidism in high-risk surgical patients: evaluation with double-phase technetium-99m sestamibi imaging.

    abstract:PURPOSE:To evaluate the accuracy of technetium-99m sestamibi as a single agent in the detection and localization of hyperfunctioning parathyroid tissue in patients who underwent prior neck exploration or who otherwise are high surgical risks. MATERIALS AND METHODS:Thirty-nine patients with hyperparathyroidism underwen...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.197.3.7480730

    authors: Lee VS,Wilkinson RH Jr,Leight GS Jr,Coogan AC,Coleman RE

    更新日期:1995-12-01 00:00:00

  • Mammography of a phantom and breast tissue with synchrotron radiation and a linear-array silicon detector.

    abstract::A linear-array, silicon pixel detector, capable of counting single photons, was applied to mammography by using a synchrotron radiation beam. Images were obtained of both a mammographic phantom and a breast-tissue sample. The phantom image was acquired with a mean glandular dose of 0.32 mGy. This detector combined wit...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.208.3.9722850

    authors: Arfelli F,Bonvicini V,Bravin A,Cantatore G,Castelli E,Dalla Palma L,Di Michiel M,Longo R,Olivo A,Pani S,Pontoni D,Poropat P,Prest M,Rashevsky A,Tromba G,Vacchi A

    更新日期:1998-09-01 00:00:00

  • Safety and Efficacy of an Absorbable Filter in the Inferior Vena Cava to Prevent Pulmonary Embolism in Swine.

    abstract::Purpose To evaluate the immediate and long-term safety as well as thrombus-capturing efficacy for 5 weeks after implantation of an absorbable inferior vena cava (IVC) filter in a swine model. Materials and Methods This study was approved by the institutional animal care and use committee. Eleven absorbable IVC filters...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2017161880

    authors: Huang SY,Eggers M,McArthur MJ,Dixon KA,McWatters A,Dria S,Hill LR,Melancon MP,Steele JR,Wallace MJ

    更新日期:2017-12-01 00:00:00

  • Direct chronotropic and dromotropic actions of contrast media: ineffectiveness of atropine in the prevention of bradyarrhythmias and conduction disturbances.

    abstract::Methyl glucamine sodium diatrizoate (Renografin 76) was directly infused into the isolated arteries to the sino-atrial and atrioventricular nodes of anesthetized dogs, causing a dose-related inhibition of sino-atrial nodal automaticity and atrioventricular nodal conductivity; these effects were not attenuated by auton...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/121.1.205

    authors: Higgins CB,Feld GK

    更新日期:1976-10-01 00:00:00

  • Progression of renal artery fibromuscular dysplasia in 42 patients as seen on angiography.

    abstract::Forty-two hypertensive patients with fibromuscular dysplasia who had angiographic evidence of the development of new disease or of the progression of existing disease were studied. Renal arterial disease was classified as medial fibroplasia with aneurysms (12 patients), subadventitial fibroplasia (24 patients), or int...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.139.1.7208940

    authors: Goncharenko V,Gerlock AJ Jr,Shaff MI,Hollifield JW

    更新日期:1981-04-01 00:00:00

  • CT colonography: influence of 3D viewing and polyp candidate features on interpretation with computer-aided detection.

    abstract:PURPOSE:To retrospectively determine if three-dimensional (3D) viewing improves radiologists' accuracy in classifying true-positive (TP) and false-positive (FP) polyp candidates identified with computer-aided detection (CAD) and to determine candidate polyp features that are associated with classification accuracy, wit...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2393050418

    authors: Shi R,Schraedley-Desmond P,Napel S,Olcott EW,Jeffrey RB Jr,Yee J,Zalis ME,Margolis D,Paik DS,Sherbondy AJ,Sundaram P,Beaulieu CF

    更新日期:2006-06-01 00:00:00

  • Is T1ρ Mapping an Alternative to Delayed Gadolinium-enhanced MR Imaging of Cartilage in the Assessment of Sulphated Glycosaminoglycan Content in Human Osteoarthritic Knees? An in Vivo Validation Study.

