MRI texture analysis of subchondral bone at the tibial plateau.

Abstract:

OBJECTIVES:To determine the feasibility of MRI texture analysis as a method of quantifying subchondral bone architecture in knee osteoarthritis (OA). METHODS:Asymptomatic subjects aged 20-30 (group 1, n = 10), symptomatic patients aged 40-50 (group 2, n = 10) and patients scheduled for knee replacement aged 55-85 (group 3, n = 10) underwent high spatial resolution T1-weighted coronal 3T knee MRI. Regions of interest were created in the medial (MT) and lateral (LT) tibial subchondral bone from which 20 texture parameters were calculated. T2 mapping of the tibial cartilage was performed in groups 1 and 2. Mean parameter values were compared between groups using ANOVA. Linear discriminant analysis (LDA) was used to evaluate the ability of texture analysis to classify subjects correctly. RESULTS:Significant differences in 18/20 and 12/20 subchondral bone texture parameters were demonstrated between groups at the MT and LT respectively. There was no significant difference in mean MT or LT cartilage T2 values between group 1 and group 2. LDA demonstrated subject classification accuracy of 97 % (95 % CI 91-100 %). CONCLUSION:MRI texture analysis of tibial subchondral bone may allow detection of alteration in subchondral bone architecture in OA. This has potential applications in understanding OA pathogenesis and assessing response to treatment. KEY POINTS:• Improved techniques to monitor OA disease progression and treatment response are desirable • Subchondral bone (SB) may play significant role in the development of OA • MRI texture analysis is a method of quantifying changes in SB architecture • Pilot study showed that this technique is feasible and reliable • Significant differences in SB texture were demonstrated between individuals with/without OA.

journal_name

Eur Radiol

journal_title

European radiology

authors

MacKay JW,Murray PJ,Kasmai B,Johnson G,Donell ST,Toms AP

doi

10.1007/s00330-015-4142-0

subject

Has Abstract

pub_date

2016-09-01 00:00:00

pages

3034-45

issue

9

eissn

0938-7994

issn

1432-1084

pii

10.1007/s00330-015-4142-0

journal_volume

26

pub_type

杂志文章
  • Influence of intra-coronary enhancement on diagnostic accuracy with 64-slice CT coronary angiography.

    abstract::We assessed the effect of intra-coronary attenuation on diagnostic accuracy using 64-slice computed tomography coronary angiography (CT-CA). We enrolled 170 patients with suspected coronary artery disease who underwent conventional coronary angiography (CA) and 64-slice CT-CA (100 ml of Iomeprol 400 mg I/ml at 4 ml/s)...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-007-0773-0

    authors: Cademartiri F,Maffei E,Palumbo AA,Malagò R,La Grutta L,Meiijboom WB,Aldrovandi A,Fusaro M,Vignali L,Menozzi A,Brambilla V,Coruzzi P,Midiri M,Kirchin MA,Mollet NR,Krestin GP

    更新日期:2008-03-01 00:00:00

  • Single- and dual-energy CT of the abdomen: comparison of radiation dose and image quality of 2nd and 3rd generation dual-source CT.

    abstract:OBJECTIVES:To compare single-energy (SECT) and dual-energy (DECT) abdominal CT examinations in matched patient cohorts regarding differences in radiation dose and image quality performed with second- and third-generation dual-source CT (DSCT). METHODS:We retrospectively analysed 200 patients (100 male, 100 female; mea...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4383-6

    authors: Wichmann JL,Hardie AD,Schoepf UJ,Felmly LM,Perry JD,Varga-Szemes A,Mangold S,Caruso D,Canstein C,Vogl TJ,De Cecco CN

    更新日期:2017-02-01 00:00:00

  • Non-enhanced ultrasound is not a satisfactory modality for measuring necrotic ablated volume after radiofrequency ablation of benign thyroid nodules: a comparison with contrast-enhanced ultrasound.

