Patient-controlled oral analgesia versus nurse-controlled parenteral analgesia after caesarean section: a randomised controlled trial.

Abstract:

:We assessed the effectiveness of early patient-controlled oral analgesia compared with parenteral analgesia in a randomised controlled non-inferiority trial of women undergoing elective caesarean section under regional anaesthesia. Seventy-seven women received multimodal paracetamol, ketoprofen and morphine analgesia. The woman having patient-controlled oral analgesia were administered four pillboxes on the postnatal ward containing tablets and instructions for self-medication, the first at 7 h after the spinal injection and then three more at 12-hourly intervals. Pain at rest and on movement was evaluated using an 11-point verbal rating scale at 2 h and then at 6-hourly intervals for 48 h. The pre-defined non-inferiority limit for the difference in mean pain scores (patient-controlled oral analgesia minus parenteral) was one. The one-sided 95% CI of the difference in mean pain scores was significantly lower than one at all time-points at rest and on movement, demonstrating non-inferiority of patient-controlled oral analgesia. More women used morphine in the patient-controlled oral analgesia group (22 (58%)) than in the parenteral group (9 (23%); p = 0.002). The median (IQR [range]) number of morphine doses in the patient-controlled oral analgesia group was 2 (1-3 [1-7]) compared with 1 (1-1 [1-2]); p = 0.006) in the parenteral group. Minor drug errors or omissions were identified in five (13%) women receiving patient-controlled oral analgesia. Pruritus was more frequent in the patient-controlled oral analgesia group (14 (37%) vs 6 (15%) respectively; p = 0.03), but no differences were noted for other adverse events and maternal satisfaction. After elective caesarean section, early patient-controlled oral analgesia is non-inferior to standard parenteral analgesia for pain management, and can be one of the steps of an enhanced recovery process.

journal_name

Anaesthesia

journal_title

Anaesthesia

authors

Bonnal A,Dehon A,Nagot N,Macioce V,Nogue E,Morau E

doi

10.1111/anae.13406

subject

Has Abstract

pub_date

2016-05-01 00:00:00

pages

535-43

issue

5

eissn

0003-2409

issn

1365-2044

journal_volume

71

pub_type

杂志文章,随机对照试验
  • Accidental intravenous injection of cetrimide. A case report.

    abstract::An unusual case of cetrimide toxicity, probably the first of its kind to be recorded, is reported. It occurred after accidental intravenous injection in an infant and the management is discussed. Cardiac arrest, muscle paralysis, haemolysis and other complications were successfully treated. ...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.1975.tb00897.x

    authors: Gode GR,Jayalakshmi TS,Kalla GN

    更新日期:1975-07-01 00:00:00

  • Harold King. A notable contributor to anaesthesia.

    abstract::Harold King was an analytical chemist of distinction, who worked with Sir Henry Dale and his colleagues in the Medical Research Institute, later the Medical Research Council. He helped to quash the theory that the anaesthetic action of ether was attributable to its impurities. Interest in alkaloids led to the elucidat...

    journal_title:Anaesthesia

    pub_type: 传,历史文章,杂志文章

    doi:10.1111/j.1365-2044.1991.tb09723.x

    authors: Gray TC

    更新日期:1991-08-01 00:00:00

  • Electrocardiographic studies during hypotensive anaesthesia using sodium nitroprusside.

    abstract::Multiple lead electrocardiographic recordings from 20 patients were studied before, during and after a period of induced hypotension with sodium nitroprusside. Although small changes in ST segment and T wave were observed in 9 patients, none of these persisted into the postoperative period. Other significant changes w...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.1976.tb11968.x

    authors: Simpson P,Bellamy D,Cole P

    更新日期:1976-11-01 00:00:00

  • Antireflux valves in patient-controlled analgesia.

    abstract::Antireflux valves are widely used in conjunction with patient-controlled analgesia devices. It is important to appreciate the limitations and dangers of these systems. They can achieve a potential 'stored volume' if occluded and they may, as part of the administration set, retard fluid administration. Seven antireflux...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.1990.tb14889.x

    authors: Kluger MT,Owen H

    更新日期:1990-12-01 00:00:00

  • Haemodynamic effects of intravenous nimodipine following aneurysmal subarachnoid haemorrhage: implications for monitoring.

    abstract::Nimodipine is widely used in patients with aneurysmal subarachnoid haemorrhage for the prevention and treatment of delayed ischaemic neurological deficits. Intravenous nimodipine has significant vasodilatory properties and may compromise the achievement of haemodynamic targets in patients who receive hypertensive hype...