    abstract:PURPOSE:To determine if T1ρ mapping can be used as an alternative to delayed gadolinium-enhanced magnetic resonance imaging of cartilage (dGEMRIC) in the quantification of cartilage biochemical composition in vivo in human knees with osteoarthritis. MATERIALS AND METHODS:This study was approved by the institutional re...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2015150693

    authors: van Tiel J,Kotek G,Reijman M,Bos PK,Bron EE,Klein S,Nasserinejad K,van Osch GJ,Verhaar JA,Krestin GP,Weinans H,Oei EH

    更新日期:2016-05-01 00:00:00

  • Catheter and material selection for transarterial embolization: technical considerations. II. Materials.

    abstract::In this second part of the report, the authors discuss the advantages and disadvantages of several embolization agents. These include Gelfoam, silicone spheres, polyvinyl alcohol foam (PVA), isobutyl-2-cyanoacrylate (IBCA), silicone fluid mixtures, and tantalum powder. The techniques employed and conditions under whic...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/132.3.631

    authors: Berenstein A,Kricheff II

    更新日期:1979-09-01 00:00:00

  • Liver transplant biopsies with a biopsy gun.

    abstract::The authors evaluated the safety and efficacy of a biopsy gun for performance of image-guided percutaneous biopsy of hepatic allografts in liver transplant recipients. Two hundred fifty-two liver biopsies were performed in 58 transplant recipients over a 27-month period by using this instrument with an 18-gauge needle...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.179.2.2014290

    authors: Chezmar JL,Keith LL,Nelson RC,Plaire JC,Hertzler GL,Bernardino ME

    更新日期:1991-05-01 00:00:00

  • Renal mass biopsy to guide treatment decisions for small incidental renal tumors: a cost-effectiveness analysis.

    abstract:PURPOSE:To evaluate the effectiveness, cost, and cost-effectiveness of using renal mass biopsy to guide treatment decisions for small incidentally detected renal tumors. MATERIALS AND METHODS:A decision-analytic Markov model was developed to estimate life expectancy and lifetime costs for patients with small (< or = 4...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.10092013

    authors: Pandharipande PV,Gervais DA,Hartman RI,Harisinghani MG,Feldman AS,Mueller PR,Gazelle GS

    更新日期:2010-09-01 00:00:00

  • Intracranial lesions: flow-related enhancement on MR images using time-of-flight effects.

    abstract::Many physico-anatomic variables and instrument parameters influence the relative magnetic resonance signal intensity of vascular channels. The interaction of these mechanisms is complex, but their composite effects can be accounted for by two main categories of flow phenomena: time-of-flight effects and spin-phase cha...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.161.3.3786730

    authors: Kucharczyk W,Kelly WM,Davis DO,Norman D,Newton TH

    更新日期:1986-12-01 00:00:00

  • Lymph node metastasis in patients with clinical early-stage cervical cancer: detection with integrated FDG PET/CT.

    abstract:PURPOSE:To prospectively determine the accuracy of combination positron emission tomography-computed tomography (PET/CT) in lymph node staging in patients with early-stage cervical cancer, with histopathologic results as the reference standard. MATERIALS AND METHODS:The study was institutional review board approved, a...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2381041799

    authors: Sironi S,Buda A,Picchio M,Perego P,Moreni R,Pellegrino A,Colombo M,Mangioni C,Messa C,Fazio F

    更新日期:2006-01-01 00:00:00

  • Performance of Screening Breast MRI across Women with Different Elevated Breast Cancer Risk Indications.

    abstract::Background Screening breast MRI is recommended for women with BRCA mutation or a history of chest radiation, but guidelines are equivocal for MRI screening of women with a personal history of breast cancer or high-risk lesion. Purpose To evaluate screening breast MRI performance across women with different elevated br...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2019181136

    authors: Sippo DA,Burk KS,Mercaldo SF,Rutledge GM,Edmonds C,Guan Z,Hughes KS,Lehman CD