    abstract:OBJECTIVE:To investigate the intra- and inter-observer reliability and agreement between gray-scale and Doppler ultrasound (US) and contrast-enhanced ultrasound (CEUS) in measuring ablated volume (Va) after radiofrequency ablation (RFA) for benign thyroid nodules. METHODS:A total of 173 patients with 190 benign thyroi...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07398-0

    authors: Yan L,Luo Y,Xiao J,Lin L

    更新日期:2020-10-31 00:00:00

  • Concomitant chronic venous insufficiency in patients with peripheral artery disease: insights from MR angiography.

    abstract:OBJECTIVES:The clinical presentation of peripheral artery disease (PAD) and chronic venous insufficiency (CVI) can overlap and the conditions may co-exist. The purpose of our study was to investigate the prevalence and clinical significance of concomitant CVI in patients with PAD examined with run-off MR angiography (M...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-06696-x

    authors: Ammermann F,Meinel FG,Beller E,Busse A,Streckenbach F,Teichert C,Weinrich M,Neumann A,Weber MA,Heller T

    更新日期:2020-07-01 00:00:00

  • Percutaneous thrombin injection for the treatment of a post-pancreatitis pseudoaneurysm.

    abstract::Visceral artery pseudoaneurysms are often treated surgically or by transcatheter embolisation. We report a case of a pseudoaneurysm in a patient with chronic pancreatitis, which was successfully occluded by percutaneous injection of thrombin into the pseudoaneurysmal sac as a first-line management. ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-003-1836-5

    authors: Puri S,Nicholson AA,Breen DJ

    更新日期:2003-12-01 00:00:00

  • Cardiac pathologies in female carriers of Duchenne muscular dystrophy assessed by cardiovascular magnetic resonance imaging.

    abstract:OBJECTIVES:Duchenne muscular dystrophy (DMD) is the most common and severe dystrophinopathy. DMD carriers rarely present with clinical symptoms, but may suffer from cardiac involvement. Because echocardiographic findings are inconsistent and cardiac magnetic resonance imaging (CMRI) data are limited, this study sought ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-3694-3

    authors: Schelhorn J,Schoenecker A,Neudorf U,Schemuth H,Nensa F,Nassenstein K,Forsting M,Schara U,Schlosser T

    更新日期:2015-10-01 00:00:00

  • Radiofrequency thermal ablation with expandable needle of focal liver malignancies: complication report.

    abstract::The aim of this study was to describe type and rate of complications in a series of patients with liver tumors treated by the radiofrequency (RF) expandable system. A total of 166 patients, 114 with hepatocellular carcinoma (HCC; 92 small HCC, 22 large) and 52 with liver metastasis, were treated by the percutaneous RF...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-003-1990-9

    authors: Buscarini E,Buscarini L

    更新日期:2004-01-01 00:00:00

  • Structural changes induced by antineoplastic therapies: keys to evaluate tumor response to treatment.

    abstract::The criteria to define therapeutic response in oncology are those proposed by Miller, characterized by four response categories (complete response, partial response, no change, progression of disease), and based upon both measurable and non-measurable (and otherwise assessable) morphological parameters in comparison w...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s003300101074

    authors: Ferrozzi F,Tognini G,Pavone P

    更新日期:2002-04-01 00:00:00

  • Intravoxel water diffusion heterogeneity MR imaging of nasopharyngeal carcinoma using stretched exponential diffusion model.

    abstract:PURPOSE:To determine the utility of stretched exponential diffusion model in characterisation of the water diffusion heterogeneity in different tumour stages of nasopharyngeal carcinoma (NPC). MATERIALS AND METHODS:Fifty patients with newly diagnosed NPC were prospectively recruited. Diffusion-weighted MR imaging was ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3535-9

    authors: Lai V,Lee VH,Lam KO,Sze HC,Chan Q,Khong PL

    更新日期:2015-06-01 00:00:00

  • Radiation dose management systems-requirements and recommendations for users from the ESR EuroSafe Imaging initiative.

    abstract::The European Directive 2013/59/Euratom requires member states of the European Union to ensure justification and optimisation of radiological procedures and store information on patient exposure for analysis and quality assurance. The EuroSafe Imaging campaign of the European Society of Radiology created a working grou...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07290-x

    authors: Loose RW,Vano E,Mildenberger P,Tsapaki V,Caramella D,Sjöberg J,Paulo G,Torresin A,Schindera S,Frija G,Damilakis J,European Society of Radiology (ESR).

