Abstract:
:Percutaneous transhepatic removal of common bile duct stones was performed 54 times in 50 patients with a success rate of 93%. In all patients, a modified Dormia basket was inserted through a percutaneous transhepatic catheter, and the stones or fragments were advanced into the duodenum. All patients had contraindications to surgery or had undergone unsuccessful attempts at endoscopic retrograde cholangiopancreatography and sphincterotomy. Monooctanoin (25 patients) or methyl tertiary-butyl ether (four patients) was infused to reduce stone size or remove residual debris. The average time for complete stone removal was 8.6 days. Morbidity was 13% and mortality was 4%, results which compare favorably with those of surgery.
journal_name
Radiologyjournal_title
Radiologyauthors
Stokes KR,Falchuk KR,Clouse MEdoi
10.1148/radiology.170.3.2916070subject
Has Abstractpub_date
1989-03-01 00:00:00pages
999-1001issue
3 Pt 2eissn
0033-8419issn
1527-1315journal_volume
170pub_type
杂志文章相关文献
RADIOLOGY文献大全abstract::History A 13-year-old girl presented for evaluation and further management of spastic diplegia cerebral palsy. Absence of the corpus callosum was noted at screening prenatal head ultrasonography. She was born at full term via spontaneous vaginal delivery. Physical examination revealed decreased axial muscle tone and i...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2016150503
更新日期:2016-12-01 00:00:00
abstract::A phase I/II clinical trial with indium-111-labeled antimucin murine monoclonal antibody (MoAb) CCR 086 was conducted. Seventeen patients with histologically proved colorectal carcinoma and known metastatic disease underwent external scintigraphy after administration of 5.5 mCi (203.5 MBq) of In-111 CCR 086 at doses o...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.176.1.2353080
更新日期:1990-07-01 00:00:00
abstract::Twenty angiographic procedures involving the superior mesenteric artery (SMA) were performed with balloon occlusion catheters in dogs with chronic liver cirrhosis and portal hypertension. The following complications were found: (a) rapid balloon inflation during angiography due to a leak between the two catheter lumen...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.140.3.7280230
更新日期:1981-09-01 00:00:00
abstract::This prospective study compares immediate and delayed patient discomfort in 177 patients following shoulder arthrography using intraarticular combinations of metrizamide, meglumine/sodium diatrizoate, meglumine diatrizoate, lidocaine, epinephrine, and air. Patients receiving conventional ionic monomeric positive contr...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.154.2.3966120
更新日期:1985-02-01 00:00:00
abstract:PURPOSE:To evaluate the accuracy of technetium-99m sestamibi as a single agent in the detection and localization of hyperfunctioning parathyroid tissue in patients who underwent prior neck exploration or who otherwise are high surgical risks. MATERIALS AND METHODS:Thirty-nine patients with hyperparathyroidism underwen...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.197.3.7480730
更新日期:1995-12-01 00:00:00
abstract::A linear-array, silicon pixel detector, capable of counting single photons, was applied to mammography by using a synchrotron radiation beam. Images were obtained of both a mammographic phantom and a breast-tissue sample. The phantom image was acquired with a mean glandular dose of 0.32 mGy. This detector combined wit...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.208.3.9722850
更新日期:1998-09-01 00:00:00
abstract::Purpose To evaluate the immediate and long-term safety as well as thrombus-capturing efficacy for 5 weeks after implantation of an absorbable inferior vena cava (IVC) filter in a swine model. Materials and Methods This study was approved by the institutional animal care and use committee. Eleven absorbable IVC filters...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2017161880
更新日期:2017-12-01 00:00:00
abstract::Methyl glucamine sodium diatrizoate (Renografin 76) was directly infused into the isolated arteries to the sino-atrial and atrioventricular nodes of anesthetized dogs, causing a dose-related inhibition of sino-atrial nodal automaticity and atrioventricular nodal conductivity; these effects were not attenuated by auton...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/121.1.205
更新日期:1976-10-01 00:00:00