    更新日期:2019-07-01 00:00:00

  • Duplex carotid sonography: criteria for stenosis, accuracy, and pitfalls.

    abstract::Both carotid bifurcations were examined in 353 patients over a 20-month interval using a combination of real-time and pulsed Doppler ultrasound (duplex scanning). Angiographic correlation was available in 72 cases. Stenosis of the internal carotid was evaluated using a Doppler input frequency of 5 MHz and a scan angle...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.154.2.3880910

    authors: Jacobs NM,Grant EG,Schellinger D,Byrd MC,Richardson JD,Cohan SL

    更新日期:1985-02-01 00:00:00

  • Human breast cancer in vivo: H-1 and P-31 MR spectroscopy at 1.5 T.

    abstract::To assess the potential of in vivo magnetic resonance (MR) spectroscopy for breast cancer, hydrogen-1 and phosphorus-31 MR spectra of five malignant human breast tumors were compared with those of unaffected breast tissue. The water-to-fat ratio was high in the tumors (average, 2.2) but low in the unaffected tissue (a...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.169.3.2847230

    authors: Sijens PE,Wijrdeman HK,Moerland MA,Bakker CJ,Vermeulen JW,Luyten PR

    更新日期:1988-12-01 00:00:00

  • Germ cell tumor: differentiation of viable tumor, mature teratoma, and necrotic tissue with FDG PET and kinetic modeling.

    abstract:PURPOSE:To evaluate the feasibility of positron emission tomography (PET) with 2-[fluorine-18]-fluoro-2-deoxy-D-glucose (FDG) in patients with germ cell tumor (GCT) to monitor treatment and differentiate residual masses after chemotherapy. MATERIALS AND METHODS:Twenty-six FDG PET studies were performed in 21 patients ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.211.1.r99ap16249

    authors: Sugawara Y,Zasadny KR,Grossman HB,Francis IR,Clarke MF,Wahl RL

    更新日期:1999-04-01 00:00:00

  • Percutaneous cholecystolithotomy: preliminary experience and technical considerations.

    abstract::Surgical cholecystectomy is associated with a high morbidity and mortality in elderly patients with acute calculous cholecystitis and underlying cardiac or pulmonary disease. Currently there are few alternatives for treating these patients. The authors have used percutaneous cholecystolithotomy in 11 such high-risk pa...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.173.2.2798880

    authors: Picus D,Marx MV,Hicks ME,Lang EV,Edmundowicz SA

    更新日期:1989-11-01 00:00:00

  • Lung lesions: correlation between viewing time and detection.

    abstract::The influence of viewing time on the detectability of subtle and obvious lung cancers was studied. Frontal chest radiographs of 40 patients with subtle cancers, 40 patients with obvious cancers, and 40 healthy control subjects were shown to four observers for four different viewing times (0.25 second, 1 second, 4 seco...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.166.2.3336720

    authors: Oestmann JW,Greene R,Kushner DC,Bourgouin PM,Linetsky L,Llewellyn HJ

    更新日期:1988-02-01 00:00:00

  • Electrotransfer at MR imaging: tool for optimization of gene transfer protocols--feasibility study in mice.

    abstract:PURPOSE:To test, by using an electrotransfer protocol for the transfection of skeletal muscle with naked plasmid complementary DNA, whether in vivo magnetic resonance (MR) imaging can help delineate either the spatial extent of the electric field when contrast agent is injected intraperitoneally or the transfection are...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2283020482

    authors: Paturneau-Jouas M,Parzy E,Vidal G,Carlier PG,Wary C,Vilquin JT,de Kerviler E,Schwartz K,Leroy-Willig A

    更新日期:2003-09-01 00:00:00

  • Gallium 68 PSMA-11 PET/MR Imaging in Patients with Intermediate- or High-Risk Prostate Cancer.

