Involuntary eye motion correction in retinal optical coherence tomography: Hardware or software solution?

Abstract:

:In this paper, we review state-of-the-art techniques to correct eye motion artifacts in Optical Coherence Tomography (OCT) imaging. The methods for eye motion artifact reduction can be categorized into two major classes: (1) hardware-based techniques and (2) software-based techniques. In the first class, additional hardware is mounted onto the OCT scanner to gather information about the eye motion patterns during OCT data acquisition. This information is later processed and applied to the OCT data for creating an anatomically correct representation of the retina, either in an offline or online manner. In software based techniques, the motion patterns are approximated either by comparing the acquired data to a reference image, or by considering some prior assumptions about the nature of the eye motion. Careful investigations done on the most common methods in the field provides invaluable insight regarding future directions of the research in this area. The challenge in hardware-based techniques lies in the implementation aspects of particular devices. However, the results of these techniques are superior to those obtained from software-based techniques because they are capable of capturing secondary data related to eye motion during OCT acquisition. Software-based techniques on the other hand, achieve moderate success and their performance is highly dependent on the quality of the OCT data in terms of the amount of motion artifacts contained in them. However, they are still relevant to the field since they are the sole class of techniques with the ability to be applied to legacy data acquired using systems that do not have extra hardware to track eye motion.

journal_name

Med Image Anal

journal_title

Medical image analysis

authors

Baghaie A,Yu Z,D'Souza RM

doi

10.1016/j.media.2017.02.002

subject

Has Abstract

pub_date

2017-04-01 00:00:00

pages

129-145

eissn

1361-8415

issn

1361-8423

pii

S1361-8415(17)30021-X

journal_volume

37

pub_type

杂志文章,评审
  • PCA-based groupwise image registration for quantitative MRI.

    abstract::Quantitative magnetic resonance imaging (qMRI) is a technique for estimating quantitative tissue properties, such as the T1 and T2 relaxation times, apparent diffusion coefficient (ADC), and various perfusion measures. This estimation is achieved by acquiring multiple images with different acquisition parameters (or a...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2015.12.004

    authors: Huizinga W,Poot DH,Guyader JM,Klaassen R,Coolen BF,van Kranenburg M,van Geuns RJ,Uitterdijk A,Polfliet M,Vandemeulebroucke J,Leemans A,Niessen WJ,Klein S

    更新日期:2016-04-01 00:00:00

  • Abdominal multi-organ segmentation with organ-attention networks and statistical fusion.

    abstract::Accurate and robust segmentation of abdominal organs on CT is essential for many clinical applications such as computer-aided diagnosis and computer-aided surgery. But this task is challenging due to the weak boundaries of organs, the complexity of the background, and the variable sizes of different organs. To address...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2019.04.005

    authors: Wang Y,Zhou Y,Shen W,Park S,Fishman EK,Yuille AL

    更新日期:2019-07-01 00:00:00

  • Symmetric positive semi-definite Cartesian Tensor fiber orientation distributions (CT-FOD).

    abstract::A novel method for estimating a field of fiber orientation distribution (FOD) based on signal de-convolution from a given set of diffusion weighted magnetic resonance (DW-MR) images is presented. We model the FOD by higher order Cartesian tensor basis using a parametrization that explicitly enforces the positive semi-...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2012.07.002

    authors: Weldeselassie YT,Barmpoutis A,Atkins MS

    更新日期:2012-08-01 00:00:00

  • Group-level cortical surface parcellation with sulcal pits labeling.

    abstract::Sulcal pits are the points of maximal depth within the folds of the cortical surface. These shape descriptors give a unique opportunity to access to a rich, fine-scale representation of the geometry and the developmental milestones of the cortical surface. However, using sulcal pits analysis at group level requires ne...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2020.101749

    authors: Kaltenmark I,Deruelle C,Brun L,Lefèvre J,Coulon O,Auzias G

    更新日期:2020-12-01 00:00:00

  • A spatiotemporal statistical atlas of motion for the quantification of abnormal myocardial tissue velocities.

    abstract::In this paper, we present a new method for the automatic comparison of myocardial motion patterns and the characterization of their degree of abnormality, based on a statistical atlas of motion built from a reference healthy population. Our main contribution is the computation of atlas-based indexes that quantify the ...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2010.12.006

    authors: Duchateau N,De Craene M,Piella G,Silva E,Doltra A,Sitges M,Bijnens BH,Frangi AF