    journal_title:Anaesthesia

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1365-2044.1997.112-az0105.x

    authors: Radhakrishnan D,Menon DK

    更新日期:1997-05-01 00:00:00

  • Dural puncture during attempted stellate ganglion block.

    abstract::Dural puncture is rarely reported as a complication of stellate ganglion blockade. Breach of the dura occurred in the case described because of the anatomy of the cervical spine. ...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.1990.tb14628.x

    authors: Stannard CF,Glynn CJ,Smith SP

    更新日期:1990-11-01 00:00:00

  • Use of the Combitube for airway maintenance during percutaneous dilatational tracheostomy.

    abstract::The Combitube airway allows short-term ventilation during cardiopulmonary resuscitation and can be useful in the management of the difficult airway. In a prospective observational study we assessed its use during percutaneous dilatational tracheostomy (PDT). Twenty-one intensive care patients scheduled for elective PD...

    journal_title:Anaesthesia

    pub_type: 临床试验,杂志文章

    doi:10.1046/j.1365-2044.1998.00320.x

    authors: Mallick A,Quinn AC,Bodenham AR,Vucevic M

    更新日期:1998-03-01 00:00:00

  • Peri-operative troponin I concentration as a marker of long-term postoperative adverse cardiac outcomes--a study in high-risk surgical patients.

    abstract::We have previously demonstrated that the peri-operative measurement of increased serum concentrations of the cardiac markers troponins I and T and creatine kinase-MB can be predictors of major cardiovascular outcomes (including cardiac death) at 3 months after surgery. In the present study, we have followed the postop...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.2004.03660.x

    authors: Higham H,Sear JW,Sear YM,Kemp M,Hooper RJ,Foex P

    更新日期:2004-04-01 00:00:00

  • A novel device for patient-controlled sedation: laboratory and clinical evaluation of the Baxter Intermate LV250 infusor and patient-control module.

    abstract::The Baxter Intermate LV250 infusor is a large capacity, high flow mechanical infusor, designed to deliver viscous solutions and suspensions. The objective of the laboratory study was to evaluate the LV250 infusor when used with either 0.9% sodium chloride solution or an emulsion, propofol 1%. Following this, the LV250...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.1996.tb07702.x

    authors: Hamid SK,Wong PK,Carmichael F,White K,Asbury AJ

    更新日期:1996-02-01 00:00:00

  • A randomised comparison between ultrasound and nerve stimulation for infraclavicular catheter placement.

    abstract::We conducted this study to determine if placement of infraclavicular catheters guided by ultrasound is quicker than placement guided by nerve stimulation. Infraclavicular brachial plexus catheters were inserted in 210 randomly allocated patients who were scheduled for elective hand or elbow surgery. Needle and cathete...

    journal_title:Anaesthesia

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/anae.13302

    authors: Dhir S,Armstrong K,Armstrong P,Bouzari A,Mall J,Yu J,Ganapathy S,King G

    更新日期:2016-02-01 00:00:00

  • The safety of atropine premedication in children with Down's syndrome.

    abstract::Forty-five operative procedures were performed in 32 patients with Down's syndrome at the Royal Alexandra Hospital for Children, Sydney in a single year recently. Atropine premedication was administered to 25 patients with Down's syndrome on 38 occasions. Three dosage regimes of atropine were used: 20 micrograms/kg, 1...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.1983.tb12253.x

    authors: Wark HJ,Overton JH,Marian P

    更新日期:1983-09-01 00:00:00

  • Comparison of the Williams Airway Intubator and Ovassapian Fibreoptic Intubating Airway for fibreoptic orotracheal intubation.

    abstract::A randomised study was carried out in 60 anaesthetised patients with no evidence of airway difficulties, to compare the Williams Airway Intubator and the Ovassapian Fibreoptic Intubating Airway for bronchoscopic view and ease of railroading a tracheal tube during fibreoptic orotracheal intubation. The Williams Airway ...

    journal_title:Anaesthesia

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1111/j.1365-2044.2004.03527.x

    authors: Greenland KB,Lam MC,Irwin MG

    更新日期:2004-02-01 00:00:00

  • Comparison of the C-MAC videolaryngoscope with the Macintosh, Glidescope, and Airtraq laryngoscopes in easy and difficult laryngoscopy scenarios in manikins.

    abstract::The C-MAC comprises a Macintosh blade connected to a video unit. The familiarity of the Macintosh blade, and the ability to use the C-MAC as a direct or indirect laryngoscope, may be advantageous. We wished to compare the C-MAC with Macintosh, Glidescope and Airtraq laryngoscopes in easy and simulated difficult laryng...