    更新日期:2020-09-21 00:00:00

  • Large-volume multi-tined expandable RF ablation in pig livers: comparison of 2D and volumetric measurements of the ablation zone.

    abstract:OBJECTIVES:To compare two-dimensional (2D) and three-dimensional (3D) computed tomography (CT) measurements of ablation zones (AZs) related to the shaft of two different large-volume monopolar multi-tined expandable electrodes. METHODS:Percutaneous radiofrequency (RF) ablation was performed in 12 pigs (81.6 +/- 7.8 kg...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1639-4

    authors: Bangard C,Rösgen S,Wahba R,Wiemker R,Hellmich M,Reiter H,Fischer JH,Stippel DL,Lackner KJ

    更新日期:2010-05-01 00:00:00

  • The value of time-intensity curves obtained after microbubble contrast agent injection to discriminate responders from non-responders to anti-inflammatory medication among patients with Crohn's disease.

    abstract:OBJECTIVE:To assess the value of time-intensity curves obtained after sulphur hefluoride-filled microbubble contrast agent injection to discriminate responders from non-responders among patients with Crohn's disease (CD). METHODS:Forty-three patients (29 male and 14 female; mean age ± SD, 48.5 ± 17.17 years) with init...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2754-1

    authors: Quaia E,Cabibbo B,De Paoli L,Toscano W,Poillucci G,Cova MA

    更新日期:2013-06-01 00:00:00

  • Advances in ultrasound.

    abstract::Significant advances have been recently introduced into various fields of technology, taking advantage of the use of new piezoelectric materials and the large diffusion of broadband transducers. Various types of modulation may be applied to the pulse characteristics, using single pulse, multipulse or multiline techniq...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-001-1185-1

    authors: Claudon M,Tranquart F,Evans DH,Lefèvre F,Correas M

    更新日期:2002-01-01 00:00:00

  • Facing privacy in neuroimaging: removing facial features degrades performance of image analysis methods.

    abstract:BACKGROUND:Recent studies have created awareness that facial features can be reconstructed from high-resolution MRI. Therefore, data sharing in neuroimaging requires special attention to protect participants' privacy. Facial features removal (FFR) could alleviate these concerns. We assessed the impact of three FFR meth...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06459-3

    authors: de Sitter A,Visser M,Brouwer I,Cover KS,van Schijndel RA,Eijgelaar RS,Müller DMJ,Ropele S,Kappos L,Rovira Á,Filippi M,Enzinger C,Frederiksen J,Ciccarelli O,Guttmann CRG,Wattjes MP,Witte MG,de Witt Hamer PC,Barkhof F,

    更新日期:2020-02-01 00:00:00

  • A new device for retrograde urethrography in the male.

    abstract::A new technique is presented for retrograde urethrography (RGU) using a plastic adjustable clamp. The procedure was performed in 36 patients with suspected urethral stenosis. Mean age was 55.3 years. The device and the procedure are described. All the radiologic examinations of the urethra were carried out successfull...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1662-1

    authors: Berná JD,Berná JD Jr

    更新日期:2003-06-01 00:00:00

  • Respiratory lumenal change of the pharynx and trachea in normal subjects and COPD patients: assessment by cine-MRI.

    abstract::The purpose of this study was to use cine-MRI during continuous respiration to measure the respiratory lumenal diameter change in the pharynx and at an upper tracheal level. Fifteen non-smokers and 23 chronic obstructive pulmonary disease (COPD) patients with smoking history (median 50 pack-years) were included. Cine-...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-004-2461-7

    authors: Heussel CP,Ley S,Biedermann A,Rist A,Gast KK,Schreiber WG,Kauczor HU

    更新日期:2004-12-01 00:00:00

  • T2 black lesions on routine knee MRI: differential considerations.