    abstract::Purpose To report the results of dual-time-point gallium 68 (68Ga) prostate-specific membrane antigen (PSMA)-11 positron emission tomography (PET)/magnetic resonance (MR) imaging prior to prostatectomy in patients with intermediate- or high-risk cancer. Materials and Methods Thirty-three men who underwent conventional...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2018172232

    authors: Park SY,Zacharias C,Harrison C,Fan RE,Kunder C,Hatami N,Giesel F,Ghanouni P,Daniel B,Loening AM,Sonn GA,Iagaru A

    更新日期:2018-08-01 00:00:00

  • The columnar-lined esophagus--analysis of 26 cases.

    abstract::A review of 26 cases of columnar-lined (Barrett's) esophagus suggests that this lesion is more common than generally appreciated, usually arising consequent to reflux esophagitis. The radiologically detectable lesions frequently do not support the idea that Barrett's esophagus presents only with high esophageal ulcer ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/123.1.1

    authors: Robbins AH,Hermos JA,Schimmel EM,Friedlander DM,Messian RA

    更新日期:1977-04-01 00:00:00

  • Imaging review of the temporal bone: part I. Anatomy and inflammatory and neoplastic processes.

    abstract::From a clinical-radiologic standpoint, there are a limited number of structures and disease entities in the temporal bone with which one must be familiar in order to proficiently interpret a computed tomographic or magnetic resonance imaging study of the temporal bone. It is helpful to examine the region in an organiz...

    journal_title:Radiology

    pub_type: 杂志文章,评审

    doi:10.1148/radiol.13120733

    authors: Juliano AF,Ginat DT,Moonis G

    更新日期:2013-10-01 00:00:00

  • Pulmonary abnormalities and PET data analysis: a retrospective study.

    abstract:PURPOSE:To assess methods of standard uptake ratio (SUR) calculation with 2-deoxy-2-[fluorine-18]fluoro-D-glucose (FDG) positron emission tomography (PET) in indeterminate focal pulmonary abnormalities. MATERIALS AND METHODS:One hundred ninety-seven adult patients with indeterminate pulmonary abnormalities had complet...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.202.2.9015070

    authors: Lowe VJ,Duhaylongsod FG,Patz EF,Delong DM,Hoffman JM,Wolfe WG,Coleman RE

    更新日期:1997-02-01 00:00:00

  • Screening for occlusive vascular disease with intraarterial DSA: preliminary experience with a high flow 4-F catheter.

    abstract::Forty-two patients underwent intraarterial digital subtraction angiography (DSA) of the carotid or renal arteries, utilizing a new 4-F aortic flush catheter; 37 procedures were percutaneous transbrachial, five were percutaneous transfemoral. Image quality was consistently good or excellent. The safety of nonselective ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.153.3.6387800

    authors: Becker GJ,Hicks ME,Holden RW,Edwards MK,Jackson VP,Bendick PJ

    更新日期:1984-12-01 00:00:00

  • Calculation of T2 values versus phase imaging for the distinction between flow and thrombus in MR imaging.

    abstract::In magnetic resonance (MR) imaging the distinction between vascular signal from flowing blood and thrombus of any nature is often difficult. Even though there are qualitative criteria to identify intravascular signal as coming from flowing blood, these can fail, and no definitive statement can be made on the nature of...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.164.2.3602400

    authors: von Schulthess GK,Augustiny N

    更新日期:1987-08-01 00:00:00

  • Coaxial needle technique for lumbar puncture in the morbidly obese patient.

    abstract::The authors describe a method of enhancing the ease of lumbar puncture in the morbidly obese patient. In their experience, the coaxial needle technique shortens fluoroscopic and total procedure times when obtaining cerebrospinal fluid for laboratory analysis or when performing myelography. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.179.3.2028010

    authors: Johnson JC,Deeb ZL

    更新日期:1991-06-01 00:00:00