Dual-core steered non-rigid registration for multi-modal images via bi-directional image synthesis.

Abstract:

:In prostate cancer radiotherapy, computed tomography (CT) is widely used for dose planning purposes. However, because CT has low soft tissue contrast, it makes manual contouring difficult for major pelvic organs. In contrast, magnetic resonance imaging (MRI) provides high soft tissue contrast, which makes it ideal for accurate manual contouring. Therefore, the contouring accuracy on CT can be significantly improved if the contours in MRI can be mapped to CT domain by registering MRI with CT of the same subject, which would eventually lead to high treatment efficacy. In this paper, we propose a bi-directional image synthesis based approach for MRI-to-CT pelvic image registration. First, we use patch-wise random forest with auto-context model to learn the appearance mapping from CT to MRI domain, and then vice versa. Consequently, we can synthesize a pseudo-MRI whose anatomical structures are exactly same with CT but with MRI-like appearance, and a pseudo-CT as well. Then, our MRI-to-CT registration can be steered in a dual manner, by simultaneously estimating two deformation pathways: 1) one from the pseudo-CT to the actual CT and 2) another from actual MRI to the pseudo-MRI. Next, a dual-core deformation fusion framework is developed to iteratively and effectively combine these two registration pathways by using complementary information from both modalities. Experiments on a dataset with real pelvic CT and MRI have shown improved registration performance of the proposed method by comparing it to the conventional registration methods, thus indicating its high potential of translation to the routine radiation therapy.

journal_name

Med Image Anal

journal_title

Medical image analysis

authors

Cao X,Yang J,Gao Y,Guo Y,Wu G,Shen D

doi

10.1016/j.media.2017.05.004

subject

Has Abstract

pub_date

2017-10-01 00:00:00

pages

18-31

eissn

1361-8415

issn

1361-8423

pii

S1361-8415(17)30075-0

journal_volume

41

pub_type

杂志文章
  • Automated voxel-based 3D cortical thickness measurement in a combined Lagrangian-Eulerian PDE approach using partial volume maps.

    abstract::Accurate cortical thickness estimation is important for the study of many neurodegenerative diseases. Many approaches have been previously proposed, which can be broadly categorised as mesh-based and voxel-based. While the mesh-based approaches can potentially achieve subvoxel resolution, they usually lack the computa...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2009.07.003

    authors: Acosta O,Bourgeat P,Zuluaga MA,Fripp J,Salvado O,Ourselin S,Alzheimer's Disease Neuroimaging Initiative.

    更新日期:2009-10-01 00:00:00

  • BrainSuite: an automated cortical surface identification tool.

    abstract::We describe a new magnetic resonance (MR) image analysis tool that produces cortical surface representations with spherical topology from MR images of the human brain. The tool provides a sequence of low-level operations in a single package that can produce accurate brain segmentations in clinical time. The tools incl...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/s1361-8415(02)00054-3

    authors: Shattuck DW,Leahy RM

    更新日期:2002-06-01 00:00:00

  • Cardiac function estimation from MRI using a heart model and data assimilation: advances and difficulties.

    abstract::In this paper, we present a framework to estimate local ventricular myocardium contractility using clinical MRI, a heart model and data assimilation. First, we build a generic anatomical model of the ventricles including muscle fibre orientations and anatomical subdivisions. Then, this model is deformed to fit a clini...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2006.04.002

    authors: Sermesant M,Moireau P,Camara O,Sainte-Marie J,Andriantsimiavona R,Cimrman R,Hill DL,Chapelle D,Razavi R

    更新日期:2006-08-01 00:00:00

  • A review of machine learning methods for retinal blood vessel segmentation and artery/vein classification.

    abstract::The eye affords a unique opportunity to inspect a rich part of the human microvasculature non-invasively via retinal imaging. Retinal blood vessel segmentation and classification are prime steps for the diagnosis and risk assessment of microvascular and systemic diseases. A high volume of techniques based on deep lear...

    journal_title:Medical image analysis

    pub_type: 杂志文章,评审

    doi:10.1016/j.media.2020.101905

    authors: Mookiah MRK,Hogg S,MacGillivray TJ,Prathiba V,Pradeepa R,Mohan V,Anjana RM,Doney AS,Palmer CNA,Trucco E

    更新日期:2021-02-01 00:00:00

  • Automated comprehensive Adolescent Idiopathic Scoliosis assessment using MVC-Net.