    abstract::The majority of abnormal findings or lesions on T2-weighted fast spin-echo (FSE) magnetic resonance imaging (MRI) are hyperintense due to increased perfusion or fluid content, such as infections, tumours or synovitis. Hypointense lesions on T2-weighted images (both fat-suppressed and non-fat-suppressed) are less commo...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-015-4027-2

    authors: Wadhwa V,Cho G,Moore D,Pezeshk P,Coyner K,Chhabra A

    更新日期:2016-07-01 00:00:00

  • Integrated prediction of lesion-specific ischaemia from quantitative coronary CT angiography using machine learning: a multicentre study.

    abstract:OBJECTIVES:We aimed to investigate if lesion-specific ischaemia by invasive fractional flow reserve (FFR) can be predicted by an integrated machine learning (ML) ischaemia risk score from quantitative plaque measures from coronary computed tomography angiography (CTA). METHODS:In a multicentre trial of 254 patients, C...

    journal_title:European radiology

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1007/s00330-017-5223-z

    authors: Dey D,Gaur S,Ovrehus KA,Slomka PJ,Betancur J,Goeller M,Hell MM,Gransar H,Berman DS,Achenbach S,Botker HE,Jensen JM,Lassen JF,Norgaard BL

    更新日期:2018-06-01 00:00:00

  • Diagnostic value of time-resolved CT angiography for the lower leg.

    abstract:OBJECTIVE:The aim of this study was to test the feasibility of time-resolved computed tomography angiography (TR-CTA) for use in the lower leg. METHODS:Fifty-nine patients with suspected peripheral arterial occlusive disease were examined with a standard CTA (S-CTA) of the lower run-off and with an additional TR-CTA o...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-010-1861-0

    authors: Sommer WH,Helck A,Bamberg F,Albrecht E,Becker CR,Weidenhagen R,Kramer H,Reiser MF,Nikolaou K

    更新日期:2010-12-01 00:00:00

  • Benign versus metastatic vertebral compression fractures: combined diffusion-weighted MRI and MR spectroscopy aids differentiation.

    abstract:OBJECTIVES:To determine the residual lipid fraction in fractured vertebrae by (1)H MR spectroscopy (MRS) and its confounding effect on differentiating benign from metastatic compression fractures of the spine using apparent diffusion coefficient (ADC) obtained by diffusion-weighted read-out-segmented echo-planar imagin...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2620-1

    authors: Rumpel H,Chong Y,Porter DA,Chan LL

    更新日期:2013-02-01 00:00:00

  • Contrast-enhanced ultrasonography and spiral computed tomography in the detection and characterization of portal vein thrombosis complicating hepatocellular carcinoma.

    abstract::The aim was to compare the performances of contrast-enhanced (CE) ultrasonography (US) and spiral computed tomography (CT) in the detection and characterization of portal vein thrombosis complicating hepatocellular carcinoma (HCC). We studied 50 patients with HCC who had biopsy-proven portal vein thrombi that had been...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-008-0931-z

    authors: Rossi S,Ghittoni G,Ravetta V,Torello Viera F,Rosa L,Serassi M,Scabini M,Vercelli A,Tinelli C,Dal Bello B,Burns PN,Calliada F

    更新日期:2008-08-01 00:00:00

  • Triple-negative breast cancer: correlation between imaging and pathological findings.

    abstract:OBJECTIVE:This study was designed to investigate the mammography and ultrasound findings of triple-negative breast cancer and to compare the results with characteristics of ER-positive/PR-negative/HER2-negative breast cancer and ER-negative/PR-negative/HER2-positive breast cancer. METHODS:From January 2007 to October ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1656-3

    authors: Ko ES,Lee BH,Kim HA,Noh WC,Kim MS,Lee SA

    更新日期:2010-05-01 00:00:00

  • Coronary atherosclerosis profile in patients with end-stage liver disease prior to liver transplantation due to alcoholic fatty liver: a coronary CTA study.

    abstract:OBJECTIVES:To assess the coronary atherosclerosis profile by coronary computed tomography angiography (CTA) in patients with end-stage liver disease (ESLD) due to alcohol-related liver disease (ARLD) evaluated for liver transplantation (LT), in a retrospective matched case-controlled cohort study. METHODS:One hundred ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07037-8

    authors: Steinkohl F,Barbieri F,Senoner T,Strobl S,Finkenstedt A,Plank F,Langer C,Beyer C,Birkl K,Widmann G,Zoller H,Dichtl W,Friedrich G,Tilg H,Feuchtner G