    journal_title:Anaesthesia

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/j.1365-2044.2010.06307.x

    authors: McElwain J,Malik MA,Harte BH,Flynn NM,Laffey JG

    更新日期:2010-05-01 00:00:00

  • Respiratory disturbance during recovery from etomidate anaesthesia.

    abstract::A case is described in which recovery from the administration of a single dose of etomidate was complicated by periodic episodes of unconsciousness, tremor and apnoea. Subsequent investigations did not reveal any evidence of neurological disease. ...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.1988.tb05415.x

    authors: Parker CJ

    更新日期:1988-01-01 00:00:00

  • Anaesthesia in a patient with Noonan's syndrome and cardiomyopathy.

    abstract::A 5-year-old girl with Noonan's syndrome and a hypertrophic cardiomyopathy presented for myelography and subsequently, laminectomy. The anaesthetic management of the patient is described and the potential problems of the facial, cardiovascular and skeletal abnormalities associated with the condition are discussed. ...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.1992.tb02010.x

    authors: Campbell AM,Bousfield JD

    更新日期:1992-02-01 00:00:00

  • Comparison of peripheral nerve blockade characteristics between non-diabetic patients and patients suffering from diabetic neuropathy: a prospective cohort study.

    abstract::Animal data have demonstrated increased block duration after local anaesthetic injections in diabetic rat models. Whether the same is true in humans is currently undefined. We, therefore, undertook this prospective cohort study to test the hypothesis that type-2 diabetic patients suffering from diabetic peripheral neu...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/anae.14347

    authors: Baeriswyl M,Taffé P,Kirkham KR,Bathory I,Rancati V,Crevoisier X,Cherix S,Albrecht E

    更新日期:2018-09-01 00:00:00

  • Does the laryngeal mask airway compromise cricoid pressure?

    abstract::The laryngeal mask airway was inserted in 10 cadavers. At postmortem the chest was opened and an infusion set primed with a dilute barium solution was inserted into the oesophagus and ligated in place. A cricoid force of 43 N was then applied and the infusion set was positioned so that when the clamp was opened it gen...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.1992.tb03138.x

    authors: Strang TI

    更新日期:1992-10-01 00:00:00

  • EchoComTEE - a simulator for transoesophageal echocardiography.

    abstract::Transoesophageal echocardiography (TOE) requires extensive hands-on training, and it is for this purpose we have designed EchoComTEE, a simulator for TOE. It consists of a manikin and dummy probe; according to the position of the dummy probe (tracked by an electromagnetic sensor), two-dimensional (2D) images are calcu...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.2007.04978.x

    authors: Weidenbach M,Drachsler H,Wild F,Kreutter S,Razek V,Grunst G,Ender J,Berlage T,Janousek J

    更新日期:2007-04-01 00:00:00

  • Tracheal intubation following training with the GlideScope compared to direct laryngoscopy.

    abstract:SUMMARY:Tracheal intubation using direct laryngoscopy has a high failure rate when performed by untrained medical personnel. This study compares tracheal intubation following direct laryngoscopy by inexperienced medical students when initially trained by using either the GlideScope, a video assisted laryngoscope, or a ...

    journal_title:Anaesthesia

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/j.1365-2044.2010.06335.x

    authors: Ayoub CM,Kanazi GE,Al Alami A,Rameh C,El-Khatib MF

    更新日期:2010-07-01 00:00:00

  • Susceptibility of the pilot balloon of the disposable laryngeal mask airway to puncture during laser therapy.

    abstract::The tube of the laryngeal mask airway is frequently protected by foil during ablative laser procedures. The pilot balloon, however, is often left exposed. The effect of firing seven different cutaneous lasers at the pilot balloon of a disposable laryngeal mask airway was examined to assess its susceptibility to accide...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.2011.07025.x

    authors: Chilcott A,Lister TS,Geary PM,Wright PA

    更新日期:2012-05-01 00:00:00

  • A European consensus statement on the use of four-factor prothrombin complex concentrate for cardiac and non-cardiac surgical patients.

    abstract::Modern four-factor prothrombin complex concentrate was designed originally for rapid targeted replacement of the coagulation factors II, VII, IX and X. Dosing strategies for the approved indication of vitamin K antagonist-related bleeding vary greatly. They include INR and bodyweight-related protocols as well as fixed...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/anae.15181

    authors: Erdoes G,Koster A,Ortmann E,Meesters MI,Bolliger D,Baryshnikova E,Martinez Lopez De Arroyabe B,Ahmed A,Lance MD,Ranucci M,von Heymann C,Agarwal S,Ravn HB