    更新日期:2011-06-01 00:00:00

  • Ω-Net (Omega-Net): Fully automatic, multi-view cardiac MR detection, orientation, and segmentation with deep neural networks.

    abstract::Pixelwise segmentation of the left ventricular (LV) myocardium and the four cardiac chambers in 2-D steady state free precession (SSFP) cine sequences is an essential preprocessing step for a wide range of analyses. Variability in contrast, appearance, orientation, and placement of the heart between patients, clinical...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2018.05.008

    authors: Vigneault DM,Xie W,Ho CY,Bluemke DA,Noble JA

    更新日期:2018-08-01 00:00:00

  • Local spatio-temporal encoding of raw perfusion MRI for the prediction of final lesion in stroke.

    abstract::We address the medical image analysis issue of predicting the final lesion in stroke from early perfusion magnetic resonance imaging. The classical processing approach for the dynamical perfusion images consists in a temporal deconvolution to improve the temporal signals associated with each voxel before performing pr...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2018.08.008

    authors: Giacalone M,Rasti P,Debs N,Frindel C,Cho TH,Grenier E,Rousseau D

    更新日期:2018-12-01 00:00:00

  • A deep network for tissue microstructure estimation using modified LSTM units.

    abstract::Diffusion magnetic resonance imaging (dMRI) offers a unique tool for noninvasively assessing tissue microstructure. However, accurate estimation of tissue microstructure described by complicated signal models can be challenging when a reduced number of diffusion gradients are used. Deep learning based microstructure e...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2019.04.006

    authors: Ye C,Li X,Chen J

    更新日期:2019-07-01 00:00:00

  • Regularized siamese neural network for unsupervised outlier detection on brain multiparametric magnetic resonance imaging: Application to epilepsy lesion screening.

    abstract::In this study, we propose a novel anomaly detection model targeting subtle brain lesions in multiparametric MRI. To compensate for the lack of annotated data adequately sampling the heterogeneity of such pathologies, we cast this problem as an outlier detection problem and introduce a novel configuration of unsupervis...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2019.101618

    authors: Alaverdyan Z,Jung J,Bouet R,Lartizien C

    更新日期:2020-02-01 00:00:00

  • Probe trajectory interpolation for 3D reconstruction of freehand ultrasound.

    abstract::Three-dimensional (3D) freehand ultrasound uses the acquisition of non-parallel B-scans localized in 3D by a tracking system (optic, mechanical or magnetic). Using the positions of the irregularly spaced B-scans, a regular 3D lattice volume can be reconstructed, to which conventional 3D computer vision algorithms (reg...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2007.05.002

    authors: Coupé P,Hellier P,Morandi X,Barillot C

    更新日期:2007-12-01 00:00:00

  • Piecewise-diffeomorphic image registration: application to the motion estimation between 3D CT lung images with sliding conditions.

    abstract::In this paper, we propose a new strategy for modelling sliding conditions when registering 3D images in a piecewise-diffeomorphic framework. More specifically, our main contribution is the development of a mathematical formalism to perform Large Deformation Diffeomorphic Metric Mapping registration with sliding condit...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2012.10.001

    authors: Risser L,Vialard FX,Baluwala HY,Schnabel JA

    更新日期:2013-02-01 00:00:00

  • CT male pelvic organ segmentation using fully convolutional networks with boundary sensitive representation.

    abstract::Accurate segmentation of the prostate and organs at risk (e.g., bladder and rectum) in CT images is a crucial step for radiation therapy in the treatment of prostate cancer. However, it is a very challenging task due to unclear boundaries, large intra- and inter-patient shape variability, and uncertain existence of bo...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2019.03.003

    authors: Wang S,He K,Nie D,Zhou S,Gao Y,Shen D

    更新日期:2019-05-01 00:00:00

  • Automated comprehensive Adolescent Idiopathic Scoliosis assessment using MVC-Net.

    abstract::Automated quantitative estimation of spinal curvature is an important task for the ongoing evaluation and treatment planning of Adolescent Idiopathic Scoliosis (AIS). It solves the widely accepted disadvantage of manual Cobb angle measurement (time-consuming and unreliable) which is currently the gold standard for AIS...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2018.05.005

    authors: Wu H,Bailey C,Rasoulinejad P,Li S

    更新日期:2018-08-01 00:00:00

  • Exudate detection in color retinal images for mass screening of diabetic retinopathy.