    abstract::Automated quantitative estimation of spinal curvature is an important task for the ongoing evaluation and treatment planning of Adolescent Idiopathic Scoliosis (AIS). It solves the widely accepted disadvantage of manual Cobb angle measurement (time-consuming and unreliable) which is currently the gold standard for AIS...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2018.05.005

    authors: Wu H,Bailey C,Rasoulinejad P,Li S

    更新日期:2018-08-01 00:00:00

  • Dynamically constructed network with error correction for accurate ventricle volume estimation.

    abstract::Automated ventricle volume estimation (AVVE) on cardiac magnetic resonance (CMR) images is very important for clinical cardiac disease diagnosis. However, current AVVE methods ignore the error correction for the estimated volume. This results in clinically intolerable ventricle volume estimation error and further lead...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2020.101723

    authors: Luo G,Wang W,Tam C,Wang K,Cao S,Zhang H,Chen B,Li S

    更新日期:2020-08-01 00:00:00

  • Continuous diffusion signal, EAP and ODF estimation via Compressive Sensing in diffusion MRI.

    abstract::In this paper, we exploit the ability of Compressed Sensing (CS) to recover the whole 3D Diffusion MRI (dMRI) signal from a limited number of samples while efficiently recovering important diffusion features such as the Ensemble Average Propagator (EAP) and the Orientation Distribution Function (ODF). Some attempts to...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2013.02.010

    authors: Merlet SL,Deriche R

    更新日期:2013-07-01 00:00:00

  • Towards model-based analysis of cardiac MR tagging data: relation between left ventricular shear strain and myofiber orientation.

    abstract::Many cardiac pathologies are reflected in abnormal myocardial deformation, accessible through magnetic resonance tagging (MRT). Interpretation of the MRT data is difficult, since the relation between pathology and deformation is not straightforward. Mathematical models of cardiac mechanics could be used to translate m...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2006.04.001

    authors: Ubbink SW,Bovendeerd PH,Delhaas T,Arts T,van de Vosse FN

    更新日期:2006-08-01 00:00:00

  • Local spatio-temporal encoding of raw perfusion MRI for the prediction of final lesion in stroke.

    abstract::We address the medical image analysis issue of predicting the final lesion in stroke from early perfusion magnetic resonance imaging. The classical processing approach for the dynamical perfusion images consists in a temporal deconvolution to improve the temporal signals associated with each voxel before performing pr...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2018.08.008

    authors: Giacalone M,Rasti P,Debs N,Frindel C,Cho TH,Grenier E,Rousseau D

    更新日期:2018-12-01 00:00:00

  • Comparison of atlas-based techniques for whole-body bone segmentation.

    abstract::We evaluate the accuracy of whole-body bone extraction from whole-body MR images using a number of atlas-based segmentation methods. The motivation behind this work is to find the most promising approach for the purpose of MRI-guided derivation of PET attenuation maps in whole-body PET/MRI. To this end, a variety of a...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2016.11.003

    authors: Arabi H,Zaidi H

    更新日期:2017-02-01 00:00:00

  • Rubik's Cube+: A self-supervised feature learning framework for 3D medical image analysis.

    abstract::Due to the development of deep learning, an increasing number of research works have been proposed to establish automated analysis systems for 3D volumetric medical data to improve the quality of patient care. However, it is challenging to obtain a large number of annotated 3D medical data needed to train a neural net...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2020.101746

    authors: Zhu J,Li Y,Hu Y,Ma K,Zhou SK,Zheng Y

    更新日期:2020-08-01 00:00:00

  • Dynamic MRI reconstruction with end-to-end motion-guided network.

    abstract::Temporal correlation in dynamic magnetic resonance imaging (MRI), such as cardiac MRI, is informative and important to understand motion mechanisms of body regions. Modeling such information into the MRI reconstruction process produces temporally coherent image sequence and reduces imaging artifacts and blurring. Howe...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2020.101901

    authors: Huang Q,Xian Y,Yang D,Qu H,Yi J,Wu P,Metaxas DN

    更新日期:2021-02-01 00:00:00

  • Automatic segmentation of 3D micro-CT coronary vascular images.

    abstract::Although there are many algorithms available in the literature aimed at segmentation and model reconstruction of 3D angiographic images, many are focused on characterizing only a part of the vascular network. This study is motivated by the recent emerging prospects of whole-organ simulations in coronary hemodynamics, ...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2007.06.012

    authors: Lee J,Beighley P,Ritman E,Smith N

    更新日期:2007-12-01 00:00:00

  • Intensity non-uniformity correction in MRI: existing methods and their validation.