abstract::Forty-two hypertensive patients with fibromuscular dysplasia who had angiographic evidence of the development of new disease or of the progression of existing disease were studied. Renal arterial disease was classified as medial fibroplasia with aneurysms (12 patients), subadventitial fibroplasia (24 patients), or int...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.139.1.7208940
更新日期:1981-04-01 00:00:00
abstract:PURPOSE:To retrospectively determine if three-dimensional (3D) viewing improves radiologists' accuracy in classifying true-positive (TP) and false-positive (FP) polyp candidates identified with computer-aided detection (CAD) and to determine candidate polyp features that are associated with classification accuracy, wit...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2393050418
更新日期:2006-06-01 00:00:00
abstract:PURPOSE:To determine if T1ρ mapping can be used as an alternative to delayed gadolinium-enhanced magnetic resonance imaging of cartilage (dGEMRIC) in the quantification of cartilage biochemical composition in vivo in human knees with osteoarthritis. MATERIALS AND METHODS:This study was approved by the institutional re...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2015150693
更新日期:2016-05-01 00:00:00
abstract::In this second part of the report, the authors discuss the advantages and disadvantages of several embolization agents. These include Gelfoam, silicone spheres, polyvinyl alcohol foam (PVA), isobutyl-2-cyanoacrylate (IBCA), silicone fluid mixtures, and tantalum powder. The techniques employed and conditions under whic...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/132.3.631
更新日期:1979-09-01 00:00:00
abstract::The authors evaluated the safety and efficacy of a biopsy gun for performance of image-guided percutaneous biopsy of hepatic allografts in liver transplant recipients. Two hundred fifty-two liver biopsies were performed in 58 transplant recipients over a 27-month period by using this instrument with an 18-gauge needle...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.179.2.2014290
更新日期:1991-05-01 00:00:00
abstract:PURPOSE:To evaluate the effectiveness, cost, and cost-effectiveness of using renal mass biopsy to guide treatment decisions for small incidentally detected renal tumors. MATERIALS AND METHODS:A decision-analytic Markov model was developed to estimate life expectancy and lifetime costs for patients with small (< or = 4...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.10092013
更新日期:2010-09-01 00:00:00
abstract::Many physico-anatomic variables and instrument parameters influence the relative magnetic resonance signal intensity of vascular channels. The interaction of these mechanisms is complex, but their composite effects can be accounted for by two main categories of flow phenomena: time-of-flight effects and spin-phase cha...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.161.3.3786730
更新日期:1986-12-01 00:00:00
abstract:PURPOSE:To prospectively determine the accuracy of combination positron emission tomography-computed tomography (PET/CT) in lymph node staging in patients with early-stage cervical cancer, with histopathologic results as the reference standard. MATERIALS AND METHODS:The study was institutional review board approved, a...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2381041799
更新日期:2006-01-01 00:00:00
abstract::Background Screening breast MRI is recommended for women with BRCA mutation or a history of chest radiation, but guidelines are equivocal for MRI screening of women with a personal history of breast cancer or high-risk lesion. Purpose To evaluate screening breast MRI performance across women with different elevated br...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2019181136
更新日期:2019-07-01 00:00:00
abstract::Both carotid bifurcations were examined in 353 patients over a 20-month interval using a combination of real-time and pulsed Doppler ultrasound (duplex scanning). Angiographic correlation was available in 72 cases. Stenosis of the internal carotid was evaluated using a Doppler input frequency of 5 MHz and a scan angle...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.154.2.3880910
更新日期:1985-02-01 00:00:00
abstract::To assess the potential of in vivo magnetic resonance (MR) spectroscopy for breast cancer, hydrogen-1 and phosphorus-31 MR spectra of five malignant human breast tumors were compared with those of unaffected breast tissue. The water-to-fat ratio was high in the tumors (average, 2.2) but low in the unaffected tissue (a...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.169.3.2847230
更新日期:1988-12-01 00:00:00