    abstract::The automatic detection of exudates in color eye fundus images is an important task in applications such as diabetic retinopathy screening. The presented work has been undertaken in the framework of the TeleOphta project, whose main objective is to automatically detect normal exams in a tele-ophthalmology network, thu...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2014.05.004

    authors: Zhang X,Thibault G,Decencière E,Marcotegui B,Laÿ B,Danno R,Cazuguel G,Quellec G,Lamard M,Massin P,Chabouis A,Victor Z,Erginay A

    更新日期:2014-10-01 00:00:00

  • Independent component analysis using prior information for signal detection in a functional imaging system of the retina.

    abstract::Independent component analysis (ICA) is a statistical technique that estimates a set of sources mixed by an unknown mixing matrix using only a set of observations. For this purpose, the only assumption is that the sources are statistically independent. In many applications, some information about the nature of the unk...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2010.06.009

    authors: Barriga ES,Pattichis M,Ts'o D,Abramoff M,Kardon R,Kwon Y,Soliz P

    更新日期:2011-02-01 00:00:00

  • Spatially variable Rician noise in magnetic resonance imaging.

    abstract::Magnetic resonance images tend to be influenced by various random factors usually referred to as "noise". The principal sources of noise and related artefacts can be divided into two types: arising from hardware (acquisition coil arrays, gradient coils, field inhomogeneity); and arising from the subject (physiological...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2011.12.002

    authors: Maximov II,Farrher E,Grinberg F,Shah NJ

    更新日期:2012-02-01 00:00:00

  • Rubik's Cube+: A self-supervised feature learning framework for 3D medical image analysis.

    abstract::Due to the development of deep learning, an increasing number of research works have been proposed to establish automated analysis systems for 3D volumetric medical data to improve the quality of patient care. However, it is challenging to obtain a large number of annotated 3D medical data needed to train a neural net...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2020.101746

    authors: Zhu J,Li Y,Hu Y,Ma K,Zhou SK,Zheng Y

    更新日期:2020-08-01 00:00:00

  • A work flow to build and validate patient specific left atrium electrophysiology models from catheter measurements.

    abstract::Biophysical models of the atrium provide a physically constrained framework for describing the current state of an atrium and allow predictions of how that atrium will respond to therapy. We propose a work flow to simulate patient specific electrophysiological heterogeneity from clinical data and validate the resultin...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2018.04.005

    authors: Corrado C,Williams S,Karim R,Plank G,O'Neill M,Niederer S

    更新日期:2018-07-01 00:00:00

  • Computer aided diagnosis of thyroid nodules based on the devised small-datasets multi-view ensemble learning.

    abstract::With the development of deep learning, its application in diagnosis of benign and malignant thyroid nodules has been widely concerned. However, it is difficult to obtain medical images, resulting in insufficient number of data, which contradicts the large amount of data required for acquiring effective deep learning d...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2020.101819

    authors: Chen Y,Li D,Zhang X,Jin J,Shen Y

    更新日期:2021-01-01 00:00:00

  • A comparison of freehand three-dimensional ultrasound reconstruction techniques.

    abstract::Three-dimensional freehand ultrasound imaging produces a set of irregularly spaced B-scans, which are typically reconstructed on a regular grid for visualization and data analysis. Most standard reconstruction algorithms are designed to minimize computational requirements and do not exploit the underlying shape of the...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/s1361-8415(99)80028-0

    authors: Rohling R,Gee A,Berman L

    更新日期:1999-12-01 00:00:00

  • Coupling of fluid and elastic models for biomechanical simulations of brain deformations using FEM.

    abstract::In order to improve the accuracy of image-guided neurosurgery, different biomechanical models have been developed to correct preoperative images with respect to intraoperative changes like brain shift or tumor resection. All existing biomechanical models simulate different anatomical structures by using either appropr...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/s1361-8415(02)00059-2

    authors: Hagemann A,Rohr K,Stiehl HS

    更新日期:2002-12-01 00:00:00

  • BrainSuite: an automated cortical surface identification tool.

    abstract::We describe a new magnetic resonance (MR) image analysis tool that produces cortical surface representations with spherical topology from MR images of the human brain. The tool provides a sequence of low-level operations in a single package that can produce accurate brain segmentations in clinical time. The tools incl...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/s1361-8415(02)00054-3

    authors: Shattuck DW,Leahy RM

    更新日期:2002-06-01 00:00:00

  • Statistical shape models for 3D medical image segmentation: a review.