    abstract::Magnetic resonance imaging is a popular and powerful non-invasive imaging technique. Automated analysis has become mandatory to efficiently cope with the large amount of data generated using this modality. However, several artifacts, such as intensity non-uniformity, can degrade the quality of acquired data. Intensity...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2005.09.004

    authors: Belaroussi B,Milles J,Carme S,Zhu YM,Benoit-Cattin H

    更新日期:2006-04-01 00:00:00

  • An information theoretic approach for non-rigid image registration using voxel class probabilities.

    abstract::We propose two information theoretic similarity measures that allow to incorporate tissue class information in non-rigid image registration. The first measure assumes that tissue class probabilities have been assigned to each of the images to be registered by prior segmentation of both of them. One image is then non-r...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2005.03.004

    authors: D'Agostino E,Maes F,Vandermeulen D,Suetens P

    更新日期:2006-06-01 00:00:00

  • CT male pelvic organ segmentation using fully convolutional networks with boundary sensitive representation.

    abstract::Accurate segmentation of the prostate and organs at risk (e.g., bladder and rectum) in CT images is a crucial step for radiation therapy in the treatment of prostate cancer. However, it is a very challenging task due to unclear boundaries, large intra- and inter-patient shape variability, and uncertain existence of bo...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2019.03.003

    authors: Wang S,He K,Nie D,Zhou S,Gao Y,Shen D

    更新日期:2019-05-01 00:00:00

  • Symmetric positive semi-definite Cartesian Tensor fiber orientation distributions (CT-FOD).

    abstract::A novel method for estimating a field of fiber orientation distribution (FOD) based on signal de-convolution from a given set of diffusion weighted magnetic resonance (DW-MR) images is presented. We model the FOD by higher order Cartesian tensor basis using a parametrization that explicitly enforces the positive semi-...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2012.07.002

    authors: Weldeselassie YT,Barmpoutis A,Atkins MS

    更新日期:2012-08-01 00:00:00

  • Automated localization of breast cancer in DCE-MRI.

    abstract::Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is increasingly being used for the detection and diagnosis of breast cancer. Compared to mammography, DCE-MRI provides higher sensitivity, however its specificity is variable. Moreover, DCE-MRI data analysis is time consuming and depends on reader expertis...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2014.12.001

    authors: Gubern-Mérida A,Martí R,Melendez J,Hauth JL,Mann RM,Karssemeijer N,Platel B

    更新日期:2015-02-01 00:00:00

  • A procedure to average 3D anatomical structures.

    abstract::Creating a feature-preserving average of three dimensional anatomical surfaces extracted from volume image data is a complex task. Unlike individual images, averages present right-left symmetry and smooth surfaces which give insight into typical proportions. Averaging multiple biological surface images requires carefu...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/s1361-8415(00)00031-1

    authors: Subramanya K,Dean D

    更新日期:2000-12-01 00:00:00

  • A comprehensive study of stent visualization enhancement in X-ray images by image processing means.

    abstract::In this work we propose a comprehensive study of Digital Stent Enhancement (DSE), from the analysis of the requirements to the validation of the proposed solution. First, we derive the stent visualization requirements in the context of the clinical application and workflow. Then, we propose a DSE algorithm combining a...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2011.03.002

    authors: Bismuth V,Vaillant R,Funck F,Guillard N,Najman L

    更新日期:2011-08-01 00:00:00

  • Objective and expert-independent validation of retinal image registration algorithms by a projective imaging distortion model.

    abstract::Fundus camera imaging of the retina is widely used to diagnose and manage ophthalmologic disorders including diabetic retinopathy, glaucoma, and age-related macular degeneration. Retinal images typically have a limited field of view, and multiple images can be joined together using an image registration technique to f...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2010.04.001

    authors: Lee S,Reinhardt JM,Cattin PC,Abràmoff MD

    更新日期:2010-08-01 00:00:00

  • Coupled parametric model for estimation of visual field tests based on OCT macular thickness maps, and vice versa, in glaucoma care.

    abstract::The current standard of care for glaucoma patients consists of functional assessment of vision via visual field (VF) testing, which is sensitive but subjective, time-consuming, and often unreliable. A new imaging technology, Fourier domain optical coherence tomography (OCT), is being introduced to assess the structura...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2011.05.012

    authors: Tsai A,Caprioli J,Shen LQ

    更新日期:2012-01-01 00:00:00

  • Equilibrated warping: Finite element image registration with finite strain equilibrium gap regularization.