    更新日期:2021-01-01 00:00:00

  • Imaging of aortic dissection by helical computed tomography (CT).

    abstract::Aortic dissection is the most frequent cause of aortic emergency, and its outcome is still frequently fatal. The management of this pathology has changed with the development of endovascular means. Nowadays, imaging modalities are helpful in management decision-making by providing information such as identification of...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-004-2441-y

    authors: Willoteaux S,Lions C,Gaxotte V,Negaiwi Z,Beregi JP

    更新日期:2004-11-01 00:00:00

  • Testicular microlithiasis: clinical significance and review of the literature.

    abstract::Testicular microlithiasis (TM) is an uncommon condition characterized by calcium deposits within the seminiferous tubules. On ultrasound (US), it is seen as multiple, uniform, nonshadowing echogenic foci in the testis. Although its true prevalence in the general population is still unknown, reported prevalences range ...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-003-2014-5

    authors: Kim B,Winter TC 3rd,Ryu JA

    更新日期:2003-12-01 00:00:00

  • Prediction of infarction development after endovascular stroke therapy with dual-energy computed tomography.

    abstract:OBJECTIVES:After intraarterial recanalisation (IAR), the haemorrhage and the blood-brain barrier (BBB) disruption can be distinguished using dual-energy computed tomography (DECT). The aim of the present study was to investigate whether future infarction development can be predicted from DECT. METHODS:DECT scans of 20...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4412-5

    authors: Djurdjevic T,Rehwald R,Knoflach M,Matosevic B,Kiechl S,Gizewski ER,Glodny B,Grams AE

    更新日期:2017-03-01 00:00:00

  • Assessment of myocardial viability by MR imaging.

    abstract::Diagnosis of myocardial viability after infarction focuses on the prediction of functional improvement of dysfunctional myocardium after revascularization therapy. Magnetic resonance imaging provides different approaches for the detection of myocardial viability. Measurement of end-diastolic wall thickness is easy to ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1701-y

    authors: Sandstede JJ

    更新日期:2003-01-01 00:00:00

  • Pitfalls and problems to be solved in the diagnostic CT/MRI Liver Imaging Reporting and Data System (LI-RADS).

    abstract::The 2017 Core of the computed tomography (CT)/magnetic resonance imaging (MRI) Liver Imaging Reporting and Data System (LI-RADS) provides clear definitions and concise explanations of the CT/MRI diagnostic algorithm. Nevertheless, there remain some practical and controversial issues that radiologists should be aware o...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-018-5641-6

    authors: Kim YY,Choi JY,Sirlin CB,An C,Kim MJ

    更新日期:2019-03-01 00:00:00

  • The value of fast MR imaging as an adjunct to ultrasound in prenatal diagnosis.

    abstract::The aim of this study was to evaluate the role of MR imaging of the fetus to improve sonographic prenatal diagnosis of congenital anomalies. In 40 fetuses (not consecutive cases) with an abnormality diagnosed with ultrasound, additional MR imaging was performed. The basic sequence was a T2-weighted single-shot half Fo...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1811-6

    authors: Breysem L,Bosmans H,Dymarkowski S,Schoubroeck DV,Witters I,Deprest J,Demaerel P,Vanbeckevoort D,Vanhole C,Casaer P,Smet M

    更新日期:2003-07-01 00:00:00

  • Quantitative CT texture and shape analysis: can it differentiate benign and malignant mediastinal lymph nodes in patients with primary lung cancer?

    abstract:OBJECTIVE:To assess the accuracy of CT texture and shape analysis in the differentiation of benign and malignant mediastinal nodes in lung cancer. METHODS:Forty-three patients with biopsy-proven primary lung malignancy with pathological mediastinal nodal staging and unenhanced CT of the thorax were studied retrospecti...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3420-6

    authors: Bayanati H,E Thornhill R,Souza CA,Sethi-Virmani V,Gupta A,Maziak D,Amjadi K,Dennie C

    更新日期:2015-02-01 00:00:00