    更新日期:2020-07-17 00:00:00

  • Initial experience with Minaxolone. A water-soluble steroid intravenous anaesthetic agent.

    abstract::Minaxolone has been used to induce anaesthesia, and in incremental doses to supplement nitrous oxide, in 100 patients undergoing minor surgical procedures. Half the patients received a small dose of fentanyl before induction. Minaxolone proved to be a satisfactory induction agent. The commonest complications were an i...

    journal_title:Anaesthesia

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1111/j.1365-2044.1980.tb03805.x

    authors: Punchihewa VG,Morgan M,Lumley J,Whitwam JG

    更新日期:1980-02-01 00:00:00

  • Litigation related to airway and respiratory complications of anaesthesia: an analysis of claims against the NHS in England 1995-2007.

    abstract::Claims notified to the NHS Litigation Authority in England between 1995 and 2007 and filed under anaesthesia were analysed to explore patterns of injury and cost related to airway or respiratory events. Of 841 interpretable claims the final dataset contained 96 claims of dental damage, 67 airway-related claims and 24 ...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.2010.06331.x

    authors: Cook TM,Scott S,Mihai R

    更新日期:2010-06-01 00:00:00

  • Ventricular fibrillation after accidental injection of bupivacaine into the pericardium.

    abstract::A postoperative cardiac surgical patient developed ventricular fibrillation immediately after accidental pericardial injection of bupivacaine at room temperature. The possible causes, which include systemic toxicity, local vasoconstriction with myocardial ischaemia, local toxic effect of bupivacaine or local hypotherm...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.1992.tb04202.x

    authors: Even BJ,De Jongh RF,De Hert SG

    更新日期:1992-12-01 00:00:00

  • Free-standing vaporizers. Another hazard.

    abstract::A previously unreported hazard of free-standing 'Tec' type vaporizers relating to their positioning downstream of the oxygen flush is presented. Three Enfluratec Mark III vaporizers were studied; measurement of delivered enflurane concentration was performed at a flow rate of 8 litres/minute, during and after the appl...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.1985.tb10946.x

    authors: Kelly DA

    更新日期:1985-07-01 00:00:00

  • Calculation of inspired oxygen fraction during anaesthesia based on awake oxygen saturation.

    abstract::One hundred ASA grade 1 or 2 patients were studied to assess the use of awake oxygen saturation to determine the necessary inspired oxygen fraction during anaesthesia. The inspired oxygen fraction was adjusted gradually to the lowest possible value to maintain the pre-operative oxygen saturation at a constant level. N...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.1994.tb04411.x

    authors: Mandal P,Chaudhary S

    更新日期:1994-08-01 00:00:00

  • Adverse reaction to methohexitone and gallamine.

    abstract::A case is presented in which a patient developed an acute anaphylactoid reaction after receiving methohexitone and gallamine for the induction of anaesthesia. The problem of eliciting the responsible agent is discussed, which comments on the method of treatment and preventative measures. ...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.1981.tb08597.x

    authors: Harrison GR,Thompson ID

    更新日期:1981-01-01 00:00:00

  • Modified patient-controlled remifentanil bolus delivery regimen for labour pain*.

    abstract::To improve the analgesic efficiency and to simplify the administration of remifentanil for systemic analgesia in labour, we contrived a modified delivery regimen with a specific infusion profile and variable dosing and conducted a single-blind randomised crossover study to compare it with the previous 'classical' regi...

    journal_title:Anaesthesia

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/anae.12038

    authors: Jost A,Ban B,Kamenik M

    更新日期:2013-03-01 00:00:00

  • Legal and ethical implications of defining an optimum means of achieving unconsciousness in assisted dying.

    abstract::A decision by a society to sanction assisted dying in any form should logically go hand-in-hand with defining the acceptable method(s). Assisted dying is legal in several countries and we have reviewed the methods commonly used, contrasting these with an analysis of capital punishment in the USA. We expected that, sin...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/anae.14532

    authors: Sinmyee S,Pandit VJ,Pascual JM,Dahan A,Heidegger T,Kreienbühl G,Lubarsky DA,Pandit JJ

    更新日期:2019-05-01 00:00:00

  • Peripheral oxygen extraction in patients with malignant obstructive jaundice.

    abstract::Malignant obstructive jaundice is associated with poor aerobic capacity. We measured oxygen consumption and oxygen extraction (arterial-venous oxygen content) in the legs of nine patients during cardiopulmonary exercise testing before pancreaticoduodenectomy. The median (IQR [range]) peak oxygen consumption was 67 (49...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/anae.12478

    authors: Junejo MA,Siriwardena AK,Parker MJ

    更新日期:2014-01-01 00:00:00