    abstract::In this paper, we propose a novel continuum finite strain formulation of the equilibrium gap regularization for image registration. The equilibrium gap regularization essentially penalizes any deviation from the solution of a hyperelastic body in equilibrium with arbitrary loads prescribed at the boundary. It thus rep...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2018.07.007

    authors: Genet M,Stoeck CT,von Deuster C,Lee LC,Kozerke S

    更新日期:2018-12-01 00:00:00

  • Integrating segmentation methods from the Insight Toolkit into a visualization application.

    abstract::The Insight Toolkit (ITK) initiative from the National Library of Medicine has provided a suite of state-of-the-art segmentation and registration algorithms ideally suited to volume visualization and analysis. A volume visualization application that effectively utilizes these algorithms provides many benefits: it allo...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2005.04.009

    authors: Martin K,Ibáñez L,Avila L,Barré S,Kaspersen JH

    更新日期:2005-12-01 00:00:00

  • Attentive neural cell instance segmentation.

    abstract::Neural cell instance segmentation, which aims at joint detection and segmentation of every neural cell in a microscopic image, is essential to many neuroscience applications. The challenge of this task involves cell adhesion, cell distortion, unclear cell contours, low-contrast cell protrusion structures, and backgrou...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2019.05.004

    authors: Yi J,Wu P,Jiang M,Huang Q,Hoeppner DJ,Metaxas DN

    更新日期:2019-07-01 00:00:00

  • Three-dimensional multi-scale line filter for segmentation and visualization of curvilinear structures in medical images.

    abstract::This paper describes a method for the enhancement of curvilinear structures such as vessels and bronchi in three-dimensional (3-D) medical images. A 3-D line enhancement filter is developed with the aim of discriminating line structures from other structures and recovering line structures of various widths. The 3-D li...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/s1361-8415(98)80009-1

    authors: Sato Y,Nakajima S,Shiraga N,Atsumi H,Yoshida S,Koller T,Gerig G,Kikinis R

    更新日期:1998-06-01 00:00:00

  • Clavicle segmentation in chest radiographs.

    abstract::Automated delineation of anatomical structures in chest radiographs is difficult due to superimposition of multiple structures. In this work an automated technique to segment the clavicles in posterior-anterior chest radiographs is presented in which three methods are combined. Pixel classification is applied in two s...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2012.06.009

    authors: Hogeweg L,Sánchez CI,de Jong PA,Maduskar P,van Ginneken B

    更新日期:2012-12-01 00:00:00

  • Automated preoperative planning of femoral stem in total hip arthroplasty from 3D CT data: atlas-based approach and comparative study.

    abstract::Atlas-based methods for automated preoperative planning of the femoral stem implant in total hip arthroplasty are described. Statistical atlases are constructed from a number of past preoperative plans prepared by experienced surgeons in order to represent the surgeon's expertise of the planning. Two types of atlases ...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2011.10.005

    authors: Otomaru I,Nakamoto M,Kagiyama Y,Takao M,Sugano N,Tomiyama N,Tada Y,Sato Y

    更新日期:2012-02-01 00:00:00

  • Recovering from missing data in population imaging - Cardiac MR image imputation via conditional generative adversarial nets.

    abstract::Accurate ventricular volume measurements are the primary indicators of normal/abnor- mal cardiac function and are dependent on the Cardiac Magnetic Resonance (CMR) volumes being complete. However, missing or unusable slices owing to the presence of image artefacts such as respiratory or motion ghosting, aliasing, ring...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2020.101812

    authors: Xia Y,Zhang L,Ravikumar N,Attar R,Piechnik SK,Neubauer S,Petersen SE,Frangi AF

    更新日期:2021-01-01 00:00:00

  • Automated size-specific dose estimates using deep learning image processing.

    abstract::An automated vendor-independent system for dose monitoring in computed tomography (CT) medical examinations involving ionizing radiation is presented in this paper. The system provides precise size-specific dose estimates (SSDE) following the American Association of Physicists in Medicine regulations. Our dose managem...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2020.101898

    authors: Juszczyk J,Badura P,Czajkowska J,Wijata A,Andrzejewski J,Bozek P,Smolinski M,Biesok M,Sage A,Rudzki M,Wieclawek W

    更新日期:2021-02-01 00:00:00