    abstract::Statistical shape models (SSMs) have by now been firmly established as a robust tool for segmentation of medical images. While 2D models have been in use since the early 1990 s, wide-spread utilization of three-dimensional models appeared only in recent years, primarily made possible by breakthroughs in automatic dete...

    journal_title:Medical image analysis

    pub_type: 杂志文章,评审

    doi:10.1016/j.media.2009.05.004

    authors: Heimann T,Meinzer HP

    更新日期:2009-08-01 00:00:00

  • Robust estimation of carotid artery wall motion using the elasticity-based state-space approach.

    abstract::The dynamics of the carotid artery wall has been recognized as a valuable indicator to evaluate the status of atherosclerotic disease in the preclinical stage. However, it is still a challenge to accurately measure this dynamics from ultrasound images. This paper aims at developing an elasticity-based state-space appr...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2017.01.004

    authors: Gao Z,Xiong H,Liu X,Zhang H,Ghista D,Wu W,Li S

    更新日期:2017-04-01 00:00:00

  • Vessel extraction from non-fluorescein fundus images using orientation-aware detector.

    abstract::The automatic extraction of blood vessels in non-fluorescein eye fundus images is a tough task in applications such as diabetic retinopathy screening. However, vessel shapes have complex variations, and accurate modeling of retinal vascular structures is challenging. We have therefore developed a new approach to accur...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2015.09.002

    authors: Yin B,Li H,Sheng B,Hou X,Chen Y,Wu W,Li P,Shen R,Bao Y,Jia W

    更新日期:2015-12-01 00:00:00

  • Automated annotation and quantitative description of ultrasound videos of the fetal heart.

    abstract::Interpretation of ultrasound videos of the fetal heart is crucial for the antenatal diagnosis of congenital heart disease (CHD). We believe that automated image analysis techniques could make an important contribution towards improving CHD detection rates. However, to our knowledge, no previous work has been done in t...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2016.11.006

    authors: Bridge CP,Ioannou C,Noble JA

    更新日期:2017-02-01 00:00:00

  • Development and comparison of new hybrid motion tracking for bronchoscopic navigation.

    abstract::This paper presents a new hybrid camera motion tracking method for bronchoscopic navigation combining SIFT, epipolar geometry analysis, Kalman filtering, and image registration. In a thorough evaluation, we compare it to state-of-the-art tracking methods. Our hybrid algorithm for predicting bronchoscope motion uses SI...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2010.11.001

    authors: Luó X,Feuerstein M,Deguchi D,Kitasaka T,Takabatake H,Mori K

    更新日期:2012-04-01 00:00:00

  • Groupwise registration with global-local graph shrinkage in atlas construction.

    abstract::Graph-based groupwise registration methods are widely used in atlas construction. Given a group of images, a graph is built whose nodes represent the images, and whose edges represent a geodesic path between two nodes. The distribution of images on an image manifold is explored through edge traversal in a graph. The f...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2020.101711

    authors: Fu T,Yang J,Li Q,Ai D,Song H,Jiang Y,Wang Y,Frangi AF

    更新日期:2020-08-01 00:00:00

  • Unmixing dynamic PET images with variable specific binding kinetics.

    abstract::To analyze dynamic positron emission tomography (PET) images, various generic multivariate data analysis techniques have been considered in the literature, such as principal component analysis (PCA), independent component analysis (ICA), factor analysis and nonnegative matrix factorization (NMF). Nevertheless, these c...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2018.07.011

    authors: Cavalcanti YC,Oberlin T,Dobigeon N,Stute S,Ribeiro M,Tauber C

    更新日期:2018-10-01 00:00:00

  • IDRiD: Diabetic Retinopathy - Segmentation and Grading Challenge.

    abstract::Diabetic Retinopathy (DR) is the most common cause of avoidable vision loss, predominantly affecting the working-age population across the globe. Screening for DR, coupled with timely consultation and treatment, is a globally trusted policy to avoid vision loss. However, implementation of DR screening programs is chal...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2019.101561

    authors: Porwal P,Pachade S,Kokare M,Deshmukh G,Son J,Bae W,Liu L,Wang J,Liu X,Gao L,Wu T,Xiao J,Wang F,Yin B,Wang Y,Danala G,He L,Choi YH,Lee YC,Jung SH,Li Z,Sui X,Wu J,Li X,Zhou T,Toth J,Baran A,Kori A,Ch

    更新日期:2020-01-01 00:00:00