abstract:PURPOSE:To evaluate the feasibility of positron emission tomography (PET) with 2-[fluorine-18]-fluoro-2-deoxy-D-glucose (FDG) in patients with germ cell tumor (GCT) to monitor treatment and differentiate residual masses after chemotherapy. MATERIALS AND METHODS:Twenty-six FDG PET studies were performed in 21 patients ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.211.1.r99ap16249
更新日期:1999-04-01 00:00:00
abstract::Surgical cholecystectomy is associated with a high morbidity and mortality in elderly patients with acute calculous cholecystitis and underlying cardiac or pulmonary disease. Currently there are few alternatives for treating these patients. The authors have used percutaneous cholecystolithotomy in 11 such high-risk pa...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.173.2.2798880
更新日期:1989-11-01 00:00:00
abstract::The influence of viewing time on the detectability of subtle and obvious lung cancers was studied. Frontal chest radiographs of 40 patients with subtle cancers, 40 patients with obvious cancers, and 40 healthy control subjects were shown to four observers for four different viewing times (0.25 second, 1 second, 4 seco...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.166.2.3336720
更新日期:1988-02-01 00:00:00
abstract:PURPOSE:To test, by using an electrotransfer protocol for the transfection of skeletal muscle with naked plasmid complementary DNA, whether in vivo magnetic resonance (MR) imaging can help delineate either the spatial extent of the electric field when contrast agent is injected intraperitoneally or the transfection are...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2283020482
更新日期:2003-09-01 00:00:00
abstract::Purpose To report the results of dual-time-point gallium 68 (68Ga) prostate-specific membrane antigen (PSMA)-11 positron emission tomography (PET)/magnetic resonance (MR) imaging prior to prostatectomy in patients with intermediate- or high-risk cancer. Materials and Methods Thirty-three men who underwent conventional...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2018172232
更新日期:2018-08-01 00:00:00
abstract::A review of 26 cases of columnar-lined (Barrett's) esophagus suggests that this lesion is more common than generally appreciated, usually arising consequent to reflux esophagitis. The radiologically detectable lesions frequently do not support the idea that Barrett's esophagus presents only with high esophageal ulcer ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/123.1.1
更新日期:1977-04-01 00:00:00
abstract::From a clinical-radiologic standpoint, there are a limited number of structures and disease entities in the temporal bone with which one must be familiar in order to proficiently interpret a computed tomographic or magnetic resonance imaging study of the temporal bone. It is helpful to examine the region in an organiz...
journal_title:Radiology
pub_type: 杂志文章,评审
doi:10.1148/radiol.13120733
更新日期:2013-10-01 00:00:00
abstract:PURPOSE:To assess methods of standard uptake ratio (SUR) calculation with 2-deoxy-2-[fluorine-18]fluoro-D-glucose (FDG) positron emission tomography (PET) in indeterminate focal pulmonary abnormalities. MATERIALS AND METHODS:One hundred ninety-seven adult patients with indeterminate pulmonary abnormalities had complet...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.202.2.9015070
更新日期:1997-02-01 00:00:00
abstract::Forty-two patients underwent intraarterial digital subtraction angiography (DSA) of the carotid or renal arteries, utilizing a new 4-F aortic flush catheter; 37 procedures were percutaneous transbrachial, five were percutaneous transfemoral. Image quality was consistently good or excellent. The safety of nonselective ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.153.3.6387800
更新日期:1984-12-01 00:00:00
abstract::In magnetic resonance (MR) imaging the distinction between vascular signal from flowing blood and thrombus of any nature is often difficult. Even though there are qualitative criteria to identify intravascular signal as coming from flowing blood, these can fail, and no definitive statement can be made on the nature of...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.164.2.3602400
更新日期:1987-08-01 00:00:00
abstract::The authors describe a method of enhancing the ease of lumbar puncture in the morbidly obese patient. In their experience, the coaxial needle technique shortens fluoroscopic and total procedure times when obtaining cerebrospinal fluid for laboratory analysis or when performing myelography. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.179.3.2028010
更新日期:1991-06-01 00:00:00